파력발전장치 공기실 내 왕복유동장 해석 (Internal Oscillating Flow Field Analysis in Air Chamber of Wave Energy Conversion)

  • 문재승;현범수;홍기용;신승호;김길원
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.427-430
    • /
    • 2006
  • This paper deals with the internal oscillating flaw in air chamber and duct of an OWC-type wave energy converter by numerical analysis using commercial CFD code, FLUENT. Whole oscillating flaw from OWC-type chamber to outlet through duct was solved by unsteady analysis in order that performance of wave energy conversion was made better. Results show that whole oscillating flaw field of this system in unsteady condition. Duct shape at setting place of turbine is curved with elbow, because profile of inlet condition to turbine is important in its efficiency. This paper is found internal flaw in air chamber and duct. Also, this research was found effect of duct shape.

  • PDF

Application of wavelet transform for the impulse response of pile

  • Ni, Sheng-Huoo;Yang, Yu-Zhang;Lyu, Chia-Rong
    • Smart Structures and Systems
    • /
    • 제19권5호
    • /
    • pp.513-521
    • /
    • 2017
  • The purpose of this paper is to study the capabilities of the impulse response method in length and flaw detecting for concrete piles and provide a suggested method to find small-size flaws in piles. In this work, wavelet transform is used to decompose the recorded time domain signal into a series of levels. These levels are narrowband, so the mix of different dominant bandwidths can be avoided. In this study, the impulse response method is used to analyze the signal obtained from the wavelet transform to improve the judgment of the flaw signal so as to detect the flaw location. This study provides a new way of thinking in non-destructive testing detection. The results show that the length of a pile is easy to be detected in the traditional reflection time or frequency domain method. However, the small flaws within pile are difficult to be found using these methods. The proposed approach in this paper is able to greatly improve the results of small-size flaw detection within piles by reducing the effects of any noise and clarifying the signal in the frequency domains.

Application of the Leak Before Break(LBB) Concept to a Heat Exchanger in a Nuclear Power Plant

  • Kwon, Jae-Do;Lee, Choon-Yeol;Lee, Yong-Son;Sul, Il-Chan
    • Journal of Mechanical Science and Technology
    • /
    • 제15권1호
    • /
    • pp.10-20
    • /
    • 2001
  • The leak before break(LBB) concept is difficult to apply to a structure with a thin tube that is immersed in a water environment. A heat exchanger in a nuclear power plant is such a structure. The present paper addresses an application of the LBB concept to a heat exchanger in a nuclear power plant. The minimum leaked coolant amount(approximately 37.9 liters) containing the radioactive material which can activate the radiation detector device installed in near the heat exchanger is assumed. A postulated initial flaw size that can not grow to a critical flaw size within the time period to activate the radiation detector is justified. In this case, the radiation detector can activate the warning signal caused by coolant leakage from initially postulated flaws of the heat exchanger. The nuclear plant can safely shutdown when this occurs. Since the postulated initial flaw size can not grow to the critical flaw size, the structural integrity of the heat exchanger is not impeded. Particularly the informational scenario presented in this paper discusses an actual nuclear plant.

  • PDF

아파트 지하주차장의 균열방지 대책 - 현장사례조사를 중심으로 - (A Study on the Flaw Prevention Countermeasure of Crack in Apartment House Underground Parking Area)

  • 정순오;서상욱
    • 한국건설관리학회논문집
    • /
    • 제3권1호
    • /
    • pp.115-123
    • /
    • 2002
  • 공간의 효율적 이용 및 법정 주차대수 확보 등으로 아파트 단지의 지하층은 대부분 지하주차장으로 활용되고 있으며, 주차장상부도 시공 중에 성토 및 포장공사가 완성되지 않은 상태에서 작업차량의 통로 및 자재 야적장으로 사용되고 있어 과하중이 작용되고 있는 실정이다. 그러므로 시공중이거나 완공된 지하구조물에서 지속적으로 균열 및 누수현상이 발생하여 구조물의 성능저하는 물론 많은 금액의 하자보수비 투입, 민원유발 및 대외적인 신뢰도 저하 등 많은 문제점이 발생하고 있다. 따라서 본 연구의 목적은 시공중인 아파트와 준공된 아파트 지하주차장을 대상으로 현장조사를 실시하고, 그동안 실시한 안전진단 사례를 참고하여 아파트 지하주차장의 균열 및 누수현상 원인을 파악하고 그에 따른 설계 및 시공상의 방지대책을 마련하는데 있다.

An Efficient Provable Secure Public Auditing Scheme for Cloud Storage

  • Xu, Chunxiang;Zhang, Yuan;Yu, Yong;Zhang, Xiaojun;Wen, Junwei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제8권11호
    • /
    • pp.4226-4241
    • /
    • 2014
  • Cloud storage provides an easy, cost-effective and reliable way of data management for users without the burden of local data storage and maintenance. Whereas, this new paradigm poses many challenges on integrity and privacy of users' data, since users losing grip on their data after outsourcing the data to the cloud server. In order to address these problems, recently, Worku et al. have proposed an efficient privacy-preserving public auditing scheme for cloud storage. However, in this paper, we point out the security flaw existing in the scheme. An adversary, who is on-line and active, is capable of modifying the outsourced data arbitrarily and avoiding the detection by exploiting the security flaw. To fix this security flaw, we further propose a secure and efficient privacy-preserving public auditing scheme, which makes up the security flaw of Worku et al.'s scheme while retaining all the features. Finally, we give a formal security proof and the performance analysis, they show the proposed scheme has much more advantages over the Worku et al.'s scheme.

DETERMINISTIC EVALUATION OF DELAYED HYDRIDE CRACKING BEHAVIORS IN PHWR PRESSURE TUBES

  • Oh, Young-Jin;Chang, Yoon-Suk
    • Nuclear Engineering and Technology
    • /
    • 제45권2호
    • /
    • pp.265-276
    • /
    • 2013
  • Pressure tubes made of Zr-2.5 wt% Nb alloy are important components consisting reactor coolant pressure boundary of a pressurized heavy water reactor, in which unanticipated through-wall cracks and rupture may occur due to a delayed hydride cracking (DHC). The Canadian Standards Association has provided deterministic and probabilistic structural integrity evaluation procedures to protect pressure tubes against DHC. However, intuitive understanding and subsequent assessment of flaw behaviors are still insufficient due to complex degradation mechanisms and diverse influential parameters of DHC compared with those of stress corrosion cracking and fatigue crack growth phenomena. In the present study, a deterministic flaw assessment program was developed and applied for systematic integrity assessment of the pressure tubes. Based on the examination results dealing with effects of flaw shapes, pressure tube dimensional changes, hydrogen concentrations of pressure tubes and plant operation scenarios, a simple and rough method for effective cooldown operation was proposed to minimize DHC risks. The developed deterministic assessment program for pressure tubes can be used to derive further technical bases for probabilistic damage frequency assessment.

고충전 탄성중합체의 파손평가선도 작성에 관한 연구 (A Study on Failure Assessment Diagrams for a Highly Filled Elastomer)

  • 하재석;김재훈;양호영
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.532-538
    • /
    • 2012
  • 고충전 탄성중합체 균열선단에서의 파괴기구를 분석하였으며, 스트립 항복 모델 및 내재결함 모델이 적용되었다. 두 가지 모델의 수정으로부터 고충전 탄성중합체에 대한 파손평가선도의 작성방법이 연구되었다. 고체로켓연료로 사용되는 고충전 탄성중합체의 인장시험 및 파괴인성시험을 수행하였으며, 시험결과로부터 파손평가선도를 작성하였다. 내재결함 모델로부터 작성한 파손평가선도는 스트립 항복 모델로부터 작성한 파손평가선도와의 비교를 위해 정규화되었다. 두 가지 모델로부터 작성한 파손평가선도를 비교한 결과, 내재결함모델을 이용한 파손평가선도가 스트립항복모델을 이용한 파손평가선도보다 더 보수적으로 파손을 평가하는 것으로 나타났다.

  • PDF

비정질 와이어를 센서헤드로 이용한 금속의 미세결함 검출 (Flaw Detection in a Conductor Using Sensor Head of Amorphous Wire)

  • 김영학;신광호
    • 한국자기학회지
    • /
    • 제12권5호
    • /
    • pp.174-178
    • /
    • 2002
  • 미소결함을 가진 금속체에 교류자기장을 인가하면 결함부근에는 와전류의 분포가 달라져 이에 의해 금속체를 관통하는 교류자기장은 결함부근에서 차이를 가진다. 이 교류자기장을 비정질 와이어로 된 센서헤드로 측정하여 센서헤드의 유기전압 크기로부터 결함 유무를 검출하는 방법에 대해 검토하였다. 비정질 와이어는 Co-based재료로 자왜가 거의 0이며 고투자율 자성체이고 비정질 와이어는 길이가 15mm, 직경이 100$\mu\textrm{m}$인 원주형 자성체이다. 실험대상 금속체로 0.5mm의 단일 직선 갭을 가진 두께 1mm의 동판과 0.1mm의 갭이 규칙적으로 배열된 두께 25$\mu\textrm{m}$의 Al 판를 이용하였다. 스파이럴 코일에 인가하는 교류자기장의 주파수는 100KHz~600KHz였다. 본 실험의 결과에서 동판에서는 유기전압의 최대치와 최소치의 차가 약 2.5㎷ 얻어졌고, Al판에서는 500KHz에서 0.4㎷가 얻어져 직선 갭의 유무를 유기전압의 크기만으로 확인할 수 있었다.

다전극 탐상을 통한 토중 매설배관 피복결함 탐상 정확도의 개선 (Enhancing the Reliability of Coating Flaw Detection for Pipes Buried in Soil Using a Multi-Electrode Detector)

  • 김민기;임부택;김기태;장현영;박흥배;김영식
    • Corrosion Science and Technology
    • /
    • 제19권5호
    • /
    • pp.265-280
    • /
    • 2020
  • External corrosion of buried pipes can be controlled using both coating and cathodic protection. However, deterioration of the coating can occur due to several reasons. The detection reliabilty of coating flaw detection methods is affected by interference such as metal objects connected to rectifiers and copper grids. When performing parallel direct current voltage gradient (DCVG) inspection, a sine wave form without potential reversal in voltage gradient appears in the area where the interference exists. However, this area may be not identified using existing methods. The objective of this study was to determine the effect of analyzing direction on the reliability of coating flaw detection of pipes buried in soil using a multi-electrode detector. DCVG on the buried pipe was measured along the buried pipe. This measurement parallel to the pipe was repeated. Measured data were analyzed for parallel, vertical, and diagonal directions. The reliability of coating flaw detection was improved by up to 46.4% compared to the conventional method.

컴퓨터 내장형 비파괴검사용 초음파탐상기 개발 (Development of Computer Based Ultrasonic Flaw Detector for Nondestructive Testing)

  • 이원흠;김진구;김양래;최관순;김선형;이순흠
    • 비파괴검사학회지
    • /
    • 제17권2호
    • /
    • pp.108-113
    • /
    • 1997
  • 현재 널리 사용되고 있는 비파괴검사중의 하나인 초음파탐상검사(ultrasonic testing)는 교량, 발전소, 석유화학프랜트 및 중공업분야 등에 사용되는 각종 구조물의 사용전 중검사에 폭넓게 응용되고 있으며, 구조물의 안전관리와 품질관리에 필수적으로 요구되고 있다. 또한, 이들 구조물에 존재하는 결함에 대한 정량적 평가 및 검사 데이타의 해석에 많은 연구가 진행되고 있다. 기존의 초음파탐상검사에 사용되는 휴대용 초음파탐상기의 단점을 보안하기 위해 컴퓨터 내장형 초음파탐상기가 선진국에서 개발되고 있으며 다양한 소프트웨어의 사용에 따른 검사 신뢰도가 향상되고 있다. 본 연구는 컴퓨터 내장형 초음파탐상기를 구성하고, 이를 콘트롤할 수 있는 프로그램, 검사 결과의 저장 및 신호 처리 해석이 가능한 소프트웨어를 개발하였다.

  • PDF