• 제목/요약/키워드: Fixed grid

검색결과 247건 처리시간 0.03초

국내 연근해 선박의 온실가스 배출량 공간할당 방법에 관한 연구 (A Study on Space Allocation Method of GHGs Emissions from Domestic Coastal Shipping)

  • 김필수;이종태;손지환;최상진;박성규;홍현수;김정수
    • 한국기후변화학회지
    • /
    • 제6권4호
    • /
    • pp.345-355
    • /
    • 2015
  • In this study, we researched a space allocation method of emissions from domestic coastal shipping (passenger ship, cargo ship, fishing boats). We were building a geographic information data that is used in GIS for emissions of space allocation, and presented a methodology capable of performing the space allocated for each grid by calculating the emissions. Passenger ships were assigned emissions of routes each the ship that operated at a fixed. Emissions of crusing mode of cargo ship, was equally assigned to the safe operation line, which is defined for domestic cargo ship. Also, Emissions of maneuvering (moving into or out of port) and hoteling (operations while stationary at dock), was assigned in consideration of anchorage in the major port. Fishing boat was evenly allocated monthly emissions in the country every month fishing grounds formation zone. Based on these results, it tries to provide the basic data that can be used when you want to create a local government measures to reduce scenario in the future.

누설유량과 회전체동역학적 성능을 고려한 래버린스 씰 설계 (Labyrinth Seal Design Considering Leakage Flow Rate and Rotordynamic Performance)

  • 문민주;이정인;서준호
    • Tribology and Lubricants
    • /
    • 제39권2호
    • /
    • pp.61-71
    • /
    • 2023
  • This study proposes a procedure for designing a labyrinth seal that meets both leakage flow rate and rotordynamic performance criteria (effective damping, amplification factor, separation margin, logarithmic decrement, and vibration amplitude). The seal is modeled using a one control volume (1CV) bulk flow approach to predict the leakage flow rate and rotordynamic coefficients. The rotating shaft is modeled with the finite element (FE) method and is assumed to be supported by two linearized bearings. Geometry, material and operating conditions of the rotating shaft, and the supporting characteristics of the bearings were fixed. A single labyrinth seal is placed at the center of the rotor, and the linearized dynamic coefficients predicted by the seal numerical model are inserted as linear springs and dampers at the seal position. Seal designs that satisfy both leakage and rotordynamic performance are searched by modifying five seal design parameters using the multi-grid method. The five design parameters include pre-swirl ratio, number of teeth, tooth pitch, tooth height and tooth tip width. In total, 12500 seal models are examined and the optimal seal design is selected. Finally, normalization was performed to select the optimal labyrinth seal designs that satisfy the system performance requirements.

Experimental and analytical study of a new seismic isolation device under a column

  • Benshuai Liang;Guangtai Zhang;Mingyang Wang;Jinpeng Zhang;Jianhu Wang
    • Earthquakes and Structures
    • /
    • 제24권6호
    • /
    • pp.415-428
    • /
    • 2023
  • Low-cost techniques with seismic isolation performance and excellent resilience need to be explored in the case of rural low-rise buildings because of the limited buying power of rural residents. As an inexpensive and eco-friendly isolation bearing, scrap tire pads (STPs) have the issue of poor resilience. Thus, a seismic isolation system under a column (SISC) integrated with STP needs to be designed for the seismic protection of low-rise rural buildings. The SISC, which is based on a simple exterior design, maintains excellent seismic performance, while the mechanical behavior of the internal STP provides elastic resilience. The horizontal behaviors of the SISC are studied through load tests, and its mechanical properties and the intrinsic mechanism of the reset ability are discussed. Results indicate that the average residual displacement ratio was 24.59%, and the reset capability was enhanced. Comparative experimental and finite element analysis results also show that the load-displacement relationship of the SISC was essentially consistent. The dynamic characteristics of isolated and fixed-base buildings were compared by numerical assessment of the response control effects, and the SISC was found to have great seismic isolation performance. SISC can be used as a low-cost base isolation device for rural buildings in developing countries.

Damage identification of masonry arch bridge under blast loading using smoothed particle hydrodynamics (SPH) method

  • Amin Bagherzadeh Azar;Ali Sari
    • Structural Engineering and Mechanics
    • /
    • 제91권1호
    • /
    • pp.103-121
    • /
    • 2024
  • The smoothed particle hydrodynamics (SPH) method is a numerical technique used in dynamic analysis to simulate the fluid-like behavior of materials under extreme conditions, such as those encountered in explosions or high velocity impacts. In SPH, fluid or solid materials are discretized into particles. These particles interact with each other based on certain smoothing kernels, allowing the simulation of fluid flows and predict the response of solid materials to shock waves, like deformation, cracking or failure. One of the main advantages of SPH is its ability to simulate these phenomena without a fixed grid, making it particularly suitable for analyzing complex geometries. In this study, the structural damage to a masonry arch bridge subjected to blast loading was investigated. A high-fidelity micro-model was created and the explosives were modeled using the SPH approach. The Johnson-Holmquist II damage model and the Mohr-Coulomb material model were considered to evaluate the masonry and backfill properties. Consistent with the principles of the JH-II model, the authors developed a VUMAT code. The explosive charges (50 kg, 168 kg, 425 kg and 1000 kg) were placed in close proximity to the deck and pier of a bridge. The results showed that the 50 kg charges, which could have been placed near the pier by a terrorist, had only a limited effect on the piers. Instead, this charge caused a vertical displacement of the deck due to the confinement effect. Conversely, a 1000 kg TNT charge placed 100 cm above the deck caused significant damage to the bridge.

The Effect of Form Factors and Control Types on Unsorted List Search for Full Touch Phone

  • Lee, Jong-Kee;Park, Jae-Kyu;Kim, Jun-Young;Choe, Jae-Ho;Jung, Eui-S.
    • 대한인간공학회지
    • /
    • 제31권2호
    • /
    • pp.309-317
    • /
    • 2012
  • Objective: The aim of this paper is to inquire into the influences form factors and control types affect a search time and comfort at list menu of full touch phone. Background: Various studies have been proceeded that are related to the optimum touch area for enhancing usability of control and legibility in mobile touch device. In the environment of list menu which is widely used to provide various information effectively, however, not only comprehensive consideration for legibility and control is to be seek but also research for control type which is to scroll a list. Method: This study executed form factor experiment to inquire into the influence that font size, height of row and fixed area affect searching time and comfort in the while information processing even if the information on the list is unsorted in alphabetical order. Among the result of form factor experiment, control type experiment was executed by selecting shortest performance time, highest legibility comfort and control comfort. Control type experiment was implemented to figure out the influence which existing flicking type, scrolling bar type, newly established button page type and button raw types affect performance time and subjective comfort depending on location of the information. Results: Font size 12pt, height of row 7mm and fixed area 15mm was shortest performance time and got highest comfort and legibility score in form factor experiment. A Button page which was newly proposed type was shortest performance time and got highest comprehensive comfort in control type experiment. Conclusion: Form factor experiment showed similar results with the study through reading a long passage of character or controlling a grid icon type. However, height of row turned out to affect not only touch area for control but also legibility by ruling space between the lines. Button page type which was newly proposed showed shortest performance time and got highest comprehensive comfort. Because Button page type needs few finger movements than other control types and implements search in the fixed form, unlikely other type which list keeps moving. Application: This study should be applied in deciding form factors and control type for scroll when designing a list menu of full touch phone.

미세먼지(PM10)의 지역적 대푯값 산정 방법에 관한 연구 - 서울특별시를 대상으로 (Estimation of Representative Area-Level Concentrations of Particulate Matter(PM10) in Seoul, Korea)

  • 송인상;김선영
    • 한국지리정보학회지
    • /
    • 제19권4호
    • /
    • pp.118-129
    • /
    • 2016
  • 미세먼지($PM_{10}$)의 건강영향에 대한 많은 연구들은 정부의 대기오염 측정자료를 이용해서 악영향을 보고했다. 정부 대기오염 측정자료가 제한된 수의 측정소에서 생산되는 반면, 사망률이나 유병률과 같은 정부생산 건강결과 자료는 지역별로 집계되어 공개된다. 따라서 정부에서 생산하는 건강통계자료를 이용해서 건강영향을 분석하기 위해서는, $PM_{10}$ 농도의 지역적인 대푯값을 산출할 필요가 있다. 본 연구에서는 서울특별시를 대상으로 이전 연구에서 개발된 점 사상에 대한 $PM_{10}$ 농도 예측 모형을 이용하여 구별 대푯값을 산정하였다. 이를 위해, 세 가지 종류의 위치들을 대상으로 지점들을 생성한 후, 그 지점들에 예측한 $PM_{10}$ 농도의 구별 평균으로 구별 대푯값을 구했다. 세 가지 위치는 16,230개 집계구 내 가장 넓은 주거지역의 중심점, 424개 동 주민센터, 610개 1km 격자의 중심점이었다. 위치별 구별 대푯값들을 비교하기 위하여 측정치와의 관련성 및 추정치 간 관련성을 탐색하였다. 측정치와의 비교 결과, 측정치와 세 가지 구별 대푯값 추정치들 간의 관련성은 위치의 인구 대표성이 높아짐에 따라 향상되었고($R^2=0.06-0.59$), 상호비교에서는 격자 중심점을 이용한 추정치가 다른 추정치들과의 관련성이 상대적으로 낮았다(0.35-0.47). 본 연구는 $PM_{10}$의 지역별 평균 농도를 추정함으로써 향후 정부 통계에 기반한 전국 규모의 지역 단위 건강영향분석 연구에 기여할 수 있을 것으로 기대된다.

PR제어기를 이용한 단상 계통 연계형 태양광 인버터 설계 (PR Controller Based Current Control Scheme for Single-Phase Inter-Connected PV Inverter)

  • 부우충기엔;성세진
    • 한국산학기술학회논문지
    • /
    • 제10권12호
    • /
    • pp.3587-3593
    • /
    • 2009
  • 최근 태양광 시스템에서는 기존의 태양광 시스템을 계통과 전원으로 상호 접속하는 것에 대한 연구에 관심이 모아지고 있다. 단상, 삼상 시스템에 관계없이 태양광 시스템에서 태양광 인버터는 계통연계 동작에 중요한 역할을 하기 때문에 전체 시스템에서 핵심요소로 고려된다. 태양광 인버터를 제어하기 위해서는 부하 전류 조절이 핵심요소 중 하나이다. 일반적으로 태양광 인버터에서 이용되는 PI 제어기는 정상상태 오차와 왜란에 취약하다는 단점을 가지고 있기 때문에 실제 시스템에 완벽하게 적용하기에는 무리가 있다. 특히, 이는 고주파영역에서의 PI와 PR 제어기의 성능을 비교해보면 알 수 있다. 이 논문에서 제시된 PR 제어기는 무한 이득을 교류 기본파 성분에 넣을 수 있기 때문에 PR 제어기는 회전좌표계의 PI 제어기에서 사용되는 디커플링 기법과 복잡한 변환 없이 제로 정상상태오차에 도달할 수 있다. 그렇기 때문에 이 논문에서는 PI 제어기를 대체하는 이론적 분석을 통해 PR 제어기를 설계하였다. 논문에 제시되어 있는 이론을 바탕으로 한 PR 제어기를 고정 소수점 연산방식의 32비트 마이크로컨트롤러 DSP320F2812를 기반으로 한 3kW 프로토타입 태양광 인버터에 적용, 평가하였다. 또한 태양광 인버터의 제어 성능을 시뮬레이션과 실험결과를 통하여 보여주고 검증하였다.

LTE와 IoT 기술을 이용한 스마트미터 데이터 전송장치와 전력 IT 시스템 (Smart meter data transmission device and power IT system using LTE and IoT technologies)

  • 강기범;김홍수;좌정우;김호찬;강민제
    • 한국산학기술학회논문지
    • /
    • 제18권10호
    • /
    • pp.117-124
    • /
    • 2017
  • 스마트 그리드는 기존 전력망에 ICT기술을 접목하여 소비자와 전력 공급자 간 양방향으로 실시간 정보를 교환함으로써 에너지를 효율적으로 사용 할 수 있는 시스템이다. 수요반응(DR, Demand response)은 전기사용자가 전력시장 가격이 높거나 전력계통 위기일 때 절약한 전기를 전력시장에 판매하여 금전으로 보상받는 제도이다. 본 논문은 스마트 미터(Smart Meter)를 사용하여 실시간으로 수요 정보를 계측하고 이를 클라우드 서버로 전송하는 전력량 계측 데이터 전송장치와 전력 IT 시스템을 개발하였다. 본 논문에서 개발된 전력량 계측 데이터 전송장치는 한국전력 데이터와 측정 오차가 없는 신뢰성이 있는 데이터를 제공하기 위해 Raspberry Pi 3에 연결된 빛 센서를 이용하여 한국전력 계측기의 전력량 단위마다 깜박이는 램프의 횟수를 계측한다. 전력량 계측 데이터 전송 장치는 표준 통신 프로토콜인 OpenADR 2.0b를 사용한다. 계측된 데이터는 LTE, WiFi 통신망을 통해 VEN, VTN, 계산 프로그램으로 구성되는 전력 IT 시스템의 MySQL DB에 저장된다. 개발된 전력량 계측 데이터 전송 장치는 전력계통 위기가 발생할 때 급전지시를 내려 피크감축 DR을 실행한다. 개발한 전력량 계측 데이터 전송 장치는 기존 스마트 미터링의 계측시간이 15분으로 고정되는 것과 달리 사용자가 1분 단위로 조절할 수 있는 장점을 갖는다.

클리어런스가 없는 초고압 회전용적형 헬리컬기어 펌프의 유동해석에 관한 연구 (A Study on Fluid Flow Analysis of High Pressure Positive Displacement Pump without Clearance)

  • 민세홍;김호철
    • 한국화재소방학회논문지
    • /
    • 제29권2호
    • /
    • pp.33-38
    • /
    • 2015
  • 고압과 정량 흡상을 목적으로 클리어런스가 없는 초고압 회전용적형 헬리컬기어 펌프의 개발을 진행하였다. 펌프의 내부 압력과 토출 유속을 검증하기 위해 CFD 해석을 수행하였다. 이에 따라 FVM 기법으로 유동해석을 수행하였는데 클리어런스가 없는 완전히 밀폐된 형태의 FVM 유동해석은 격자가 연속하게 구성되지 않아 유체영역이 분리되어 정상적인 결과를 얻어낼 수 없었다. 이러한 문제로 격자 구성이 필요치 않은 MPS 기법으로 유동해석을 수행하였고, MPS 유동해석을 통해 펌프의 내부 압력과 토출 유속을 확인할 수 있었다. 로터의 회전속도 1,000 rpm에서 펌프 내부의 압력은 최소일 때 19.5 bar, 최대일 때 44.6 bar이고, 평균 압력은 33.9 bar로 확인되었다. 토출 유속은 최소일 때 64.5 m/s, 최대일 때 84.8 m/s이고, 평균 유속은 76.1 m/s로 확인되었다. 본 연구를 통해 클리어런스가 없는 해석 모델의 유동해석은 FVM 기법보다는 MPS 기법이 더 적합하였음을 확인할 수 있었다. 또한 초고압 회전 용적형 헬리컬기어 펌프의 압력의 변화에 따른 유속과의 관계를 본 연구를 통해 규명할 수 있었다.

고정 그리드를 이용한 병렬 공간 조인의 태스크 할당에 관한 연구 (A Study on Task Allocation of Parallel Spatial Joins using Fixed Grids)

  • 김진덕;서영덕;홍봉희
    • 정보처리학회논문지D
    • /
    • 제8D권4호
    • /
    • pp.347-360
    • /
    • 2001
  • 공간 조인은 두 개의 데이터 집합으로부터 공간적인 조건을 만족하는 두 객체 쌍의 집합을 구하는 것으로 비용이 매우 큰 연산자이다. 지난 수년동안 공간 조인의 순차 수행 시간은 많이 향상되었지만, 그 응답시간은 사용자의 요구를 만족시키지 못하고 있다. 따라서 최근 병렬 시스템을 이용하여 이러한 문제를 해결하려는 연구가 진행되고 있다. 그렇지만 프로세서의 수가 증가할수록 병렬 처리에 의한 프로세서의 효율성은 급격히 떨어진다. 이것은 병렬 공간 조인을 수행할 경우 순차 공간 조인 보 다 디스크 병목 현상과 메시지 전송 오버헤드가 심하게 발생하기 때문이다. 이 논문에서는 공유 디스크 구조에서 다중 프로세서의 디스크 동시 접근으로 인한 병목 현상을 완화하고, 메시지 전송을 최소화하기 위한 태스크 할당 방법을 제안한다. 제안한 태스크 할당 방법을 두 가지 공간 조인 기법에 각각 적용하여 디스크 접근 횟수와 메시지 전송 횟수의 감소 효과를 실험으로 평가한다. MIMD 구조 및 공유디스크 방식의 병렬 시스템에서의 다양한 실험에서 이 논문에서 제안한 준동적 태스크 할당 방법이 정적 할당과 동적 할당 방법에 비해 우수함을 보였다.

  • PDF