• 제목/요약/키워드: Fixture diameter

검색결과 91건 처리시간 0.031초

$\cdot$하악 대구치 부위에 식립된 임플란트의 생존율에 대한 후향적 연구 (Survival analysis of dental implants in maxillary and mandibular molar regions; A 4$\sim$5 year report)

  • 장진화;류경호;정현주
    • Journal of Periodontal and Implant Science
    • /
    • 제37권2호
    • /
    • pp.165-180
    • /
    • 2007
  • Dental Implants have been proved to be successful prosthetic modality in edentulous patients for 10 years. However, there are few reports on the survival of implant according to location in molar regions. The purpose of this study was to evaluate the $4{\sim}5$ years' cumulative survival rate and the cause of failure of dental implants in different locations for maxillary and mandibular molars. Among the implants placed in molar regions in Gwangju Mir Dental Hospital from Jan. 2001 to Jun. 2002, 473 implants from 166 patients(age range; $26{\sim}75$) were followed and evaluated retrospectively for the causes of failure. We included 417 implants in 126 periodontally compromised patients, 56 implants in 40 periodontal healthy patients, and 205 maxillary and 268 mandibular molar implants. Implant survival rates by various subject factors, surgical factors, fixture factors, and prosthetic factors at each location were compared using Chi-square test and Kaplan-Meier cumulative survival analysis was done for follow-up(FU) periods. The overall failure rate at 5 years was 1O.2%(subject level) and 5.5%(implant level). The overall survival rates of implants during the FU periods were 94.5% with 91.3% in maxillary first molar, 91.1% in maxillary second molar, 99.2% in mandibular first molar and 94,8% in mandibular second molar regions. The survival rates differed significantly between both jaws and among different implant locations(p<0.05), whereas the survival rates of functionally loaded implants were similar in different locations. The survival rates were not different according to gender, age, previous periodontal status, surgery stage, bone graft type, or the prosthetic type. The overall survival rate was low in dental implant of too wide diameter(${\geq}5.75$ mm) and the survival rate was significantly lower for wider implant diameter(p

굽힘상태의 외부보강한 Bi-2223 초전도테이프에서 임계전류 열화특성에 미치는 인장변형률의 영향 (Effect of Tensile Strain on $I_c$ Degradation Characteristics In Bent Externally Reinforced Bi-2223 Superconducting Tapes)

  • 신형섭;김기현;오상수;하동우
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권1호
    • /
    • pp.6-11
    • /
    • 2004
  • The influences of mixed strain mode of bending-tension on the critical current. Ic in externally reinforced Bi-2223 tapes and their interaction were investigated in this study. A test fixture which providing a mixed deformation mode of bending-tension to HTS tapes has been newly devised. When the total strain induced in the tape in the mixed strain mode was expressed by the superposition of the bending and tensile strains the irreversible strain for the critical current degradation of Bi-2223 tapes increased, as compared with the simple bending mode case. The $I_c$ degradation at the region exceeding the irreversible strain showed a medium between the simple bending case and the simple tension case. As the initial bending strain imparted increased , namely as the diameter of mandrel adopted decreased. the apparent irreversible strain in Bi-2223 tapes increased . but the increment became smaller As a result. it can be found that the tension to be applied to bent Bi-2223 tapes during cabling should be smaller. as the mandrel diameter becomes smaller.

구배가 없는 신배수시스템의 제안 및 배수유동 특성에 관한 실험적 연구 (The Proposal of a New Drainage System without Incline of Piping and Experiment on Drainage Flow Characteristics)

  • 차영호;이정재
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.452-458
    • /
    • 2005
  • In Korea, pumping pipe using gravity way by water is most popular method in drainage system. But, it is difficult to repair a drainpipe in this method because the drain pipe diameter is increased as using this method. In this research, we propose a new drainage system. The system aim for an adaptedness with buildings, freedom of plan, construction and renewal in water pipe equipments, etc. The new system is not need of incline of piping, and it uses drainage power that is changed potential energy by high velocity flow as making Siphonage at vertical pipe. Therefore, the diameter of piping can decreased than existing piping system established in the ceiling. Also because connecting position will be located at the lower part, it is changed the potential energy of drainage to the high velocity flow. In addition, drainage will be smooth because the fixture drain is linked by each drain pipes.

심미적인 상악 전치부 임플란트 보철물 만들기 (Esthetic Implant Prostheses for Anterior Teeth)

  • 김기성
    • 대한치과의사협회지
    • /
    • 제56권9호
    • /
    • pp.492-502
    • /
    • 2018
  • Anterior maxillary teeth play an important role in determining a person's first impression and facial profile. Implant surgery in esthetic area requires more careful diagnosis, treatment planning, surgery, and prosthetic restoration than in posterior area. To avoid complications in surgery and prosthetic restoration for implants in esthetic area, accurate diagnosis and appropriate case selection become very important. If you have decided to restore the area with implant prosthesis, you have to know exactly where to place an implant. I will discuss the ideal implant position in terms of mesio-distally, apico-coronally, labio-palatally, and implant angulation. And I would like to point out the selection of fixture diameter & length for anterior implant. Finally, a clinical implant prosthesis case in maxillary central incisor will be shown. In conclusion, for superior esthetic outcome in anterior implant prostheses, we must understand the patient's anatomic condition and know our ability.

  • PDF

무선통신시스템을 위한 극소형 RF 칩 인덕터의 개발 (Development of Microscale RF Chip Inductors for Wireless Communication Systems)

  • 윤의중;김재욱;정영창;홍철호
    • 대한전자공학회논문지SD
    • /
    • 제40권10호
    • /
    • pp.17-23
    • /
    • 2003
  • 본 논문에서는 고성능의 극소형, 솔레노이드 형태의 RF 칩 인덕터를 연구하였다. 제작된 RF 칩 인덕터의 크기는 1.0×0.5×0.5㎣ 이었다. 코아의 재료 (96% Al₂O₃)와 모양 (I-type)은 인덕터의 성능을 극대화시키도록 Maxwell three-dimensional field simulator를 이용하여 결정되었다. 40㎛의 직경을 가진 가는 구리(Cu)도선을 코일로 사용하였다. 개발된 인덕터의 인덕턴스 (L), 품질계수 (Q), 그리고 커패시턴스 (C) 들에 대한 고주파 특성은 RF 임피던스/재료 분석기 (HP16193A 시험 fixture가 장착된 HP4291B)를 사용하여 측정되었다. 개발된 인덕터들은 230MHz - 1 GHz의 주파수 영역에서 11 - 39 nH 범위의 인덕턴스 값과 28 - 50 범위의 품질계수 값을 가지는데 이는 전 세계적으로 가장 좋은 칩 인덕터 업체 중의 하나인 CoilCraft/sup Tm/에 의해 생산된 인덕터들의 특성과 유사한 결과를 나타내고 있다. 시뮬레이션 데이터는 개발된 인덕터의 L, Q, C 등의 고주파 특성을 잘 예측하고 있다.

Influence of the connection design and titanium grades of the implant complex on resistance under static loading

  • Park, Su-Jung;Lee, Suk-Won;Leesungbok, Richard;Ahn, Su-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권5호
    • /
    • pp.388-395
    • /
    • 2016
  • PURPOSE. The purpose of this study was to evaluate the resistance to deformation under static overloading by measuring yield and fracture strength, and to analyze the failure characteristics of implant assemblies made of different titanium grades and connections. MATERIALS AND METHODS. Six groups of implant assemblies were fabricated according to ISO 14801 (n=10). These consisted of the combinations of 3 platform connections (external, internal, and morse tapered) and 2 materials (titanium grade 2 and titanium grade 4). Yield strength and fracture strength were evaluated with a computer-controlled Universal Testing Machine, and failed implant assemblies were classified and analyzed by optical microscopy. The data were analyzed using the One-way analysis of variance (ANOVA) and Student's t-test with the level of significance at P=.05. RESULTS. The group $IT4_S$ had the significantly highest values and group IT2 the lowest, for both yield strength and fracture strength. Groups $IT4_N$ and ET4 had similar yield and fracture strengths despite having different connection designs. Group MT2 and group IT2 had significant differences in yield and fracture strength although they were made by the same material as titanium grade 2. The implant system of the similar fixture-abutment interfaces and the same materials showed the similar characteristics of deformation. CONCLUSION. A longer internal connection and titanium grade 4 of the implant system is advantageous for static overloading condition. However, it is not only the connection design that affects the stability. The strength of the titanium grade as material is also important since it affects the implant stability. When using the implant system made of titanium grade 2, a larger diameter fixture should be selected in order to provide enough strength to withstand overloading.

Solenoid 형태의 초소형 SMD RF 칩 인덕터에 대한 주파수 특성 (Frequency Characteristics for Micro-scale SMD RE Chip Inductors of Solenoid-Type)

  • 김재욱
    • 한국산학기술학회논문지
    • /
    • 제8권3호
    • /
    • pp.454-459
    • /
    • 2007
  • 본 논문에서는 비정질 $Al_2O_3$ 코아 재료를 응용한 단순 solenoid 형태의 소형 고성능 RF 칩 인덕터를 연구하였다. 인덕터 크기는 $0.86{\times}0.46{\times}0.45mm^3$이고, $27{\mu}m$ 직경의 Cu를 코일로 사용하였다. RF 칩 인덕터의 인덕턴스(L), 양호 인자(Q), 임피던스(Z), 커패시턴스(C)와 등가회로 파라미터 등의 주파수 특성은 RF impedance/Material Analyzer (HP16193A test fixture가 장착된 HP4291B)로 측정되었다. $9{\sim}12$회의 권선수를 가진 RF 칩 인덕터들의 인덕턴스 값은 $21{\sim}34nH$ 범위를 가진다. 이들의 자기공진주파수(SRF)는 $5.7{\sim}3.7GHz$ 영역을 나타낸다. 또한 자기공진주파수가 증가함에 따라 인덕턴스 값이 감소하는 경향을 보이고 있다. 인덕터의 SRF는 인덕턴스가 증가함에 따라 감소하며, Q의 값은 $900MHz{\sim}1.7GHz$ 주파수 범위에서 최대 $38{\sim}49$까지 얻어졌다.

  • PDF

골유착 재현 레진 모델에서 골 상태 및 임플란트 형태에 따른 임플란트 안정성에 관한 연구 (Implant stability evaluation according to the bone condition, fixture diameter and shape in the osseointegration simulated resin model)

  • 권택가;여인성;김성훈;한중석;이재봉;양재호
    • 대한치과보철학회지
    • /
    • 제49권2호
    • /
    • pp.128-137
    • /
    • 2011
  • 연구 목적: 자기공명주파수 분석, 페리오테스트, 풀림 토크는 임플란트의 안정성을 측정하기 위한 방법으로 알려져 있다. 이 방법들은 골 상태와 임플란트 형태에 영향을 받는다. 본 연구에서는 골유착이 재현된 아크릴 레진 실험 모델에서 임플란트가 결합된 골의 양을 변화하고 경부의 골 상실양이 증가하였을 경우, 자기공명주파수 분석, 페리오테스트, 풀림 토크 측정에 어떠한 영향을 주는지 알아보고 이들 상호간의 관계를 알아보고자 하였다. 연구 재료 및 방법: 골 유착을 재현하기 위하여 임플란트를 알루미늄 틀에 나사로 고정한 후 자가중합형 아크릴릭 레진의 가루와 용액을 틀 안에 부어서 중합을 시켰다. 임플란트와 결합된 레진의 두께를 조정하여 골 결합 두께를 각각 1, 3, 5, 10 mm인 경우로 재현하였다. 그 후 임플란트 주변 경부 골 상실 양이 1, 3, 5 mm인 경우를 재현하였다. 각각의 재현된 골 조건에서는 4 mm 직경의 직선형 임플란트, 같은 직경의 tapered 형 임플란트, 5 mm 직경의 tapered 형의 3가지 임플란트가 각각 5개씩 사용되었다. 모든 골 조건에서 자기공명주파수 분석과 페리오테스트 측정이 이루어졌으며 골 결합 두께 1, 3 mm 시편에서는 풀림 토크가 측정되었다. 결과: 골 결합 두께가 증가하거나 임플란트 직경이 증가할수록 통계적으로 유의하게 ISQ 값은 증가하였고, 페리오테스트 값은 감소하였다 (P<.001, P<.001). 임플란트 경부에 주위 골 상실 양이 커질수록 ISQ 값은 감소하였고, 페리오테스트 값은 증가하였다 (P<.001). ISQ 값과 페리오테스트 t값은 매우 강한 상관관계를 나타냈다 (r = -0.99, P<.001). ISQ값과 풀림토크는 약한 상관관계를 나타냈으며 (r = 0.52, P<.001), 페리오테스트 값과 풀림 토크도 약한 상관관계를 나타냈다 (r = -0.52, P<.001). 결론: 레진으로 재현한 골의 양이 증가할수록, 임플란트의 직경이 증가할수록, 경부의 골 상실양이 적을수록 임플란트 안정성이 증가함을 확인할 수 있었다. 또한 본 연구에서는 ISQ 값과 페리오테스트 값의 강한 상관관계를 밝힐 수 있었다.

백서에 식립한 치과용 임플란트의 골유착에 흡연이 미치는 영향 (INFLUENCE OF CIGARETTE SMOKE INHALATION ON DENTAL IMPLANT OSSEOINTEGRATION IN THE RAT)

  • 김세호;김성민;김지혁;박영욱;박찬진;정기명;이석근
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제31권4호
    • /
    • pp.291-299
    • /
    • 2005
  • Objectives : It is well known that cigarette smoking is harzardous to the osseointegration of dental implant, due to the impaired wound healing accompanied by reduced alveolar bone density. The aim of this study is to evaluate the influence of cigarette smoke on the implant osseointegration by the time factor consideration. Materials and methods : Twenty-four male Spraque-Dawley rats (8 weeks, weighting 200 to 250g) were used in this study. In the experimental group, 13 rats were exposed to cigarette smoke, 8 minutes per day during 6 weeks, and 12 rats in the control group were not exposed at any time. RBM (Resorbed blasting media) surfaced implant (diameter 3.3mm, length 5.0mm, AVANA Co., Korea) was placed in the right femur of each rat. Each implant with surrounding bone was prepared with microtome (cutting band 0.2mm$^{(R)}$, EXAKT Co., Germany) after 1 day, 2, 4, 8 and 12 weeks and stained with toluidine blue (1%). Another clinical investigation of each implant was also done at each evaluation time. Results : Clinical investigation around implant fixture showed that there were no significant differences between the control and experimental group. Microscopic observation around implant fixture showed that there were significant differences between the control and experimental group at the initial stage after implant fixture installation. Experimental group showed a decreased bone to implant contact within 4 weeks compared to control group, but showed similar characteristics after 4 weeks. Conclusion : Smoking inhalation effect on the dental implant showed the impaired wound healing by vasoconstriction and decreased intramedullary blood flow at initial stage of osseointegration. This experimental results can be clinically useful to the implant surgery of smoking patients.

Micro thread를 포함한 GSII RBM임플란트(Osstem)의 후향적 임상연구 (Retrospective Study of GS II Implant(Osstem) with an Internal Connection with Microthreads)

  • 지영덕;이재환;오상천
    • 구강회복응용과학지
    • /
    • 제25권4호
    • /
    • pp.417-429
    • /
    • 2009
  • 골유착성 임플란트가 소개된 이후로 부분 및 무치악 부위에서 사용되어 높은 성공률과 함께 예지성 있는 결과를 보여주는 치료방법으로 인정받고 있다. 그러나 국내에서 개발된 임플란트에 대해서는 임상적이고 객관적인 연구 자료가 불충분하다. 본 연구에서는 31명의 환자에게서 임플란트 경부에 미세나사를 지닌 임플란트 식립 후 평균 21개월의 기간 동안 임플란트의 생존율에 관한 조사를 시행하였고 부하가 가해지는 시점을 기준으로 12개월 간 변연골의 변화를 파노라마사진을 이용하여 측정 관찰하여 다음의 결과를 도출하였다. 총 96개의 임플란트에서 3개의 임플란트가 실패하여 96.9%의 생존율을 보였다. 50대 환자에서 85.7%로 가장 작은 생존율을 보였으며 성별 및 연령에 따른 생존율 및 변연골 흡수량에 대한 통계적 유의성은 존재하지 않았다. 상악에서는 95.7% 하악에서는 100%의 생존율을 보였다. 골이식 여부, 보철물의 종류, 매식체의 길이 및 직경에 따른 생존율의 차이는 통계적으로 유의한 차이를 보이지 않았다. 기능 부하 후 임플란트 변연골 흡수량은 단일 금관 보철물이 연결 고정 보철물에 비해 증가된 양상을 보였으나 임플란트의 직경, 길이, 골이식의 유무, 식립위치에 의해서는 통계적으로 유의한 차이를 보이지 않았다. 이 연구를 통해 경부에 미세나사를 지닌 임플란트 식립 후에 임플란트 변연골 흡수량은 비교적 적게 일어났으며 또한 안정적으로 유지되는 것이 관찰될 수 있었고 이에 따른 장기적인 추적관찰이 필요할 것으로 사료된다.