• 제목/요약/키워드: Flexure load

검색결과 223건 처리시간 0.028초

피에조 구동형 2축 스테이지의 설계 및 해석 (Design and Analysis of Two-Axis Stage Driven by Piezoelectric elements)

  • 류성훈;한창수;최기봉
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.742-745
    • /
    • 2003
  • Piezoelectric elements driven ultra-precision stages have been used for high accuracy, fast response and high load rapacity. which are allowable to apply the stages to AFMs. Most of the piezoelectric driven stages are guided by flexure hinges for force transmission and mechanical amplification. However the flexure hinge mechanisms cause lack of position accuracy due to coupled and parasitic motions. Hence it is important that the mechanism design of the stage is focused on the stiffness of the flexure hinges to accomplish fast response and hish accuracy without the coupled and parasitic motions. In this study, some constraints for optimal design of a piezoelectric elements driven stage and a design method are proposed. Next, an optimal design is carried out using mathematical calculation. Finally the designed results are verified by FEM.

  • PDF

철근콘크리트 원형 교각의 전단성능에 대한 횡방향철근의 영향 (Effect of Transverse Steel on Shear Performance for RC Bridge Columns)

  • 고성현
    • 한국지진공학회논문집
    • /
    • 제25권5호
    • /
    • pp.191-199
    • /
    • 2021
  • In seismic design, hollow section concrete columns offer advantages by reducing the weight and seismic mass compared to concrete section RC bridge columns. However, the flexure-shear behavior and spirals strain of hollow section concrete columns are not well-understood. Octagonal RC bridge columns of a small-scale model were tested under cyclic lateral load with constant axial load. The volumetric ratio of the transverse spiral hoop of all specimens is 0.00206. The test results showed that the structural performance of the hollow specimen, such as the initial crack pattern, initial stiffness, and diagonal crack pattern, was comparable to that of the solid specimen. However, the lateral strength and ultimate displacement of the hollow specimen noticeably decreased after the drift ratio of 3%. The columns showed flexure-shear failure at the final stage. Analytical and experimental investigations are presented in this study to understand a correlation confinement steel ratio with neutral axis and a correlation between the strain of spirals and the shear resistance capacity of steel in hollow and solid section concrete columns. Furthermore, shear strength components (Vc, V, Vp) and concrete stress were investigated.

Evaluation of Crack Propagation and Post-cracking Hinge-type Behavior in the Flexural Response of Steel Fiber Reinforced Concrete

  • Gali, Sahith;Subramaniam, Kolluru V.L.
    • International Journal of Concrete Structures and Materials
    • /
    • 제11권2호
    • /
    • pp.365-375
    • /
    • 2017
  • An experimental evaluation of crack propagation and post-cracking behavior in steel fiber reinforced concrete (SFRC) beams, using full-field displacements obtained from the digital image correlation technique is presented. Surface displacements and strains during the fracture test of notched SFRC beams with volume fractions ($V_f$) of steel fibers equal to 0.5 and 0.75% are analyzed. An analysis procedure for determining the crack opening width over the depth of the beam during crack propagation in the flexure test is presented. The crack opening width is established as a function of the crack tip opening displacement and the residual flexural strength of SFRC beams. The softening in the post-peak load response is associated with the rapid surface crack propagation for small increases in crack tip opening displacement. The load recovery in the flexural response of SFRC is associated with a hinge-type behavior in the beam. For the stress gradient produced by flexure, the hinge is established before load recovery is initiated. The resistance provided by the fibers to the opening of the hinge produces the load recovery in the flexural response.

Torsional analysis of a single-bent leaf flexure

  • Nguyen, Nghia Huu;Lim, Byoung-Duk;Lee, Dong-Yeon
    • Structural Engineering and Mechanics
    • /
    • 제54권1호
    • /
    • pp.189-198
    • /
    • 2015
  • We present a torsion analysis of single-bent leaf flexure that is partially restrained, subject to a torsional load. The theoretical equations for the torsional angle are derived using Castigliano's theorem. These equations consider the partially restrained warping, and are verified using finite element analysis (FEA). A sensitivity analysis over the length, width, and thickness is performed and verified via FEA. The results show that the errors between the theory result and the FEA result are lower than 6%. This indicates that the proposed theoretical torsional analysis with partially restrained warping is sufficiently accurate.

수동형 음강성 저주파 제진기의 감쇠 성능 향상과 빔 유연체의 최적 설계에 관한 연구 (A Study on the improvement of damping and optimal design of beam flexure for the passive vibration isolator)

  • 이길용;장희도;박영호;박인황;한동철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.189-195
    • /
    • 2008
  • The vibration isolator system(VIS) which has very low natural frequency could be designed by applying an axial compressive force to the beam-column flexure(BCF). In this paper a new shape of the BCF is suggested. It has stepwise axially varying properties by viscoelastic damping layer. So it has internal structural damping by damping layer during deformation. First the analytic solution is obtained for the BCF. And its critical load, buckling mode, stiffness and stress distributions are investigated. Also the dynamic properties of the VIS consist of the damping layered BCF are studied. Finally the optimal design procedure of damping layered BCF for the VIS is suggested. The improved performance of suggested VIS is verified by some experiments.

  • PDF

CFRP 적층판의 동적 층간파괴인성의 평가법 (A Study on the Estimation of Dynamic Interlaminar Fracture Toughness on CFRP Laminates Plates)

  • 김지훈;김영남;판부직규;양인영
    • 한국자동차공학회논문집
    • /
    • 제6권2호
    • /
    • pp.80-91
    • /
    • 1998
  • In this paper, the estimation of dynamic interlaminar fracture toughness on fracture mode II in CFRP(carbon fiber reinforced plastics) laminates in made. Dynamic ENF(End Notched Flexure) apparatus used in this paper is manufactured by suing Split Hopkinson Pressure Bar. The static and impact load history in the CFRP specimen is measured by using manufactured dynamic ENF tester and 3-point bending test is carried out to find the load history. Also dynamic interlaminar fracture toughness can be found by using the J integral obrained from dynamic analysis in consideration of intertia-force effect.

  • PDF

Review of Design Flexural Strengths of Steel-Concrete Composite Beams for Building Structures

  • Chung, Lan;Lim, Jong-Jin;Hwang, Hyeon-Jong;Eom, Tae-Sung
    • International Journal of Concrete Structures and Materials
    • /
    • 제10권sup3호
    • /
    • pp.109-121
    • /
    • 2016
  • Recently, as the use of high-performance materials and complex composite methods has increased, the need for advanced design specifications for steel-concrete composite structures has grown. In this study, various design provisions for ultimate flexural strengths of composite beams were reviewed. Design provisions reviewed included the load and resistance factor design method of AISC 360-10 and the partial factor methods of KSSC-KCI, Eurocode 4 and JSCE 2009. The design moment strengths of composite beams were calculated according to each design specification and the variation of the calculated strengths with design variables was investigated. Furthermore, the relationships between the deformation capacity and resistance factor for flexure were examined quantitatively. Results showed that the design strength and resistance factor for flexure of composite beams were substantially affected by the design formats and variables.

반복 횡하중을 받는 원형교각의 휨-전단 거동 (Flexure-Shear Behavior of Circular Bridge Columns under Cyclic Lateral Loads)

  • 이재훈;고성현;이대형;정영수
    • 콘크리트학회논문집
    • /
    • 제16권6호
    • /
    • pp.823-832
    • /
    • 2004
  • 본 연구는 지진하중을 받는 교각의 휨-전단 거동 파악을 목적으로 한다. 실물크기 원형기둥 실험체 4개를 제작하여 일정한 축력 하에서 반복횡하중을 가력하는 실험을 수행하였다. 실험체의 주요변수는 형상비(1.825, 2.5, 4.0), 횡방향철근 형상, 축방향 철근비이다. 모든 실험체의 횡방향 후프띠철근 체적비는 소성힌지 구간에서 0.0023의 값을 갖는다. 이 값은 도로교설계기준에서 요구하는 최소 심부구속철근 요구량의 $24\%$에 해당하며, 이는 내진설계가 되지 않은 기존 교각이나 한정연성설계개념으로 설계되는 교각을 나타낸다. 실험체는 실험변수에 따라 휨파괴나 휨-전단 파괴거동을 보였다. 본 논문에서는 실험결과에 따른 파괴거동과 내진성능을 분석하였다.

반응표면법을 이용한 광학미러용 일체형 유연힌지 마운트 최적설계 (Optimal Design of the Monolithic Flexure Mount for Optical Mirror Using Response Surface Method)

  • 이경호;남병욱;남성식
    • 한국군사과학기술학회지
    • /
    • 제26권3호
    • /
    • pp.205-213
    • /
    • 2023
  • An optimal design of a simple beam-shaped flexure hinge mount supporting an optical mirror is presented. An optical mirror assembly is an opto-mechanically coupled system as the optical and mechanical behaviors interact. This side-supporting mount is flexible in the radial direction and rigid for the remaining degrees of freedom to support the mirror without transferring thermal load. Through thermo-elastic, optical and eigenvalue analysis, opto-mechanical performance was predicted to establish the objective functions for optimization. The key design parameters for this flexure are the thickness and length. To find the optimal values of design parameters, response surface analysis was performed using the design of experiment based on nested FCD. Optimal design candidates were derived from the response surface analysis, and the optimal design shape was confirmed through Opto-mechanical performance validation analysis.

Pontic Design에 따른 임시가공의치의 파절강도에 관한 연구 (FLEXURE STRENGTH OF ACRYLIC RESIN TEMPORARY BRIDGE BY PONTIC DESIGN)

  • 오상천;진태호;동진근
    • 대한치과보철학회지
    • /
    • 제30권1호
    • /
    • pp.65-72
    • /
    • 1992
  • The purpose of this study was to evaluate the flexure stregth of posterior 4-unit acrylic resin bridge with different pontic designs : 1) Conventional pontic 2) Hygienic pontic and 3) Modified hygienic pontic. All specimens were made of self-curing acrylic resin for provisional restorations. Self-curing acrylic resin was filled in a silicone mold by the drop-on technique ; and was polymerized in a pressure spot under 20 psi pressure. The test specimens which were simply shaped posterior 4-unit bridge were 38mm ion 4mm wide, and 35mm thick(connector : 3mm thick). Each specimen was subjected to an increasing load of Instron machine with its tip centered on the specimen at 90-degree angle, and the machine was operated with its load cell of 50kg and its crosshead speed, 2mm/minute : and then the load values at the moment of the fracture of them were recorded. This study was also performed to analyze their stress distributions by the finite element method. The obtained results were as follows : 1. Flexure strength of the hygienic pontic(9.78kg) and the modified hygienic pontic(10.17kg) was higher than that of conventional pontic(6.96kg). But no significant difference was found between the hygienci pontic and the. modified hygienic pontic. The above statistic values were appraised by ANOVA and Duncan's multiple range test 2. Stress was concentrated on the middle portion in every group : and the stress of conventional pontic was found the greatest of all pontic designs.

  • PDF