• Title/Summary/Keyword: Flame Time

Search Result 710, Processing Time 0.025 seconds

Flame Retardant Performance of Wood Treated with Flame Retardant Chemicals

  • Park, Hee-Jun;Mingyu-Wen, Mingyu-Wen;Cheon, Sang-Hun;Hwang, Jung-Woo;Oh, Seung-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.40 no.5
    • /
    • pp.311-318
    • /
    • 2012
  • This study investigated the flame retardant performance of developed four types of flame retardant chemicals (FRC), FRC-A, B, C and D. Four kinds of soft wood species, Sugi (Cryptomeria), Spruce (Picea abies), Hinoki (Chamaecyparis obtusa) and Korean pine (Pinus koraiensis), were used. The wood specimens were treated by spreading the FRC on the surface with different quantities, 30, 50, 70, 90, 110 g/$m^2$, respectively. The charred area, charred length, after flame time and after glow time were tested. And their suitabilities as incombustible materials were evaluated. The specimen treated by FRC-D showed better incombustible properties than others, even though with lower quantity. Therefore it is supposed that the FRC-D could be able to be applied on the cultural heritage, such as Korean wooden house for preventing fire.

Parametric Sensitivity of the Flow Characteristics on Pulverized Coal Gasification (유동변수들이 석탄가스화에 미치는 민감도에 대한 수치적연구)

  • Cho, Han-Chang;Shin, Hyun-Dong
    • Journal of the Korean Society of Combustion
    • /
    • v.4 no.1
    • /
    • pp.1-15
    • /
    • 1999
  • In order to analyze the sensitivity on the pulverized coal flames of the several variables, a numerical study was conducted at the gasification process. Eulerian approach is used for the gas phase, whereas lagrangian approach is used for the solid phase. Turbulence is modeled using the standard $k-{\varepsilon}$ model. The turbulent combustion incorporates eddy dissipation model. The radiation was solved using a Monte-Carlo method. One-step two-reaction model was employed for the devolatilization of Kideco coal. In pulverized flame of long liftoff height, the initial turbulent intensity seriously affects the position of flame front. The radiation heat transfer and wall heat loss ratio distort the temperature distributions along the reactor wall, but do not influence the reactor performance such as coal conversion, residence time and flame front position. The primary/secondary momentum ratio affects the position of flame front, but the coal burnout is only slightly influenced. The momentum ratio is a variable only associated with the flame stabilization such as flame front position. The addition of steam in the reactor has a detrimental effect on all the aspects, particularly reactor temperature and coal burnout.

  • PDF

Upward Flame Spread for Fire Risk Classification of High-Rise Buildings

  • McLaggan, Martyn S.;Gupta, Vinny;Hidalgo, Juan P.;Torero, Jose L.
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.4
    • /
    • pp.299-310
    • /
    • 2021
  • External fire spread has the potential to breach vertical compartmentation and violate the fire safety strategy of a building. The traditional design solution to this has been the use of non-combustible materials and spandrel panels but recent audits show that combustible materials are widespread and included in highly complex systems. Furthermore, most jurisdictions no longer require detailing of spandrel panels under many different circumstances. These buildings require rapid investigation using rational scientific methods to be able to adequately classify the fire risk. In this work, we use an extensive experimental campaign of material-scale data to explore the critical parameters driving upward flame spread. Two criteria are outlined using two different approaches. The first evaluates the time to ignition and the time to burnout to assess the ability for a fire to spread, and can be easily determined using traditional means. The second evaluates the preheated flame length as the critical parameter driving flame spread. A wide range of cladding materials are ranked according to these criteria to show their potential propensity to flame spread. From this, designers can use conservative approaches to perform fire risk assessments for buildings with combustible materials or can be used to aid decision-making. Precise estimates of flame spread rates within complex façade systems are not achievable with the current level of knowledge and will require a substantial amount of work to make progress.

A Study on Blend Effect of Fuel in Flame Spread Along An One-Dimensional Droplet Array (일차원 액적 배열의 화염 퍼짐에 있어서 연료의 혼합 효과에 관한 연구)

  • Park, Jeong;Kobayashi, Hideaki;Niioka, Takashi
    • Journal of the Korean Society of Combustion
    • /
    • v.3 no.2
    • /
    • pp.1-11
    • /
    • 1998
  • Experimental investigation on flame spread of blended fuel droplet arrays has been conducted for droplet diameters of 1.0mm and 0.75mm using high-speed chemiluminescence images of OH radical. The flame spread rate is measured with blended fuel composition, droplet diameter, and droplet spacing. Flame spread is categorized into two: a continuous mode and an intermittent one. There exist a limit droplet spacing, above which flame does not spread, and a droplet spacing of maximum flame spread, which is closely related to flame diameter. It is seen that flame spread rate is mainly dependent upon the relative position of flame zone within a droplet spacing. In case of large droplet, the increase of % volume of Heptane induces the shift of limit droplet spacing to a larger spacing since volatile Heptane plays a role of an enhancer of flame spread rate. In case of small droplet, the increase of % volume of Heptane leads to the shift of limit droplet spacing to a smaller droplet spacing. This is so because of the delayed chemical reaction time by the rapid increase of mass flux of fuel vapor for small droplet.

  • PDF

Design and Implementation of the Automatic Fire Extinguishing System Based on the Ignition Point Tracking using the Flame Detecter (화재감지기를 사용한 발화점추적기반의 자동소방시스템 설계 및 구현)

  • Paik, Seung Hyun;Kim, Young Wung;Oh, Se Il;Park, Hong Bae
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.8 no.3
    • /
    • pp.155-161
    • /
    • 2013
  • To reduce the personnel and material loss caused by fire, we propose the automatic fire extinguishing system based on the ignition point tracking using the flame detecter. This automatic fire extinguishing system is composed of the flame detecting system and the fire extinguishing system based on the water cannon. We study the method for the ignition point tracking and the automatic fire extinguishing using the water cannon and the flame detecter. The flame detecting system for the early fire detection and the ignition point tracking has to be satisfied the requirement of the detecting range and the flame detection time. So we study the signal process algorithm for an improvement of the flame detecting system.

Experimental study on the Formation and Growth of Silica Particles in $H_2/O_2$ Diffusion Flame by Electro-Spraying Method and Evaporation ($H_2/O_2$확산화염에서 전기수력학적 방법과 증발기에 의해 발생된 입자의 성장 비교에 관한 실험적 연구)

  • Sohn, S.H.;Yook, S.J.;Ah, K.H.;Choi, M.S.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.168-173
    • /
    • 2000
  • Flame aerosol synthesis technology refers to the formation of fine particles from gases in flame and is widely used in practical materials processing. In this paper, an experimental investigation was performed on growth of the silica particles that were generated in $H_2/O_2$ Diffusion Flame by the direct injection or TEOS using Electro-spraying method. in this flame aerosol synthesis, four main parameters or nos interaction (flame temperature, residence time or particle in flame, TEOS flow rate, applied voltage) for particle generation and growth was investigated along the axial direction above the burner. A fairly monodisperse non-aggregated particles were successfully obtained.

  • PDF

Evaluation Methods of Flame Retardants for Wooden Cultural Properties

  • Son, Dong Won;Han, Gyu-Seong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.5
    • /
    • pp.590-596
    • /
    • 2014
  • Wooden cultural heritages of Korea have been destroyed by fire in many cases. As a result, a number of methods to protect wooden cultural properties against fire were introduced. A way of protecting wooden cultural properties installations of fire equipments such as sprinkler, fire alarm system, or fire extinguisher. Another way of protecting wooden cultural properties is to treat them with flame retardants for their safety. Development of a very effective flame retardant with a good performance without affecting danchung and wood quality is required. At the same time, methods of evaluating flame retardant treated woods should be devised to assess their efficacy. In this study, combustion characteristics using cone-calorimeter, limit oxygen index, moisture absorption, iron corrosive and weathering were analyzed to evaluate the flame resistance efficacy and performance of flame retardants treated woods. The evaluation methods of flame retardants for wooden cultural heritage were suggested.

A Study on the Fire Suppression Characteristics of a Flame Arrester with Water Mist System (미분무 시스템이 장착된 화염방지장치의 화재 진화 특성에 관한 연구)

  • Kim, Hae-Ji;Lee, Kyung-Ro
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.5
    • /
    • pp.117-124
    • /
    • 2016
  • In this paper, we developed a breather valve with a water mist system for use near an oil storage tank. Our process applied a water mist system to the flame arrester to evaluate the fire suppression characteristics. For the fire suppression evaluation of the water mist system, we evaluated the angle of the nozzle, fire suppression, spray particle size, flashback, fire suppression time, and fire suppression test of antifreeze. Through the fire suppression test, the best fire suppression nozzle used an angle of $140^{\circ}$, and the flashback phenomenon of flame arrester did not occur. The fire suppression time of water mist system time was within three seconds, and the antifreeze was no problem with the fire suppression.

A study of turbulent jet flame effects on combustion (고속분출화염이 연소에 미치는 영향에 관한 연구)

  • 정경석;정인석;조경국
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.4 no.2
    • /
    • pp.13-23
    • /
    • 1982
  • To understand the effects of turbulence on combustion, it was experimentally investigated in the combustion chamber with sub-chamber by using pressure record and high speed Schlieren motion picture. The results show that turbulence can increase the flame propagating rate and there exists a condition under which the total burning time becomes the minimum. And it was also found that there exist three kinds of flame propagating pattern and the total burning time can be reduced with the appropriate selection of sub-chamber size and orifice diameter.

  • PDF

Performance on Flame-Retardant Polyurethane Coatings for Wood and Wood-based Materials (목재 및 목질재료용 난연성 폴리우레탄수지 도막의 난연성능)

  • Kim, Jong-In;Park, Jong-Young;Kong, Young-To;Lee, Byoung-Hoo;Kim, Hyun-Joong;Roh, Jeang-Kwan
    • Journal of the Korean Wood Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.172-179
    • /
    • 2002
  • In this study, two materials treated with a flame retardant were examined for their fire resistance. The first, MDF (medium density fiberboard) was overlaid by an oak sliced veneer, which was either treated by soaking in a 6wt.% solution of flame retardant chemicals (pentabromine-chlorinated paraffin) or non-treated and then was coated with either a flame retardant polyurethane coating or with a common polyurethane coating. The second material, Pinus koraiensis penal was either treated by a spray treatment using a flame retardant solution or non-treated and then was coated with either a flame retardant polyurethane coating or with a common polyurethane coating. Pentabromine-chorinated paraffin chemicals were added (6 part of urethane resin) as the flame retardant chemicals in the polyurethane coatings. In the fire resistance test, the th𝜃(℃·min) decreased with the flame retardant treatment or/and the flame retardant coatings, compared to the untreated sample Weight loss (%) decreased with the flame retardant treatment or/and the flame retardant coatings. The ignition time (sec.) increased and the residual flame time (sec.) decreased with the flame retardant treatment or/and flame retardant coatings. Therefore, the flame retardant treatment or/and flame retardant polyurethane coatings have excellent incombustibility.