• Title/Summary/Keyword: Flexible tube

Search Result 131, Processing Time 0.021 seconds

585-nm Pulsed Dye Laser Treatment of Vocal Polyp (585-nm Pulsed Dye LASER를 이용한 성대 폴립의 치료)

  • Choi, Hong-Shik;Lee, Kun-Wayn;Kim, Min-Ho;Kwon, Soon-Ho;Jeon, Ju-Hyun;Kim, Kwang-Moon
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.18 no.1
    • /
    • pp.44-50
    • /
    • 2007
  • Background and Objectives: The 585-nm pulsed dye laser (PDL) has recently been adopted by otolaryngologists because of its epithelial-sparing properties. Many authors have reported the use of PDL for treatment of various vocal cord lesions. This purpose of this study is to examine the effectiveness of 585-nm PDL in the treatment of vocal polyp. Materials and Methods: Eight patients with vocal polyp were treated with 585-nm PDL from Sep. 2006 to Nov. 2006 in Yong-dong Sevrance hospital. 5 of them went through local anesthesia and 3 of them went through general anesthesia. In order to control laser fiber, flexible digital transnasal laryngoscope was applied under local anesthesia and general anesthesia using LMA, and micromanipulator was used under general anesthesia using endotracheal tube. The evaluations of vocal function was done at pre-and postoperation. Results: All patients improved in the perceptual evaluation of voice after PDL surgery. The aerodynamic study revealed that 5 of 8 patients showed improvement in maximal phonation time, and 6 of 8 showed improvement in mean airflow rate during phonation. The acoustic analysis revealed that all patients showed improvement in Jitter and Shimmer, and 7 of 8 showed improvement in noise to harmony ratio. Conclusion: This study demonstrates promising results in the efficacy of 585-nm PDL for the treatment of vocal polyps, and it illustrates a new option for vocal polyp treatment as well as the advantage of PDL surgery.

  • PDF

Airway Management with Reinforced Laryngeal in Mask Airway in a Child with Hypoplastic Left Heart Syndrome (좌심실형성부전증후군 환아의 치과치료를 위한 전신마취 시 강화 후두마스크를 이용한 기도 유지)

  • Kim, Kyung Jin;Shin, Teo-Jeon;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Chong-Chul;Seo, Kwang-Suk
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.13 no.4
    • /
    • pp.221-224
    • /
    • 2013
  • Despite the laryngeal mask airway (LMA) has been widely used in anesthesia, its use is rare in the field of dentistry. Placing LMA in the oral cavity may interrupt dental treatment. However, there are some circumstances in which LMA is more advantageous than tracheal intubation for managing the airway. Especially, the reinforced LMA has a flexible tube shaft, rendering it more accessible for dental treatment. We report a case of dental treatment of a 3-year-old patient with hypoplastic left heart syndrome combined with pulmonary hypertension using reinforced LMA for airway management under general anesthesia. We also discuss the considerations of utilizing the reinforced LMA for dental treatment.

Eigen-Frequency of a Cantilever Beam Restrained with Added Mass and Spring at Free End or a Node Point (자유단 혹은 노드점에 작용하는 스프링과 부가질량을 받는 일단 지지보의 고유진동수)

  • Sim, Woo-Gun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.32-40
    • /
    • 2018
  • In order to avoid excessive vibration, it is required to carry out a vibration analysis of heat-exchanger/nuclear-reactor at the design stage. Information of eigen-frequency in the vibration problem is required to evaluate safety of heat-exchange/nuclear reactor. This paper describes a numerical method, Galerkin's method, to solve the eigenvalue problem occurred in a cantilever beam. The beam is restrained with added mass and spring at the free end or a node point of a mode shape. The numerical results of eigen-frequency were compared with simple analytical and experimental results given by simple approach and simple test, respectively. It is found that Galerkin's method is applicable to estimate the eigen-frequency of the cantilever beam. The frequencies become lower with increasing the added mass and the frequencies increase with the spring force. It is shown the heavy added mass has a role of support on the flexible tube. The eigen-frequency of the first mode, for the system with the added mass mounted at the free end, can be calculated by the approximate analytical method existing with more or less accuracy.

Optimum Design of Dynamic Vibration Absorber for Reducing Bending Vibrations of Two-Piece Vehicle Drive Line (2축 분할식 차량 구동라인의 굽힘진동 저감을 위한 동흡진기 최적설계)

  • Lee, Sang-Beom;Yoo, Young-Sun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.2
    • /
    • pp.118-124
    • /
    • 2010
  • In this paper, design parameters of dynamic vibration absorber, which is used to reduce bending vibrations of a vehicle drive line, is optimized. For obtaining the correct dynamic response characteristics, a flexible-body drive line is made by applying the flexibility data extracted from vibration analysis of propeller shafts to the drive line dynamic model. Inner tube mass, rubber stiffness and rubber damping coefficient of the dynamic vibration absorber are taken as design parameters for optimization. To minimize the vertical acceleration of the drive line, a second-order regression equation of the objective function is generated by performing the central composite experimental design with 3 factors, 2 levels and 15 test runs. And the design parameters of the dynamic vibration absorber are determined by using optimization program. The vehicle model with optimized dynamic vibration absorber reduces the vertical acceleration peak of the drive line by 17.1 % in compared with the initial model.

Mechanical Performance Study of Piggy Back Clamp for Submarine Cables (해저케이블용 피기백 클램프의 기계적 성능 연구)

  • Yun Jae Kim;Kyeong Soo Ahn;Jin-wook Choe;Jinseok Lim;Sung Woong Choi
    • Composites Research
    • /
    • v.37 no.2
    • /
    • pp.108-114
    • /
    • 2024
  • Due to the continuously increasing global demand for electricity, the demand for high-voltage submarine cables is also increasing. One of the issues that need to be addressed for submarine cables is the high production cost and expensive laying costs. Submarine cables exposed to the marine environment encounter external forces such as wave and current, leading to issues such as cable damage due to external factors or high maintenance costs in the event of an accident. Therefore, we are preparing for the uncertainty of the submarine environment through many protective materials and protective equipment. In this study, we examined the bending performance of piggyback clamps (PBC) and strap, which are representative protective equipment, in response to the submarine environment through analytical methods. To examine the structural performance of PBC, the bending performance were assessed under the maximum bending moment criterion of 15 kN·m for the flexible protection tube. As a result, it was confirmed that the structural performance regarding the bending moment of both PBC and straps was ensured.

REPLACEMENT OF A PHOTOMULTIPLIER TUBE IN A 2-INCH THALLIUM-DOPED SODIUM IODIDE GAMMA SPECTROMETER WITH SILICON PHOTOMULTIPLIERS AND A LIGHT GUIDE

  • KIM, CHANKYU;KIM, HYOUNGTAEK;KIM, JONGYUL;LEE, CHAEHUN;YOO, HYUNJUN;KANG, DONG UK;CHO, MINSIK;KIM, MYUNG SOO;LEE, DAEHEE;KIM, YEWON;LIM, KYUNG TAEK;YANG, SHIYOUNG;CHO, GYUSEONG
    • Nuclear Engineering and Technology
    • /
    • v.47 no.4
    • /
    • pp.479-487
    • /
    • 2015
  • The thallium-doped sodium iodide [NaI(Tl)] scintillation detector is preferred as a gamma spectrometer in many fields because of its general advantages. A silicon photomultiplier (SiPM) has recently been developed and its application area has been expanded as an alternative to photomultiplier tubes (PMTs). It has merits such as a low operating voltage, compact size, cheap production cost, and magnetic resonance compatibility. In this study, an array of SiPMs is used to develop an NaI(Tl) gamma spectrometer. To maintain detection efficiency, a commercial NaI(Tl) $2^{\prime}{\times}2^{\prime}$ scintillator is used, and a light guide is used for the transport and collection of generated photons from the scintillator to the SiPMs without loss. The test light guides were fabricated with polymethyl methacrylate and reflective materials. The gamma spectrometer systems were set up and included light guides. Through a series of measurements, the characteristics of the light guides and the proposed gamma spectrometer were evaluated. Simulation of the light collection was accomplished using the DETECT 97 code (A. Levin, E. Hoskinson, and C. Moison, University of Michigan, USA) to analyze the measurement results. The system, which included SiPMs and the light guide, achieved 14.11% full width at half maximum energy resolution at 662 keV.

Performance Evaluation of Underground Pipe with In-Situ Recycled Controlled Low Strength Materials (현장발생토사 재활용 유동성채움재를 이용한 지하매설관의 거동평가)

  • Lee Kwan-Ho;Song Chang-Seob
    • International Journal of Highway Engineering
    • /
    • v.8 no.2 s.28
    • /
    • pp.1-12
    • /
    • 2006
  • An existing Steel pipe, Cast iron pipe and Concrete pipe is can not escaped from aging, specially Metal tube is causing many problems that the quality of water worse is concerned about many rust and mike efficient use of preservation of water. The use of Glassfiber Reinforced Plastic Pipe(GRP PIPE) should be one of the possible scheme to get over these problems. The GRP PIPE has an excellent resistance power and the life is lasting from 50 to 100 years roughly. It's to be useful as a result of high durability and a good construction work also it is a light weight therefore can be expected to short the time of construction and man power. In this research, to executed the small-scaled model test, in-situ model test using CLSM of in-situ soil and to evaluated the stress - strain of the pipe also try to estimated how useful is. From the model test in laboratory, the vertical and horizontal deformation of the GRP PIPE measured in six instance using 200mm and 300mm in diameters. The value of experimentation, theory, analysis got the same results of the test, but the vertical and horizontal deformation gauged in small and the earth pressure was almost zero using CLSM of in-situ soil..

  • PDF

Evaluating Joint Motion Sensing Efficiency According to the Implementation Method of CNT-Based Fabric Sensors (CNT 기반의 직물센서 구현 방법에 따른 관절동작 센싱 효율 평가)

  • Cho, Hyun-Seung;Yang, Jin-Hee;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.24 no.4
    • /
    • pp.129-138
    • /
    • 2021
  • This study aimed to determine the effects of the shape and attachment position of stretchable textile sensors coated with carbon nanotube on their performance when used to measure children's joint movements. Moreover, the child-safe requirements for fabric motion sensors are established. The child participants were advised to wear integrated clothing equipped with the sensors of various shapes (rectangular and boat-shaped) and attachment positions (at the knee and elbow joints or 4 cm below the joints). The voltage change induced by the elongation and contraction of the fabric sensors was determined for arm and leg flexion-extension motions at 60 deg/s (three measurements of 10 repeats each for 60°and 90°angles, for a total of 60 repetitions). Their dependability was determined by comparing the fabric motion sensors to the associated acceleration sensors. The experimental results indicate that the rectangular-shaped sensor affixed 4 cm below the joint is the most effective fabric motion sensor for measuring children's arm and leg motions. In this study, we designed a textile sensor capable of tracking children's joint motion and analyzed the sensor shape and attachment position on motion sensing clothing. We demonstrated that flexible fabric sensors integrated into garments may be used to detect the joint motions of the human body.

Improvement of Consolidation Characteristics around PVD Using the Thermal Method (열적 방법을 이용한 연직배수재 주변의 압밀특성 연구)

  • Bergado, Dennes T.;Shin, Eun-Chul;Park, Jeong-Jun
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.10
    • /
    • pp.5-11
    • /
    • 2007
  • This paper is to investigate the removal of the smear at elevated temperatures. This study utilized both small cylinder cell and large consolidometer apparatus to investigate the combination of PVD with heat and without heat. Two types of heaters are used in this study. The heater drain made of copper tube is used for all tests except large consolidometer and flexible wire heater is used for large consolidometer. Specimens demonstrated volume contraction upon heat and without heat. This contraction is dependent on temperature magnitude. When the specimen is heated, the magnitude of settlements is higher and rate of consolidation is faster. After treatment using PVD combined without heat and with heat for undisturbed specimens the $C_h$ values obtained were $3.45m^2/yr$ and $3.83m^2/yr$, respectively, from $3.2m^2/yr$ before treatment. The $K_h/K_s$ ratios were 3 for the specimen without heat and 2 for the specimen with heat. Similarly, in reconstituted specimens without heat and with heat, the $C_h$ values were $2.1m^2/yr$ and $2.5m^2/yr$ with $K_h/K_s$ ratios of 1.75 and 1.5, respectively.

Treatment of Potassium Titanyl Phosphate Laser and Radiation Therapv for Tracheal Stenosis (기관 협착에서 레이저와 방사선 치료의 적용)

  • 김광택;김맹호
    • Journal of Chest Surgery
    • /
    • v.30 no.12
    • /
    • pp.1237-1241
    • /
    • 1997
  • Tracheal stenosis is a difficult disease entity to manage. Laser ablation is one effective treatment for treacheal stenosis and can be utilized if tracheal reconstructive surgery is impossible. Potassium titanyl phosphate laser, transmitted via flexible quartz fiber, can be precisely manipulated through flexible bronchoscope under local anesthesia. We treated 7 patients with trach al and broncheal lesion under local anesthesia with KTP laser from January 1995 to July 1996. The patients included three males and four females. The age of patients ranged from 22 to 66 years with a mean of 43.7 years The etiology of tracheal stenosis in patients was stenosis after tracheostomy(3 cases), prolong inturbation in cases of sepsis(1 cases), and the recurrence of lung cancer within endobronchial lesion(2 cases). In the cases of tracheal stenosis treated with laser ablation, there were 2 cases of recurrence of stenosis at the anastomosis site after the operation, 3 cases of stenosis at tracheostomy site, and 2 cases of local recurrence of lung cancer. The site of the tracheal stenosis was the balloon site of the tracheostomy tube(3-4cm inferior to the tracheostomy site, 2-3cm superior to the carina) and the anastomosis site that were narrowed to less than 5mm(4 cases). For the stenosis lesion in the endobronchial area, there were 2 patients with a lesion at the anterior wa l, 1 patient with a lesion at the posterior wall, 2 patients with circumferential stenosis. Laser ablation time was 25.4 $\pm$5.9min and used energy was 1768 $\pm$365J. We have used KTP laser via (lexible bronchoscope without major complications. Adjuvant radiation therapy may prevent fibroblast proliferation which leads to restenosis. In three patients of restenosis after laser ablation, adjuvant irradiation started within 4 hours after laser ablation, and the radiation doses were 1500cGy given in five fraction. In patients with adjuvant radiation therapy, stenosis has not recurred

  • PDF