• 제목/요약/키워드: Flammable

검색결과 510건 처리시간 0.023초

Cycling Performance of Li4Ti5O12 Electrodes in Ionic Liquid-Based Gel Polymer Electrolytes

  • Kim, Jin-Hee;Kang, Yong-Ku;Kim, Dong-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권2호
    • /
    • pp.608-612
    • /
    • 2012
  • We investigated the cycling behavior of $Li_4Ti_5O_{12}$ electrode in a cross-linked gel polymer electrolyte based on non-flammable ionic liquid consisting of 1-butyl-1-methylpyrrolidinium bis(trifluoromethanesulfonyl) imide and vinylene carbonate. The $Li_4Ti_5O_{12}$ electrodes in ionic liquid-based gel polymer electrolytes exhibited reversible cycling behavior with good capacity retention. Cycling data and electrochemical impedance spectroscopy analyses revealed that the optimum content of the cross-linking agent necessary to ensure both acceptable initial discharge capacity and good capacity retention was about 8 wt %.

가연성 단열재를 사용한 외단열 도시형 생활주택의 방화를 위한 보강재 검토 (Examined of reinforcement for the fire protection of the outside insulation Urbantype Housing with flammable insulation material)

  • 이광희;정의인;김봉주
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.28-29
    • /
    • 2015
  • Due to the big fire in Uijeongbu, the status of construction, fireproof materials and structural method were examined to prevent fire propagation through outside insulation parts of urban living homes. Through research and experiments, the following results were obtained. It was confirmed that outside heat-insulation wall method was used in a large number of urban living homes which were made of materials and structures spreading fire easily.Through experiments, it was revealed that lightweight plate material, as a fireproof material, can save the cost as well as the period of construction and obtain more than 30 minutes of evacuation time which is twice the maximum evacuation time.

  • PDF

콘칼로리미터를 이용한 건축용 막재의 내화 특성 연구 (A Fire Resistance Property Study of Architectural Fabric using Cone Calorimeter)

  • 김지현;신현욱;송훈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.158-159
    • /
    • 2015
  • Architectural fabrics are now used in membrane structure with the merits of free shape, lightness and opened up new possibility for the design of new building structures. Recently PVC, PVF, PVDF, PTFE coated fabric for using the membrane structures. However, clear standards for the design and construction is not exist because of the lack of Architectural fabric research. In this paper, Flammable properties of PVDF, PTFE coated fabrics are obtained through the Flammability test using the Cone Calorimeter. Based on these results, identify the fire resistance property of the Architectural fabric.

  • PDF

톨루엔과 2-부탄올 계의 최소자연발화온도의 측정 및 예측 (Prediction and Measurement of Autoignition Temperature of Toluene and 2-Butanol System)

  • 하동명
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.73-78
    • /
    • 2015
  • The autoignition temperatures(AIT) of solvent mixture is important index for the safe handling of flammable liquids which constitute the solvent mixtures. Therefore, the AITs of common pure chemical substances are widely reported, but very limited data are available for mixtures. This study, the toluene and 2-butnaol system which used mixture solution solvent was measured the AIT and ignition delay time by using ASTM E659 apparatus. The AITs of toluene and 2-butanol constituted binary system were $547^{\circ}C$ and $400^{\circ}C$, respectively. The experimental AIT of toluene and 2-butanol were a good agreement with the calculated AIT by the proposed equations with a few average absolute deviation(A.A.D.).

제조업체 방폭설비 적용에 관한 연구 (A Study on the Explosionproof devices Installation in the Manufacturing Process)

  • 송용식;이준석;정현규;조원철;이태식
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.565-570
    • /
    • 2007
  • The explosionproof apparatus is a devices that is enclosed in a case capable of withstanding an explosion of a specified gas or vapor that may occur within it and of preventing the ignition of a specified gas or vapor surrounding the enclosure by sparks, flashes, or explosion of the gas or vapor within, and that operates at such an external temperature that a surrounding flammable atmosphere will not be ignited thereby This kind of exeplosionfproof devices should be installed suitable for the characteristics of the space or process condition that should be protected to prevent explosion or fire. But, due to the lack of information and techniques on the explosionproof technology, some dangerous area is not properly protected from an explosion or it cost too much to implement the explosionproof devices. In this report, the basic guidelines and several case studies of explosionproof devices installation will be introduced to be of help to field safety engineer.

  • PDF

연소실 분위기 압력이 화염형상에 미치는 영향 (The Influence of Combustor Atmospheric Pressure on Flame Characteristics)

  • 김종률;최경민;김덕줄
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1134-1139
    • /
    • 2004
  • Recently, development of flame control scheme has been hot issues in the combustion engineering. It has been held that flame shape can be controllable by pressure inside combustor. The influence of combustor atmospheric pressure on flame shape was investigated in the present study. The flame shape, flammable limit, flame temperature and nitric oxide emission were measured as functions of combustor atmospheric pressure and equivalence ratio. The reaction region became longer and wider with decreasing combustor atmospheric pressure by direct photography, hence reduction of blow off limit. This tendency was also observed in the mean flame temperature distribution. Nitric oxide emission decreased with decreasing combustor atmospheric pressure. Low NOx combustion is ascribed to wide-spread reaction region in the low atmospheric pressure condition. These results demonstrate that flame shape and nitric oxide emission can be controllable with combustor atmospheric pressure.

  • PDF

가발에 사용되는 원사의 특성 연구 (A Study of Characteristics of Weft Used in Wig Manufacturing)

  • 임순녀
    • 한국염색가공학회지
    • /
    • 제24권3호
    • /
    • pp.204-212
    • /
    • 2012
  • This study was used a thermogravimetric analyzer to determine thermal characteristics, a hair analysis system to examine morphological changes of wefts-human hair, poly vinyl chloride(PVC) and polyethylene terephthalate (PET)-used in manufacturing wigs. According to a flammability test on human hair and synthetic wefts for wigs, the best results were observed in human hair. According to a thermal test, PET was the best in terms of thermal stability. Also good tensile strength was observed as well. In a scanning electron microscope observation, no human hair scale layer was found because of chemical treatment. In the PVC sample, homogeneous unevenness was observed. Due to a lack of human hair supply and increase in its price, recently, PET weft has emerged as a great substitution for human hair. Because it can be curled using an electric curling device and is more efficient than the conventional non-flammable material PVC in terms of thermal resistance, it will become the next-generation weft for wigs.

The Lower Flash Points of the n-Butanol+n-Decane System

  • Dong-Myeong Ha;Yong-Chan Choi;Sung-Jin Lee
    • 한국화재소방학회논문지
    • /
    • 제17권2호
    • /
    • pp.50-55
    • /
    • 2003
  • The lower flash points for the binary system, n-butanol+n-decane, were measured by Pensky-Martens closed cup tester. The experimental results showed the minimum in the flash point versus composition curve. The experimental data were compared with the values calculated by the reduced model under an ideal solution assumption and the flash point-prediction models based on the Van Laar and Wilson equations. The predictive curve based upon the reduced model deviated form the experimental data for this system. The experimental results were in good agreement with the predictive curves, which use the Van Laar and Wilson equations to estimate activity coefficients. However, the predictive curve of the flash point prediction model based on the Willson equation described the experimentally-derived data more effectively than that of the flash point prediction model based on the Van Laar equation.

퍼지논리를 적용한 전기적 접촉불량 및 아크 검출에 관한 연구 (A study on the detection of poor contact and arcing fault using a fuzzy logic)

  • 김현우;김인태
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2007년도 추계학술논문발표회 논문집
    • /
    • pp.205-210
    • /
    • 2007
  • This study on the prevention of electric fire. Generally the electric fire is caused by break or disconnection of the power line, short circuit and poor contact, arcing fault ect. In these causes, this paper is studied on the detection of poor contact and arcing fault. The arcing fault is caused by poor contact mainly. The arcing fault can occurs a electric fire by interaction of flammable gas and materials and it can be caused of tracking and carbonization. These phenomenons is also caused of electric fire. Therefore this paper is studied on the detection of arcing fault and poor contact.

  • PDF