• 제목/요약/키워드: Flammable liquid

검색결과 102건 처리시간 0.03초

파라크실렌과 에폭시수지 혼합물의 인화점에 관한 연구 (Flash Point of p-xylene and Epoxy Resins Mixtures)

  • 윤희승;강민호;하동명;정국삼
    • 한국안전학회지
    • /
    • 제15권3호
    • /
    • pp.78-82
    • /
    • 2000
  • The flash point is an important property and hazardous index of a flammable liquid. The flash points are used by virtually all the environmental, health, and safety organizations in both government and industry to classify flammable liquids for safety and transportation regulations. The basics of all flash points behavior are concerned with the vapor pressure and explosive limits. The flash points of pure components and the mixture of solvents can be calculated with the use of the laws of Raoult, Dalton and Le Chatelier. In this paper, experimentally determined lower flash points of a p-xylene and epoxy resin system were compared with the calculated values by using Raoults law. Calculated lower flash points were in reasonable agreement with the observed values.

  • PDF

노말알칸류와 방향족탄화수소류의 상부인화점 측정에 의한 폭발상한계의 예측 (Prediction of Upper Explosion Limits(UEL) by Measurement of Upper Flash Points for n-Alkanes and Aromatic Compounds)

  • 하동명
    • 한국안전학회지
    • /
    • 제26권4호
    • /
    • pp.59-64
    • /
    • 2011
  • Explosion limit and flash point are the major combustion properties used to determine the fire and explosion hazards of the flammable substances. In this study, in order to predict upper explosion limits(UELs), the upper flash point of n-alkanes and aromatic compounds were measured under the VLE(vapor-liquid equilibrium) state by using Setaflash closed cup tester(ASTM D3278). The UELs calculated by Antoine equation and chemical stoichiometric coefficient tusing the experimental upper flash point were compared with the several reported UELs. From the given results, using the proposed experimental and predicted method, it is possible to research the upper explosion limits of the other flammable substances.

Cycling Performance of Li4Ti5O12 Electrodes in Ionic Liquid-Based Gel Polymer Electrolytes

  • Kim, Jin-Hee;Kang, Yong-Ku;Kim, Dong-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권2호
    • /
    • pp.608-612
    • /
    • 2012
  • We investigated the cycling behavior of $Li_4Ti_5O_{12}$ electrode in a cross-linked gel polymer electrolyte based on non-flammable ionic liquid consisting of 1-butyl-1-methylpyrrolidinium bis(trifluoromethanesulfonyl) imide and vinylene carbonate. The $Li_4Ti_5O_{12}$ electrodes in ionic liquid-based gel polymer electrolytes exhibited reversible cycling behavior with good capacity retention. Cycling data and electrochemical impedance spectroscopy analyses revealed that the optimum content of the cross-linking agent necessary to ensure both acceptable initial discharge capacity and good capacity retention was about 8 wt %.

인화성 혼합유의 구획 화재에 의한 화염의 전파 속도 및 특성 해석 (Propagation Speed and Characteristic Analysis of Flame in Compartment Fires of Flammable Liquids)

  • 조희수;이재오;최충석
    • 한국화재소방학회논문지
    • /
    • 제29권3호
    • /
    • pp.31-36
    • /
    • 2015
  • 본 연구는 동일 비율로 휘발유와 혼합된 인화성 액체 200 ml를 축소 모의된 구획 공간에 채우고 착화시켰을 때의 특성을 해석하였다. 구획된 공간의 한 변은 2,000 mm이며, 연소가 진행된 장치의 길이는 1,000 mm이다. 휘발유와 알코올을 혼합한 물질의 화염 전파 속도가 0.7 s로 가장 빠르고, 가장 늦은 물질은 휘발유와 경유를 혼합한 물질로 1.2 s이다. 화염이 최성기에 가장 빨리 도달한 물질은 휘발유와 아세톤을 혼합한 것으로 25.5 s가 소요되었다. 또한 휘발유와 경유를 혼합한 물질은 163.7 s로 가장 늦었다. 연소의 지속 시간은 휘발유와 경유를 혼합한 물질이 332.7 s로 가장 길었으며, 가장 짧은 것은 휘발유와 시너를 혼합한 물질로 121.5 s이다. 따라서 화재 현장을 조사하는 화재조사관은 최초 목격자의 진술은 물론 화염의 특성을 종합적으로 분석할 필요가 있다.

Method applied to evaluate heat leakage of cryogenic vessel for liquid hydrogen

  • Li, Zhengqing;Yang, Shengsheng;Wang, Xiaojun;Yuan, Yafei
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권1호
    • /
    • pp.7-11
    • /
    • 2021
  • Cryogenic vessels are special equipment that requires periodic evaluation of their thermal insulation performance. At the current standard, the test is considered as the loss product or heat leakage of cryogenic vessel, which takes over 72 h to evaluate; consequently, a large amount of working medium is discharged to the environment in the process. However, hydrogen is flammable and explosive, and the discharged gas may be dangerous. If liquid hydrogen is replaced with liquid nitrogen before testing, the operation then becomes complicated, and the loss product or heat leakage cannot respond to the thermal insulation performance of cryogenic vessels for liquid hydrogen. Therefore, a novel method is proposed to evaluate the heat leakage of cryogenic vessels for liquid hydrogen in self-pressurization. In contrast to the current testing methods, the method proposed in this study does not require discharge or exchange of working medium in all test processes. The proposed method is based on one-dimensional heat transfer analysis of cryogenic vessels, which is verified by experiment. When this method is used to predict the heat leakage, the comparison with the experimental data of the standard method shows that the maximum error of heat leakage is less than 5.0%.

톨루엔 누출 시 대기확산 및 화재가능성에 관한 수치해석 연구 (Numerical Study on Atmospheric Dispersion and Fire Possibility in Toluene Leakage)

  • 고재선;김주석
    • 한국화재소방학회논문지
    • /
    • 제31권3호
    • /
    • pp.1-10
    • /
    • 2017
  • 본 연구는 안전시설이 없는 위험물저장시설에서 위험물을 취급시 발생할 수 있는 사고에 대한 위험성을 알아보고자 했다. 불법위험물 운반용기는 화재가 발생할 경우 연소속도가 매우 빨라 폭발로 이어져 피해가 크며 진화하기도 어렵다. 또한 인화성 액체위험물에서 발생하는 사고는 누출로 인해 공간에서 발생하는 사고가 대부분을 차지하고 있다. 따라서 이러한 사고에 대한 영향을 주는 변수를 도출했고, 이 변수들이 미치는 영향을 알아보고자 했다. 수치해석 및 전산유체역학프로그램을 이용해서 해석해 본 결과 다음과 같은 최종결과를 얻을 수 있었다. 먼저 특정 공간에 인화성액체가 누출되었을 때 특정농도(연소하한계)가 될 때까지의 온도와 상대습도의 영향을 받고, 온도의 경우 인화점 이상에서는 인화점 이하에서보다 도달시간이 짧아지는 것을 알 수 있었다. 또한 누출로 인한 저장탱크의 Pool Fire사고에 미치는 변수의 영향의 정도는 다소 차이가 있으나 주로 가장 큰 영향을 미치는 변수는 풍속으로 나타났다. 따라서 향후 본 연구를 통해서 유사한 수치해석적인 연구의 기초자료로 활용될 수 있을 것이고. 다양한 연구조건에서 위험물질이 누출되는 사고에 대해서 유용한 수치해석적인 정보를 제공할 수 있을 것으로 기대한다.

가연성 액체 혼합물의 인화 위험성에 관한 연구 (A Study on Flammability Risk of Flammable Liquid Mixture)

  • 김주석;고재선
    • 한국재난정보학회 논문집
    • /
    • 제16권4호
    • /
    • pp.701-711
    • /
    • 2020
  • 연구목적: 본 연구에서는 두 물질의 혼합물(가연물+가연물)에서의 인화 위험성의 증가 또는 감소를 실험적으로 확인하고, 혼합물의 위험성을 제시하는 목적이 있기에 액체 혼합물의 인화 위험성을 실험적으로 확인하였다. 연구방법:인화점 실험방법 및 결과처리는 원유 및 석유 제품 인화점 시험 방법으로 사용되고 있는 테그밀폐식 시험방법인 KS M 2010-2008을 기준으로 실험하였다. 본 실험에 사용한 장비의 제조사는 일본의 TANAKA사에서 생산한 장비로 KS M 2010의 시험규격을 만족하는 시험장비로 인화점을 측정하였고, 점화원으로는 LP가스를, 냉각수로는 물을 사용하였다. 또한 인화점 측정시 냉각수의 온도는 약 2℃의 냉각수를 사용하여 실험을 진행하였다. 연구결과:실험결과로는 먼저 가연성+가연성 혼합물의 경우 두 물질의 인화점 차이가 크지 않으면 인화점의 변화가 거의 없었고, 두 물질의 인화점 차이가 낮으면 인화점이 높은 물질의 증가에 따라 인화점이 증가하는 경향을 보였으나, 톨루엔과 메탄올의 경우, 혼합물에서 인화점이 낮은 물질보다 더 낮은 인화점을 보였다. 또한 도료용 희석제의 경우, 혼합물로 이루어져서 그 물질의 인화점을 예상하기가 쉽지 않았지만 실험적으로 측정해 본 결과 -24℃~7℃사이로 측정되었다. 결론: 본 연구에서의 결과는 기존의 위험물안전관리법에서의 위험물 판정 기준에 대한 세부 내용의 실효성 확보 및 위험물 판정의 신뢰성 및 재현성 확보를 목적으로 인화성 혼합물에 대한 실험적 연구를 통해서 혼합물에 대한 위험성 판단 기준을 제시하였고, 향후 소방현장에서 단속되는 인화성 액체 대한 실험적 판정 기준에 대한 참고적인 자료를 제공할 수 있을 것이다. 또한 본 연구로 시험방법별 차이 실험에 대한 노하우를 축적한다면 위험물의 위험성 평가 연구에 있어 기초 자료이자 위험물 판정 관한 연구의 기반으로 활용될 수 있기를 기대한다.

Cleveland 개방식 장치를 이용한 Acetic acid+Formic acid 계의 인화점 측정과 예측 (Measurement and Prediction of Flash Points of Acetic Acid-Formic Acid System using Cleveland Open Cup Apparatus)

  • 하동명;이성진
    • 한국가스학회지
    • /
    • 제17권6호
    • /
    • pp.67-72
    • /
    • 2013
  • 인화점은 공기와 섞인 가연성 증기의 농도가 발화하기에 충분할 때의 최저 온도로, 가연성 액체 용액의 화재 및 폭발 위험성을 분석하는데 사용되는 주된 물리적 특성치이다. 단일 성분의 인화점 정보는 여러 문헌에서 얻을 수 있으나, 가연성 이성분계 혼합물의 인화점은 충분히 제공되어 있지 않다. 본 연구의 목적은 이성분계 가연성 액체 혼합물인 아세트산-포름산계의 인화점을 측정하고, 산출하는 것이다. 인화점 측정은 Cleveland 개방식 장치를 사용하였고, 실험값은 van Laar 식과 Wilson 식을 활용한 최적화 기법에 의해 산출된 값과 비교하였다. 그리고 라울의 법칙에 의해 산출된 값과 비교되었다. 그 결과, 최적화 기법에 의한 산출값이 Rauolt의 법칙에 의한 산출값보다 실험값에 보다 근접하였다.

가연성 이성분계의 최소자연발화온도 거동(MAITB) (Minimum Autoignition Temperature Behavior(MAITB) of the Flammable Binary Systems)

  • 하동명;이성진
    • 한국안전학회지
    • /
    • 제23권6호
    • /
    • pp.70-75
    • /
    • 2008
  • The values of the AIT(Autoignition temperature) for fire and explosion protection are normally the lowest reported. The minimum autoignition temperature behavior(MAITB) of flammable liquid mixtures is exhibited when the AIT of mixture is below the AIT of the individual components. The MAITB is an interesting experimental features, which can be significant from the perspective of industrial safety. In this study, the AITs of m-xylene+n-butyric acid and ethylbenzene+n-butanol systems were measured using ASTM E659-78 apparatus. The AITs of m-xylene, n-butyric acid, ethylbenzene and n-butanol which constituted two binary systems were $587^{\circ}C$, $510^{\circ}C$, $475^{\circ}C$ and $340^{\circ}C$ respectively. The m-xylene+n-butyric acid system is exhibited MAITB at 0.3 mole fraction of m-xylene, and its minimum autoignition temperature was $460^{\circ}C$.