Development of Microarrayer for Manufacturing DNA Chip (DNA 칩 제작을 위한 로봇 시스템의 개발)

  • 이현동;김기대;나건영;임용표
    • Journal of Biosystems Engineering
    • /
    • v.28 no.5
    • /
    • pp.429-438
    • /
    • 2003
  • This study exploits the robot system which is necessary in gene study and bio-technology industry. As well, a DNA chip, which of use has been increased recently, can be manufactured with this system. The robot consists of a device spotting DNA on the silylated slide, a well plate, a bed for fixing well plates, devices of washing and drying the pin in DNA spotting .device, a distillation-water vessel, and a discharge vessel of wash water. We made the period of sticking DNA to the pin on the well plate to be 15 seconds. The spot size of DNA was set to be 0.28 mm on the average by bringing the slide into contact with pin during 1 second. If DNA is spotted in minimum space possible about 0.32mm, this system can stick about 8,100 DNA spots on the well plate with this rate. Analyzing the procedure: Movement starts, Pin washes, dries, and smears DNA on the well plate. Spotting DNA onto 12 chips took 2 minutes and 50 seconds.

A Study on the Development of Grating Structure for Drain of Water (도로 배수용 그레이팅 구조의 개선에 관한 연구)

  • Kim Key-Sun;Lee Eun-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.4
    • /
    • pp.531-538
    • /
    • 2006
  • Grating is an installed structure on the road for drain. This paper proposes a new product which can prevent the accumulation of earth and sand through the improvement of Grating structure. There were usually harmful insects and bad smell because of accumulated garbage in the frame of previous product. The product had a reverse-flowing sewage due to the bad draining in case of rain. The whole thing of the existing Grating installed with the one set of frame and main body should be changed when it was damaged. This study is to develop a structure which can separate grating main body from frame and grating main body can equip and separate after fixing frame to the manhole with cement. also install jig for the loss prevention and change for the better.

  • PDF

The Difference of Price Zone Evaluation According to Type of Consumer and Purchasing Behavior

  • KIm, Jung-Won
    • Fashion & Textile Research Journal
    • /
    • v.4 no.6
    • /
    • pp.517-523
    • /
    • 2002
  • This study examines whether there are differences in consumer's evaluation price zone on the clothing clue (the type of clothing, brand, time of fashion, place of origin, material. submaterial, place for sale) according to consumer purchasing behavior. Therefore the ultimate goal is to offer help in fixing price when establishing marketing of the clothing industry by grasping the actual price set by consumers under the IMP system. The female consumers of 20s and 30s were chosen as study subjects for their sensitivity to the purchase of clothing. The tests carried out in this research are: SPSSIPC+ is used for frequency Analysis. The Results of this study are showed as the following: It was analyzed that 4 types of consumer are the reasonable consumption oriented consumer, fashion oriented consumer, the no care of fashion consumer and high price oriented consumer Among the several kinds such as the type of clothing, brand, time of fashion, place of origin, material, submaterial, place for sale, only on the type of clothing, there are difference in the type of the consumers, on the time of buying clothes, in the behavior of buying clothes and also on the degree of fashion and the place of origin among such kinds.

Effects of Auricular Acupressure Therapy on Nocturia and Insomnia in the Elderly (노인에게 적용한 이압요법이 야뇨와 불면증에 미치는 효과)

  • Kim, Ji Yeon;Ryu, Hye Sook;Nam, Seok Hoon;Park, Kyung Sook
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2014
  • Purpose: The purpose of this study was to confirm the effects of auricular acupressure therapy on insomnia and nocturia in the elderly. Methods: This study was a nonequivalent control group pre-post test design. Data collection was conducted from July 1 to August 31, 2013. Subjects were set for totally 36 people with 18 people in the experimental group and 18 people in the control group among the elderly over the age of 60 in silver town, welfare center, and senior citizen center where are located in Seoul area. For the experimental group, auricular acupressure therapy was applied two times during 5 days by fixing it to auricular reaction site with tape using Sinapis alba L. seeds. With SPSS/WIN 19.0 program, the collected data were analyzed. Results: Compared to the control group, the sleeping score and sleeping satisfaction were improved and nocturia frequency was lowered in the experimental group who applied auricular acupressure therapy. Conclusion: Auricular acupressure therapy was considered to be likely useful therapeutic method for the effects of relieving nocturia and insomnia in elderly.

Changes in Mechanical Properties according to Solid Solution Treatment of Cu-1.6%Co-0.38%Si Alloy (Cu-1.6%Co-0.38%Si 합금의 용체화처리에 따른 기계적 성질의 변화)

  • Kwak, Wonshin;Lee, Sidam
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.33 no.6
    • /
    • pp.277-283
    • /
    • 2020
  • Cu-Co-Si based alloy has a strengthening mechanism for Co2Si intermetallic compounds deposited on the copper matrix after aging treatment and the solution treatment has a key influence on the strength and electrical conductivity of the final products. In this paper, the Cu-1.6%Co-0.38%Si alloy was fixed at the time and the solution treatment temperature was set at a temperature in the range of 800 to 950℃, and the change in mechanical properties was observed by fixing the temperature at 950℃ and changing the time. The microstructure was observed using an electron microscope and an optical microscope, and the changes in hardness, electrical conductivity, and bending workability after aging treatment were investigated. When the solution treatment time is less than 20 seconds, the solution treatment is not sufficient and the formation of precipitates contributing to the increase in hardness decreases and the hardness decreases after the aging treatment, and in more than 50 seconds, the hardness decreases due to the coarsening of the grains and the bending workability got worse.

Compact and Wideband Coupled-Line 3-dB Ring Hybrids (Coupled Line으로 구성된 작고 넓은 대역폭을 가지는 3-dB Ring Hybrids)

  • Ahn, Hee-Ran;Kim, Jung-Joon;Kim, Bum-Man
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.8
    • /
    • pp.862-877
    • /
    • 2008
  • In this paper, two types of wideband 3-dB ring hybrids are compared and discussed to show the ring hybrid with a set of coupled-line sections better. However, the better one still has a realization problem that perfect matching can be achieved only with -3 dB coupling power. To solve the problem, a set of coupled-line sections with two shorts is synthesized using one- and two-port equivalent circuits and design equations are derived to have perfect matching, regardless of the coupling power. Based on the design equations, a modified ${\Pi}-type$ of transmission-line equivalent circuit is newly suggested. It consists of coupled-line sections with two shorts and two open stubs and can be used to reduce a transmission-line section, especially when its electrical length is greater than ${\pi}$. Therefore, the $3\;{\lambda}/4$ transmission-line section of a conventional ring hybrid can be reduced to less than ${\pi}/2$. To verify the modified ${\Pi}-type$ of transmission- line equivalent circuit, two kinds of simulations are carried out; one is fixing the electrical length of the coupled-line sections and the other fixing its coupling coefficient. The simulation results show that the bandwidths of resulting small transmission lines are strongly dependent on the coupling power. Using modified and conventional ${\Pi}-types$ of transmission-line equivalent circuits, a small ring hybrid is built and named a compact wideband coupled-line ring hybrid, due to the fact that a set of coupled-line sections is included. One of compact ring hybrids is compared with a conventional ring hybrid and the compared results demonstrate that the bandwidth of a proposed compact ring hybrid is much wider, in spite of being more than three times smaller in size. To test the compact ring hybrids, a microstrip compact ring hybrid, whose total transmission-line length is $220^{\circ}$, is fabricated and measured. The measured power divisions($S_{21}$, $S_{41}$, $S_{23}$ and $S_{43}$) are -2.78 dB, -3.34 dB, -2.8 dB and -3.2 dB, respectively at a design center frequency of 2 GHz, matching and isolation less than -20 dB in more than 20 % fractional bandwidth.

Dose and Image Assessment according to Radiologic Factors Variation at Digital Humerus X-ray Examination (디지털 환경에서 Humerus 검사 시 촬영인자 변화에 따른 선량 및 화질 평가)

  • Kim, Seong Min;Hong, Seon Sook;Lee, Kwan Sup;Ha, Dong Yun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.1-8
    • /
    • 2012
  • Purpose : We aim at presenting the optimum radiologic factor through the evaluation of dose variation and of image quality through the use of a grid in Humerus examination and the change of dose because of the change of radiologic factor. Materials and Methods : We divided it in 3 cases: when using a grid or not and when using IP(Image Plate) in a digital system. Also, as fixing kVp to 70kVp it changed mAs, and fixing mAs to 10 it changed kVp, we put up resolution chart and Burger rose phantom on the acrylic phantom of 7cm (the same level of Humerus) to evaluate the dose and image. We used Image J program to evaluate the quantitative resolution of the obtained image, and made the qualitative evaluation and statistical analysis of the image saved in PACS for 20 radiologic technologist with more than 10 years of experience in order of evaluate its contrast. We used SPSS10(SPSS Inc. Chicago, Illinois) for statistical analysis. Results : We observed the analytic result of resolution by the change of kVp that it was $4.539dGycm^2$ in 60kVp and $757.472dGycm^2$ in 75kVp, which increased about 64.6% of dose, while for the resolution it had the pixel value 30.7% better with 851 in 60kVp than 651 in 75kVp. Also, we analyzed the result of resolution by the change of mAs that it was $3.106dGycm^2$ in 5mAs, and $12.470dGycm^2$ in 20mAs, which increased about 400% of dose, while for the resolution DR had 678 in 5mAs, and 724 in 20mAs that increased about 6.8% of resolution. We made the qualitative evaluation of contrast by the change of kVp that DR showed the higher quality than CR, but the contrast by the change of kVp had no special different at the moment of visual evaluation, nor statistically significant difference(P>0.05). We observed the qualitative evaluation of contraste by the change of mAs that the contrast increased as DR increased mAs, and had statistically significant difference(P<0.05). On the other hand, CR had no significant difference for more than 10mAs nor statistically significant difference(P>0.05). Conclusion : In case of some patients with radiographic exposure by the repeated examination such as emergent patient or Follow up patient, they are considered to try to limit the use of a grid, to set kVp under 65kVp in fixed mode, to select less than 10mAs and to reduce the possibility of patient being bombed.

  • PDF

International Airfares and Application of Competition Laws (국제항공운임과 국내 경쟁법규의 적용)

  • Shin, Dong-Chun
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.26 no.1
    • /
    • pp.93-125
    • /
    • 2011
  • The International Civil Aviation Convention (Chicago Convention) has been a backbone of international air transport system whereby air transport between States should be based on bilateral agreements, and in particular, international airfares, which are set up through IATA(International Air Transport Association) rate-fixing machinery could be approved by the governments concerned. International airfares are fares for transporting passenger and freight and their conditions between two or more countries. However, since U.S. pursued th deregulation policy in 1978 whereby routes, capacity and fares could be freely determined by airlines, many States have been following so called open-skies agreements. In many cases, aeronautical and competent authorities have been reviewing whether airlines' commercial activities including air fares could possibly conflict with free competition rules envisaged in relevant laws and regulations. As competition among airlines gets intense, airlines often resort to cooperation with other airlines in the forms such as equity exchange, M&A, code-sharing, fares consultation and resource pooling, mainly with a view to effectively use resources available and to avoid monopoly situation resulting from excessive and destructive competition among players. Whereas bearing in mind that application of competition laws is important to secure consumers' interests by preventing airlines's malpractices such as bargaining exorbitant fares, it is also important to comprehensively consider as many factors as possible, from that unilateral measure by governments may bring about retaliatory measures by the governments affected, to that airlines' cooperative practices may rather increase consumers' benefits by lowering air fares.

  • PDF

Tool-Setup Measurement Technology of High Speed Precision Machining Tool (고속 정밀 가공기의 공구셋업 측정기술)

  • 박경택;신영재;강병수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1066-1069
    • /
    • 2004
  • Recently the monitoring system of tool setup in high speed precision machining tool is required for manufacturing products that have highly complex and small shape, high precision and high function. It is very important to reduce time to setup tool in order to improve the machining precision and productivity and to protect the breakage of cutting tool as the shape of product is smaller and more complex. Generally, the combination of errors that geometrical clamping error of fixing tool at the spindle of machining center and the asynchronized error of driving mechanism causes that the run-out of tool reaches to 3∼20 times of the thickness of cutting chip. And also the run-out is occurred by the misalignment between axis of tool shank and axis of spindle and spindle bearing in high speed rotation. Generally, high speed machining is considered when the rotating speed is more than 8,000 rpm. At that time, the life time of tool is reduced to about 50% and the roughness of machining surface is worse as the run-out is increased to 10 micron. The life time of tool could be increased by making monitoring of tool-setting easy, quick and precise in high speed machining center. This means the consumption of tool is much more reduced. And also it reduces the manufacturing cost and increases the productivity by reducing the tool-setup time of operator. In this study, in order to establish the concept of tool-setting monitoring the measuring method of the geometrical error of tool system is studied when the spindle is stopped. And also the measuring method of run-out, dynamic error of tool system, is studied when the spindle is rotated in 8,000 ∼ 60,000 rpm. The dynamic phenomena of tool-setup is analyzed by implementing the monitoring system of rotating tool system and the noncontact measuring system of micro displacement in high speed.

  • PDF

Thermal Image Real-time estimation and Fire Alarm by using a CCD Camera (CCD 카메라를 이용한 열화상 실시간 추정과 화재경보)

  • Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.92-98
    • /
    • 2016
  • This study evaluated thermal image real-time estimation and fire alarm using by a CCD camera, which has been a seamless feature-point analysis method, according to the angle and position and image fusion by a vector coordinate point set-up of equal shape. The system has higher accuracy, fixing data value of temperature sensing and fire image of 0~255, and sensor output-value of 0~5,000. The operation time of a flame specimen within 500 m, 1000 m, and 1500 m from the test report specimen took 7 s, 26 s, and 62 s, respectively, and image creation was proven. A diagnosis of fire accident was designated to 3 steps: Caution/Alarm/Fire. Therefore, a series of process and the transmission of SNS were identified. A light bulb and fluorescent bulb were also tested for a false alarm test, but no false alarm occurred. The possibility that an unwanted alarm will be reduced was verified through a forecast of the fire progress or real-time estimation of a thermal image by the change in the image of a time-based flame and an analysis of the diffusion velocity.