• Title/Summary/Keyword: Flatness

Search Result 616, Processing Time 0.024 seconds

A study of Curved Dosimeter for Flattening Filter Free Beam Quality Assurance Evaluation using Curved Dosimeter in Radiotherapy (Flattening Filter Free Beam의 정도관리를 위한 곡면선량계 가능성 연구)

  • Han, Moojae;Shin, Yohan;Jung, Jaehoon;Heo, Seunguk;Kim, Kyotae;Heo, Yeji;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.119-124
    • /
    • 2019
  • Radiation therapy using flattening filter free beam can prevent beam attenuation caused by flattening filter and can improve treatment efficiency. However, accurate dose control is not established for nonuniform iso dose distributions. In this study, curved dosimeter based on photoconductive material $HgI_2$ was fabricated and its reproducibility and linearity were evaluated at 6 MV photon energy to verify its performance. In order to show the usefulness of the curved measurement, the signals measured on the flat substrate and the curved substrate were compared in the flattening filter free beam using the acrylic filter. As a result, the reproducibility of the unit cell dosimeter was evaluated as SE 0.613%, and the linearity was evaluated as R-sq 0.9999. The usability evaluation of the array curve dosimeter demonstrated its usefulness by indicating a curvature error rate of 11.073%p and a reduced error rate.

Development of relative radiometric calibration system for in-situ measurement spectroradiometers (현장관측용 분광 광도계의 상대 검교정 시스템 개발)

  • Oh, Eunsong;Ahn, Ki-Beom;Kang, Hyukmo;Cho, Seong-Ick;Park, Young-Je
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.4
    • /
    • pp.455-464
    • /
    • 2014
  • After launching the Geostationary Ocean Color Imager (GOCI) on June 2010, field campaigns were performed routinely around Korean peninsula to collect in-situ data for calibration and validation. Key measurements in the campaigns are radiometric ones with field radiometers such as Analytical Spectral Devices FieldSpec3 or TriOS RAMSES. The field radiometers must be regularly calibrated. We, in the paper, introduce the optical laboratory built in KOSC and the relative calibration method for in-situ measurement spectroradiometer. The laboratory is equipped with a 20-inch integrating sphere (USS-2000S, LabSphere) in 98% uniformity, a reference spectrometer (MCPD9800, Photal) covering wavelengths from 360 nm to 1100 nm with 1.6 nm spectral resolution, and an optical table ($3600{\times}1500{\times}800mm^3$) having a flatness of ${\pm}0.1mm$. Under constant temperature and humidity maintainance in the room, the reference spectrometer and the in-situ measurement instrument are checked with the same light source in the same distance. From the test of FieldSpec3, we figured out a slight difference among in-situ instruments in blue band range, and also confirmed the sensor spectral performance was changed about 4.41% during 1 year. These results show that the regular calibrations are needed to maintain the field measurement accuracy and thus GOCI data reliability.

Micro-Structure and Magnetic Properties of Electroless Co-W-P Alloy Deposits Formed (무전해 Co-W-P 합금 도금 층의 미세구조와 자기적 특성)

  • Yun, Seong-Ryeol;Han, Seung-Hui;Kim, Chang-Uk
    • Korean Journal of Materials Research
    • /
    • v.10 no.1
    • /
    • pp.97-106
    • /
    • 2000
  • In these respects the purpose of this research is manufacturing Co-W-P alloy thin film on the corning glass 2948 by electroless plating method using $NaH_2PO_2H_2O$ (sodium hypophosphite) as a reductant, and analyzing deposition rate, alloy composition, microstructure, and magnetic characteristics at various pH's and temperatures. For Co-P alloy thin film, the reductive deposition reaction occurred only in basic condition, not in acidic condition. The deposition rate increased as the pH and temperature increased, and the optimum condition was found at the pH of 10 and the temperature of 8$0^{\circ}C$. Also magnetic characteristics was found to be most excellent at the pH of 9 and the temperature of 7$0^{\circ}C$, resulting in the coercive force of 870Oe and the squareness of 0.78. At this condition, the contents of P was 2.54% and the thickness of the film was 0.216$\mu\textrm{m}$. For crystal orientation, we could not observe fcc for $\beta$-Co. On the other hand, (1010), (0002), (1011) orientation of hcp for $\alpha$-Co was observed. We could confirm the formation of longitudinal magnetization from dominant (1010) and (1011) orientation of Co-P alloy. For Co-W-P alloy thin film, coercive force was 500Oe and squareness was 0.6. For crystal orientation, (0002) orientation of $\alpha$-Co was dominatly found. Then we could confirm the formation of perpendicular magnetization. The content of P was constant at 0.8$\pm$0.2% and the content of W increased as the concentration of Na$_2$WO$_4$increased. When the concentration of Na$_2$WO$_4$was 0.1mol/L, the composition of W was 20%. We observed the changes of magnetic characteristics and microstructure of thin film depositions of Co-W-P by the heat treatment. For heat treatment, the temperature was increased step by step to 10$0^{\circ}C$, 20$0^{\circ}C$, 30$0^{\circ}C$, and 40$0^{\circ}C$ and it took 1 hour at each step in the reductive condition of hydrogen gas. By the heat treatment, flatness of surface was improved, but there were no changes on the magnetic characteristics and the microstructures.

  • PDF

Studies on the Morphological, Anatomical and Physiological Characters in Populus alba × glandulosa and its Parent (Populus alba × glandulosa 와 그의 양친종(両親種)의 형태(形態), 해부학(解剖學), 생리학적(生理学的) 연구(硏究))

  • Kim, Chung Suk;Chon, Sang Keun;Hwang, Jin Sung
    • Journal of Korean Society of Forest Science
    • /
    • v.49 no.1
    • /
    • pp.11-31
    • /
    • 1980
  • The morphological, anatomical and physiological traits were eximined for Populus alba ${\times}$ glandulosa which is an important planting species in Korea. The results obtained are as follows: 1. External characters in the leaf shape and chaff shape in the catkin were inherited as incomplete dominance but nectar gland was inherited as dominance. 2. Among the 15 selected clones, 9 clones were male, 2 clones female and 2 clones monoecious. 3. There were well-developed cork layers and bast fiber bundles in the bark. 4. Primordial leaves composed of 3 layers of cells and those undifferentiated into palisade and spongy parenchymas differed in its origin. 5. Leaf scare consisted of two kinds of tissues; one is connected to vascular bundle and the other not to vascular bundle. Tissues which had been connected to vascular bundle were isolated with only 2 or 3 layers of cork cells from the outside. 6. There was complicated arrangement in the vascular bundle of petioles. 7. Growth of the hybrid was sensitively influenced by external temperature, day-length and amount of light. In particular, it was apparent in height growth. 8. Flatness, loam soils and a $60{\times}60cm$ spacing might be best factors for the growth of P. alba ${\times}$ glandulosa. 9. The rooting of 15 clones was dependant upon external factors. 10. The growth of P. alba ${\times}$ glandulosa was best at around 80% of soil moisture content on the basis of plot water capacity. 11. Temperature difference between inside and outside stems below 100cm during the winter was the greatest at the south among seasons and among directions. 12. The sap movement was markedly influenced by air temperature, relative humidity in forest stand and moisture content in stem. 13. Total sugars in the cortex changed with season but did not differ in the dircetion of the stem. 14. Isoperoxidase variations in the leaf were different among 15 clones. Thus, it may be useful as a criterium for clonal identification. 15. The rate of soil moisture content decreased at a rapid slope was faster than that at a slow slope. Poor growth of P. alba ${\times}$ glandulosa at the slope was probably due to depletion of soil moisture.

  • PDF

Customer Acceptance Procedure for Clinac (21EX-Platinum)

  • Hong, Dong-Ki;Lee, Woo-Seok;Kwon, Kyung-Tae;Park, Kwang-Ho;Kim, Chung-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.43-61
    • /
    • 2004
  • Purpose : For qualify improvement in radiotherapy, it is important to set up and evaluate equipment (linac) accurately. In addition, technicians are needed to be fully aware of the equipment's detailed quality and its manual. Therefore, the result of ATP is evaluated and introduced, in order that the technicians are skilled by participating in quality assurance (QA) and understanding the quality of the equipment before clinical use. Method and Material : QA for LINAC 21EX (Varian, US) was done with suppliers its procedure was divided into radiation survey, mechanical test, radiation isocenter test, bean performance, dosimetry, and enhanced dynamic wedge and using X-omat film (Kodak), multidata, densitometer, and electrometer. QA of MLC (Millennium, 120 leaf) attached to LINAC and EPID (Portal vision) were done separately. Result : The leakage dose by survey meter was below the tolerance. In mechanical test, collimater, gantry, and couch rotation were less than 1mm, and the angles were ${\pm}0.1^{\circ}$ for digital and ${\pm}0.5^{\circ}$ for mechanical. The alignment test of the light field and crosshair were evaluated less than 1mm. The (a)symmetrical jaw field was less than ${\pm}0.5mm$. The radiation isocenter test using X-mat film was less than 1mm. The consistency of light field and radiation field was less than ${\pm}0.1mm$. PDD for photon energy was less than ${\pm}1\%$ and for electron energy of $90\%,\;80\%,\;50\%,\;and\;30\%$ were evaluated within the tolerance. Flatness for photon and electron energy was evaluated $2.3\%$ (tolerance $3\%$) and $3\%$ (tolerance $4.5\%$), respectively, and symmetry was $0.45\%$ (tolerance $2\%$) and $0.3\%$ (tolerance $2\%$), respectively. Dosimetry test for short term, MU setting, rep rate, and dose rate accuracy of photon and electron energy was within the tolerance depending on energy, MU, and gantry angle. Conclusion : Accuracy and safety for clinical use of Clinac 21EX was verified through customer acceptance procedure and the quality of the equipment was found out. These can reduce the difficulties in using the equipment. Furthermore, it is useful for clinically treatment of patients by technicians' active participations.

  • PDF

Development of Digital Transceiver Unit for 5G Optical Repeater (5G 광중계기 구동을 위한 디지털 송수신 유닛 설계)

  • Min, Kyoung-Ok;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.25 no.1
    • /
    • pp.156-167
    • /
    • 2021
  • In this paper, we propose a digital transceiver unit design for in-building of 5G optical repeaters that extends the coverage of 5G mobile communication network services and connects to a stable wireless network in a building. The digital transceiver unit for driving the proposed 5G optical repeater is composed of 4 blocks: a signal processing unit, an RF transceiver unit, an optical input/output unit, and a clock generation unit. The signal processing unit plays an important role, such as a combination of a basic operation of the CPRI interface, a 4-channel antenna signal, and response to external control commands. It also transmits and receives high-quality IQ data through the JESD204B interface. CFR and DPD blocks operate to protect the power amplifier. The RF transmitter/receiver converts the RF signal received from the antenna to AD, is transmitted to the signal processing unit through the JESD204B interface, and DA converts the digital signal transmitted from the signal processing unit to the JESD204B interface and transmits the RF signal to the antenna. The optical input/output unit converts an electric signal into an optical signal and transmits it, and converts the optical signal into an electric signal and receives it. The clock generator suppresses jitter of the synchronous clock supplied from the CPRI interface of the optical input/output unit, and supplies a stable synchronous clock to the signal processing unit and the RF transceiver. Before CPRI connection, a local clock is supplied to operate in a CPRI connection ready state. XCZU9CG-2FFVC900I of Xilinx's MPSoC series was used to evaluate the accuracy of the digital transceiver unit for driving the 5G optical repeater proposed in this paper, and Vivado 2018.3 was used as the design tool. The 5G optical repeater digital transceiver unit proposed in this paper converts the 5G RF signal input to the ADC into digital and transmits it to the JIG through CPRI and outputs the downlink data signal received from the JIG through the CPRI to the DAC. And evaluated the performance. The experimental results showed that flatness, Return Loss, Channel Power, ACLR, EVM, Frequency Error, etc. exceeded the target set value.