• 제목/요약/키워드: Flame Time

검색결과 710건 처리시간 0.025초

Flame Retardant Performance of Wood Treated with Flame Retardant Chemicals

  • Park, Hee-Jun;Mingyu-Wen, Mingyu-Wen;Cheon, Sang-Hun;Hwang, Jung-Woo;Oh, Seung-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • 제40권5호
    • /
    • pp.311-318
    • /
    • 2012
  • This study investigated the flame retardant performance of developed four types of flame retardant chemicals (FRC), FRC-A, B, C and D. Four kinds of soft wood species, Sugi (Cryptomeria), Spruce (Picea abies), Hinoki (Chamaecyparis obtusa) and Korean pine (Pinus koraiensis), were used. The wood specimens were treated by spreading the FRC on the surface with different quantities, 30, 50, 70, 90, 110 g/$m^2$, respectively. The charred area, charred length, after flame time and after glow time were tested. And their suitabilities as incombustible materials were evaluated. The specimen treated by FRC-D showed better incombustible properties than others, even though with lower quantity. Therefore it is supposed that the FRC-D could be able to be applied on the cultural heritage, such as Korean wooden house for preventing fire.

유동변수들이 석탄가스화에 미치는 민감도에 대한 수치적연구 (Parametric Sensitivity of the Flow Characteristics on Pulverized Coal Gasification)

  • 조한창;신현동
    • 한국연소학회지
    • /
    • 제4권1호
    • /
    • pp.1-15
    • /
    • 1999
  • In order to analyze the sensitivity on the pulverized coal flames of the several variables, a numerical study was conducted at the gasification process. Eulerian approach is used for the gas phase, whereas lagrangian approach is used for the solid phase. Turbulence is modeled using the standard $k-{\varepsilon}$ model. The turbulent combustion incorporates eddy dissipation model. The radiation was solved using a Monte-Carlo method. One-step two-reaction model was employed for the devolatilization of Kideco coal. In pulverized flame of long liftoff height, the initial turbulent intensity seriously affects the position of flame front. The radiation heat transfer and wall heat loss ratio distort the temperature distributions along the reactor wall, but do not influence the reactor performance such as coal conversion, residence time and flame front position. The primary/secondary momentum ratio affects the position of flame front, but the coal burnout is only slightly influenced. The momentum ratio is a variable only associated with the flame stabilization such as flame front position. The addition of steam in the reactor has a detrimental effect on all the aspects, particularly reactor temperature and coal burnout.

  • PDF

Upward Flame Spread for Fire Risk Classification of High-Rise Buildings

  • McLaggan, Martyn S.;Gupta, Vinny;Hidalgo, Juan P.;Torero, Jose L.
    • 국제초고층학회논문집
    • /
    • 제10권4호
    • /
    • pp.299-310
    • /
    • 2021
  • External fire spread has the potential to breach vertical compartmentation and violate the fire safety strategy of a building. The traditional design solution to this has been the use of non-combustible materials and spandrel panels but recent audits show that combustible materials are widespread and included in highly complex systems. Furthermore, most jurisdictions no longer require detailing of spandrel panels under many different circumstances. These buildings require rapid investigation using rational scientific methods to be able to adequately classify the fire risk. In this work, we use an extensive experimental campaign of material-scale data to explore the critical parameters driving upward flame spread. Two criteria are outlined using two different approaches. The first evaluates the time to ignition and the time to burnout to assess the ability for a fire to spread, and can be easily determined using traditional means. The second evaluates the preheated flame length as the critical parameter driving flame spread. A wide range of cladding materials are ranked according to these criteria to show their potential propensity to flame spread. From this, designers can use conservative approaches to perform fire risk assessments for buildings with combustible materials or can be used to aid decision-making. Precise estimates of flame spread rates within complex façade systems are not achievable with the current level of knowledge and will require a substantial amount of work to make progress.

일차원 액적 배열의 화염 퍼짐에 있어서 연료의 혼합 효과에 관한 연구 (A Study on Blend Effect of Fuel in Flame Spread Along An One-Dimensional Droplet Array)

  • 박정;소림수소;신강숭
    • 한국연소학회지
    • /
    • 제3권2호
    • /
    • pp.1-11
    • /
    • 1998
  • Experimental investigation on flame spread of blended fuel droplet arrays has been conducted for droplet diameters of 1.0mm and 0.75mm using high-speed chemiluminescence images of OH radical. The flame spread rate is measured with blended fuel composition, droplet diameter, and droplet spacing. Flame spread is categorized into two: a continuous mode and an intermittent one. There exist a limit droplet spacing, above which flame does not spread, and a droplet spacing of maximum flame spread, which is closely related to flame diameter. It is seen that flame spread rate is mainly dependent upon the relative position of flame zone within a droplet spacing. In case of large droplet, the increase of % volume of Heptane induces the shift of limit droplet spacing to a larger spacing since volatile Heptane plays a role of an enhancer of flame spread rate. In case of small droplet, the increase of % volume of Heptane leads to the shift of limit droplet spacing to a smaller droplet spacing. This is so because of the delayed chemical reaction time by the rapid increase of mass flux of fuel vapor for small droplet.

  • PDF

화재감지기를 사용한 발화점추적기반의 자동소방시스템 설계 및 구현 (Design and Implementation of the Automatic Fire Extinguishing System Based on the Ignition Point Tracking using the Flame Detecter)

  • 백승현;김영웅;오세일;박홍배
    • 대한임베디드공학회논문지
    • /
    • 제8권3호
    • /
    • pp.155-161
    • /
    • 2013
  • To reduce the personnel and material loss caused by fire, we propose the automatic fire extinguishing system based on the ignition point tracking using the flame detecter. This automatic fire extinguishing system is composed of the flame detecting system and the fire extinguishing system based on the water cannon. We study the method for the ignition point tracking and the automatic fire extinguishing using the water cannon and the flame detecter. The flame detecting system for the early fire detection and the ignition point tracking has to be satisfied the requirement of the detecting range and the flame detection time. So we study the signal process algorithm for an improvement of the flame detecting system.

$H_2/O_2$확산화염에서 전기수력학적 방법과 증발기에 의해 발생된 입자의 성장 비교에 관한 실험적 연구 (Experimental study on the Formation and Growth of Silica Particles in $H_2/O_2$ Diffusion Flame by Electro-Spraying Method and Evaporation)

  • 손성혁;육세진;안강호;최만수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.168-173
    • /
    • 2000
  • Flame aerosol synthesis technology refers to the formation of fine particles from gases in flame and is widely used in practical materials processing. In this paper, an experimental investigation was performed on growth of the silica particles that were generated in $H_2/O_2$ Diffusion Flame by the direct injection or TEOS using Electro-spraying method. in this flame aerosol synthesis, four main parameters or nos interaction (flame temperature, residence time or particle in flame, TEOS flow rate, applied voltage) for particle generation and growth was investigated along the axial direction above the burner. A fairly monodisperse non-aggregated particles were successfully obtained.

  • PDF

Evaluation Methods of Flame Retardants for Wooden Cultural Properties

  • Son, Dong Won;Han, Gyu-Seong
    • Journal of the Korean Wood Science and Technology
    • /
    • 제42권5호
    • /
    • pp.590-596
    • /
    • 2014
  • Wooden cultural heritages of Korea have been destroyed by fire in many cases. As a result, a number of methods to protect wooden cultural properties against fire were introduced. A way of protecting wooden cultural properties installations of fire equipments such as sprinkler, fire alarm system, or fire extinguisher. Another way of protecting wooden cultural properties is to treat them with flame retardants for their safety. Development of a very effective flame retardant with a good performance without affecting danchung and wood quality is required. At the same time, methods of evaluating flame retardant treated woods should be devised to assess their efficacy. In this study, combustion characteristics using cone-calorimeter, limit oxygen index, moisture absorption, iron corrosive and weathering were analyzed to evaluate the flame resistance efficacy and performance of flame retardants treated woods. The evaluation methods of flame retardants for wooden cultural heritage were suggested.

미분무 시스템이 장착된 화염방지장치의 화재 진화 특성에 관한 연구 (A Study on the Fire Suppression Characteristics of a Flame Arrester with Water Mist System)

  • 김해지;이경로
    • 한국기계가공학회지
    • /
    • 제15권5호
    • /
    • pp.117-124
    • /
    • 2016
  • In this paper, we developed a breather valve with a water mist system for use near an oil storage tank. Our process applied a water mist system to the flame arrester to evaluate the fire suppression characteristics. For the fire suppression evaluation of the water mist system, we evaluated the angle of the nozzle, fire suppression, spray particle size, flashback, fire suppression time, and fire suppression test of antifreeze. Through the fire suppression test, the best fire suppression nozzle used an angle of $140^{\circ}$, and the flashback phenomenon of flame arrester did not occur. The fire suppression time of water mist system time was within three seconds, and the antifreeze was no problem with the fire suppression.

고속분출화염이 연소에 미치는 영향에 관한 연구 (A study of turbulent jet flame effects on combustion)

  • 정경석;정인석;조경국
    • 오토저널
    • /
    • 제4권2호
    • /
    • pp.13-23
    • /
    • 1982
  • To understand the effects of turbulence on combustion, it was experimentally investigated in the combustion chamber with sub-chamber by using pressure record and high speed Schlieren motion picture. The results show that turbulence can increase the flame propagating rate and there exists a condition under which the total burning time becomes the minimum. And it was also found that there exist three kinds of flame propagating pattern and the total burning time can be reduced with the appropriate selection of sub-chamber size and orifice diameter.

  • PDF

목재 및 목질재료용 난연성 폴리우레탄수지 도막의 난연성능 (Performance on Flame-Retardant Polyurethane Coatings for Wood and Wood-based Materials)

  • 김종인;박종영;공영토;이병후;김현중;노정관
    • Journal of the Korean Wood Science and Technology
    • /
    • 제30권2호
    • /
    • pp.172-179
    • /
    • 2002
  • 본 연구에서는 MDF와 잣나무 판재에 대한 난연처리 및 난연도장 처리 시험편에 대한 난연 효과에 대해 고찰하였다. 무처리 MDF와 잣나무판재에 대한 td𝜃은 각각 279.5, 182.5로 나타났으나 난연침지 처리된 무늬단판을 오버레이한 MDF를 난연도장 처리 한 경우 높은 난연성능을 나타냈다. 난연처리한 잣나무판재에 난연도장 처리를 할 경우 th𝜃가 90으로 나타났고, 난연침지 처리 된 무늬단판이 오버레이 된 MDF에 난연도장처리한 경우에는 th𝜃가 0으로 나타난 가장 뛰어난 난연성능을 나타냈다. 전체적으로 난연처리 및 난연도장처리를 한 경우 th𝜃가 감소하는 것으로 나타나 난연성능이 개선되는 것으로 나타났다. 또한 연소도 시험결과 시험편의 중량감소율은 난연처리와 난연도장처리에 의해 감소함으로써 난연성능이 개선되는 것으로 나타났다. 또한 착화시간과 잔염시간의 측정결과도 유사하게 나타났으며 난연침지 처리 된 무늬단판이 오버레이 된 MDF 및 난연처리된 잣나무판재에 난연도장 처리한 경우 무처리된 경우에 비해 착화시간은 증가되고, 잔염시간은 감소하는 것으로 나타났다.