• 제목/요약/키워드: Floating power supply

검색결과 37건 처리시간 0.023초

Floating Power Supply Based on Bootstrap Operation for Three-Level Neutral-Point-Clamped Voltage-Source Inverter

  • Nguyen, Qui Tu Vo;Lee, Dong-Choon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.3-4
    • /
    • 2011
  • This paper presents a survey of floating power supply based on bootstrap operation for three-level voltage-source inverters. The floating power supply for upper switches is achieved by the bootstrap capacitor charged during on-time of the switch underneath. Hence, a large number of bulky isolated DC/DC power supplies for each gate driver are reduced. The Pspice simulation results show the behavior of bootstrap devices and the performance of bootstrap capacitor voltage.

  • PDF

Intelligent Power Module의 플로팅 게이트 전원 공급을 위한 전하 펌프 회로의 설계 (Design of Charge Pump Circuit for Floating Gate Power Supply of Intelligent Power Module)

  • 임정규;정세교
    • 전력전자학회논문지
    • /
    • 제13권2호
    • /
    • pp.135-144
    • /
    • 2008
  • 일반적으로 Intelligent power module (IPM)의 상부 스위치 구동을 위한 플로팅 전원 공급 방법으로 부트스트랩 회로가 많이 사용되고 있다. 부트스트랩 회로는 구성이 간단하고 집적화가 가능하다는 장점이 있으나 몇 가지 문제점을 가지고 있다. 상부 스위치 게이트 드라이버 회로에 전원을 공급하기 위해 매 주기마다 충분한 에너지를 충전할 수 있는 시간이 요구되며, 충전된 에너지는 한정적이므로 스위치 턴 온 (turn-on)시간의 제한을 갖게 된다. 그리고 주파수가 낮아질수록 부트스트랩 커패시터 용량이 증가하여 집적화에 장애요인이 된다. 이러한 단점은 전하 펌프 회로를 사용함으로써 보완될 수 있다. 본 논문에서는 IPM의 플로팅 전원 공급 방법으로 전하 펌프 회로를 적용하여 분석하였으며, 이러한 분석을 기반으로 전하 펌프 회로의 설계 방법을 제안하였다. 분석과 제안된 설계 방법의 타당성을 검증하기 위하여 시뮬레이션과 실험을 수행하였으며, 제시된 결과는 제안된 설계 방법의 유용성을 입증하였다.

Intelligent Power Module의 플로팅 게이트 전원 공급을 위한 전하 펌프 회로의 설계 (Design of Charge Pump Circuit for Intelligent Power Module of Floating Gate Power Supply)

  • 임정규;김석환;서은경;정세교
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.421-423
    • /
    • 2005
  • A bootstrap circuit for floating power supply has the advantage of being simple and inexpensive. However, the duty cycle and on-time are limited by the requirement to refresh the charge in the bootstrap capacitor. Hence, this paper deals with a design of charge pump circuit for a floating gate power supply of an IPM. The operation of the proposed circuit applied by three-phase inverter system for driving induction motor are verified through the experiments.

  • PDF

Development of Floating Power Supply for Current Measurement System of High Voltage Power Line

  • Oota, Ichirou;Hattori, Hiroaki;Nishiyama, Eiji;Matsuda, Toyonori;Kawano, Mitsunori;Kuwanami, Kenji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.88.5-88
    • /
    • 2002
  • A new floating power supply for the current measurement system of a high voltage power line is developed. It is confirmed that, the current measurement system can stably transfer the signal of the power line current about 50 - 300 A by using the proposed power supply. The excellent characteristics are obtained by the steady-state and transient experiments of the proposed circuit. $\textbullet$ The right figure shows the external view of the trial measurement system for 6.6 kV. In order to see the inside, 120 degrees of the insulator is cut. The toroidal coil for the power supply and the Rogowskii coil for the current sensor are both divided into two and fixed on the power line as...$\textbullet$ The proposed circuit can supply +5V and -5V voltages without using a solar cell and/or a battery.

  • PDF

Multi-level PDP 구동회로를 위한 Gate driver의 Boot-strap chain에 관한 연구 (A Study on Gate driver with Boot-strap chain to Drive Multi-level PDP Driver Application)

  • 남원석;홍성수;사공석진;노정욱
    • 전력전자학회논문지
    • /
    • 제11권2호
    • /
    • pp.120-126
    • /
    • 2006
  • 본 논문에서는 Multi-level PDP 구동회로의 Sustain 스위치를 구동하기 위해 Boot-strap chain 방식의 Gate driver를 제안한다. 제안된 Gate driver는 한 개의 High-side N-MOSFETS를 구동하기 위해 별도의 Floating power supply 가 필요치 않고 한 쌍의 다이오드와 캐패시터만을 사용한다. 제안 Gate driver 회로를 적용함으로서, Multi-level PDP driver의 가격과 무게 및 부피를 줄일 수 있다.

A floating resistor with positive and negative resistance operating at lower supply voltages

  • Tantry, Shashidhar;Oura, Takao;Yoneyama, Teru;Asai, Hideki
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -1
    • /
    • pp.325-328
    • /
    • 2002
  • In this paper. we propose a floating resistor with positive and negative resistance operating at lower supply voltages. The circuit uses only two transistors between the supply voltages. which enable to operate it at low supply voltages. Moreover. the circuit uses fewer number of transistors compared to the reported work. The gate terminal is used in this circuit for the current addition/subraction at the terminals of resistor. The characteristic of the proposed circuit is verified using HSPICE for the power supply +/-1.5V.

  • PDF

LNG선 개조 발전플랜트 기획연구 (Planning research for Floating Power Plant by modifying LNG carriers)

  • 이강기;배재류;신재웅;박종복
    • 플랜트 저널
    • /
    • 제16권3호
    • /
    • pp.37-41
    • /
    • 2020
  • 최근 노후화된 LNG선박의 증가, 선박가격 하락으로 중고 LNG선 재활용 가능성이 증대되고 있다.또한 노후발전소 대체관련 Needs가 늘고 있으며 가스생산량 증가 및 친환경 연료가 각광받고 있어 가스 발전플랜트 매력도도 상승하고 있다. 이에 본 연구에서는 중고 LNG선을 개조하여 LNG저장 및 발전플랜트 기능을 갖추게 하고 이밖에 재기화기능,벙커링 기능을 갖춘 복합기능 플랜트에 대한 기획연구를 수행하였다.이를 통해 노후 화력발전 중단,원전해체 등으로 인한 에너지 공백을 대체하고 국가 위기사태에 이동형 발전 플랜트를 긴급으로 투입가능해지며 대북 경협 등 정책에 새로운 대안으로 활용할 수 있다.

마이크로그리드 운영에 따른 전력자립 향상을 위한 에너지저장장치의 적정보조금 산정 (Calculation of Appropriate Subsidies for Energy Storage System to Improve Power Self-sufficiency Consider Microgrid Operation)

  • 최연주;김성열
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.486-492
    • /
    • 2017
  • In recent years, renewable energy sources have been mentioned as solution to environmental regulation and energy supply-demand. Energy storage systems are needed to mitigate the intermittent output characteristics of renewable energy sources and to operate micro grid efficiently using renewable energy generation systems. However, despite the necessity of energy storage system, this cannot secure the economical efficiency of the energy storage system by high initial cost. In this paper, a micro grid is constructed to supply electric power to industrial customers by using solar power generation system and energy storage system among renewable energy generation power sources and operated to improve energy independence. In the case study, we use photovoltaic system which is representative renewable energy generation system. Unlike conventional photovoltaic system, this system uses floating photovoltaic system with the advantage of having high output and no land area limitations. It is operated for the purpose of improving energy independence in the micro grid. In order to secure economical efficiency, the energy storage system operates a micro grid with a minimum capacity. Finally, this paper calculates the appropriate subsidy for the energy storage capacity.

Floating Inverter Amplifiers with Enhanced Voltage Gains Employing Cross-Coupled Body Biasing

  • Jae Hoon Shim
    • 센서학회지
    • /
    • 제33권1호
    • /
    • pp.12-17
    • /
    • 2024
  • Floating inverter amplifiers (FIAs) have recently garnered considerable attention owing to their high energy efficiency and inherent resilience to input common-mode voltages and process-voltage-temperature variations. Since the voltage gain of a simple FIA is low, it is typically cascaded or cascoded to achieve a higher voltage gain. However, cascading poses stability concerns in closed-loop applications, while cascoding limits the output swing. This study introduces a gain-enhanced FIA that features cross-coupled body biasing. Through simulations, it is demonstrated that the proposed FIA designed using a 28-nm complementary metal-oxide-semiconductor technology with a 1-V power supply can achieve a high voltage gain (> 90 dB) suitable for dynamic open-loop applications. The proposed FIA can also be used as a closed-loop amplifier by adjusting the amount of positive feedback due to the cross-coupled body biasing. The capability of achieving a high gain with minimum-length devices makes the proposed FIA a promising candidate for low-power, high-speed sensor interface systems.