• 제목/요약/키워드: Flame Structure

검색결과 609건 처리시간 0.025초

막재료의 난연 및 방염성능 실험에 대한 연구 (Tests of Fire and Flame Retardant Performance for Membrane Materials)

  • 김기철;최광호
    • 한국공간구조학회논문집
    • /
    • 제16권2호
    • /
    • pp.55-60
    • /
    • 2016
  • The Membrane structure has a number of problems in the application of a fireproof code based on general buildings codes. Thus, the fireproof code of membrane structure is necessary to activate the construction of the membrane structure. Because it requires a systematic classification of fire retardant and flame proof performance of membrane material. Fire retardant and flame proof tests are conducted on membrane materials mostly used in current construction to propose the fire and flame retardant performance criteria of membrane materials. Fire and flame retardant tests results, PTFE membrane material with the glass fiber fabric have a limit-combustible performance. PVDF membrane material with the polyester fabric does not ensure the fire retardant performance, but this membrane material has the flame retardant performance of a thick fabric. Also, ETFE does not ensure the fire retardant performance, but this membrane material has the flame retardant of a thin fabric.

난류확산화염의 화염구조와 연소특성에 관한 실험적 연구 (An Experimental Study on Flame Structure and Combustion Characteristics of Turbulent Diffusion Flame(I))

  • 최병륜;장인갑;최경민
    • 대한기계학회논문집B
    • /
    • 제20권3호
    • /
    • pp.1028-1039
    • /
    • 1996
  • This study was focused on the examination of the flame structure and the combustion characteristics of diffusion flame which was formed the turbulent shear flow of a double coaxial air jet system. The shear flow was formed by the difference velocity of surrounding air jet(U$\_$s/) and center air jet (U$\_$c/). So experimental condition was divided S-type flame (.lambda. > 1) and C-type flame (.lambda. < 1) by velocity ratio .lambda. (=U$\_$s//U$\_$c/). For examination of the flame structure and the combustion characteristics in diffusion flame, coherent structure was observed in flame by schlieren photograph method. We measured fluctuating temperature and ion current simultaneously and accomplished the statistical analysis of its. According to schlieren photograph, the flame was stabilized in the rim of the direction of lower velocity air jet, coherent eddy was produced and developed by higher velocity air jet. The statistical data of fluctuating temperature and ion current was indicated that reaction was dominated by higher velocity air jet. The mixing state of burnt gas and non-burnt gas was distributed the wide area at Z = 100 mm of C-type flame.

정상 중력장에서 낮은 스트레인율을 갖는 대향류 비예혼합화염의 소화한계 (Extinction Limits of Low Strain Rate Counterflow Nonpremixed Flames in Normal Gravity)

  • 오창보;최병일;김정수;;박정
    • 대한기계학회논문집B
    • /
    • 제29권9호
    • /
    • pp.997-1005
    • /
    • 2005
  • The extinction characteristics of low strain rate normal gravity (1-g) nonpremixed methane-air flames were studied numerically and experimentally. A time-dependent axisymmetric two-dimensional (2D) model considering buoyancy effects and radiative heat transfer was developed to capture the structure and extinction limits of 1-g flames. One-dimensional (1D) computations were also conducted to provide information on 0-g flames. A 3-step global reaction mechanism was used in both the 1D and 2D computations to predict the measured extinction limit and flame temperature. A specific maximum heat release rate was introduced to quantify the local flame strength and to elucidate the extinction mechanism. Overall fractional contribution by each term in the energy equation to the heat release was evaluated to investigate the multi-dimensional structure and radiative extinction of 1-g flames. Images of flames were taken for comparison with the model calculation undergoing extinction. The two-dimensional numerical model was validated by comparing flame temperature profiles and extinction limits with experiments and ID computation results. The 2D computations yielded insight into the extinction mode and flame structure of 1-g flames. Two combustion regimes depending on the extinction mode were identified. Lateral heat loss effects and multi-dimensional flame structure were also found. At low strain rates of 1-g flame ('Regime A'), the flame is extinguished from the weak outer flame edge, which is attributed to multi-dimensional flame structure and flow field. At high strain rates, ('Regime B'), the flame extinction initiates near the flame centerline due to an increased diluent concentration in reaction zone, which is the same as the extinction mode of 1D flame. These two extinction modes could be clearly explained with the specific maximum heat release rate.

벽면조건에 의한 미소관내 화염 전파 특성 변화에 관한 수치해석 (A numerical study on the characteristics of flame propagation in small tubes under various boundary conditions)

  • 김남일;카오루마루타
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제32회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.32-38
    • /
    • 2006
  • A premixed flame propagating in a tube suffers strong variation in its shape and structure depending on boundary conditions. The effects of thermal boundary conditions and flow fields on flame propagation are numerically investigated. Navier-Stokes equations and species equations are solved with a one-step irreversible global reaction model of methane-air mixture. Finite volume method using an adaptive grid method is applied to investigate the flame structure. In the case of an adiabatic wall, friction force on the wall significantly affected the flame structure while in the case of an isothermal wall, local quenching near the wall dominated flame shapes and propagation. In both cases, variations of flow fields occurred not only in the near field of the flame but also within the flame itself, which affected propagation velocities. This study provides an overview of the characteristics of flames in small tubes at a steady state.

  • PDF

난류확산화염의 화염구조와 연소특성에 관한 실험적 연구 (An Experimental Study on Flame Structure and Combustion Characteristics of Turbulent Diffusion Flame(III))

  • 장인갑;최경민;최병륜
    • 대한기계학회논문집B
    • /
    • 제20권7호
    • /
    • pp.2326-2336
    • /
    • 1996
  • So most practical combustor is considered to the swirl flame, it is very important to examinate swirl flame structure and combustion characteristics. Recently, attention has been paid to the flame diagnostic by radical luminous intensity. For swirl flame structure and combustion characteristic, reverse flow boundary, temperature, ion current and radical luminous intensity were measured in the double-coaxial swirl combustor which was used principle of multi-annular combustor. This study had three experimental condition, S-type, C-type, SC-type. S-type and C-type flames were formed recirculation zone, but SC-type flame wasn't formed. C-type flame had two recirculation zone. The position with maximum value of ion current and CH-radical, temperature and OH-radical had similarity distribution almost. Therefore, it is possible that the macro structure of flame was measured by radical luminous intensity in the high intensity of turbulent combustion field which was formed by swirl.

로브형 버너에서의 NOx 배출 특성에 관한 연구 (A Study of Characteristics of NOx Emission in Lobed Burner)

  • 조한창;조길원;이용국
    • 한국연소학회지
    • /
    • 제6권1호
    • /
    • pp.1-6
    • /
    • 2001
  • To evaluate the effect of lobed structure on pollutant emission, an experimental study examines NOx and CO emissions associated with four burner geometries, such as a conventional circular burner and three lobed ones. Rapid mixing allowed by the lobed burner to produce lean premixed flames, with narrower flame stability diagram than for the conventional circular one. Conventional circular burner of wide and uniform burner rim has an advantage of flame stabilization. Correlation on fuel discharge velocity for flame blowout should be included a variable related to the wall effect of the burner. NOx emission reduces by about 5% at the burner with lobed structure in fuel discharge side compared to conventional circular one. This is due to lower flame temperatures through flame elongation and increased radiative heat losses, caused by partially luminous flame in flame front. Meanwhile, at the burner with lobed structure in air discharge side and both fuel and air discharge sides, NOx emission somewhat increases with reduced radiative heat losses in spite of flame elongation. Therefore, the rapid mixing by lobed structure does not always have an advantage on NOx reduction.

  • PDF

메탄/공기 층류 부분예혼합화염의 화염구조와 NOx 배출특성 : 연료분배율과 혼합거리의 영향 (Flame Structure and NOx Emission Characteristics in Laminar Partially Premixed CH4/Air Flames: Effects of Fuel Split Percentage and Mixing Distance)

  • 정용기;이종호;이석영;전충환;장영준
    • 대한기계학회논문집B
    • /
    • 제28권7호
    • /
    • pp.818-825
    • /
    • 2004
  • In this paper, the study of effects of flow parameters on flame structure and NOx emission concentration was performed in co-axial. laminar partially premixed methane/air flames. Such (low parameters as equivalence ratio(${\Phi}$), fuel split percentage($\sigma$), and mixing distance(x/D$\_$i/) were defined as a premixing degree and varied within ${\Phi}$=1.36∼9.52, $\sigma$=50∼100, and x/D$\_$i/=5∼20. The image of OH$\^$*/ and NOx concentration were obtained with an ICCD camera and a NOx analyzer. The flame structure observations show a categorization of partially premixed flames into three distinct flame regimes corresponding to ${\Phi}$<1.7(premixed flame structure), 1.7<${\Phi}$<3.3(hybrid structure), and ${\Phi}$>3.3(diffusion flame structure existing a luminous sooting region) at $\sigma$=75%, and x/D$\_$i/=10. As o decreases from 100% to 50%, and x/D$\_$i/ decreases, nonpremixed flame structure appear at low equivalence ratio relatively. In addition, the measured emissions for NOx rise steeply from ${\Phi}$=1.7, to ${\Phi}$=3.3, then constants ${\Phi}$>4.76. NOx emissions decrease with increase the level of premixing level. In conclusion, the main effect on flame structure and NOx production was at first equivalence ratio(${\Phi}$), and next fuel split percentage($\sigma$), and finally mixing distance(x/D$\_$i/).

Non-premixed Hydrogen Flame Structure in Supersonic Coflowing Air Flows

  • Kim, Ji-Ho;Kim, Je-Hung;Yoon, Young-Bin;Park, Chul-Woung;Hahn, Jae-Won
    • 한국연소학회지
    • /
    • 제7권1호
    • /
    • pp.1-7
    • /
    • 2002
  • Experiments have been performed to investigate the structure of axisymmetric hydrogen diffusion flame in a supersonic coflow air. The characteristics and structure of supersonic flames are compared with those of subsonic flames as the velocity of coflow air increases from subsonic to supersonic velocity of Mach 1.8. Also, the subsonic and supersonic flow fields are analyzed numerically for the non-reacting conditions and the possible flame contours indicated by fuel mass fraction are compared with the measured OH radical distributions. It is found that the flame structure indicates more like a partially premixed flame as the coflow air velocity is increased from subsonic to supersonic regimes; strong reaction zone indicated by intense OH signal is found at the center, which is different from subsonic flame cases. And it is shown that the fuel jet passes along the recirculation zones behind the bluff-body fuel nozzle resulting in relatively long mixing time. This is believed to be the reason of the partially premixed flame characteristics found in the present supersonic flames.

  • PDF

확대유로내의 Bluff-Body 후류확산화염의 구조 및 특성 2 (Structure and Characteristics of Diffusion Flaame behind a Bluff-body in a Divergent Flow(II))

  • 최병륜;이중성
    • 대한기계학회논문집
    • /
    • 제19권11호
    • /
    • pp.2981-2994
    • /
    • 1995
  • In order to elucidate the effects of positive pressure gradient on flame properties, structure and stabilization, an experimental study is made on turbulent diffusion flame stabilized by a circular cylinder in a divergent duct flow. A commercial grade gaseous propane is injected from two slits on the rod as fuel. In this paper, stabilization, characteristics and flame structure are examined by varying the divergent angle of duct. Temperature, ion current and Schlieren photographs were measured. It is found that critical divergent angle is expected to be about 8 ~ 12 degree through blow-off velocity pattern to divergent angle and the positive pressure gradient influences the flame temperature, intensity of ion current and eddy structure behind the rod. With the increase of divergent angle, typical temperature of recirculation zone is low but intensity of ion current is high in shear layer behind rod. Energy distributions of fluctuating temperature and ion current signals turn up low frequency corresponding to large scale eddies but high frequency corresponding to small scale eddies as well as low with the increase of divergent angle. Therefore the flame structure becomes a typical distributed-reacting flame.

Basis Mode of Turbulent Flame in a Swirl-Stabilized Gas Turbine using LES and POD

  • Sung, Hong-Gye;Yang, Vigor
    • 한국연소학회지
    • /
    • 제6권2호
    • /
    • pp.29-35
    • /
    • 2001
  • Unsteady numerical study has been conducted on combustion dynamics of a lean-premixed swirl-stabilized gas turbine swirl injector. A three-dimensional computation method utilizing the message passing interface (MPI) parallel architecture, large eddy simulation(LES), and proper orthogonal decomposition (POD) technique was applied. The unsteady turbulent flame dynamics are simulated so that the turbulent flame structure can be characterized in detail. It was observed that some fuel lumps escape from the primary combustion zone, and move downstream and consequently produce hot spots. Those flame dynamics coincides with experimental data. In addition, basis modes of the unsteady turbulent flame are characterized using proper orthogonal decomposition (POD) analysis. The flame structure based on odd basis modes is apparently larger than that of even ones. The flame structure can be extracted from the summation of the basis modes and eigenvectors at any moment.

  • PDF