• 제목/요약/키워드: Flash point tester

검색결과 76건 처리시간 0.026초

노말테트라데칸의 연소특성치 측정에 의한 위험성 평가 (The Evaluation of Hazard by Measurement of Combustible Characteristics of n-Tetradecane)

  • 하동명
    • 한국안전학회지
    • /
    • 제27권5호
    • /
    • pp.70-76
    • /
    • 2012
  • For the safe handling of n-tetradecane, the lower flash points and the upper flash point, fire point, AITs (auto-ignition temperatures) by ignition delay time were experimented. Also lower and upper explosion limits by using measured the lower and upper flash points for n-tetradecane were calculated. The lower flash points of n-tetradecane by using closed-cup tester were measured $104^{\circ}C$ and $112^{\circ}C$. The lower flash points and fire point of n-tetradecane by using open cup tester were measured $113^{\circ}C$ and $115^{\circ}C$, respectively. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus for n-tetradecane. The experimental AIT of n-tridecane was $207^{\circ}C$. The calculated lower and upper explosion limit by using measured lower $104^{\circ}C$ and upper flash point $140^{\circ}C$ for n-tetradecane were 0.63 Vol.% and 3.18 Vol%.

노말펜타데칸의 화재 및 폭발 특성치의 측정 (The Measurement of Fire and Explosion Properties of n-Pentadecane)

  • 하동명
    • 한국안전학회지
    • /
    • 제28권4호
    • /
    • pp.53-57
    • /
    • 2013
  • For the safe handling of n-pentadecane, the lower flash points and the upper flash point, fire point, AITs(auto-ignition temperatures) by ignition delay time were experimented. Also lower and upper explosion limits by using measured the lower and upper flash points for n-pentadecane were calculated. The lower flash points of n-pentadecane by using closed-cup tester were measured $118^{\circ}C$ and $122^{\circ}C$. The lower flash points and fire point of n-pentadecane by using open cup tester were measured $126^{\circ}C$ and $127^{\circ}C$, respectively. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus for n-pentadecane. The experimental AIT of n-pentadecane was $195^{\circ}C$. The calculated lower and upper explosion limit by using measured lower $118^{\circ}C$ and upper flash point $174^{\circ}C$ for n-pentadecane were 0.54 Vol.% and 6.40 Vol.%.

3-헥사논의 화재 및 폭발 특성치의 측정 및 예측 (Measurement and Prediction of Fire and Explosion Properties of 3-Hexanone)

  • 하동명
    • 한국가스학회지
    • /
    • 제17권6호
    • /
    • pp.33-38
    • /
    • 2013
  • 3-헥사논의 안전한 취급을 위해, 폭발한계는 문헌을 통해 고찰하였고, 인화점과 발화지연시간에 의한 발화온도를 측정하였다. 그 결과, 밀페식 장치에 의한 3-헥사논(에틸프로필케톤)의 하부인화점은 $18^{\circ}C$로 측정되었으며, 개방식에서는 $27^{\circ}C{\sim}32^{\circ}C$로 측정되었다. ASTM E659 장치를 사용하여 자연발화온도와 발화지연시간을 측정하였고, 3-헥사논의 최소자연발화온도는 $425^{\circ}C$로 측정되었다. 측정된 인화점에 의한 폭발하한계는 1.21 Vol%로 계산되었다.

Methanol, Ethanol, 1-propanol 그리고 Toluene 이성분 혼합계에 대한 인화점 측정 (Measurement of Flash Point for Binary Mixtures of Methanol, Ethanol, 1-propanol and Toluene)

  • 황인찬;김선우;인세진
    • 한국화재소방학회논문지
    • /
    • 제32권1호
    • /
    • pp.1-6
    • /
    • 2018
  • 인화점은 산업현장에서 액체의 화재 및 폭발 위험을 결정하는데 사용되는 가장 중요한 변수 중 하나로써 가연성 물질의 화재 위험성을 나타내는 지표이며 안정성 평가에 많이 사용되고 있다. 따라서 본 연구는 다양한 산업에서 용매로 사용되는 이성분계 혼합물 중 {methanol+toluene}, {ethanol+toluene} 그리고 {1-propanol+toluene}에 대한 인화점을 SETA 밀폐식 인화점 측정기를 이용하여 측정하였다. 각 이성분계 혼합물에 대한 인화점을 예측하기 위해 Raoult's의 법칙, Wilson, NRTL 및 UNIQUAC 파라미터를 이용하였고 실험 결과와 비교하였다. Raoult's의 법칙을 제외한 비교 결과, 모든 예측값과 실험값은 유사한 값을 보였고 편차가 1.69 K이내의 결과를 보였다.

밀폐계 측정장치를 이용한 물-노말프로판올 계의 인화점 (Flash Points of Water+n-Propanol System Using Closed-Cup Measurement Apparatus)

  • 하동명;최용찬;이성진
    • 한국안전학회지
    • /
    • 제17권4호
    • /
    • pp.140-145
    • /
    • 2002
  • The Flash Point is one of the most important combustible properties used to determine the potential for fire and explosion hazards of chemical materials. An accurate knowledge of the flash point is important in developing appropriate preventive and control measures in industrial fire protection. The lower flash points for the Water + n-Propanol systems were measured by using Pensky-Martens closed cup tester. The experimental data were compared with the values calculated by the laws of Raoult and van laar equation. The calculated values based on the van Laar equation were found to be better than those based on the Raoult's law.

Methanol, Ethanol, 2-Propanol 그리고 1-Butanol 이성분 혼합계에 대한 101.3 kPa에서의 인화점 측정 및 예측 (The Measurement and Prediction of Flash Point for Binary Mixtures of Methanol, Ethanol, 2-Propanol and 1-Butanol at 101.3 kPa)

  • 오인석;인세진
    • 한국화재소방학회논문지
    • /
    • 제29권5호
    • /
    • pp.1-6
    • /
    • 2015
  • 인화점은 화재 및 액체의 폭발 위험의 가능성을 결정하는 데 사용되는 가장 중요한 물리적 특성이고, 산업공정에서 안정성 평가시 중요한 연소특성 가운데 하나이다. 따라서 본 연구는 4류 위험물 중 알코올계 혼합물인 {methanol + 1-butanol}, {ethanol + 1-butanol} 그리고 {2-propanol + 1-butanol} 이성분계 101.3 kPa에서 최소인화점을 SETA closed cup flash point tester를 이용하여 측정하였다. 각 이성분계에 대하여 Wilson, NRTL 및 UNIQUAC 파라미터를 이용하여 혼합물에 대한 인화점 예측하고 실험 결과와 비교하였다. 비교결과 모든 예측값과 실험값은 유사한 값을 보였고 편차가 1.14 K 이내의 결과를 보였다.

Setaflash 장치를 이용한 산류와 케톤류의 폭발상한계 예측 (Prediction of Upper Explosion Limits (UEL) of Acids and Ketones by Using Setaflash Tester)

  • 하동명
    • 한국화재소방학회논문지
    • /
    • 제25권2호
    • /
    • pp.114-119
    • /
    • 2011
  • 폭발한계와 인화점은 가연성물질의 화재 및 폭발의 위험성을 결정하는데 중요한 연소특성치이다. 본 연구에서는 산류와 케톤류의 폭발상한계를 예측하기 위해서, 평형상태에서 인화점을 측정하는 Setaflash 밀폐식 장치(ASTM D3278)를 사용하여 이들의 상부인화점을 측정하였다. 측정된 상부인화점을 이용하여 Antoine 식에 의한 계산된 폭발상한계는 기존의 문헌값들보다 약간 낮게 나타났다. 본 연구에서 제시한 실험 및 예측 방법을 이용하여 다른 가연성물질의 폭발상한계 예측이 가능해 졌다.

이소프로필 알코올의 화재 및 폭발 특성치의 측정 및 고찰 (The Measurement and Investigation of Fire and Explosion Characteristics of Isopropyl Alcohol)

  • 하동명
    • 한국가스학회지
    • /
    • 제16권3호
    • /
    • pp.8-15
    • /
    • 2012
  • 이소프로필 알코올의 안전한 취급을 위해 $25^{\circ}C$에서 폭발한계를 고찰하였고, 실험장치를 이용하여 하부인화점, 상부인화점, 연소점 그리고 발화지연시간에 의한 발화온도를 측정하였다. 그 결과, 공정의 안전을 위한 이소프로필 알코올의 폭발 하한계는 2.0 vol%이고, 상한계는 12.0 vol%로 문헌을 통해 판단되었다. 하부인화점은 밀폐계에서 $12{\sim}14^{\circ}C$와 개방식에서 $18{\sim}19^{\circ}C$이었고, 상부인화점은 $38^{\circ}C$로 측정되었다. ASTM E659 장치를 사용하여 측정된 최소자연발화온도는 $463^{\circ}C$이었다.

2-프로판올과 톨루엔 혼합물질의 인화점 측정에 관한 연구 (Study on the Flash Point Determination of 2-Propanol-Toluene Mixtures)

  • 목연수;최재욱;김영일;최일곤;하동명
    • 한국안전학회지
    • /
    • 제12권3호
    • /
    • pp.114-119
    • /
    • 1997
  • The lower flash points and upper flash points of 2-propanol and toluene mixtures were determined by air-blowing method instead of Tag-closed flash point tester. The relations between the flash points and the composition of the mixtures are as follows, $T_{F.L}=4.3182+6.0909X_1$ $T_{F.U}=39.3636-2.9091X_1$ As results, the experimental data and the estimated values from the relations are considerably agreed, and we could plotted the relative diagram between flash points and the explosive range.

  • PDF

클리브랜드 개방식 장치를 이용한 2성분계의 인화점 (Flash Points of the Binary Solutions Using Cleveland Open Cup Tester)

  • 하동명;이성진
    • 한국화재소방학회논문지
    • /
    • 제25권1호
    • /
    • pp.57-62
    • /
    • 2011
  • 인화점은 공정안전을 평가할 때 산업공정에서 가연성 액체의 중요한 연소 특성 가운데 하나이다. 본 연구에서는 클리브랜드 개방식 장치를 사용하여 n-propanol + formic acid계와 acetic acid + propionic acid계의 인화점을 측정하였다. 실험값은 Raoult의 법칙과 최적화 기법에 의해 추산된 값과 비교하였다. 그 결과, 최적화 기법에 의한 추산값이 Raoult의 법칙에 의한 추산값 보다 실험값에 더욱 근접하였다.