• 제목/요약/키워드: Flash Point

검색결과 306건 처리시간 0.037초

3-헥사논의 화재 및 폭발 특성치의 측정 및 예측 (Measurement and Prediction of Fire and Explosion Properties of 3-Hexanone)

  • 하동명
    • 한국가스학회지
    • /
    • 제17권6호
    • /
    • pp.33-38
    • /
    • 2013
  • 3-헥사논의 안전한 취급을 위해, 폭발한계는 문헌을 통해 고찰하였고, 인화점과 발화지연시간에 의한 발화온도를 측정하였다. 그 결과, 밀페식 장치에 의한 3-헥사논(에틸프로필케톤)의 하부인화점은 $18^{\circ}C$로 측정되었으며, 개방식에서는 $27^{\circ}C{\sim}32^{\circ}C$로 측정되었다. ASTM E659 장치를 사용하여 자연발화온도와 발화지연시간을 측정하였고, 3-헥사논의 최소자연발화온도는 $425^{\circ}C$로 측정되었다. 측정된 인화점에 의한 폭발하한계는 1.21 Vol%로 계산되었다.

크실렌 이성질체의 인화점과 최소자연발화온도의 측정 (Measurement of Flash Points and Autoignition Temperatures for Xylene Isomers)

  • 하동명;이성진
    • 한국가스학회지
    • /
    • 제13권4호
    • /
    • pp.40-45
    • /
    • 2009
  • MSDS 자료의 적정성을 고찰하기 위해 크실렌 이성질체에 대해 Pensky-Martens 밀폐식(ASTM D93), Setaflash 밀폐식(ASTM D3278), Tag 개방식(ASTM D1310), Cleveland 개방식(ASTM D92) 장치 등을 이용하여 인화점을 측정하였으며, 또한 최소자연발화온도는 ASTM E659-78장치를 사용하여 측정하고, 문헌값들과 한국산업안전보건공단의 MSDS 자료와 비교하였다. 그 결과, 측정된 인화점과 최소자연발화온도는 이들과 차이를 나타내어 안전의 목적을 위해 연소특성치 고찰이 필요함을 알 수 있었다.

  • PDF

아니솔의 연소특성치의 측정에 의한 MSDS의 적정성 (Appropriateness of MSDS by Means of the Measurement of Combustible Properties of Anisole)

  • 하동명
    • 한국화재소방학회논문지
    • /
    • 제29권2호
    • /
    • pp.20-24
    • /
    • 2015
  • 아니솔의 안전한 취급을 위해, 폭발한계는 문헌을 통해 고찰하였고, 인화점과 발화지연시간에 의한 발화온도를 측정하였다. 그 결과, 밀폐식 장치에 의한 아니솔의 하부인화점은 $39^{\circ}C$$42^{\circ}C$로 측정되었으며, 개방식에서는 $50^{\circ}C$$54^{\circ}C$로 측정되었다. ASTM E659 장치를 사용하여 자연발화온도와 발화지연시간을 측정하였고, 아니솔의 최소자연발화온도는 $390^{\circ}C$로 측정되었다. 측정된 하부인화점에 의한 폭발하한계는 1.07 Vol%로 계산되었다.

노말도데칸의 인화점과 최소발화온도 측정에 의한 연소위험성 고찰 (The Investigation of Combustible Hazard by Measurement of Flash Point and Autoignition Temperature of n-Dodecane)

  • 하동명
    • 한국화재소방학회논문지
    • /
    • 제25권2호
    • /
    • pp.120-125
    • /
    • 2011
  • 노말도데칸의 안전한 취급을 위해서 25에서 폭발한계를 고찰하였고, 하부인화점과 발화지연시간에 의한 발화온도를 측정하였다. 공정의 안전을 위해서 노말도데칸의 폭발하한계는 0.60Vol.%, 상한계는 4.7Vol.%를 추천하였고, 하부인화점은 밀폐계에서 $77^{\circ}C$$80^{\circ}C$와 개방식에서 $84{\sim}87^{\circ}C$로 측정되었다. ASTM E659-78 장치를 사용하여 자연발화온도와 발화지연시간을 측정하였고, 최소자연발화온도는 $222^{\circ}C$ 측정되었다.

노말에틸아닐린의 화재 및 폭발 특성치의 측정 및 예측 (Measurement and Prediction of Fire and Explosion Properties of n-Ethylanilne)

  • 하동명
    • Korean Chemical Engineering Research
    • /
    • 제56권4호
    • /
    • pp.474-478
    • /
    • 2018
  • 공정안전을 위해서는 산업현장에서 취급하는 가연성물질의 화재 및 폭발 특성치가 있어야 한다. 사업장에서 사고를 예방하기 위한 연소특성치로 인화점, 연소점, 전폭발한계, 최소자연발화온도 등을 들 수 있다. 그러나 물질보건안전자료(MSDS)에서 제시하고 있는 특성치는 문헌들에 따라 달리 제시되고 있는데, 가연성물질을 안전하게 처리, 수송, 취급하기 위해서는 정확한 연소특성치가 필요하다. 화학산업에서 중간제품, 고무약품 등의 원료로 다양하게 사용되고 있는 노말에틸아닐린을 선정하였다. 그리고 노말에틸아닐린 안전한 취급을 위해서 인화점, 연소점 그리고 최소자연발화온도를 측정하였다. 노말에틸아닐린의 폭발하한계는 실험에서 얻어진 하부인화점을 이용하여 계산하였다. 노말에틸아닐린의 Setaflash 밀폐식은 $77^{\circ}C$, Pensky-Martens 밀폐식에서는 $82^{\circ}C$ 그리고 Tag 개방식에서는 $85^{\circ}C$, Cleveland 개방식에서는 $92^{\circ}C$로 측정되었다. ASTM E659 장치에 의한 측정된 노말에틸아닐린의 최소자연발화온도는 $396^{\circ}C$로 측정되었다. Setaflash 밀폐식에 의해 측정된 노말에틸아닐린의 하부인화점 $77^{\circ}C$에 의한 폭발하한계는 1.02 vol%로 계산되었다. 본 연구에서는 밀폐식에 의해 측정된 노말에틸아닐린의 하부인화점을 이용하여 폭발하한계의 예측이 가능하였다. 본 연구에서 제시된 노말에틸아닐린의 발화온도와 발화지연시간의 관계식은 노말에틸아닐린의 다른 발화온도에서도 발화지연시간의 예측이 가능해졌다.

2차전지 용액인 DEC(Diethyl Carbonate) + DMMP(Dimethyl Methylphosphonate)계의 연소특성치 측정 및 예측 (Measurement and Prediction of Combustion Characteristics of DEC(Diethyl Carbonate) + DMMP(Dimethyl Methylphosphonate) for Secondary Battery Solutions)

  • 장유선;장유리;최재준;전덕재;김용구;하동명
    • 한국안전학회지
    • /
    • 제38권5호
    • /
    • pp.8-14
    • /
    • 2023
  • Lithium ions can induce the thermal runaway phenomenon and lead to reignition due to electrical, mechanical, and environmental factors such as high temperature, smoke generation, explosions, or flames, which is extremely likely to create safety concerns. Therefore, one of the ways to improve the flame retardancy of the electrolyte is to use a flame-retardant additive. Comparing the associated characteristic value of existing substances with the required experimental value, it was found that these values were either considerably different or were not documented. It is vital to know a substance's combustion characteristic values, flash point, explosion limit, and autoignition temperature (AIT) as well as its combustion characteristics before using it. In this research, the flash point and AIT of materials were measured by mixing a highly volatile and flammable substance, diethyl carbonate (DEC), with flame-retardant dimethyl methylphosphonate (DMMP). The flash point of DEC, which is a pure substance, was 29℃, and that for DMMP was 65℃. Further, the lower explosion limit calculated using the measured flash point of DEC was 1.79 Vol.%, while that for DMMP was 0.79 Vol.%. The AIT was 410℃ and 390℃ for DEC and DMMP, respectively. In particular, since the AIT of DMMP has not been discussed in any previous study, it is necessary to ensure safety through experimental values. In this study, the experimental and regression analysis revealed that the average absolute deviation (ADD) for the flash point of the DEC+DMMP DEC+DMMP system is 0.58 sec and that the flash point tends to increase according to changes in the composition employed. It also revealed that the AAD for the AIT of the mixture was 3.17 sec and that the AIT tended to decrease and then increase based on changes in the composition.

이소부틸알코올(IBA)의 연소특성치 측정에 의한 MSDS의 적정성 연구 (The Study on the Compatibility of MSDS by Means of Measurement of Combustible Properties for Isobutylalcohol(IBA))

  • 하동명
    • 한국가스학회지
    • /
    • 제18권3호
    • /
    • pp.75-81
    • /
    • 2014
  • 이소부틸알코올의 안전한 취급을 위해, 폭발한계는 문헌을 통해 고찰하였으며, 인화점과 발화지연시간에 의한 자연발화온도는 장치를 이용하여 측정하였다. 공정에서는 이소부틸알코올의 폭발하한계는 1.7 Vol.% 그리고 상한계는 10.9 Vol.%가 사용되고 있다. 인화점의 경우 밀폐식 장치인 Setaflash와 Penski-Martens에 의한 하부인화점은 각 각 $25^{\circ}C$$30^{\circ}C$로 측정되었으며, 개방식인 Tag와 Cleveland 에서는 각 각 $36^{\circ}C$$39^{\circ}C$로 측정되었다. ASTM E659 장치를 사용하여 자연발화온도와 발화지연시간을 측정하였고, 이소부틸알코올의 최소자연발화온도는 $400^{\circ}C$로 측정되었다.

개방식 장치를 이용한 water+2-propanol계의 인화점 측정 및 예측 (The Measurement and Prediction of the Flash Points for the Water+2-Propanol System Using Open-Cup Apparatus)

  • 하동명;이성진
    • 한국화재소방학회논문지
    • /
    • 제21권2호
    • /
    • pp.48-53
    • /
    • 2007
  • 혼합물의 인화점에 대한 지식은 산업 현장에서 화재화재 예방 및 방호를 위해서 매우 중요하다. 본 연구에서는 water+2-propanol 계의 인화점을 Tag 개방식 장치(ASTM D1310-86)를 이용하여 측정하였다. 실험값은 Raoult의 법칙, Van Laar 모델식과 NRTL 모델식에 의해 계산된 값들과 비교되었다. 그 결과, Van Laar 모델식과 NRTL(non random two liquids) 모델식에 의한 예측값이 Rauolt의 법칙에 의한 예측값 보다 실험값에 더욱 근접하였다. 이는 water+2-propanol 계와 같은 비이상용액의 활동도 계수값을, Van Laar 및 NRTL 모델식이 Raoult의 법칙보다 정확하게 계산하기 때문이다. 또한, Van Laar 모델식의 실험값에 대한 모사성이 NRTL 모델식의 그것 보다 우수하였다.

이소프로필 알코올의 화재 및 폭발 특성치의 측정 및 고찰 (The Measurement and Investigation of Fire and Explosion Characteristics of Isopropyl Alcohol)

  • 하동명
    • 한국가스학회지
    • /
    • 제16권3호
    • /
    • pp.8-15
    • /
    • 2012
  • 이소프로필 알코올의 안전한 취급을 위해 $25^{\circ}C$에서 폭발한계를 고찰하였고, 실험장치를 이용하여 하부인화점, 상부인화점, 연소점 그리고 발화지연시간에 의한 발화온도를 측정하였다. 그 결과, 공정의 안전을 위한 이소프로필 알코올의 폭발 하한계는 2.0 vol%이고, 상한계는 12.0 vol%로 문헌을 통해 판단되었다. 하부인화점은 밀폐계에서 $12{\sim}14^{\circ}C$와 개방식에서 $18{\sim}19^{\circ}C$이었고, 상부인화점은 $38^{\circ}C$로 측정되었다. ASTM E659 장치를 사용하여 측정된 최소자연발화온도는 $463^{\circ}C$이었다.

tert-Amylalcohol(TAA)의 물질안전보건자료(MSDS) 연소특성치의 신뢰도 (Reliability of Combustion Properties of MSDS(Material Safety Data Sheet) of tert-Amylalcohol(TAA))

  • 하동명
    • 한국가스학회지
    • /
    • 제23권6호
    • /
    • pp.17-24
    • /
    • 2019
  • 산업현장에서 사용되고 있는 인화성물질의 연소특성치로는 하부/상부인화점. 폭발하한계/상한계, 최소자연발화온도(AIT), 연소점, 최소산소농도(MOC) 등이 있다. 공정 및 근로자 안전을 위해서는 이들 특성치의 정확한 평가가 이루어져야 한다. 본 연구에서는 에폭시수지와 폴리우레탄의 용매, 올레핀의 산화제, 연료용 기름과 바이오물질의 주원료 등으로 다양하게 사용되고 있는 tert-Amylalcohol(TAA)를 선정하였다. 그 이유는 다른 가연성물질에 비해 연소특성치의 신뢰성에 비교 고찰하였다. TAA의 인화점은 밀폐식 Setaflash, Pensky-Martens와 개방식 Tag, Cleveland 장치로 측정하였고, AIT는 ASTM 659E를 사용하였다. 그리고 TAA의 폭발하한계/상한계는 측정된 하부/상부인화점을 이용하여 예측하였다. Setaflash, Pensky-Martens에 의한 인화점은 19 ℃와 21 ℃, Tag와 Cleveland는 각각 28 ℃와 34 ℃, AIT는 437 ℃로 측정되었다. Setaflash에서 측정된 인화점에 의한 폭발하한계/상한계는 1.1 vol%와 11.95 vol%로 계산되었다.