• Title/Summary/Keyword: Fixed time method

Search Result 1,342, Processing Time 0.03 seconds

Link Capacity Assignment in Computer-communication Networks (컴퓨터 통신네트워크에서 링크의 용량배정)

  • 정인명;강창언
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1983.10a
    • /
    • pp.108-111
    • /
    • 1983
  • This paper presents a new method for the optimum capacity assignment in store-and-forward communication networks under a total fixed-capacity constraints. Any two link capacities needed in this method can have the desirable quantites and then other capacities can be obtained from the fixed two link capacities. When the minimum and the maximum capacities that are the quantites of the conventional method are fixed, the total average time delay from the new method is almost the same as that from the conventional method. And when the minimum capacity is fixed, the new method gives smaller average time delay.

  • PDF

Improvement of Histopathological Sample Preparation by Employing Microwave Heating Method on Frozen Section Specimens

  • Ahn, Seung-Ju
    • Biomedical Science Letters
    • /
    • v.13 no.4
    • /
    • pp.361-368
    • /
    • 2007
  • Biological samples can be fixed either by chemical method by using chemical solution or physical methods by using heat treatment. The problem in traditional heat fixation is unsatisfactory quality due to uneven heat conduction in specimen and loss of inner cell contents. Chemical fixation method also bears several intrinsic problems like the limit in specimen size, time consumption in fixative impregnation, and loss of low molecular weight cell components. These factors deteriorate the quality of fixed specimen, thus limit the magnification and contrast of tissue pictures. Microwave heat has been reported to be a good alternative to current chemical methods to overcome these problem. In this study, we tried to introduce the microwave energy method to routine fixation work in hospital. We replaced chemical fixative with saline to provide moderate reaction condition, and used frozen section to reduce time for sample preparation. Temperature was measured at each experiment. The fixation of rat kidney tissue with 2.45 GHz electromagnetic wave and saline showed similar result to the control group fixed with traditional chemical method. Human tumor tissue fixed with 2.45 GHz electromagnetic in frozen section was improved in terms of histochemistry of PAS and immunohistochemistry of tumor marker like cytokeratin. Total turnaround time was reduced from $24\sim38$ h to to $2\sim4$ h. In conclusion, the quality of samples prepared by microwave heating method was at least as good as that of traditional method. If the condition for the fixation of different specimens is standardized, this new method could be applied to routine work in hospital, and could save working time as well.

  • PDF

A Development of Fixed Address Type Automatic Tool Change System for Machine Tool (공작기계용 고정번지식 자동 공구교환 시스템 개발)

  • 이춘만;허영진
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1150-1153
    • /
    • 2003
  • Recently, Many studies have been undergoing to reduce a working time in a field of machine tool. There are two ways of reducing working time; to reduce actual working time by heighten spindle speed and to reduce stand-by time by shortening tool exchange time. Automatic tool change system belongs to the latter case. Fixed address type automatic tool change system that is being developed in this study can store more number of tool in small space than magazine transfer type automatic tool changer as well as shorten tool exchange time. In this paper, a simplified equivalent model of finite element method in order to analyze frame structure of fixed address type automatic tool change system is presented.

  • PDF

Numerical Analysis of Free Surface Flows Using Adaptable Surface Particle Method based on Grid System (격자기반 적합 표면입자법을 이용한 자유표면유동 수치해석)

  • Shin, Young-Seop
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.1
    • /
    • pp.26-33
    • /
    • 2017
  • In this study, the surface marker method, one of the particle tracking methods, used to track the free surface is extended to cover the more general cases easily including the collision and separation of the free surface. In surface particle method to redistribute particles effectively using the grid system, the free surface is composed of the sum of quadrilaterals having four curves where fixed markers are placed at ends of each curve. Fixed markers are used to know how curves are connected to each other. The position of fixed markers can move as the free surface deforms but all fixed markers cannot be deleted during all time of simulation to keep informations of curve connection. In the case of the collision or separtion of the free surface where several curves can be intersected disorderly, severe difficulties can occur to define newly states of curve connection. In this study, the adaptable surface parTicle method without fixed markers is introduced. Intersection markers instead of the fixed markers are used to define quadrilaterals. The position of the intersection markers is defined to be the intersection point between the free surface and the edge of the grid and it can be added or deleted during the time of simulation to allow more flexibilities. To verify numerical schemes, two flow cases are simulated and the numerical results are compared with other's one and shown to be valid.

A Study on the Castability of Non-precious Porcelain Metal According to Investing Method (매몰방법에 따른 도재용 비금속의 주조성에 관한 연구)

  • Lee, In-Kyu;Kim, Yong-Won
    • Journal of Technologic Dentistry
    • /
    • v.19 no.1
    • /
    • pp.5-12
    • /
    • 1997
  • To examine the difference of castability of non -precious porcelain metal according to 2 type of investing method, experiments were carried out using the method of both existing investing method and the investment with spaces to the upper & lower parts of the ring. The following conclusion were obtained from the result. 1. Seperataly using the existing investment and with spaces to the upper & lower parts of the ring, 44 samples resulted in success with the former method and 52 with the latter out of 84 samples. 2. Under the existing investing method, 44 samples out of 56 total resulted in success when the temperature of the ring was $870^{\circ}C$, and all samples failed when the temperature was $800^{\circ}C$. 3. Under the investment that gives space to the ring, when casted with the temperature of the ring fixed at $870^{\circ}C$, 40 samples out of 56 and 17 samples with the temperature fixed at $800^{\circ}C$ resulted in success. 4. Under the existing investing method with the temperaure of the ring fixed at $870^{\circ}C$ and heat soaking time given an hour, 26 out of 28 samples resulted in success and 18 resulted the same with half an hour heat soaking time. 5. Using the investment that gives space to the ring, at ring temperature $870^{\circ}C$ with heat soaking time 1 hour, all of total 28 rusulted insuccess however only 12 smaples succeeded with 30 minutes heat soaking time. 6. Under the existing investing method, samples with heat soaking time 1 hour equally given at ring temperature $870^{\circ}C$, 26 samples out of 28 succeed however at $800^{\circ}C$ all samples failed. 7. In the case of ring's upper and lower parts opened ring temperature is $870^{\circ}C$ and $800^{\circ}C$ and the heat soaking time was fixed at 1 hour, all 28 samples resulted in success and at $800^{\circ}C$ 17 succeed.

  • PDF

A Study on the Development of Fixed Address Type Automatic Tool Changer (고정번지식 ATC개발에 관한 연구)

  • 이춘만;허영진
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1015-1018
    • /
    • 2002
  • Recently, many studies have been undergoing to reduce a working time in a field of machine tool. There are two ways of reducing a working time; to reduce an actual working time by heighten a speed of spindle and to reduce a stand-by time by shortening a tool exchanging time. ATC(Automatic Tool changer) belongs to the latter case. Fixed address type ATC that is being developed ill this study can store more number of tool in small space than magazine transfer type ATC relatively as well as shorten tool exchanging time. In this study, a simplified equivalent model of finite element method in order to analyze structure of fixed address type ATC.

  • PDF

A Practical Method for Designing Vehicle Routing with Time Windows in Warehouse (정시배송체계의 실용적 설계를 위한 방법론)

  • Byeon, Eui-Seok
    • IE interfaces
    • /
    • v.13 no.3
    • /
    • pp.455-461
    • /
    • 2000
  • Logistics systems can be evaluated by how productively distribution center operates, how promptly transportation vehicle dispatches, how efficiently facility layout is, and so on. In this paper, a practical vehicle routing scheme with fixed delivery time and fixed vehicle routes is introduced. The method helps the distribution center reduce logistics cost with respect to dispatching vehicles, and satisfy the customer with pre-determined delivery time window constraints. A case study has shown that the proposed scheme not only generates a feasible schedule with time windows, but also balances material flow in warehouse.

  • PDF

The Investigation of a Novel Indicator System for Trace Determination and Speciation of Selenium in Natural Water Samples by Kinetic Spectrophotometric Detection

  • Gurkan, Ramazan;Ulusoy, Halil Ibrahim
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.1907-1914
    • /
    • 2010
  • A novel catalytic kinetic method is proposed for the determination of Se(IV), Se(VI) and total inorganic selenium in water based on the catalytic effect of Se(IV) on the reduction of bromate by p-nitrophenylhydrazine at pH 3.0. The generated bromine, $Br_2$ or $Cl_2$ plus $Br_2$ in 0.1 M NaCl (or NaBr) environment efficiently decolorized Calmagite and the reaction was monitored spectrophotometrically at 523 nm as a function of time. In this indicator reaction, bromide acted as an activator for the catalysis of selenium (IV) and a reducing agent for selenium (VI) at pH 3.0, which allowed the determination of total selenium. The fixed time method was adopted for the determination and speciation of inorganic selenium. Under the optimum conditions, the calibration graph are linear in the range 1 - 35 ${\mu}gL^{-1}$ of Se(IV) for the fixed time method at $25^{\circ}C$. The detection limit based on statistical $3S_{blank}$/m-criterion was 0.215 ${\mu}gL^{-1}$ for the fixed time method (7 min). All of the variables that affect the sensitivity at 523 nm were investigated, and the optimum conditions were established. The interference effect of various cations and anions on the Se (IV) determination was also studied. The selectivity of the selenium determination was greatly improved with the use of the strongly cation exchange resin such as Amberlite IR120 plus. The proposed kinetic method was validated statistically and through recovery studies in natural water samples. The RSDs for ten replicate measurements of 5, 15 and 25 ${\mu}gL^{-1}$ of Se(IV) and Se(VI) was changed between 2.1 - 4.85%. Analyses of a certified standard reference material (NIST SRM 1643e) for selenium using the fixed-time method showed that the proposed kinetic method has good accuracy. Se(IV), Se(VI) and total inorganic selenium in environmental water samples have been successfully determined by this method after selective reduction of Se(VI) to Se(IV).

Fixed-point Iteration for the Plastic Deformation Analysis of Anisotropic Materials (이방성 재료의 소성변형 해석을 위한 고정점 축차)

  • Seung-Yong Yang;Jeoung Han Kim
    • Journal of Powder Materials
    • /
    • v.30 no.1
    • /
    • pp.29-34
    • /
    • 2023
  • A fixed-point iteration is proposed to integrate the stress and state variables in the incremental analysis of plastic deformation. The Conventional Newton-Raphson method requires a second-order derivative of the yield function to generate a complicated code, and the convergence cannot be guaranteed beforehand. The proposed fixed-point iteration does not require a second-order derivative of the yield function, and convergence is ensured for a given strain increment. The fixed-point iteration is easier to implement, and the computational time is shortened compared with the Newton-Raphson method. The plane-stress condition is considered for the biaxial loading conditions to confirm the convergence of the fixed-point iteration. 3-dimensional tensile specimen is considered to compare the computational times in the ABAQUS/explicit finite element analysis.

A Study on the Development of the Real-Time G.723.1 Speech Codec Using a Fixed-Point DSP(ADSP-2181) (고정소수점 DSP(ADSP-2181)을 이용한 실시간 G.723.1 음성부호화기 개발에 관한 연구)

  • Park, Jung-Jae;Chung, Ik-Joo
    • Speech Sciences
    • /
    • v.3
    • /
    • pp.177-186
    • /
    • 1998
  • This paper describes the procedure of implementing a real-time speech codec, G.723.1 which was developed by DSP Group and standardized by ITU-T, using fixed-point DSP, ADSP-2181. This codec has two bit rates associated with it, 5.3 and 6.3 kbit/s. We implemented only one bit rate, 6.3 kbit/s, of the two with fixed-point 32-bit precision. According to the result of the experiment, the amount of computational burden is about 55 MIPS and its quality is similar to the result of the PC simulation with floating-point arithmetic. In this paper, we proposed a method to use a fixed-point DSP and a procedure for developing a real-time speech codec using DSPs and finally developed a G.723.l speech codec for ADSP-2181.

  • PDF