• Title/Summary/Keyword: Fixed length

Search Result 1,086, Processing Time 0.032 seconds

Size and Aspect Ratio Effects on the Magnetic Properties of a Spin-Valve Multilayer by Computer Simulation

  • Lim, S.H.;Han, S.H.;Shin, K.H.;Kim, H.J.
    • Journal of Magnetics
    • /
    • v.5 no.3
    • /
    • pp.90-98
    • /
    • 2000
  • The change in the magnetic properties of a spin-valve multilayer with the structure IrMn (9 m)/CoFe (4 nm)/Cu (2.6 nm)/CoFe (2 nm)/NiEe (6 nm) is investigated as a function of the size and the aspect ratio. At a fixed aspect ratio (the length/width ratio) of 2, the magnetostatic interactions begin to affect the magnetic properties substantially at a spin-valve length of 5 $\mum$, and, at a length of 1 $\mum$, they become even more dominant. In the case of a fixed multilayer size (2.4 $\mum$) which is indicated by the sum of the length and the width, magnetization change occurs by continuous spin-reversal and M-H loops are characterized by no or very small hysteresis at aspect ratios smaller than unity, At aspect ratios greater than unity, magnetization change occurs by spin-flip resulting in squared hysteresis loops. A very large changes in the coercivity and the bias field is observed, and these results are explained by two separate contributions to the total magnetostatic interactions: the coercivity by the self-demagnetizing field and the bias field by the interlayer magnetostatic interaction field.

  • PDF

Host Anomaly Detection of Neural Networks and Neural-fuzzy Techniques with Soundex Algorithm (사운덱스 알고리즘을 적용한 신경망라 뉴로-처지 기법의 호스트 이상 탐지)

  • Cha, Byung-Rae;Kim, Hyung-Jong;Park, Bong-Gu;Cho, Hyug-Hyun
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.15 no.2
    • /
    • pp.13-22
    • /
    • 2005
  • To improve the anomaly IDS using system calls, this study focuses on Neural Networks Learning using the Soundex algorithm which is designed to change feature selection and variable length data into a fixed length learning pattern. That is, by changing variable length sequential system call data into a fixed length behavior pattern using the Soundex algorithm, this study conducted neural networks learning by using a backpropagation algorithm with fuzzy membership function. The back-propagation neural networks and Neuro-Fuzzy technique are applied for anomaly intrusion detection of system calls using Sendmail Data of UNM to demonstrate its aspect of he complexity of time, space and MDL performance.

External apical root resorption 6 months after initiation of orthodontic treatment: A randomized clinical trial comparing fixed appliances and orthodontic aligners

  • Toyokawa-Sperandio, Katia Cristina;Conti, Ana Claudia de Castro Ferreira;Fernandes, Thais Maria Freire;de Almeida-Pedrin, Renata Rodrigues;de Almeida, Marcio Rodrigues;Oltramari, Paula Vanessa Pedron
    • The korean journal of orthodontics
    • /
    • v.51 no.5
    • /
    • pp.329-336
    • /
    • 2021
  • Objective: To compare the magnitude of external apical root resorption (EARR) 6 months after starting orthodontic treatment using orthodontic aligners (OAs) and fixed appliances (FAs). Methods: This parallel randomized clinical trial included 40 patients randomized into two groups: OA group (n = 20, 160 incisors) and FA group (n = 20, 160 incisors). For evaluation of the tooth length, periapical radiographs and standardized linear measurements of the maxillary and mandibular incisors were acquired before (T0) and 6 months after treatment initiation (T1). EARR was calculated through the difference in length between the two time points (T1-T0). Statistical comparisons were performed by means of using t-tests, chi-squared test and covariance analysis (a = 5%). Results: Rounding of the root apex was observed in both groups; the resorption involved 2.88% of the root length, so 97.12% of the tooth length remained intact. Intragroup comparisons between the two time points revealed a significant difference, with (T1-T0) ranging from -0.52 to -0.88 mm in the FA group and from -0.52 to -0.85 mm in the OA group. In the intergroup comparisons, only tooth #21 presented a statistically significant difference (OA: -0.52 ± 0.57 mm, FA: -0.86 ± 0.60 mm); however, the overall differences between groups were not clinically relevant, ranging from 0.03 to 0.35 mm. Conclusions: OA and FA treatment resulted in a similar degree of EARR in the maxillary and mandibular incisors at 6 months after treatment initiation. However, the amount of resorption was small and does not impair tooth longevity.

Generation of Fixed Spectral Basis for Three-Dimensional Mesh Coding Using Dual Graph

  • Kim Sung-Yeol;Yoon Seung-Uk;Ho Yo-Sung
    • Proceedings of the IEEK Conference
    • /
    • summer
    • /
    • pp.137-142
    • /
    • 2004
  • In this paper, we propose a new scheme for geometry coding of three-dimensional (3-D) mesh models using a fixed spectral basis. In order to code the mesh geometry information, we generate a fixed spectral basis using the dual graph derived from the 3-D mesh topology. After we partition a 3-D mesh model into several independent sub-meshes to reduce coding complexity, the mesh geometry information is projected onto the generated orthonormal bases which are the eigenvectors of the Laplacian matrix of the 3-D mesh. Finally, spectral coefficients are coded by a quantizer and a variable length coder. The proposed scheme can not only overcome difficulty of generating a fixed spectral basis, but also reduce coding complexity. Moreover, we can provide an efficient multi-resolution representation of 3-D meshes.

  • PDF

Optimization of a Thermally Asymmetric Rectangular Fin: Based on Fixed Fin Height

  • Kang, Hyung-Suk
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.3
    • /
    • pp.145-151
    • /
    • 2005
  • A thermally asymmetric straight rectangular fin is analysed and optimized using the two-dimensional separation of variables method. The optimum heat loss is presented as a function of bottom to top Biot number ratio, fin base length and top Biot number. Decreasing rate of the optimum fin length with the increase of the fin base length is listed. The optimum fin tip length is shown as a function of bottom to top Biot number ratio, fin base length and tip to top Biot number ratio. One of the results shows that the optimum heat loss and the actual optimum fin length decrease while the optimum fin tip length increases as the fin base length increases.

Out-of-Plane Elastic Buckling of X-Bracing System with Fixed Ends (고정 지점을 갖는 X-브레이싱의 탄성 면외 좌굴)

  • Moon, Ji-Ho;Yoon, Ky-Yong;Lee, Hak-Eun
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.293-296
    • /
    • 2007
  • This study investigated the out-of-plane elastic buckling load and effective length factor of X-bracing system. The members of X-bracing system which are studied in this paper are rigidly attached to the structure at their end connections, and are pinned or rigidly connected at their point of intersection. The effective length factors are derived for the general case where the tension and compression brace have different material and geometrical properties.

  • PDF

Wetting Characteristics of Water Droplet on the Solid Surfaces with Variable Pillar-Type Nanostructures (다양한 기둥 타입을 가지는 나노 구조물 고체 표면에서의 물 액적 젖음 특성)

  • Yoo, Min Jung;Kwon, Tae Woo;Ha, Man Yeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.10
    • /
    • pp.659-666
    • /
    • 2016
  • A numerical study, using the molecular dynamics simulation method, was carried out to investigate the wetting characteristics of water droplets on a solid square pillar surface with variable periodic edge length patterns at the nanoscale. In this study, the pillar plane was supposed to be rectangular or square shaped. In addition, the surface area was increased while the shape of the pillar plane was kept fixed. In the case of the square pillar, the edge length increased from $4.24{\AA}$ to $12.72{\AA}$. Also, the rectangular pillar had two types of length edges. In this case, one edge length was fixed at $8.48{\AA}$ and the other edge length was increased from $4.24{\AA}$ to $12.72{\AA}$. Through these length changes, the hydrophobicity and hydrophilicity of a water droplet on the variable pillar surfaces were analyzed.

A Study on Standardization of Pattern Design of Korean Men's Traditional Trousers (한복바지 원형설계의 표준화를 위한 연구)

  • 정옥임
    • Journal of the Korean Home Economics Association
    • /
    • v.39 no.10
    • /
    • pp.97-109
    • /
    • 2001
  • It is thought that a composition of trousers is related to fabrics with single breadth. Therefore, trousers are designed with pattern using this fabrics with single breadth. However, in the old pattern of trousers, the breadth of 33cm-35cm was not considered in designing patterns. In this context, deciding which pattern design is better is not easy as there are a variety of estimation methods. So in this study, standardization of drafting is pursued by an objective pattern design. For this, a base angle of the trouser closely relating to a form and function was measured and using the height and the base angle, a trouser pattern design was tried. For a measurement of the base angle, 5 subject were selected. They are 25-29 year-old male graduates with fine physical standard. The base angle was measured with symphysis pubis point as a standard when subjects sat with their legs crossed, when they stood with their legs open (not forced artificially) and when they laid down with their legs open. The distance between a knee inside joint and knees was measured three times and the resultant value was used for the pattern design. For a design of trousers, the height was applied and the base angle was fixed. As a pattern drawing, using the height, a base angle and circumference of the hip, a trouser was designed. The production method for the pattern design is as follow: (1) The length formula, is height + $\frac{height}{2}$ (2) The hip girth formula is $\frac{hipgirth}{2}$ - $\frac{hipgirth}{20}$(3) A crotch angle is fixed at $72^{\circ}$. (4) The ratio of outer leg length to leg width is 5 : 8. (5) The component ratio of the upper outer leg length to the pant length is 5 : 8. (6) The ratio of the division point of front right inner leg length and left inner width to upper outer leg length is 5 : 8.

  • PDF

Difference of Suaeda japonica Populations from two Different Habitats in Sorae, Incheon, Korea (인천 소래 간석지내 두개의 칠면초 ( Suadeda japonica ) 개체군간의 차이에 관하여)

  • Lee, Kun-Seop;Oh, Kye-Chil
    • The Korean Journal of Ecology
    • /
    • v.12 no.3
    • /
    • pp.133-144
    • /
    • 1989
  • The morphology and flowering time of two Suaeda japonica populations from different habitats, the creek and the bank of the mudflat in Sorae, were surveyed. And standard transplantation and reciprocal transplantation were carried out to determine whether their characteristics were genetically fixed or not. Also soil sample of these habitats were analyzed. The amounts of loss on ignition, maximum field capacity, total nitrogen, exchangeable calcium and potassium, and soluble phosphorus were found to be significantly different between two habitats. Leaf thickness, leaf width, leaf length, stem height number of branches, and number of seeds were significantly different between plants of two populations. And flowering times of two populations did not overlap. According to the results of transplantation, leaf width, leaf thickness, and flowering times were the same as those at their original habitat. But the stem lenght, leaf lenght, number of branches and unmber of seeds were not. Therefore, the differences in the leaf length, leaf thickness, and flowering time seemed to bo genetically fixed. It were suggested that the creek bank populations of Suaeda japoinica were to be considered as different ecotypes.

  • PDF

Determining the Decision Limit of CUSUM Chart for A Fixed Sample Size

  • Kang, Chang Wook;Hawkins, Donglas M.
    • Journal of Korean Society for Quality Management
    • /
    • v.20 no.1
    • /
    • pp.1-10
    • /
    • 1992
  • When we compare different control charting schemes, the average run length of each control chart is usually used. The use of the average run length implies that there is unbounded number of samples or observations. The regression recursive residuals, however, have been applied to the cumulative sum chart to detect whether the mean or variance changes. To implement choice of decision interval, we calculate the probability that certain fixed number of control statistics stay in the in-control state. This probability can be used as the significance level of a test for detecting the change in the residual mean or variance of the data with a finite number of observations.

  • PDF