• Title/Summary/Keyword: Floating power supply

Search Result 38, Processing Time 0.029 seconds

Floating Power Supply Based on Bootstrap Operation for Three-Level Neutral-Point-Clamped Voltage-Source Inverter

  • Nguyen, Qui Tu Vo;Lee, Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.3-4
    • /
    • 2011
  • This paper presents a survey of floating power supply based on bootstrap operation for three-level voltage-source inverters. The floating power supply for upper switches is achieved by the bootstrap capacitor charged during on-time of the switch underneath. Hence, a large number of bulky isolated DC/DC power supplies for each gate driver are reduced. The Pspice simulation results show the behavior of bootstrap devices and the performance of bootstrap capacitor voltage.

  • PDF

Design of Charge Pump Circuit for Floating Gate Power Supply of Intelligent Power Module (Intelligent Power Module의 플로팅 게이트 전원 공급을 위한 전하 펌프 회로의 설계)

  • Lim, Jeong-Gyu;Chung, Se-Kyo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.135-144
    • /
    • 2008
  • A bootstrap circuit is widely used for the floating gate power supply of Intelligent power module (IPM). A bootstrap circuit is simple and inexpensive. However, the duty cycle and on-time are limited by the requirement to refresh the charge in the bootstrap capacitor. And the value of the bootstrap capacitor should be increased as the switching frequency decreases. A charge pump circuit can be used to overcome the problems. This paper deals with an analysis and design of a charge pump circuit for the floating gate power supply of an IPM. The simulation and experiment are carried out for an induction motor drive system. The results well verifies the validity of the proposed circuit and design method.

Design of Charge Pump Circuit for Intelligent Power Module of Floating Gate Power Supply (Intelligent Power Module의 플로팅 게이트 전원 공급을 위한 전하 펌프 회로의 설계)

  • Lim, Jeong-Gyu;Kim, Seok-Hwan;Seo, Eun-Kyung;Chung, Se-Kyo
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.421-423
    • /
    • 2005
  • A bootstrap circuit for floating power supply has the advantage of being simple and inexpensive. However, the duty cycle and on-time are limited by the requirement to refresh the charge in the bootstrap capacitor. Hence, this paper deals with a design of charge pump circuit for a floating gate power supply of an IPM. The operation of the proposed circuit applied by three-phase inverter system for driving induction motor are verified through the experiments.

  • PDF

Development of Floating Power Supply for Current Measurement System of High Voltage Power Line

  • Oota, Ichirou;Hattori, Hiroaki;Nishiyama, Eiji;Matsuda, Toyonori;Kawano, Mitsunori;Kuwanami, Kenji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.88.5-88
    • /
    • 2002
  • A new floating power supply for the current measurement system of a high voltage power line is developed. It is confirmed that, the current measurement system can stably transfer the signal of the power line current about 50 - 300 A by using the proposed power supply. The excellent characteristics are obtained by the steady-state and transient experiments of the proposed circuit. $\textbullet$ The right figure shows the external view of the trial measurement system for 6.6 kV. In order to see the inside, 120 degrees of the insulator is cut. The toroidal coil for the power supply and the Rogowskii coil for the current sensor are both divided into two and fixed on the power line as...$\textbullet$ The proposed circuit can supply +5V and -5V voltages without using a solar cell and/or a battery.

  • PDF

Dynamic Response of Floating Green Hydrogen Production System with Various Connection Power Cable Outer Diameters Under Operating Conditions (운영중인 부유식 그린 수소 생산 시스템의 연결 전력 케이블 외경 변화에 따른 동적 거동 평가)

  • Seung Mo Kim;Woo Chul Chung
    • Journal of Wind Energy
    • /
    • v.15 no.3
    • /
    • pp.62-71
    • /
    • 2024
  • A floating green hydrogen production platform is considered a suitable facility for the hydrogen supply chain in the future. In this study, we analyzed the dynamic behavior of a floating green hydrogen production platform according to changes in the outer diameter of the connecting power cable. The platform consists of a floater that generates hydrogen and an offshore wind turbine, and a connection power cable is attached to the floater to supply the electric power produced by the offshore wind turbine. In this study, it was found that variations of the outer diameter of the connection power cable had a minor effect on the dynamic behavior on the floater, and the larger the outer diameter of the connecting power cable, the greater the effective tension. As a result, it was found that the outer diameter of the cable was not a major variable in the entire production system design.

A Study on Gate driver with Boot-strap chain to Drive Multi-level PDP Driver Application (Multi-level PDP 구동회로를 위한 Gate driver의 Boot-strap chain에 관한 연구)

  • Nam, Won-Seok;Hong, Sung-Soo;SaKong, Suk-Chin;Roh, Chung-Wook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.120-126
    • /
    • 2006
  • A gate driver with Boot-strap chain is proposed to drive Multi-level PDP sustain switches. The proposed gate driver uses only one boot-strap capacitor and one diode per each MOSFETs switch without floating power supply. By adoption of this gate driver circuits, the size, weight and the cost of the driver board can be reduced.

A floating resistor with positive and negative resistance operating at lower supply voltages

  • Tantry, Shashidhar;Oura, Takao;Yoneyama, Teru;Asai, Hideki
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.325-328
    • /
    • 2002
  • In this paper. we propose a floating resistor with positive and negative resistance operating at lower supply voltages. The circuit uses only two transistors between the supply voltages. which enable to operate it at low supply voltages. Moreover. the circuit uses fewer number of transistors compared to the reported work. The gate terminal is used in this circuit for the current addition/subraction at the terminals of resistor. The characteristic of the proposed circuit is verified using HSPICE for the power supply +/-1.5V.

  • PDF

Planning research for Floating Power Plant by modifying LNG carriers (LNG선 개조 발전플랜트 기획연구)

  • Lee, Kangki;Bae, Jaeryu;Shin, Jaewoong;Park, Jongbok
    • Plant Journal
    • /
    • v.16 no.3
    • /
    • pp.37-41
    • /
    • 2020
  • Lately old LNG carriers increased and ship price is getting down. So Interest for reuse and modification of used LNG carriers is growing. Also the needs for replacement of old power plant is increasing. Additionally eco friendly fuel such as LNG become attractive. Consequently gas power plant is getting much more popular than before. So in this research planning, we consider the floating power plant by modifying LNG carriers. This plant has the various function including storage, power plant and bunkering fuction etc. Through this multifunctional plant, we are ready for the old power plant shutdown and energy crisis in the future when we can supply the urgent mobile floating power plant quickly in time.

Calculation of Appropriate Subsidies for Energy Storage System to Improve Power Self-sufficiency Consider Microgrid Operation (마이크로그리드 운영에 따른 전력자립 향상을 위한 에너지저장장치의 적정보조금 산정)

  • Choi, Yeon-Ju;Kim, Sung-Yul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.3
    • /
    • pp.486-492
    • /
    • 2017
  • In recent years, renewable energy sources have been mentioned as solution to environmental regulation and energy supply-demand. Energy storage systems are needed to mitigate the intermittent output characteristics of renewable energy sources and to operate micro grid efficiently using renewable energy generation systems. However, despite the necessity of energy storage system, this cannot secure the economical efficiency of the energy storage system by high initial cost. In this paper, a micro grid is constructed to supply electric power to industrial customers by using solar power generation system and energy storage system among renewable energy generation power sources and operated to improve energy independence. In the case study, we use photovoltaic system which is representative renewable energy generation system. Unlike conventional photovoltaic system, this system uses floating photovoltaic system with the advantage of having high output and no land area limitations. It is operated for the purpose of improving energy independence in the micro grid. In order to secure economical efficiency, the energy storage system operates a micro grid with a minimum capacity. Finally, this paper calculates the appropriate subsidy for the energy storage capacity.