• 제목/요약/키워드: Flat Tube

검색결과 258건 처리시간 0.037초

튜브 하이드로 피어싱시 롤 오버의 실험적 분석 (Analysis on Roll Over in the Tube Hydro-Piercing Process)

  • 최성기;안익태;문영훈
    • 대한기계학회논문집A
    • /
    • 제28권7호
    • /
    • pp.992-998
    • /
    • 2004
  • During the tube hydropiercing, the region adjacent to the pierced hole will be deformed and will be drawn away from the die block as the punch advances through the wall of the tube. The deformation in the region may range from a substantially flat form to a countersunk form, so called rollover. In this study, the effects of material properties, shape of piercing punches, roundness of tube surface and internal pressure within the tube during piercing on the rollover have been investigated experimentally. The results provide the quantitative variation of rollover at given hydropiercing parameters, and a relationship between the deformed radius and the rollover caused by the deformation has been established.

Evaluation of the 256ch Flat Panel PS-PMT on Positioning Image Histogram for PET

  • Orita, Narimichi;Murayama, Hideo;Kawai, Hideyuki;Inadama, Naoko;Umehara, Takaya;Kasahara, Takehiro;Tsuda, Tomoaki
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.324-327
    • /
    • 2002
  • For a next generation PET that realizes high sensitivity and high resolution, we proposed a design of a depth of interaction detector. A unit of the detector is constructed of four stages rectangular blocks of 2 by 2 Gd$_2$SiO$\sub$5/: Ce (GSO) crystal array optically coupled to position sensitive photomultiplier tube (PS-PMT). The 256ch flat panel PS-PMT is under development by Hamamatsu Photonics K.K., JAPAN. It has large cathode area, 51.7 by 51.7 mm$^2$, and the ratio of the effective area to external size is about 90%. The feature will contribute high packing fraction, accordingly high sensitivity. The 256 anodes are arranged in 16 by 16 at intervals of 3.0 mm. So as to evaluate the detector capability for identifying crystal of interaction, we got positioning image histograms with coupling a 16 by 5 array of GSO crystals, 2.9 by 2.9 by 7.5 mm$^3$, to the PS-PMT by irradiating a gamma ray uniformly from a point source. Flat panel PS-PMT is a new promising device for PET. We need to evaluate it if its performance is sufficiency. The performance was compared to the one with a 16ch PS-PMT.

  • PDF

독립 핀-튜브 열교환기의 열전달 성능특성에 관한 연구 (Study on Heat Transfer Characteristics of Discrete Fin-and-tube Heat Exchangers)

  • 이호성;김용한;최종민;김용찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.274-280
    • /
    • 2005
  • The objective of this study Is to investigate the heat transfer performance of plate discrete fin-and-tube heat exchangers with large fin pitch. In this study, twenty-two heat exchangers were tested with a variation of fin pitch, number of tube row, longitudinal tube pitch and fin alignment. Discrete fin type exchangers improved heat transfer performance more than 10% compared to tile continuous fin type heat exchangers. The air-side heat transfer coefficient decreased with a reduction of the fin pitch and an increase of the number of tube row, The staggered fin alignment improved heat transfer performance more than 6% compared to the inline fin alignment. The effect of longitudinal tube pitch was insignificant on the j-factor and experiments found opposite effects on the j-factor with respect to fin alignment. Heat transfer correlations were developed from the measured data for flat plate discrete fin-and-tube heat exchangers with large fin pitch. The correlations yielded good predictions of the measured data with mean deviations of 1,4% and 0.3% for tire inline and staggered tube alignment, respectively.

  • PDF

국내 저온용 집열기의 열성능 특성 (Thermal Characteristics of Domestic Solar Collector for Low-Temperature Applications)

  • 김정배;이순명;윤응상;이진국;주문창;백남춘
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.215-220
    • /
    • 2008
  • This study shows the results on thermal performance test with domestic solar collector for low-temperature applications using KS, then reveals the efficiency difference between KS and EN standard. Using the test results, this study presents the status of thermal performance with domestic solar collector including flat-plate, single evacuated, and double evacuated (with mirror or U-tube) solar collector.

  • PDF

다채널 편평관의 응축 열전달 및 압력강하특성에 관한 실험 (Experiment on condensation heat transfer and pressure drop characteristics in the multi-channel flat tube)

  • 전창덕;정재원;이진호
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.376-388
    • /
    • 1997
  • In this study, an experiment was performed to investigate the characteristics of pressure drop and heat transfer of multi-channel tubes for automotive condenser using HFC-134a as an alternative refrigerant. The mass flux and inlet saturation pressure of the refrigerant were controlled, respectively, in the range of 200 to $500kg/m^2s$ and 1.0 to 1.6MPa. Pressure drop and heat transfer coefficient were compared with the previously proposed correlations and new correlations based on Traviss' correlation were suggested. Prediction of pressure drop and heat transfer coefficient based on the new correlations agrees with experimental results within ${\pm}9%$ and -18~+11%, respectively.

  • PDF

밀집형 열교환기 내 공기 측 대류열전달특성 (Analysis for Air-Side Convective Heat Transfer Characteristics in Compact Heat Exchangers)

  • 모정하;이상호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1443-1448
    • /
    • 2009
  • Numerical analysis has been carried out to investigate air-side convective heat transfer characteristics in compact heat exchangers with continuous plate fins. Simulation results such as air flow and temperature distributions are presented, and heat transfer characteristics are compared for various inlet conditions. Results from various turbulence models are also compared for applicability. There is large difference between the local heat transfer coefficient distributions along the cylinder wall for circular tubes. Colburn j factors from the calculated results of circular and flat tubes in the heat exchangers are compared for various Reynolds number. The predicted results in this study can be applied to the optimal design of air conditioning system. with compact heat exchanger.

  • PDF

CFD Simulation Tool for Anode-Supported Flat-Tube Solid Oxide Fuel Cell

  • Youssef M. Elsayed.;Lim, Tak-Hyoung;Song, Rak-Hyun;Lee, Seung-Bok;Shin, Dong-Ryul
    • 전기화학회지
    • /
    • 제9권4호
    • /
    • pp.151-157
    • /
    • 2006
  • A two-dimensional numerical model to study the performance of anode-supported flat-tube solid oxide fuel cell (SOFC) far the cross section of the cell in the flow direction of the fuel and air flows is developed. In this model a mass and charge balance, Maxwell-Stefan equation as well as the momentum equation by using, Darcy's law are applied in differential form. The finite element method using FEMLAB commercial software is used for meshing, discritization and solving the system of coupled differential equations. The current density distribution and fuel consumption as well as water production are analyzed. Experimental data is used to verify a predicted voltage-current density and power density versus current density to judge on the model accuracy.

Effect of Inlet Direction on the Refrigerant Distribution in an Aluminum Flat-Tube Heat Exchanger

  • Kim, Nae-Hyun;Kim, Do-Young;Byun, Ho-Won;Choi, Yong-Min
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제16권4호
    • /
    • pp.130-136
    • /
    • 2008
  • The refrigerant R-134a flow distributions are experimentally studied for a round header/ten flat tube test section simulating a brazed aluminum heat exchanger. Three different inlet orientations(parallel, normal, vertical) were investigated. Tests were conducted with downward flow for the mass flux from 70 to 130 $kg/m^2s$ and quality from 0.2 to 0.6. In the test section, tubes were flush-mounted with no protrusion into the header. It is shown that normal and vertical inlet yielded approximately similar flow distribution. At high mass fluxes or high qualities, however, slightly better results were obtained for normal inlet configuration. The flow distribution was worst for the parallel inlet configuration. Possible explanation is provided based on flow visualization results.

Flow Efficiency in Multi-Louvered Fins Having Large Louver-to-Fin Pitch Ratio

  • Kim, Nae-Hyun;Cho, Jin-Pyo;Kim, Do-Young;Kim, Hyun-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권4호
    • /
    • pp.156-162
    • /
    • 2007
  • Flow visualization experiments were conducted for two louver arrays having large louver pitch ratio ($L_p/F_p=1.0$ and 1.4). Flow efficiencies and critical Reynolds numbers were obtained from the data, and were compared with existing correlations. The correlations failed to predict the present flow efficiency data adequately; some correlation overpredicted the data, while others underpredicted the data. Large louver pitch ratio of the present model, which is outside of the applicable range of the correlations may partly be responsible. The critical Reynolds numbers obtained from the present flow visualization data were in close agreement with those obtained from the heat transfer tests on actual flat tube heat exchangers. Existing correlations on the critical Reynolds number generally overpredicted the present data.

금형 냉각이 Al-Mn계 다중압출 평판관의 압출 특성 변화에 미치는 영향 (Effects of die cooling on change of extrusion characteristics of Al-Mn-based thin-walled flat multi-port tube)

  • 신영철;하성호;강태훈;이기안;이승철
    • Design & Manufacturing
    • /
    • 제17권4호
    • /
    • pp.63-71
    • /
    • 2023
  • In order to increase the extrusion production speed of aluminum, extrusion die cooling technology using liquid nitrogen has recently attracted a lot of attention. Increasing the extrusion speed increases the temperature of the bearing area of extrusion dies and the extrusion profile, which may cause defects on the surface of extruded profile. Extrusion die cooling technology is to directly inject liquid nitrogen through a cooling channel formed between the die and the backer inside the die-set. The liquid nitrogen removes heat from the die-set, and gaseous nitrogen at the exit of the channel, covers the extrusion profile of an inert atmosphere reducing the oxidation and the profile temperature. The aim of this study is to evaluate the cooling capacity by applying die cooling to extrusion of Al-Mn-based aluminum alloy flat tubes, and to investigate the effects of die cooling on the change in extrusion characteristics of flat tubes. Cooling capacity was confirmed by observing the temperature change of the extrusion profile depending on whether or not die cooling is applied. To observe changes in material characteristics due to die cooling, surface observation is conducted and microstructure and precipitate analysis are performed by FE-SEM on the surface and longitudinal cross section of the extruded flat tubes.