• Title/Summary/Keyword: Flame Time

Search Result 712, Processing Time 0.022 seconds

Feasibility Study on the Fire Scenario Design of a Couch Burning through a Fire Spread Model (화염 전파모델을 이용한 소파화재 설계화원구성의 적용성 연구)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.37-42
    • /
    • 2016
  • The present study has been performed to examine the feasibility of a flame spread model on the design fire scenario for fire risk analysis. Thermo-Gravimetric analysis and sample burning test were conducted to obtain the material properties of a single couch covered with synthetic leather material and a series of FDS calculations applying with the measured material properties were performed for different grid sizes. The overall fire growth characteristics predicted by the fire model were quite different from the results of a real scale fire test and the initial peak value of the HRR and total released energy showed the results within a 30% discrepancy for the computational grids used in the present study. The current model has some limitations in predicting the fire growth characteristics, such as fire growth rate and the time to the maximum HRR. This study shows that the fire model may be applicable to creating the design fire scenario through continuous model improvement and detailed material properties.

Fire Test of Old Type Interiors of Subway Vehicle in ISO 9705 Room (ISO 9708 룸 설비를 이용한 구형 지하철 내장재 화재시험)

  • Lee, Duck-Hee;Park, Won-Hee;Jung, Woo-Sung;Hwang, Jung-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.5
    • /
    • pp.481-487
    • /
    • 2010
  • A room scale fire test was done for interior materials from a subway vehicle installed within an ISO 9705 fire test room. The interior materials are the old ones which were made before the new fire safety guideline of subway vehicles. The output of ignition burner was increased in controlled steps to CEN/TS 45545-1. The objectives of this interior fire test are to assess the fire performance in terms of ignition and flame spread on interior lining materials and to provide data on an enclosure fires involving subway vehicle interior materials that grow to flashover. Temperatures, heat flux and heat release rate variations verse time of the test are measured. Heat release rate is compared with that of calculated by modified flaming area based summation method. These test results will be used for verification of CFD fire simulation of full subway vehicle.

Epidemiologic Analysis of Burns in Military Hospital

  • Choi, Jangkyu;Park, Sejin;Kim, Hyun Chul
    • Journal of Trauma and Injury
    • /
    • v.30 no.4
    • /
    • pp.145-157
    • /
    • 2017
  • Purpose: We accessed epidemioloy of 908 acute burns (7 years) in the military, of injuries and propose proper educational programs to suit community. Methods: We surveyed burn demographics, circumstances of injuries, size, result of treatment. Results: The mean age was 20.6 years. The flame burns (FB) (325, 35.8%) were most common, followed scald (SB) (305, 33.6%), contact (CB) (219, 24.1%), electric (EB) (45, 5.0%) and chemical burns (ChB) (14, 1.5%). The more occurred during winter (29.7%). SB had mean 3.9% total body surface area (TBSA). The 251 (82.3%) had superficial burns by spillage of hot water/food on lower limbs (45.6%), feet (33.8%) in summer (34.8%), treated with simple dressing (92.8%). Morbidity rate was 5.6%; post traumatic stress disease (PTSD) (0.7%). FB had large wound (9.3% TBSA). The 209 (64.3%) had superficial burns by ignition to flammable oils (31.7%) and bomb powders (29.2%) on head/neck (60.3%), hands (58.6%) in summer (31.7%), autumn (30.2%). They underwent simple dressing (83.4%) and skin graft (16.0%). Morbidity rate was 18.8%; PTSD (10.5%), inhalation injuries (4.0%), corneal injury (3.7%), amputations (0.9%), and mortality rate (1.2%). CB had small (1.1% TBSA), deep burns (78.5%) by hotpack (80.4%) on lower limbs (80.4%). The more (59.8%) underwent skin graft. EB had 6.8% TBSA. The 29 (64.4%) had superficial burns by touching to high tension cable (71.1%) on hand (71.1%), upper limbs (24.4%) in autumn (46.8%). They underwent simple dressing (71.1%) and skin graft (24.4%). They showed high morbidity rate (40.0%); loss of consciousness (13.3%), nerve injuries (11.1%), neuropathy (8.9%), amputations (2.2%), and mortality rate (2.2%). Conclusions: The cook should wear apron over the boots during work. The lighter or smoking should be strictly prohibited during work with flammable liquids or bomb powders. Don't directly apply hotpack to skin for a long time. Use insulating glove during electric work. Keep to the basic can prevent severe injury and proper education is important.

The Consequence Analysis for Fire Accidents by the Continuous Release of Butane Vapor in the Debutanizing Process of Naphtha Cracking Plant (나프타분해플랜트의 부탄추출공정에서 부탄증기의 연속누출에 의한 화재사고의 영향평가)

  • 윤대건;이헌창;함병호;조지훈;김태옥
    • Fire Science and Engineering
    • /
    • v.12 no.2
    • /
    • pp.3-15
    • /
    • 1998
  • The consequence analysis for jet and flash fire accidents by the continuous release of butane vapor was performed and effects of process variables on consequences were analyzed in standard conditions. For the continuous release (87.8 kg/s) of butane vapor at 8m elevated height in the debutanizing process of the naphtha cracking plant operating at 877 kPa, 346.75 K, we found that for the jet fire accident, shape and size of the flame could be predicted and thermal radiation estimated by API model at 200m distance from release point was 1.5kW/$m^2$, and that for the flash fire accident, effect range was 11.2~120.2m. Also, simulation results showed that effects of operating pressures on consequences were larger than those of operating temperatures and results of accidents were increased with increasing operating pressures. At this time, effects of operating pressures on XUFL were smaller(about 1/10) than those on XLFL for the flash fire accident.

  • PDF

A Study on the Fire Resistance Performance of Wood Framed Lightweight Wall which Including a Middle Lintel (중인방을 포함한 목골조 경량벽체의 내화성능에 관한 연구)

  • Yeo, In-Hwan;Cho, Bum-Yean;Min, Byung-Yeol;Yoon, Myung-O
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.91-98
    • /
    • 2011
  • This study is about fire resistance performance of wood framed lightweight wall including a middle lintel as a traditional wall form in Korea. The target wall is non-loadbearing system which constructed with $38{\times}89$ mm ($2"{\times}4"$) wood frame and fireproof gypsum board covering, including a middle lintel made of $150{\times}150$ mm section glue-laminated timber. As a test results, all specimens have showed fire resistant performance over 90 minutes and tests were maintained until flame occuring on Specimen-l, 2, 3 at 91 min, 97 min and 98 min respectively. Fire resistance of the heat side gypsum board was 45 minutes and charring rate of middle lintel was equivalant with that of usual timber. The wood stud inside wall system showed relatively quick combution characteristic when exposed to high temperature with no temperature rising delaying time caused by moisture evaporation because of the dehydration preceded during the early period of fire side gypsum board resist to heat.

An Experimental Study on Performance and Emission Characteristics of Hydrogen Mixtures in a CNG Engine (CNG 기관의 수소혼합률 변화에 따른 성능 및 배출가스 특성에 관한 실험적 연구)

  • KIM, INGU;SON, JIHWAN;KIM, JOUNGHWA;KIM, SUNMOON;KIM, JEONGSOO;LEE, SEANGWOCK
    • Journal of Hydrogen and New Energy
    • /
    • v.27 no.4
    • /
    • pp.357-364
    • /
    • 2016
  • Recently, the world faces the environmental problem such as air pollution due to harmful gas discharged from car and abnormal climate due to the green-house gases increased by the discharge of $CO_2$. Compressed Natural Gas (CNG), one of alternative for this problem, is less harmful, compared to the existing fossil fuel, as gaseous fuel, and less carbon in fuel ingredients and carbon dioxide generation rate relatively favorable more than the existing fuel. However, CNG fuel has the weakness of slow flame propagation speed and difficult fast burn. On the other hand, hydrogen does not include carbon in fuel ingredients, and does not discharge harmful gas such as CO and HC. Moreover, it has strength of quick burning velocity and ignition is possible with small ignition energy source and it's has wide Lean Flammability Limit. If using this hydrogen with CNG fuel, the characteristics of output and discharge gas is improved by the mixer's burning velocity improved, and, at the same time, is possible to have stable lean combustion with the reduction of $CO_2$ expected. Therefore, this research tries to identify the characteristics of engine and emission gas when mixing CNG fuel and hydrogen in each portion and burning them in spark igniting engine, and grasp the combustion stability and emission gas characteristics according and use it as the basic data of hydrogen-CNG premixed engine.

A Study on the Fire Risk Comparison of Building Flooring Materials by External Heat Flux (건축용 바닥재의 외부복사열에 의한 화재위험성 비교 연구)

  • Park, Youngju;Kim, Youngtak
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.20-24
    • /
    • 2017
  • In this study, we have performed the Cone Calorimeter test in accordance with ISO 5660-1 to check the combustion characteristics of building flooring materials. The fire risk of these materials were evaluated by construction code, KFI criteria and standards of flame retardant performance. When samples exposed to external heat flux, all samples consumed a lot of Oxygen for a long time. So heat release from sample burning continued so long. And also all samples produced so much smoke. Even though a few samples were satisfied with only peak heat release rate criteria, all 8 samples were not satisfied with criteria of peak heat release rate and total heat released together. The results of 5 min total heat released were $15.9MJ/m^2{\sim}5.9MJ/m^2$. It menas the results are more than 2~6 times higher than the criteria. The results of 10 min total heat released were $30.1MJ/m^2{\sim}100.8MJ/m^2$. It means the results are more than 3~12 times higher than the criteria. 6 of 8 samples were not satisfied with Dm.corr.(corrected maximum smoke density) criteria. The building flooring materials which we used for this test ignited very fast and the burning continued so long. It means these samples are susceptible to fire.

Evaluation of Airborne Volatile Organic Compounds Concentrations During Nail Art Practicing for College Students (대학 네일아트 실습 중 발생하는 휘발성 유기화합물의 공기 중 농도 평가)

  • Park, Yunkyung;Choi, Inja;Choi, Hyeyoung;Ahn, Jaekyoung;Choi, Sangjun;Kim, Sujin;Kim, Hyunseo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.4
    • /
    • pp.452-463
    • /
    • 2019
  • Objectives: The purpose of this study is to evaluate airborne concentrations of volatile organic compounds(VOCs) during nail art practice by college students. Methods: Personal samples for students were measured using passive samplers(OVM 3500) during three kinds of practice, including polish nail, gel nail and acrylic French sculpture at two universities located in Gyeongsangbuk-do Province. We also monitored area concentrations using active samplers and real-time total VOC monitors(ppbRAE 3000). All samples were analyzed with a gas chromatography flame ionized detector. Statistical analysis for monitored data were conducted using a web-based Bayesian toolkit, EXPOSTATS(www.expostats.ca). Results: Twenty-four personal samples and ten area samples were collected and five chemicals(acetone, butyl acetate, ethyl acetate, ethyl methacrylate(EMA) and methyl methacrylate(MMA)) were detected. Acetone was detected in all personal samples and ranged from 2.58 ppm to 50.3 ppm. EMA was detected in all personal and area samples with a maximum concentration of 9.78 ppm during acrylic French sculpture. Personal exposure levels to acetone, butyl acetate and mixtures were significantly higher with high occupant density (p<0.05). Geometric mean (GM) concentrations of 3.61 ppm for EMA personal samples were significantly higher than that of area samples, 1.5 ppm (p<0.05). Since there was no local ventilation, total VOC concentration continued to increase as the practice progressed. Conclusions: In order to minimize VOCs exposure for trainees, it is necessary to introduce a local ventilation system and maintain adequate occupant density.

Technical Review and Analysis of Ramjet/Scramjet Technology I. Ramjet Engine (Liquid Ramjet, Ducted Rocket) (램제트/스크램제트의 기술동향과 소요기술 분석 I. 램제트 엔진(액체램제트, 덕티드로켓))

  • Sung Hong-Gye;Yoon Hyun-Gull
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.1
    • /
    • pp.72-86
    • /
    • 2006
  • A technical review of current ramjet propulsion is presented. In addition to summarize the current status of ramjet technology, new key techniques like Boosting technique easily adapting total impulse of booster, flame stabilization technique with minimized ramjet combuster length, variable nozzle-inner-surface technique realizing wide flight-envelop, and thermal protection technique for long operating time are identified. Actually various Ramjet propulsion technology has been matured and expanding to both military and combined cycle application. Yet many opportunities remain to be challenged by future generations of explorers to utilize s typical ramjet propulsion system for multi-purpose(multi-platform and multi-target) missiles, for example, American JSSCM and Russian Yakhont missiles, improving both reliability of techniques and downsizing development cost of new propulsion system.

Using Two-Dimensional Chemiluminescence Images to Study Inhomogeneity in Mixture Gas in the Combustion Chamber for HCCI Combustion (이차원발광화상계측에 의한 예혼합압축자기착화연소의 연소실내 혼합기의 불균질성에 관한 연구)

  • Lim, Ock-Taeck;Iida, Norimasa
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.12
    • /
    • pp.1043-1050
    • /
    • 2010
  • Fuel stratification and thermal stratification occur in the HCCI combustion chamber on a microscopic scale. They affect the ignition and combustion processes. In this study, the effect of the inhomogeneity in the mixture gas on the HCCI combustion process was investigated. Two-dimensional chemiluminescence images were captured using a framing camera to evaluate the flame structure. DME was used as the test fuel. First, the effect of inhomogeneity in the fuel distribution in the premixture was investigated for the four-stroke optically accessible engine. Then, by comparing the combustion of the homogeneous mixture in the rapid compression machine, which does not contain any residual gas, with the combustion in the four-stroke engine, the effect of inhomogeneity in temperature due to the residual gas was analyzed. The results showed that a time lag appears spatially in combustion under inhomogeneous conditions in the four-stroke engine. The spatial variation in the combustion without the residual gas in the rapid compression machine is less than that in the combustion in the four-stroke engine.