• Title/Summary/Keyword: Flat Panel Display

Search Result 447, Processing Time 0.027 seconds

The Characteristics of High Temperature Crystallized Poly-Si for Thin Film Transistor Application (박막트랜지스터 응용을 위한 고온 결정화된 다결정실리콘의 특성평가)

  • 김도영;심명석;서창기;이준신
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.5
    • /
    • pp.237-241
    • /
    • 2004
  • Amorphous silicon (a-Si) films are used in a broad range of solar cell, flat panel display, and sensor. Because of the greater ease of deposition and lower processing temperature, thin films are widely used for thin film transistors (TFTs). However, they have lower stability under the exposure of visible light and because of their low field effect mobility ($\mu$$_{FE}$ ) , less than 1 c $m^2$/Vs, they require a driving IC in the external circuits. On the other hand, polycrystalline silicon (poly-Si) thin films have superiority in $\mu$$_{FE}$ and optical stability in comparison to a-Si film. Many researches have been done to obtain high performance poly-Si because conventional methods such as excimer laser annealing, solid phase crystallization and metal induced crystallization have several difficulties to crystallize. In this paper, a new crystallization process using a molybdenum substrate has been proposed. As we use a flexible substrate, high temperature treatment and roll-to-roll process are possible. We have used a high temperature process above 75$0^{\circ}C$ to obtain poly-Si films on molybdenum substrates by a rapid thermal annealing (RTA) of the amorphous silicon (a-Si) layers. The properties of high temperature crystallized poly-Si studied, and poly-Si has been used for the fabrication of TFT. By this method, we are able to achieve high crystal volume fraction as well as high field effect mobility.

A Novel High Precision Electromagnetic Suspension for Long-Stroke Movement and Its Performance Evaluation

  • Lee, Ki-Chang;Moon, Seokhwan;Ha, Hyunuk;Park, Byoung-Gun;Kim, Ji-Won;Baek, Jun-Young;Lee, Min-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.514-522
    • /
    • 2014
  • A new type of high precision electromagnetic suspension (EMS) which can support heavy tray along long stroke rail is proposed in this paper. Compared with the conventional EMS, the suggested moving-core typed EMS has the levitation electromagnets (EMs) on the fixed rail. This scheme has high load capability caused by iron-core and enables simple tray structure. Also it does not have precision degradation caused by heat generation from EMs, which is a drawback of conventional EMS. With these merits, the proposed EMS can be an optimal contactless linear bearing in next generation flat panel display (FPD) manufacturing process if the ability of long stroke movement is proved. So a special Section Switching Algorithm (SSA) is derived from the resultant force and moment equations of the levitated tray which enables long stroke movement of the tray. In order to verify the feasibility of the suggested SSA, a simple test-setup of the EMS with 2 Section-changes is made up and servo-controlled in the simulation and experiment. The simulation shows the perfect changeover the EMs, and the experiment shows overall control performance of under ${\pm}40{\mu}m$ gap deviations. These results reveal that the newly suggested contactless linear bearing can simultaneously achieve high load capability and precision gap control as well as long stroke.

A Study on the Serial-Parallel Resonant DC/DC Converter for Contactless Power Supply System (비접촉 전원장치에 적용한 직.병렬 공진 DC/DC 컨버터에 관한 연구)

  • Hwang, Gye-Ho;Lee, Bong-Sub;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.5
    • /
    • pp.31-40
    • /
    • 2008
  • Recently, Contactless Power Supply(CPS) system has been broadly studied as a power supply system for Flat Panel Display(FPD) material transfer equipments. In mass production line, CPS systems on material transfer equipment are applied only in the straight sections with single operating vehicle. The formal CPS system was not adequate for curved section nor multiple operating vehicles. Therefore, this paper presents CPS system that consists of straight and curved section with multiple operation vehicles. The circuit topology of CPS system consists of full bridge configured serial-parallel resonant DC/DC converter. The control method for CPS system consists of duty control method on the primary power supply system to maintain constant resonant current. And the secondary power supply systems of multiple vehicles are self controled to maintain constant output voltage. Practically, the test result of dual vehicles on straight and curved section of material transfer equipments were satisfactory, and proved it's applicability on commercial use.

A Study on the Development of Pattern Design Tool for CCFL Backlight (CCFL 백라이트 패턴 설계툴 개발에 관한 연구)

  • Cho Young-Chang;Choi Byung-Jin;Yoon Jeong-Oh
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.11 no.2
    • /
    • pp.79-85
    • /
    • 2006
  • As the portable information appliance is developed, the demand of flat panel display equipments and parts are steeply increased. Most of all, the applications of LCD such as LCD TV, monitor, digital camera, CNS(car navigation system) and game machine become diversified. With the result that the number of BLU production enterprise is increased and the research on the design of backlight with the superior optical properties is persistently in progress. In this study we developed the pattern design tools for CCFL(cold cathode flourescent lamp) backlight to improve the conventional pattern design environment in which the pattern is designed manually from the experience and the trial and error. For the verification of our research, we designed the light reflection surface patterns for a real model of backlight and we measured the brightness uniformity using the BM-7. From the brightness uniformity measurement, the BLU designed using the presented tool showed the tolerable performance only in the first try of pattern design rather than the fifth try of pattern design in case of the conventional pattern design.

  • PDF

A study on the of Phosphors most suitable a condition of digital FED (디지털전계방출 디스플레이의 형광체 최적조건에 관한 연구)

  • Kim, Soo-Yong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.4
    • /
    • pp.754-759
    • /
    • 2007
  • Field emission displays (FED) are currently being explored as a potential flat panel display technology. Specifically, the optimization pf efficient bin emitting phosphors in the $Y_2O_3-Nb_2O_5$ system and influence of particle size of phosphors on the luminescent properties was studied. Under 254 nm excitation, Bi activated $YNbO_4$ phosphors showed a strong and relatively narrow blue omission band, peaking at about 420-450 nm. Especially 0.4 wt% Bi doped yttrium phosphors showed the maximum emission intensity which is almost three times as much as that of $Y_2SiO_5:Ce$ phosphors. Finally, Ce doped $Y_2SiO_5$ phosphors exhibited strong and broad blue emission band, centered at 390-420 nm and maximum emission intensity at the doping concentration of 0.02-0.03 mol.

Emission Characteristics of VOCs Distributions in Semiconductor Workplace (반도체 작업환경의 VOCs 농도분포 특성)

  • Lee, Jeong Joo
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.503-509
    • /
    • 2018
  • In this study, a Proton-Transfer Reaction-Time-of-Flight Mass spectrometer (PTR-TOF-MS) was used for the continuous monitoring of Volatile Organic Compounds (VOCs) emitted from semiconductor workplace such as photolithography (PHOTO), flat panel display (FPD), organic light emitting diode (OLED), etching (WET) process. The averaged VOCs mixing ratio in the such workplace, PHOTO was 6.5 ppm, FPH was 6.4 ppm, WET was 2.0 ppm and OLED was 1.3 ppm, respectively. The abundance of VOCs in the workplace were methyl ethyl ketone (MEK) with 2.8 ppm (69%) and acetaldehyde with 0.5 ppm (13.2%). Depending on the semiconductor process characteristics, various VOCs have been observed in the workplace. The VOCs mixing ratio are lower than the workplace regulation standard (TWA), it is necessary to continuously monitor and effectively manage these VOCs.

Safety Schematic Diagram and Sequence of Heater in FPD Wet Equipment (FPD 장비 습식공정에서의 안전한 히터 공급 계통도 및 제어 회로)

  • Yoo, Heung-Ryol;Son, Yung-Deug
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.107-111
    • /
    • 2019
  • In FPD WET equipment, heaters are used a lot. There are many electric accidents caused by short circuit and overheating due to the use of heater, so it is necessary to have a safe electric system and interlock. Therefore, in this paper, we propose an electrical schematic and interlock for FPD WET equipment. In this paper, a hardware interlock such as a level sensor, an overheat protector, and an SSR heater sink is inserted, and the electric system is composed of ELB - MC - SSR - EOCR - heater. When the interlock occurs, the magnetic contactor (MC) is turned off and the power of the heater is cut off.EOCR, an electric overcurrent protection device, has an interlock to shut down the MC when there is an abnormality in the heater while checking the overcurrent, undercurrent and disconnection. These circuit configurations and interlocks are likely to be useful not only for WET equipment but also for any equipment in which the heater is placed.

Development of high-power haptic vibration actuator module and interface based on bidirectional electrostatic force driving structure (양방향 정전기력 구동 구조에 기반한 고출력 햅틱 진동 액추에이터 모듈 및 인터페이스 개발)

  • Kim, Jae-Ik;Lee, Jae-Kyung;Park, Young-Hwan;Seo, Jeong-Tae;Yang, Tae-Heon
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.1
    • /
    • pp.662-667
    • /
    • 2021
  • Vibrotactile feedback is a major function of the latest touch displays, which greatly improves the user's operability and immersion when interacting with the interface on the screen. In this study, we propose a vibrotactile actuator suitable for mounting on the back side of a mid- to large-sized display because it can generate a strong vibration output by applying an electrostatic force-based mechanism and can be manufactured in a thin flat panel type. The proposed actuator was developed in a structure capable of amplifying the vibration force by alternating up and down with electrostatic force by the upper and lower electrodes that are spaced apart from the electrically grounded mass suspended from a radial leaf spring. As a result of the performance evaluation, the developed bar-type module with two built-in actuators showed excellent vibration output of up to 3.3 g at 170 Hz, confirming the possibility of providing haptic feedback in medium and large touch displays.

Assessment of LCD Color Display Performance Based on AAPM TG 18 Protocol : Decision of Quality Control and Calibration Period (판독용 LCD 컬러 모니터 장치의 성능 평가 - 성능 평가 및 Calibration 주기 결정을 중심으로 -)

  • Lee, Won-Hong;Son, Soon-Yong;Noh, Sung-Soon;Lee, In-Hwa;Kang, Sung-Ho;Lee, Yong-Moon;Park, Jae-Soo;Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.55-60
    • /
    • 2008
  • Purpose: This study is to decide a quality control and calibration period of LCD display devices used for reading diagnostic images. Materias and Methods: The assessment test of 20 flat panel LCD color display devices used for reading diagnostic images were performed based on AAPM TG 18 protocol over the total six sessions at one month intervals from three months after primary calibration, in terms of geometric distortion, reflection test, luminance response evaluation, luminance uniformity, resolution, noise, veiling glare and chromaticity test. Results: The results of geometric distortion, reflection test, luminance uniformity, resolution, noise, veiling glare and chromaticity test were within the criteria recommended by AAPM TG 18, except for luminance response evaluation. In the measured luminance deviation of luminance response evaluation, 4(25%) of 20 display devices were passed a criterion from four months after calibration, and 11 (55%) were passed from eight months. Also in the contrast response of the luminance response evaluation, 1(5%) display device was passed a criterion from four months after calibration, and 3(15%) were passed from eight months. Conclusion: Considering the passing deviation after calibration, the time required and a manpower, the quality control and calibration period of LCD display devices used for reading diagnostic images should be a three months and six months after calibration.

  • PDF

Comparative Study of Subjective Mental Workload Assessment Techniques for the Evaluation of ITS-oriented Human-Machine Interface Systems (지능형 교통체계 기반 인간-기계 인터페이스 시스템 평가를 위한 정신적부하 측정방법의 비교 연구)

  • Cha, Doo-Won;Park, Peom
    • Journal of Korean Society of Transportation
    • /
    • v.19 no.3
    • /
    • pp.45-58
    • /
    • 2001
  • Subjective mental workload assessment technique becomes a standard human factors and human-machine interface evaluation tool for the evaluation of ITS(Intelligent Transport Systems)-oriented information systems as well as the drivers visual activity analysis, physiological indices(GSR, EEG, ECG, etc.), secondary task performance, reaction time. vehicle control parameters(speed, steering behavior, accelerator control) that are widely applied for transportation and vehicle systems to evaluate the safety, to decide the system or design alternatives, and to establish the design guidelines. This paper reviewed and compared the most globally employed four mental workload assessment techniques that have been designed for the use of various human-machine systems and ITS-oriented in-vehicle information systems. NASA-TLX(National Aeronautics and Space Administration-Task Load Index). SWAT(Subjective Workload Assessment Technique), MCH(Modified Cooper-Harper) scale, and recently developed RNASA-TLX(Revision of NASA-TH) were compared in terms of sensitivity and subjective evaluations to derive the human-machine interface evaluation guidelines for the application of ITS-oriented in-vehicle information systems. Then, experiment results supported that RNASA-TLX is the prospective tool for the mental workload assessment of ITS-oriented in-vehicle information systems.

  • PDF