• 제목/요약/키워드: Floating floor

검색결과 79건 처리시간 0.028초

철도차량용 방진고무의 동특성 평가 및 상구조 차음 성능 증대를 위한 적용 (Evaluation of rubber spring for rail vehicle and application on the floor for increasing sound insulation properties)

  • 이태욱;김종년;이화수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.778-782
    • /
    • 2004
  • Floating floor structure, which is mainly adopted for reducing interior noise of railway vehicle, is known that it is superior to single wall in respect of sound transmission loss. The dynamic characteristic of the support in the floating floor that is one of the important design variables in floating floor structure can change the sound and vibration insulation properties of it. From excitation test, the dynamic stiffness and loss factor of the support are evaluated. They are used as input parameter for analyzing the sound transmission loss of floating floor. Predicted transmission loss is compared with the prototype-car test results.

  • PDF

EVA와 경질우레탄폼을 이용한 표준바닥구조 벽식-5용 단열완충재 개발 (The Development of Damping Material for Standard Floating Floor Type-5 Using Ethylene Vinyl Acetate co-polymer(EVA) & Urethane Form)

  • 박철용;김상훈;장동운;장철호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.461-464
    • /
    • 2004
  • The reduction effect of floor impact noise depends on the various factors such as stiffness and thickness of the concrete slab, finishing If ceiling materials and the composition method. Among the rest it is well known that floating floor system is more effective. Standard floating floor(SFF) type-2 consisted of 50mm lightweight aerated concrete(LAC) and 20mm damping material has been widely used. But LAC construction problem on dry damping material occurred and the reduction effect of floor impact noise has bare minimum qualifications. Thus the aim of this study is to develop 40mm composite damping material(Soundzero Plus) for SFF type-5 which substitute LAC and damping material. 'Soundzero Plus' is satisfied with quality requirement for damping material for SFF. The heat transition rate, $0.45W/m^2{\cdot}K$ is more effective 55% about than the regulation. The test results of floor impact noise by using 'Soundzero Plus' are showed good improvement about 12dB (tested by tapping machine) and 4dB (tested by bang machine) between before and after.

  • PDF

共同住宅 뜬바닥構造의 바닥 衝擊音레벨 測定 (Measurements of the floor impact sound level for floating screeds in apartment house)

  • 박병전;신영무
    • 한국음향학회지
    • /
    • 제11권2호
    • /
    • pp.38-49
    • /
    • 1992
  • 고체음은 건축음향에서 가장 중요한 인자의 하나이다. 그럼에도 불구하고 건축음향설계에서 그 거동을 예측하는 연구는 아직 찾아볼 수 없는 실정이다. 여기에 바닥충격음 제어의 가장 확실한 방법중의 하나인 콘크리트 뜬바닥구조를 개발하여, 이 구조의 층ㅇ격음 차단성능을 기존바닥과 비교하고자 한다. 이를 위하여 5개소에 21개 샘플을 시공하고 그 성능을 KS F 2810의 규정에 따라 측정하였으며, 비교분석은 차음등급의 기준주파수 특성을 쓰고, JIS A 1419의 규정에 의해 구한 차음등급에 따랐다. 결과는 표 3.1의 번호 12의 구조이외는 크게 바닥충격음의 개선효과를 기대할 수 없었고 기타는 자료의 축적에 뜻이 있다 하겠다.

  • PDF

선박 격실 mock-Up을 이용한 뜬바닥구조의 소음.진동 저감효과 계측에 관한 연구 (A Study on Noise and Vibration Reduction Measurements of a Floating Floor Structure by means of a Ship Cabin Mock-up)

  • 김현실;김재승;강현주;김봉기;김상렬
    • 대한조선학회논문집
    • /
    • 제45권6호
    • /
    • pp.719-725
    • /
    • 2008
  • In this paper, noise and vibration reduction for floating-floored ship cabin is studied. A mock-up is built by using 6 mm steel plate, and two identical cabins are made for simulation of ship cabins. When a speaker is used as a sound and vibration sources, it is shown that floating floor is more effective in isolating sound than bare deck by 2-5 dB. It is also shown that structure-borne noise of the bare deck is greater than that of floating-floored deck by 3-10 dB. For tapping machine excitation, it is found that the effect of floating floor in airborne noise and structure-borne noise reduction reaches up to 40-50 dB for high frequency ranges.

뜬바닥구조를 이용한 선박 격실의 소음.진동 저감에 관한 연구 (A Study on the Reduction of Noise and Vibration in Ship Cabins by Using floating Floor)

  • 김현실;김재승;강현주;김봉기;김상렬
    • 한국소음진동공학회논문집
    • /
    • 제16권9호
    • /
    • pp.949-957
    • /
    • 2006
  • In this Paper, reduction of noise and vibration in ship cabins by using floating floor is studied. Two theoretical models are presented and predicted insertion losses of floating floor are compared to experimental results, where measurements have been done in mock-up built for simulating typical ship cabin structures. In ships, mineral wool is usually used as the impact absorbing materials. The first model (M-S-Plate Model) is that upper plate and mineral wool are assumed as a one-dimensional mass-spring system, which is in turn attached to the simply supported elastic floor. The second model (Wave-Plate Model) is that mineral wool is assumed as an elastic medium for wave propagation. The comparisons show that M-S-Plate model is in good agreement with experimental results when density of mineral wool is 140K, and fiber direction is horizontal. For higher density and vertical fiber direction, Wave-Plate model shows good agreements with measurements. It is found that including the elastic behavior of the floor is essential in improving accuracy of the prediction for low frequency ranges below $100{sim}200Hz$.

SEA 기법을 이용한 부유상구조의 구조기인 소음 예측 (Prediction of Structure-Borne Noise for Floating Floor Using SEA)

  • 박희준;우관제
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.258-264
    • /
    • 2007
  • Floating floors, which are mainly used for reducing interior noise levels of railway vehicle, are known to be superior to single structure in respect to sound transmission loss and vibration reduction performances. The stiffness of isolator is one of the important design variables in floating floors. From modal tests, modal properties of underframe, top floor and isolators are derived. They are used as input parameters for predicting structure-borne noise using AUTOSEA.

  • PDF

철도차량에서 사용하는 부유상구조의 진동절연특성에 관한 연구 (Study on the Vibration Reduction Characteristics of Floating Floors Used in Railway Vehicles)

  • 우관제;박희준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.305-309
    • /
    • 2006
  • In this paper vibration reduction characteristics of floating floors used in railway vehicles are studied. Vibration reduction characteristics are compared through a series of tests for elastically-coupled floor and rigidly-coupled floor. It was found that elastically-coupled floor has larger vibration reduction amount than rigidly-coupled floor. Around the fundamental natural frequency, however, elastic floor has poor vibration reduction effect than rigid floor. Measures to reduce structure-borne noise are also discussed based on the test results. Structure-borne noise for running railway vehicles cannot be reduced by an effort to deviate resonance between natural frequency of floors and major exciting forces. Instead, reducing vibration level of top floor and using covers which have low sound radiation coefficient will be effective for reducing structure-borne noise.

  • PDF

콘크리트 슬래브와 바닥 상부구조가 일체된 바닥구조의 바닥충격음 (Floor Impact Noise Level for Concrete Slab Integrated with Floor Finishing Layers)

  • 문대호;오양기;정갑철;박홍근
    • 한국소음진동공학회논문집
    • /
    • 제26권2호
    • /
    • pp.130-140
    • /
    • 2016
  • Floating floor is most commonly used at apartment houses in Korea for thermal insulation and reducing impact noise. But it in proven that the floating floor is not effective for reducing the floor impact noise in low frequency range. In most cases, impact sound pressure level under 63 Hz frequency band were actually increased by the resonance of resilient material, lightweight concrete and the finishing mortar installed on it. In this paper, an integrated floor system consist of 70 mm light weight concrete and 40 mm finishing mortar successively installed on the concrete slab was suggested to avoid the resonance. Integrated floor system increases total flexural stiffness and mass per unit area. The natural frequencies of first and second vibration mode were increased and acceleration response and floor impact sound level was decreased in all measurement range.

우레탄 보드를 활용한 옥상 뜬바닥 구조공법의 휨강도에 관한 기초적 실험 (Foundational Experiments about Bending Strength of Floating Floor Method on Roof-top by using a Polyurethane Board)

  • 박길범;박준모;김옥규;정일기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.15-16
    • /
    • 2016
  • The roof-top of deteriorated building is necessary to improve that performance of waterproof and heat insulation is lowered. However, the existing method is difficult to supply due to complicated process and high cost. Therefore, practical condition and demand for occupant considered, it is necessary to develop inexpensive and easy method, such as a floating floor method using thermal insulation. This study is experiments on foundational experiment was conducted on the bending strength. A polyurethane board for experiment forms a square and it has various size that 25cm, 33cm, 50cm, and 100cm. Meanwhile, the uniform load of 200kg/㎡ which general working load is applied to the bending strength.

  • PDF

공동주택 경량 바닥충격음 저감성능 예측을 위한 바닥마감재 간이측정 방법 연구 (Research on simple measurement method of floor finishing materials to predict lightweight floor impact noise reduction performance in apartment houses)

  • 강민우;오양기
    • 한국음향학회지
    • /
    • 제42권6호
    • /
    • pp.594-602
    • /
    • 2023
  • 현재까지 바닥충격음은 중량 바닥충격음 연구가 주를 이루었다. 경량 바닥충격음의 경우 뜬 바닥구조만으로 충분히 차단성능을 확보할 수 있었기 때문이었다. 뜬 바닥구조에서 중량 바닥충격음의 경우 바닥완충재의 동탄성 측정을 통해 저감성능을 어느 정도 예측할 수 있다. 하지만 최근 사후 확인 제도의 도입으로 인해 다양한 바닥구조가 개발되고 있다. 특히, 완충재가 사용되지 않는 바닥구조에서는 경량 바닥충격음에 지대한 영향을 미치는 것이 바닥마감재이다. 하지만 바닥마감재에 대한 탄성이나 물성을 측정하여 경량바닥충격음을 효과적으로 저감 하기 위한 연구는 부족한 실정이다. 이 연구에서는 사후 확인 제도 도입 이후 중요해 질 수 있는 바닥마감재의 경량바닥충격음 저감성능 예측하고자 하였다. 공동주택 바닥마감재로 사용되는 다양한 재료를 선정하여 실제 실험실에서 경량바닥충격음 차음성능을 측정하고 간이 실험으로 진동 전달특성 파악을 통해 경량바닥충격음 예측 가능성을 확인하고자 하였다.