• Title/Summary/Keyword: Flame Detection

Search Result 196, Processing Time 0.029 seconds

Distribution characteristics of hexabromocyclododecanes in crucian carp and sediment from the major rivers (우리나라 하천에 서식하는 붕어와 주변 퇴적토에 축적된 HBCDs의 분포 특성)

  • Lee, Sumin;Kim, Seongwook;Jeong, Gi Ho
    • Analytical Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.321-332
    • /
    • 2014
  • The accumulation levels of hexabromocyclododecanes (HBCDs) were measured in samples of muscle tissue from crucian carp (Carassius auratus) and also in samples of associated sediments. Samples were collected from 15 sites along the courses of four major rivers. Widespread contamination by HBCDs in this area was identified from the results of this investigation. HBCDs were found above the detection limit from all of the sampling sites. The ${\Sigma}HBCDs$ (sum of ${\alpha}$-, ${\beta}$-, and ${\gamma}$-HBCDs) levels ranged from 1.3 to 19 ng/g (lipid wt) in the crucian carp musscle tissue samples, and from 0.17 to 30 ng/g (dry wt) in the associated sediment samples. The predominance of ${\alpha}$-diastereomer in the muscle tissue of the carp and ${\gamma}$-diastereomer in the sediments was identified, accounting for 88% and 60% of the ${\Sigma}HBCDs$, respectively. The ${\Sigma}HBCDs$ levels in the muscle tissue samples of carp collected from the upstream sections of each river were much lower than those in the samples from carp in the downstream sections. In addition, the ${\Sigma}HBCDs$ levels in carp tissue samples from an isolated site were much lower than those in carp collected from the sites along the major rivers. This suggests that HBCD contamination in the rivers is likely to be sourced from the environment adjacent to them.

Preconcentration and Extraction of Copper on Activated Carbon Using 4-Amino-2, 3-dimethyl-1-phenyl-3-pyrazoline or 4-(4-methoxybenzylidenimin) thiophenole (4-Amino-2,3-dimethyl-1-phenyl-3-pyrazoline 또는 4-(4-Methoxybenzylidenimin)thiophenole을 이용한 활성탄에서의 구리의 예비 농축 및 추출)

  • Ghaedi, Mehrorang;Ahmadi, Farshid;Karimi, Hajir;Gharaghani, Shiva
    • Journal of the Korean Chemical Society
    • /
    • v.50 no.1
    • /
    • pp.23-31
    • /
    • 2006
  • carbon modified methods were used for the preconcentration and determination of copper in some real samples using the flame atomic absorption spectrometry. The copper ions was adsorbed quantitatively on the activated carbon due to their complexation with 4- amino-2, 3-dimethyl-1-phenyl-3-pyrazoline (ADMPP) or 4-(4- methoxybenzylidenimin) thiophenole (MBITP). The adsorbed copper on solid phase was eluted quantitatively using small amount of nitric acid. The influence of important parameters including pH, amount of carrier, flow rate, amount of activated carbon and type and concentration of eluting agent for obtaining maximum recovery were investigated. The methods based on ADMPP and MBITP at optimum conditions is linear over concentration range of 0.05-1.5 g mL-1 and 0.05-1.2 g mL-1 of copper with correlation coefficient of 0.9997 and 0.9994 and both detection limit of 1.4 ng mL-1, respectively. The preconcentration leads to enrichment factor of 310 and break through volume of 1550 mL for both ligands. The method has a good tolerance limit of interfering ion and a selectivity that has been successfully applied for the determination of copper content in real sample such as tap, spring, river and waste water.

The Control System of Wood Pellet Boiler Based on Home Networks (홈 네트워크 기반의 펠릿 활용 난방 보일러 제어시스템)

  • Lee, Sang-Hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.15 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • This paper presents the implementation of a control system of pellet boiler using wood pellet as carbon neutral material. The system also has the additional features to provide remote controlling and monitoring based on home networking technology through either public switched telephone networks or mobile communication networks. It consists of three kinds of sub-modules; a main controller provides basic and additional features such as a setting of temperature, a supplying of wood pellet, a controlling of ignition and fire-power, and a removing of soot. The second is temperature controller of individual rooms which is connected to the main controller through RS-485 links. And interface modules with PSTN and mobile networks can support remote controlling and monitoring the functions. The test results under the heating area of $172m^2$ show a thermal efficiency of 93.6%, a heating power of 20,640kcal/hr, and a fuel consumption of 5.54kg/hr. These results are superior to those of the conventional pellet boilers. In order to obtain the such high performance, we newly applied a 3-step ignition flow, a flame detection by $C_dS$ sensor, and a fire-power control by fine controlling of shutter to our pellet boiler.

A Study on u-CCTV Fire Prevention System Development of System and Fire Judgement (u-CCTV 화재 감시 시스템 개발을 위한 시스템 및 화재 판별 기술 연구)

  • Kim, Young-Hyuk;Lim, Il-Kwon;Li, Qigui;Park, So-A;Kim, Myung-Jin;Lee, Jae-Kwang
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.463-466
    • /
    • 2010
  • In this paper, CCTV based fire surveillance system should aim to development. Advantages and Disadvantages analyzed of Existing sensor-based fire surveillance system and video-based fire surveillance system. To national support U-City, U-Home, U-Campus, etc, spread the ubiquitous environment appropriate to fire surveillance system model and a fire judgement technology. For this study, Microsoft LifeCam VX-1000 using through the capturing images and analyzed for apple and tomato, Finally we used H.264. The client uses the Linux OS with ARM9 S3C2440 board was manufactured, the client's role is passed to the server to processed capturing image. Client and the server is basically a 1:1 video communications. So to multiple receive to video multicast support will be a specification. Is fire surveillance system designed for multiple video communication. Video data from the RGB format to YUV format and transfer and fire detection for Y value. Y value is know movement data. The red color of the fire is determined to detect and calculate the value of Y at the fire continues to detect the movement of flame.

  • PDF

Relationships between Fatty Acids and Tocopherols of Conventional and Genetically Modified Peanut Cultivars Grown in the United States (미국산 전통품종과 유전자 재조합 땅콩품종의 지방산과 토코페롤의 상관관계)

  • Shin, Eui-Cheol
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.10
    • /
    • pp.1618-1628
    • /
    • 2013
  • Relationships between fatty acids and tocopherols in conventional and genetically modified peanut cultivars were studied by gas chromatography with flame ion detector and high performance liquid chromatography with fluorescence detection. Eight fatty acids and four tocopherol isomers in the sample set were identified and quantified. Oleic acid and linoleic acid are major fatty acids and the ratio of oleic and linoleic acids ranged from 1.11 to 16.26. Tocopherols contents were 6.76 to 12.24 for ${\alpha}$-tocopherol (T), 0.08 to 0.39 for ${\beta}$-T, 5.28 to 15.02 for ${\gamma}$-T, and 0.17 to 1.17 mg/100 g for ${\delta}$-T. Correlation coefficient (r) for fatty acids and tocopherols indicated a strong inverse relationship between oleic & linoleic acids (r=-0.97, P<0.05) and positive relationships between palmitic & linoleic acids (r=0.95, P<0.05) and ${\gamma}$-T & ${\delta}$-T (r=0.83, P<0.05). Principal component analysis (PCA) of fatty acids and tocopherols gave four significant principal components (PCs, with eigenvalues>1), which together account for 85.49% of the total variance in the data set with PC1 and PC2 contributing 45.27% and 21.33% of the total variability, respectively. Eigen analysis of the correlation matrix loadings of the four significant PCs revealed that PC1 was mainly contributed by palmitic, oleic, linoleic, and gondoic acids, while PC2 was by behenic acid, ${\beta}$-T, and ${\gamma}$-T. The score plot generated by PC1-PC2 identified sample clusters in the two spatial planes based on the oleic and linoleic acids. The score plot PC3-PC4 didn't separate sample groups.

A Study on Migration of Ethylenediamine and Hexamethylenediamine from Polyamide Utensils (Polyamide 조리기구로부터 Ethylenediamine 및 Hexamethylenediamine의 이행에 관한 연구)

  • Eom, Mi-Ok;Kwak, In-Shin;Yoon, Hae-Jung;Jeon, Dae-Hoon;Choi, Hyun-Chul;Kim, Hyung-Il;Sung, Jun-Hyun;Park, Na-Young;Kim, So-Hee;Lee, Young-Ja
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.1
    • /
    • pp.36-42
    • /
    • 2010
  • The method for the determination of ethylenediamine (EDA) and hexamethylenediamine (HMDA) in food simulants was developed, and migration amounts of these compounds was monitored for 124 polyamide (PA) utensils. The diurethane derivatives of EDA and HMDA, which produced by reaction with ethyl chloroformate, were analyzed by using gas chromatograph (GC)/flame ionization detector (FID) and GC/mass spectrometer (MS). The developed method was validated with $0.3\;{\mu}g/mL$ of limit of detection (LOD) for EDA and $0.1\;{\mu}g/mL$ of LOD for HMDA, > 0.999 of linearity($r^2$) and > 88% of recovery. The EDA was detected 1.31 and $02.06\;{\mu}g/mL$ for 2 samples in water. The HMDA was detected $0.29\;-\;0.93\;{\mu}g/mL$ for 3 samples in 20% ethanol and $0.26\;-\;0.44\;{\mu}g/mL$ for 10 samples in n-heptane. These migration levels were below the specific migration limits (SML) of $12\;{\mu}g/mL$ and $2.4\;{\mu}g/mL$ for EDA and HMDA established in EU.