• Title/Summary/Keyword: Flexible Wall

Search Result 206, Processing Time 0.03 seconds

양이온 물질로 오염된 지하수 정화를 위한 반응벽체 개발 : 제올라이트의 적용성 평가

  • 이승학;이재원;김시현;박준범;박상권
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.23-26
    • /
    • 2001
  • Batch test and column test were performed to develop the design factors for PRBs against the contaminated groundwater by ammonium and lead. Clinoptilolite, one of the natural zeolites having excellent cation exchange capacity(CEC), was chosen as the reactive material through the ion-exchange mechanism. In the batch test, the reactivity of Clinoptilolite to ammonium and lead was examined with varying the particle size of Clinoptilolite. The nit weight of Clinoptilolite showed removal efficiencies of 65 % against the ammonium and 98% against lead. The effect of particle size of Clinoptilolite was not noticeable. In the column test, the permeability was examined using flexible-wall permeameters with varying the particle size of Clinoptilolite. When the washed Clinoptilolite having the diameter of 0.42-0.85 nm was mixed with Jumunjin sands in 20:80 ratio (w/w), the highest permeability of 2$\times$10$^{-3}$ -7 x 10$^{-4}$ cm/s was achieved. The reactivity and the strength property of the mixed material were investigated using fixed wall column having 8 sampling ports on the wall and the direct shear test, respectively. Clinoptilolite was found to be a suitable material for PRBs against the contaminated groundwater with ammonium and/or heavy metals.

  • PDF

Carbon nanotube based transparent electrodes for flexible displays using liquid crystal devices

  • Shin, Jun-Ho;Lee, H.C.;Lee, J.H.;Park, S.M.;Alegaonkar, P.S.;Yoo, J.B.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.897-899
    • /
    • 2007
  • Transparent electrodes for a flexible display based on the liquid crystal (LC) were formed by carbon nanotubes (CNTs) on polyethylene terephthalate (PET) substrates. The thin multi wall carbon nanotubes (t-MWNTs) networks for electrodes were obtained by filtration- transfer method from welldispersed CNTs solution.

  • PDF

Numerical Investigation for the Optimization of Two-Dimensional Adaptive Wall (2차원 적응벽면의 최적화에 관한 수치적 연구)

  • Chang B. H.;Chang K. S.
    • Journal of computational fluids engineering
    • /
    • v.1 no.1
    • /
    • pp.134-141
    • /
    • 1996
  • Wall interference is one of the major obstacles to increase the model size and data accuracy. There have been many treatments for wall interference including interference correction and adaptive wall test section. Recently, two-flexible-walled adaptive wall test section is concluded adequate for three-dimensional test. But proper location of target line and pressure holes are critical to its success. In this study, a new adaptive algorithm which dispenses target line and dependency of pressure hole distribution is suggested. The wind tunnel and free air tests are simulated by the numerical computation of Euler equations. The optimum wall shape is achieved by two variable optimization which is composed of two base streamlines. The wall interference is reduced well in the optimized result which is not sensitive to the base streamlines.

  • PDF

Innovative approach to determine the minimum wall thickness of flexible buried pipes

  • Alzabeebee, Saif;Chapman, David N.;Faramarzi, Asaad
    • Geomechanics and Engineering
    • /
    • v.15 no.2
    • /
    • pp.755-767
    • /
    • 2018
  • This paper uses a finite element based approach to provide a comprehensive understanding to the behaviour and the design performance of buried uPVC pipes with different diameters. It also investigates pipes with good and poor haunch support and proposes minimum safe wall thicknesses for these pipes. The results for pipes with good haunch support showed that the maximum pipe wall stress and deformation increase as the diameter increased. The results for pipes with poor haunch support showed an increase in the dependency of the developed vertical displacement on the haunch support as the diameter or the backfill height increased. Additionally, poor haunch support was found to increase the soil pressure, with the effect increasing as the diameter increased. The design of uPVC pipes for both poor and good haunch support was found to be governed by critical buckling. A key outcome is a new design chart for the minimum wall thickness, which enables the robust and economic design of buried uPVC pipes. Importantly, the methodology adopted in this study can also be applied to the design of flexible pipes manufactured from other materials, buried under different conditions and subjected to different loading arrangements.

New Manufacture Process Technology of Flexible Flat Lighting used LED (LED를 이용한 플렉시블 면 조명의 신 제조 공정기술 개발)

  • Youn, Shin-Yong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.2
    • /
    • pp.142-150
    • /
    • 2016
  • This paper developed new manufacture process technology of slim type flexible flat lighting product used lower power white LED. Flexible flat lighting is applied to letter sign lighting, traffic lighting, interior wall lighting, flat lighting, aquarium back lighting, wreath light etc. Main manufacture process technology were developed drawing software for electronics circuit, inkjet electronic circuit pattern and inkjet white ink coating. For pattern printing it was utilized for piezoelectonic inkjet head printing technology. Also high vacuum pressure laminating technology was waterproofing for LED flat lighting protection. Hence, form process technology we were manufactured for flexible flat lighting product of the power 12 W, input voltage 48 V and plane size $480{\times}480mm$. It acquired a these validity from experiment results.

Consideration on Design and Management of Flexible Hose through the Case Study of Chlorine Leak (염소 누출 사고사례연구를 통한 Flexible hose 설계 및 관리 방안 고찰)

  • Park, Suyoul;Yim, Ji-pyo
    • Korean Chemical Engineering Research
    • /
    • v.57 no.3
    • /
    • pp.351-357
    • /
    • 2019
  • This research was performed to propose domestic standard for design and management of flexible hose by analyzing chlorine leak caused by breakage of the hose in Ulsan, 2018. The leak had multiple causes but this paper focuses on analyzing the cause of breakage of flexible hose, the direct cause. According to the analysis, flexible hose that the company of the accident used for chlorine transfer was inappropriate in several aspects including material and wall thickness. And even pressure test had been conducted below operating pressure. Upon investigation on five companies that handle chlorine in Ulsan, four companies were using inappropriate flexible hose for chlorine transfer. Since there is no domestic standard for the design of flexible hose for chlorine transfer at present, it is hard to examine its design adequacy. Design standard of flexible hose used in chlorine transfer that is applicable domestically is proposed based on this research. It will contribute to the reduction in risk of breakage of the hose if the proposed standard could be applied in design and examination of flexible hose.

Direct imposition of the wall boundary condition for simulating free surface flows in SPH

  • Park, Hyung-Jun;Seo, Hyun-Duk;Lee, Phill-Seung
    • Structural Engineering and Mechanics
    • /
    • v.78 no.4
    • /
    • pp.497-518
    • /
    • 2021
  • In this study, a new method for treating the wall boundary in smoothed particle hydrodynamics (SPH) is proposed to simulate free surface flows effectively. Unlike conventional methods of wall boundary treatment through boundary particles, in the proposed method, the wall boundary condition is directly imposed by adding boundary truncation terms to the mass and momentum conservation equations. Thus, boundary particles are not used in boundary modeling. Doing so, the wall boundary condition is accurately imposed, boundary modeling is simplified, and computation is made efficient without losing stability in SPH. Performance of the proposed method is demonstrated through several numerical examples: dam break, dam break with a wedge, sloshing, inclined bed, cross-lever rotation, pulsating tank and sloshing with a flexible baffle. These results are compared with available experimental results, analytical solutions, and results obtained using the boundary particle method.

Prediction of Long-Term behavior of polyethylene pipe buried underground (지중매설 폴리에틸렌 관의 장기거동 예측)

  • Lee, Jae-Ho;Kim, Bin;Yoon, Soo-Hyun;Kim, Eung-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.1
    • /
    • pp.7-12
    • /
    • 2017
  • Most of existing buried pipes are composed of reinforced concrete. Reinforced concrete pipes have many problems such as aging, corrosion, leaking, etc. The polyethylene (PE) pipes have advantages to solve these problems. The plastic pipes buried underground are classified into a flexible pipe. National standard that has limited the long-term vertical deformation of the pipe to 5% for flexible pipes including PE pipe. This study presents a prediction for the long-term behavior of the polyethylene pipe based on ASTM D 5365. This prediction method is presented to estimate by using the statistical method from the initial deflection measurement data. We predict the behavior of long-term performance on the double-wall pipe and multi-wall pipe. As a result, it was found that the PE pipe will be sound enough more than 50 years if the compaction of soil around the pipe is more than 95% of the standard soil compaction density.

Remediation for Hydrophobic Organic Compound Contaminated Soils by Surfactant Solution (계면활성제 용액을 이용한 소수성 유기화합물로 오염된 토양의 정화)

  • 윤현석;박민균;권오정;박준범
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.543-550
    • /
    • 1999
  • Hazardous substances produced from industrial sectors have caused serious contamination of soils and groundwater. The hydrophobic organic compounds in the subsurface are hard to be decomposed, and as they soil on the soil or last as a NAPL they might contaminate the groundwater for a long time. Although we recognize the danger of contaminated subsurface, very little was known about the effective remediation technique. This paper focuses on the remediation of the p-Cresol which contaminated subsurface by applying the surfactant-enhanced description technique. Sorption characteristics of soils and organic compounds are studied, and the applications of surfactant solution are studied for effective rededication. The results from this study could be used as some data for surfactant-enhanced rededication. The flexible-wall permeameter tests are performed in which in-situ remediation is simulated. Results show that triton X-100 at 2% solution disrobes p-Cresol 1.7 times as much as water description in the flexible-wall permeameter tests.

  • PDF

Permeability and Consolidation Characteristics on Clayey Sand Soils (점토질 모래의 투수 및 압밀 특성 평가)

  • Kim, Kwang-Kyun;Park, Du-Hee;Chang, Jae-Hoon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.971-980
    • /
    • 2010
  • Evaluation of permeability and coefficient of consolidation of clayey sand is critical to analyze ground stability or environmental problems such as diffusion and dispersion in groundwater flow. Permeability tests using a flexible wall permeameter were performed to derive the coefficient of consolidation and permeability of reconstituted soil samples with various mixing ratios of kaolin clays and two different types of sands, Jumunjin sand and Ottawa sand. The test results indicated that coefficient of consolidation and permeability in log scale have linear relationships with clay contents in low clay mixing ratio. It is also recognized that coefficient of consolidation and permeability of sand and clay mixture are also dependent on the soil structure.

  • PDF