• 제목/요약/키워드: Fixture

검색결과 723건 처리시간 0.023초

감소된 치조골 고경을 갖는 치아와 골유착성 임프랜트에 의해 지지되는 고정성 국소의치의 유한요소법적 응력분석 (A FINITE ELEMENT STRESS ANALYSIS OF FIXED PARTIAL DENTURE SUPPORTED BY OSSEOINTEGRATED IMPLANT AND THE NATURAL TEETH WITH REDUCED ALVEOLAR BONE HEIGHT)

  • 최충국;계기성;조규종
    • 대한치과보철학회지
    • /
    • 제32권2호
    • /
    • pp.296-326
    • /
    • 1994
  • The purpose of this study was to evaluate the mechanical effects when one implant fixture was connected to the natural teeth with reduced alveolar bone height. This study also examined the effects of increasing the number of abutment teeth and the effects of the intramobile connector and the titanium connector as they were inserted between the implant superstructure and the fixture. The distribution and concentration load was applied to the fixed partial denture(FPD) supported by implant and the natural teeth with reduced alveolar bone height. The stress and displacement of each element was observed and compared by the two-dimensional finite element method. The following results were obtained : 1. The greater the loss of alveolar bone in natural teeth area, the greater the displacement of FPD and the stress concentration in alveolar bone around implant, especially at the stress concentration in the mesial alveolar bone crest around implant fixture. 2. The displacement of FPD was increased more and that of implants fixture was decreased more when intramobile connector was used than titanium connector was used. Also the stress concentration in alveolar bone around implant fixture was greater when intramobile connector than titanium connector. One implication of this finding was that the difference in stiffness of implant and the natural teeth with reduced alveolar bone height could be partially compensated in case of the POM intramobile connector. 3. The amount and direction of displacement and the stress distribution of the 4-unit FPD was better than those of the 3-unit FPD. It implied that the difference of stiffness of implant and natural teeth with reduced alveolar bone height could be partially compensated in case of the 4 unit FPD.

  • PDF

3차원 유한요소법적 분석을 이용한 5종의첨형 임플랜트에 발생하는 응력의 비교연구 (THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF FIVE DIFFERENT TAPER DESIGN IMPLANT SYSTEMS)

  • 변상기;박원희;이영수
    • 대한치과보철학회지
    • /
    • 제44권5호
    • /
    • pp.584-593
    • /
    • 2006
  • Statement of problem : Dental implant which has been developed gradually through many experiments and clinical applications is presently used to various dental prosthetic treatments. To conduct a successful function of implant prosthesis in oral cavity for a long time, it is important that not only structure materials must have the biocompatibility, but also the prosthesis must be designed for the stress, which is occurred in occlusion, to scatter adequately of load support. Therefore, it is essential to give the consideration about the stress analysis of supporting tissues for higher successful rates. Purpose : Recently, many implant manufacturing company produce various taper design of root form implant, the fixture is often selected. However, the stress analysis of taper form fixture still requires more studies. Material and method : This study we make the element models that five implant fixture; Branemark system(Nobel Biocare, Gothenberg, Sweden), Camlog system(Altatec, Germany), Astra system(Astra Tech, Sweden), 3i system(Implant Innovations Inc, USA), Avana system(Osstem, Korea) were placed in the area of mandibular first premolar and prosthesis fabricated, which we compared with stress distribution using the three-dimension finite element analysis under two loading condition. Results : This study compares the aspect of stress distribution of each system with the standard of Von mises stress, among many resulted from finite element analysis so that this research gets the following results. 1. In all implant system, oblique loading of maximum Von mises stress of implant, alveolar bone and crown is higher than vertical loading of those. 2. Regardless of loading conditions and type of system, cortical bone which contacts with implant fixture top area has high stress, and cancellous bone has a little stress. under the vertical loading, maximum Von mises stress is more higher in order of Branemark, Camlog, Astra, 3i, Avana. under the horizontal loading, maximum Von mises is more higher in order of Camlog, Branemark, Astra, 3i, Avana.

정밀 연삭된 지대주와 합성수지 지대주를 이용한 보철물의 적합도에 대한 비교 연구 (A COMPARATIVE STUDY ON THE FIT IN PROSTHESIS USING PREMADE GOLD CYLINDER AND PLASTIC CYLINDER)

  • 정선희;마장선;정재헌
    • 대한치과보철학회지
    • /
    • 제37권6호
    • /
    • pp.825-834
    • /
    • 1999
  • Recently, various implant cylinders were supplied. especially received gold cylinders, cast cylinders produced from premade gold and plastic cylinders and plastic cylinders. This study measured and compared precise fit produced when using conventional gold and plastic cylinders. The comparative fit of lapped and non-lapped castings made from plastic pattern was examined. The implant/abutment interface fit was evaluated by scanning electron microscopy(SEM) for each of four cylinders. The following results were obtained: 1. The case of plastic cylinder showed $9.67{\pm}1.50{\mu}m$ gap when Steri-Oss fixture was connected. 2. The case of lapped casting made from plastic cylinder showed $3.01{\pm}2.81{\mu}m$ gap when Steri-Oss fixture was connected. 3 The case of gold/plastic cylinder showed $9.80{\pm}1.68{\mu}m$ gap when Steri-Oss fixture was connected. 4. The case of gold cylinder showed ${5.47{\pm}2.43\mu}m$ gap when Steri-Oss fixture was connected. 5. In case of each cylinder which was connected with Steri-Oss fixture, the size of gap was showed less in the order of the case of gold/plastic cylinder, the case of plastic cylinder, the case of gold cylinder and the case of lapped casting made from plastic cylinder As results of this study, the use of premade gold cylinder offers an advantage over plastic pat-terns in precise fit. When plastic patterns are used, polishing of implant cylinder components should provide precise fit.

  • PDF

A comparative study of gold UCLA-type and CAD/CAM titanium implant abutments

  • Park, Ji-Man;Lee, Jai-Bong;Heo, Seong-Joo;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권1호
    • /
    • pp.46-52
    • /
    • 2014
  • PURPOSE. The aim of this study was to evaluate the interface accuracy of computer-assisted designed and manufactured (CAD/CAM) titanium abutments and implant fixture compared to gold-cast UCLA abutments. MATERIALS AND METHODS. An external connection implant system (Mark III, n=10) and an internal connection implant system (Replace Select, n=10) were used, 5 of each group were connected to milled titanium abutment and the rest were connected to the gold-cast UCLA abutments. The implant fixture and abutment were tightened to torque of 35 Ncm using a digital torque gauge, and initial detorque values were measured 10 minutes after tightening. To mimic the mastication, a cyclic loading was applied at 14 Hz for one million cycles, with the stress amplitude range being within 0 N to 100 N. After the cyclic loading, detorque values were measured again. The fixture-abutment gaps were measured under a microscope and recorded with an accuracy of ${\pm}0.1{\mu}m$ at 50 points. RESULTS. Initial detorque values of milled abutment were significantly higher than those of cast abutment (P<.05). Detorque values after one million dynamic cyclic loadings were not significantly different (P>.05). After cyclic loading, detorque values of cast abutment increased, but those of milled abutment decreased (P<.05). There was no significant difference of gap dimension between the milled abutment group and the cast abutment group after cyclic loading. CONCLUSION. In conclusion, CAD/CAM milled titanium abutment can be fabricated with sufficient accuracy to permit screw joint stability between abutment and fixture comparable to that of the traditional gold cast UCLA abutment.

경사하중에 따른 시멘트 유지형 임플란트 지지골의 유한요소법 응력 분포 (Finite Element Analysis of Stress Distribution on Supporting Bone of Cement Retained Implant by Oblique Loading)

  • 이명곤
    • 한국콘텐츠학회논문지
    • /
    • 제14권9호
    • /
    • pp.343-349
    • /
    • 2014
  • 본 연구는 치과 임상에서 사용하고 있는 시멘트 유지형 치과용 임플란트의 지지골 응력 분포 안정성을 확인하고자 시행하였다. 모델링과 유한요소 응력 분석은 유한요소 해석 프로그램인 Solidworks를 사용하였고, 시멘트 유지형 임플란트 시스템인 지대주와 고정체를 연결하는 지대주 나사를 20 Ncm 나사조임력에 의한 결합조건을 적용시킨 단관 모델을 제작하고, 설측에서 협측으로의 $45^{\circ}$ 경사로 100 N 크기 외부하중을 가하여 지지골 응력 분포 해석을 실시하였다. 경사하중에 따른 임플란트 고정체의 지지골 응력 크기와 분포를 파악하기 위한 유한요소법 분석을 통해 다음 결과를 얻었다. 고정체 직경, 길이의 조건에 관계없이 임플란트 고정체 상부와 골 접촉부인 치밀골에 응력이 집중되는 양상으로 나타났고, 고정체 길이 증가로 인한 응력 감소 폭보다 직경 증가로 인한 감소폭이 큰 것으로 나타났다 따라서 본 연구 결과는 지지골 형태 조건에 대하여 가능한 큰 직경의 고정체 사용이 효과적이라고 판단된다.

Sinking and fit of abutment of locking taper implant system

  • Moon, Seung-Jin;Kim, Hee-Jung;Son, Mee-Kyoung;Chung, Chae-Heon
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권2호
    • /
    • pp.97-101
    • /
    • 2009
  • STATEMENT OF PROBLEM. Unlike screw-retention type, fixture-abutment retention in Locking taper connection depends on frictional force so it has possibility of abutment to sink. PURPOSE. In this study, Bicon$^{(R)}$ Implant System, one of the conical internal connection implant system, was used with applying loading force to the abutments connected to the fixture. Then the amount of sinking was measured. MATERIAL AND METHODS. 10 Bicon$^{(R)}$ implant fixtures were used. First, the abutment was connected to the fixture with finger force. Then it was tapped with a mallet for 3 times and loads of 20 kg corresponding to masticatory force using loading application instrument were applied successively. The abutment state, slightly connected to the fixture without pressure was considered as a reference length, and every new abutment length was measured after each load's step was added. The amount of abutment sinking (mm) was gained by subtracting the length of abutment-fixture under each loading condition from reference length. RESULTS. It was evident, that the amount of abutment sinking in Bicon$^{(R)}$ Implant System increased as loads were added. When loads of 20 kg were applied more than 5 - 7 times, sinking stopped at $0.45{\pm}0.09\;mm$. CONCLUSION. Even though locking taper connection type implant shows good adaption to occlusal force, it has potential for abutment sinking as loads are given. When locking taper connection type implant is used, satisfactory loads are recommended for precise abutment location.

임플란트 매식 시 수직골 높이에 따른 응력분석 (Stress analysis according to the vertical bone level in the implant placement)

  • 김민호;박영록;계기성
    • 구강회복응용과학지
    • /
    • 제18권4호
    • /
    • pp.301-311
    • /
    • 2002
  • The purpose of this study was to compare the distributing pattern of stress on the finite element models with the different vertical bone level of implant fixture. The two kinds of finite element models were designed according to vertical bone level around fixture ($4.0mm{\times}11.5mm$). The cemented crowns for mandibular first and second molars were made. Three- dimensional finite element model was created with the components of the implant and surrounding bone. Vertical loads were applied with force of 200N distributed within 0.5mm radius circle from the center of central fossa and distance 2mm and 4 mm apart from the center of central fossa. Von-Mises stresses were recorded and compared in the supporting bone, fixtures, abutment screws, and crown. The results were as following : (1) In vertical loading at the center circle of central fossa on model 1 and 2, the difference from vertical bone in implant placement did not affect the stress pattern on all components of implant except for crown. (2) With offset distance incerasing and the bone level of implant decreasing, the concentration of stress occured in the buccal side of long crown, around the buccal crestal bone, and on the fixture- abutment interface. As a conclusion, the research showed a tendency to increase the stress on the supporting bone, fixture and screw under the offset loads when the vertical level of bone around fixture was different. Since the same vertical bone bed has more benefits than the different bone bed around fixtures, it is important to prepare a same vertical level of bone bed for the success of implants under occlusal loads.

Energy-dispersive X-ray spectroscopic investigation of a fractured non-submerged dental implant associated with abutment fracture

  • Truc Thi Hoang Nguyen;Mi Young Eo;Kezia Rachellea Mustakim;Mi Hyun Seo;Hoon Myoung;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제49권1호
    • /
    • pp.43-48
    • /
    • 2023
  • The biocompatibility and durability of implant fixtures are major concerns for dentists and patients. Mechanical complications of the implant include abutment screw loosening, screw fracture, loss of implant prostheses, and implant fracture. This case report aims to describe management of a case of fixture damage that occurred after screw fracture in a tissue level, internal connection implant and microscopic evaluation of the fractured fixture. A trephine bur was used to remove the fixture, and the socket was grafted using allogeneic bone material. The failed implant was examined by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS), which revealed a fractured fixture with both normal and irregular bone patterns. The SEM and EDS results give an enlightenment of the failed fixture surface micromorphology with microfracture and contaminated chemical compositions. Noticeably, the significantly high level of gold (Au) on the implant surface and the trace amounts of Au and titanium (Ti) in the bone tissue were recorded, which might have resulted from instability and micro-movement of the implant-abutment connection over an extended period of time. Further study with larger number of patient and different types of implants is needed for further conclusion.

지대주의 반복적인 착탈에 따른 임플랜트 고정체의 external hexagon과 지대주 internal hexagon의 변화에 관한 연구 (SURFACE CHANCE OF EXTERNAL HEXAGON OF IMPLANT FIXTURE AND INTERNAL HEXAGON OF ABUTMENT AFTER REPEATED DELIVERY AND REMOVAL OF ABUTMENT)

  • 정석원;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.528-543
    • /
    • 2005
  • Statement of problem: Repeated delivery and removal of abutment cause some changes such as wear, scratch or defect of hexagonal structure. It may increase the value of rotational freedom(RF) between hexagonal structures. Purpose: The purpose of this study was to evaluate surface changes and rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment after repeated delivery and removal under SEM and toolmaker's microscope. Materials and methods: Implant systems used for this study were 3i and Avana. Seven pail's of implant fixture, abutment and abutment screws for each system were selected and all fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. Each one was embedded beneath the platform of fixture. Surfaces of hexagonal structure before repeated closing and opening of abutment were observed using SEM and rotational freedom was measured by using toolmaker's microscope. Each abutment was secured to the implant future by each abutment screw with recommended torque value using a digital torque controller and was repeatedly delivered and removed by 20 times respectively. After experiment, evaluation for the change of hexagonal structures and measurement of rotational freedom were performed. Result : The results were as follows; 1. Wear of contact area between implant fixture and abutment was considerable in both 3i and Avana system. Scratches and defects were frequently observed at the line-angle of hexagonal structures of implant fixture and abutment. 2. In the SEM view of the external hexagon of implant fixture, the point-angle areas at the corner edge of hexagon were severely worn out in both systems. It was more notable in the case of 3i systems than in that of Avana systems. 3. In the SEM view of the internal hexagon of abutment, Gingi-Hue abutment of 3i systems showed severe wear in micro-stop contacts that were machined into the corners to prevent rotation and cemented abutment of Avana systems showed wear in both surface area adjacent to the corner mating with external hexagon of implant fixture. 4 The mean values of rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment were 0.48$\pm$0.04$^{\circ}$ in pre-tested 3i systems and 1.18$\pm$0.25$^{\circ}$ after test, and 1.80$\pm$0.04$^{\circ}$ in pre-tested Avana systems and 2.61$\pm$0.16$^{\circ}$ after test. 5. Changes of rotational freedom after test shouted statistical)y a significant increase in both 3i and Avana systems(P<0.05, paired t-test). 6. Statistically, there was no significant difference between amount of increase in the rotational freedom of 3i systems and amount of increase in that of Avana ones(P>0.05, unpaired t-test). Conclusion: Conclusively, it was considered that repeated delivery and remove of abutment by 20 times would not have influence on screw joint stability. However, it caused statistically the significant change of rotational freedom in tested systems. Therefore, it is suggested that repeated delivery and remove of abutment should be minimal as possible as it could be and be done carefully Additionally, it is suggested that the means or treatment to prevent the wear of mating components should be devised.

AdaBoost 알고리즘을 이용한 얼굴인식 및 선박용 감시로봇 개발 (Face Recognition using AdaBoost Algorithm and Development of Surveillance Robot for a Ship)

  • 고석조;박장식;장용석;최문호
    • 로봇학회논문지
    • /
    • 제3권3호
    • /
    • pp.219-225
    • /
    • 2008
  • This study developed a surveillance robot for a ship. The developed robot consists of ultrasonic sensors, an actuator, a lighting fixture and a camera. The ultrasonic sensors are used to avoid collision with obstacles in the environment. The actuator is a servo motor system. The developed robot has four drive wheels for driving. The lighting fixture is used to guide the robot in a dark environment. To transmit an image, a camera with a pan moving and a tilt moving is equipped on the upper part of the robot. AdaBoost algorithm trained with 15 features, is used for face recognition. In order to evaluate the face recognition of the developed robot, experiments were performed.

  • PDF