• Title/Summary/Keyword: Fixture shape

Search Result 50, Processing Time 0.026 seconds

A Convergence Study through the Structural Analysis due to the Shape of Automotive Roof Rack (자동차 루프랙의 형상에 따른 구조 해석을 통한 융합 연구)

  • Choi, Kye-Kwang;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.12
    • /
    • pp.257-262
    • /
    • 2019
  • Recently, the number of people enjoying various leisure sports has increased. As a result, the vehicles with various items loaded onto the roof can be easily seen on the street. The device that enables loading on the vehicle roof is called by a rack, and each vehicle has its own different shape. There are various types of roof racks but they must have the strength and durability to load heavy loads. In this study, the structural analysis was performed according to the support method of the roof rack and the shape of the fixture. Of three models, it was shown that model C had the best durability. Therefore, this study result shows which shape of the roof rack is most stable among the models. By utilizing the design data about a convergence study through the structural analysis due to the shape of automotive roof rack obtained on the basis of this result, the esthetic feeling can be shown by being converged onto the part of automobile at actual life.

Finite Element Stress Analysis in Supporting Bone according to Crest Module Shape of Fixture in Internal Connection System (내측연결 시스템에서 임플란트 고정체의 경부 형태에 따른 지지골에서의 유한요소 응력분석)

  • Park, Young-Nam;Kim, Hee-Jung;Oh, Sang-Ho;Chung, Chae-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.1
    • /
    • pp.55-74
    • /
    • 2006
  • The external contour of an implant can have significant effects on the load transfer characteristics and may result in different bone failure rates for different implant system. The purpose of this study was to investigate the effects of crest module shape and occlusal load direction on bone failure modes of five commercially available dental implant systems. Five different implant systems with internal connection; ITI (Model 1), Astra (Model 2), Bicon (Model 3), Friadent (Model 4), and Paragon (Model 5), comparable in size, but different in thread profile and cest module shapes, were compared using the finite element method. Conclusively, in the internal connection system of the implant-abutment connection methods, the stress-induced pattern at the supporting bone according to the abutment connection form had differenence among them, and implants with narrowing crestal module cross-sections at the top of the cortical bone created more favorable load transfer characteristics in this region. But it is considered that the future study is necessary about how this difference in the magnitude of the stress have an effect on the practical clinic.

Hybrid Technology using 3D Printing and 5-axis Machining for Development of Prototype of the Eccentric Drive System (편심구동장치 시제품 개발을 위한 3D프린팅-5축가공 복합기술)

  • Hwang, Jong-Dae;Yang, Jun-Seok;Yun, Sung-Hwan;Jung, Yoon-Gyo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.2
    • /
    • pp.38-45
    • /
    • 2016
  • Since a 5-axis machine tool has two rotary axes, it offers numerous advantages, such as flexible accessibility, longer tool life, better surface finish, and more accuracy. Moreover, it can conduct whole machining by rotating the rotary feed axes while setting the fixture at once without re-fixing in contrast to conventional 3-axis machining. However, it is difficult to produce complicated products that have a hollow shape. In contrast, 3D printing can produce an object with a complicated hollow shape easily and rapidly. However, because of layer thickness and shrinkage, its surface finish and dimensional accuracy are not adequate. Therefore, this study proposes hybrid technology by integrating the advantages of these two manufacturing processes. 3D printing was used as the additive manufacturing rapidly in the whole body, and 5-axis machining was used as the subtractive manufacturing accurately in the joining and driving places. The reliability of the proposed technology was verified through a comparison with conventional technology in the aspects of processing time, surface roughness. and dimensional accuracy.

Development of Microscale RF Chip Inductors for Wireless Communication Systems (무선통신시스템을 위한 극소형 RF 칩 인덕터의 개발)

  • 윤의중;김재욱;정영창;홍철호
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.10
    • /
    • pp.17-23
    • /
    • 2003
  • In this study, microscale, high-performance, solenoid-type RF chip inductors were investigated. The size of the RF chip inductors fabricated in this work was 1.0${\times}$0.5${\times}$0.5㎣. The materials (96% Al2O3) and shape (I-type) of the core were determined by a Maxwell three-dimensional field simulator to maximize the performance of the inductors. The copper (Cu) wire with 40${\mu}{\textrm}{m}$ diameter was used as the coils. High frequency characteristics of the inductance (L), quality-factor (Q), and capacitance (C) of developed inductors were measured using an RF Impedance/Material Analyzer (HP4291B with HP16193A test fixture). The inductors developed have inductances of 11 to 39 nH and quality factors of 28 to 50 over the frequency ranges of 250MHz to 1 GHz, and show results comparable to those measured for the inductors prepared by CoilCraf $t^{Tm}$ that is one of the best chip inductor company in the world. The simulated data predicted the high-frequency data of the L, Q, and C of the inductors developed well.l.

A Retrospective Clinical Study of Survival Rate for a Single Implant in Posterior Teeth (구치부 단일 임플란트의 생존율에 대한 후향적 연구)

  • Han, Sung-Il;Lee, Jae-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.3
    • /
    • pp.186-199
    • /
    • 2012
  • Purpose: Single implants, of which screw loosening has been observed frequently, presents problems such as fixtures fractures, marginal bone loss, and inflammation of the soft tissue around the implant. However, the single implant is more conservative, cost effective, and predictable compared to the 3 unit bridge with respect to the long-term outcome. This study evaluated the survival rate as well as future methods aimed at increasing the survival rate in single implants in posterior teeth. Methods: Among the implants placed in the Dankook University Dental Hospital department of Oral & Maxillofacial surgery from January 2001 to June 2008, 599 implants placed in the maxillar and mandibular posterior were evaluated retrospectively. Survival rates were investigated according to implant location, cause of tooth loss, gender, age, general disease, fixture diameter and length, surface texture, implant type and shape, presence of bone graft, surgery stage, surgeons, bone quality and opposite teeth. Results: Out of 599 single implants in posterior teeth, 580 implants survived and the survival rate was 96.8%. The difference in survival rate was statistically significant according to the implant location. The survival rate was low (84.2%) in implants exhibiting a wide diameter (${\geq}5.1mm$) and the surface treated by the acid etching group demonstrated a significantly lower survival rate (91.1%). One stage surgical procedure, which implemented a relatively better bone quality survival rate (100%), was higher than the two stage surgical procedure (96.1%). The survival rate of type IV bone quality (75%) was significantly lower than the other bone quality. Conclusion: Single posterior teeth implant treatments should use an improved surface finishing fixture as well as careful and safe procedures when performing implant surgery in the maxilla premolar and molar regions since bone quality is poor.

Clinical accuracy of impression technique using digital superimposition of customized abutment with subgingival margin: A case report (치은연하 변연을 가지는 맞춤형 지대주에서 디지털 중첩기술을 이용한 인상채득술의 임상 적용 증례)

  • Kim, Jin-Wan;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Lee, Hyeonjong;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.2
    • /
    • pp.169-175
    • /
    • 2020
  • Traditionally, gingival retraction has been performed to obtain customized abutment impressions with subgingival margins of the implant supported prosthesis. However, gingival retraction may have side effects such as gingival recession and bleed, leading to an inaccurate impression. In order to prevent these problems, in this case, the new technique has been introduced; a customized abutment which is designed for superimposition is used. Before the connection of the abutment to the implant fixture, pre-scanned shape data are stored, and then the optical impression without gingival retraction is obtained after connecting to the fixture. The suprastructure is fabricated by superimposing the two data. This technique showed the clinical efficacy of fabricating the implant supported prosthesis with subgingival margin, which satisfied the aesthetics, convenience, and clinically acceptable marginal and internal fit.

Development of a Dedicated CAM System for Human Bust Machining (흉상 환조 가공을 위한 전용 CAM시스템 개발)

  • Jeong, Hoi-Min;Park, Joon-Chul;Chung, Yun-Chan
    • IE interfaces
    • /
    • v.15 no.2
    • /
    • pp.147-151
    • /
    • 2002
  • Presented in this paper is a prototype of dedicated CAM system for a human bust, not a relief, machining. The input of this system is a STL file which comes from measuring machine, and the output is machining data for a 3-axis CNC milling machine with an index table. The system consists of three main modules, which are shape import and transformation, modeling of jig and fixture, and calculation of machining area. Proposed system architecture and the main modules are briefly described. To get machining region for semi-finish and finish machining stages, two concepts of machining area, machinable and scannable, were tried. Machinable area was suitable for the purpose.

Integration of a micro lens on a in-plane positioning actuator with 2-DOF (마이크로 렌즈가 집적된 2-자유도 평면구동기의 설계 및 제작)

  • Kim, Che-Heung;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3322-3324
    • /
    • 1999
  • This paper studies on the design and fabrication of a micro in-plane positioning actuator integrated with a microlens. Proposed in-plane actuator is a micro XY-stage which is composed of two linear comb drive actuators being orthogonal to each other. In the fabrication of actuator, the single crystalline silicon substrate anodically bonded with a #7740 glass substrate is used because of simple release and passivation. The structure of actuator is formed on the silicon facet of bonded fixture by chlorine-based deep RIE and then released by isotropic wet etching of glass (#7740) in hydrofluoric acid solution. Fabricated actuator has a large travel range up to $30({\pm}15){\mu}m$ and high resolution less than 0.01f1l1l in each direction. Experimented resonant frequency of this actuator is 630Hz. The micro-Fresnel lens is fabricated on the square-shape glass structure prepared in the center of actuator.

  • PDF

Shape memory alloy (SMA)-based head and neck immobilizer for radiotherapy

  • Lee, Hyun-Taek;Kim, Sung-In;Park, Jong Min;Kim, Ho-Jin;Song, Dae-Seob;Kim, Hyung-Il;Wu, Hong-Gyun;Ahn, Sung-Hoon
    • Journal of Computational Design and Engineering
    • /
    • v.2 no.3
    • /
    • pp.176-182
    • /
    • 2015
  • Head-and-neck cancer is often treated with intensive irradiation focused on the tumor, while delivering the minimum amount of irradiation to normal cells. Since a course of radiotherapy can take 5-6 weeks or more, the repeatability of the patient posture and the fastening method during treatment are important determinants of the success of radiotherapy. Many devices have been developed to minimize positional discrepancies, but all of the commercial devices used in clinical practice are operated manually and require customized fixtures for each patient. This is inefficient and the performance of the fixture device depends on the operator's skill. Therefore, this study developed an automated head-and-neck immobilizer that can be used during radiotherapy and evaluated the positioning reproducibility in a phantom experiment. To eliminate interference caused by the magnetic field from computed tomography hardware, Ni-Ti shape-memory alloy wires were used as the actuating elements of the fixtures. The resulting positional discrepancy was less than 5 mm for all positions, which is acceptable for radiotherapy.

The effect of implant shape and bone preparation on primary stability

  • Moon, Sang-Hyun;Um, Heung-Sik;Lee, Jae-Kwan;Chang, Beom-Seok;Lee, Min-Ku
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.5
    • /
    • pp.239-243
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the effects of implant shape and bone preparation on the primary stability of the implants using resonance frequency analysis. Methods: Sixty bovine rib blocks were used for soft and hard bone models. Each rib block received two types of dental implant fixtures; a straight-screw type and tapered-screw type. Final drilling was done at three different depths for each implant type; 1 mm under-preparation, standard preparation, and 1 mm over-preparation. Immediately after fixture insertion, the implant stability quotient (ISQ) was measured for each implant. Results: Regardless of the bone type, the ISQ values of the straight-screw type and tapered-screw type implants were not significantly different (P>0.05). Depth of bone preparation had no significant effect on the ISQ value of straight-screw type implants (P>0.05). For the tapered-screw type implants, under-preparation significantly increased the ISQ value (P<0.05), whereas overpreparation significantly decreased the ISQ value (P<0.05). Conclusions: Within the limitations of this study, it is concluded that bone density seemed to have a prevailing effect over implant shape on primary stability. The primary stability of the tapered-screw type implants might be enhanced by delicate surgical techniques.