• 제목/요약/키워드: Fixed Tip

검색결과 152건 처리시간 0.034초

다양한 자가조직을 활용한 비성형술 (Rhinoplasty using Various Autogenous Tissues)

  • 한기환;여현정;최태현;김준형;손대구
    • Archives of Plastic Surgery
    • /
    • 제37권1호
    • /
    • pp.37-45
    • /
    • 2010
  • Purpose: In Korean rhinoplasty, alloplasts such as silicone rubber have been used for dorsal and tip augmentations. However, alloplasts have produced complications such as deviation, exposure, and infection. Although autogenous tissue is an ideal material, the amount of the cartilage in Korean is not sufficient. Therefore, the authors developed a method to harvest the maximum amount of the septal and conchal cartilage. The authors first performed a complete septal extension graft for short and retruded columella and then performed nasal augmentation using various autogenous tissues. Methods: These surgical techniques were performed on 11 patients. Their average age was 27 years. An open approach with a V-shaped columellar labial incision was performed. At first, the complete septal extension graft was fixed on the entire caudal margin of the septum, and the alar cartilage was suspended to the septal extension graft to make the tip projected and the columella advanced caudally. A temporal fascial ball was used for radix augmentation. For dorsal augmentation, a batten-shaped septal cartilage graft wrapped with or without the temporal fascia or a diced cartilage graft wrapped with the temporal fascia was performed. For nasal tip augmentation, a shield graft and a cap graft or a folded conchal cartilage graft was performed.Results: The mean follow-up period was 11.2 months. The overall results were natural and satisfactory. Two patients underwent slight absorption and caudal displacement. With the exception of these cases, no complications were observed. Conclusion: Korean rhinoplastic surgeons are accustomed to using the alloplasts despite of serious complications. When rhinoplasty using autogenous tissue was performed, some complications occurred such as the displacement of the diced cartilage graft wrapped with the fascia, but many of the complications of alloplastic rhinoplasty were avoided. Therefore, we propose that by this time Korean rhinoplastic surgeons need to change their preference from alloplastic rhinoplasty to autogenous rhinoplasty.

Observational Evidence of Merging and Accretion in the Milky Way Galaxy from the Spatial Distribution of Stars in Globular Clusters

  • Chun, Sang-Hyun
    • 천문학회보
    • /
    • 제38권2호
    • /
    • pp.76-76
    • /
    • 2013
  • The current hierarchical model of galaxy formation predicts that galaxy halos contain merger relics in the form of long stellar streams. In order to find stellar substructures in galaxy, we focused our investigation on the stellar spatial density around globular clusters and on the quantitative properties of the evolved sequences in the color-magnitude diagrams (CMDs). First, we investigated the spatial configuration of stars around five metal-poor globular clusters in halo region (M15, M30, M53, NGC 5053, and NGC 5466) and one metal-poor globular cluster in bulge region (NGC 6626). Our findings indicate that all of these globular clusters show strong evidence of extratidal features in the form of extended tidal tails around the clusters. The orientations of the extratidal features show the signatures of tidal tails tracing the clusters' orbits and the effects of dynamical interactions with the galaxy. These features were also confirmed by the radial surface density profiles and azimuthal number density profiles. Our results suggest that these six globular clusters are potentially associated with the satellite galaxies merged into the Milky Way. Second, we derived the morphological parameters of the red giant branch (RGB) from the near-infrared CMDs of 12 metal-poor globular clusters in the Galactic bulge. The photometric RGB shape indices such as colors at fixed magnitudes, magnitudes at fixed colors, and the RGB slope were measured for each cluster. The magnitudes of the RGB bump and tip were also estimated. The derived RGB parameters were used to examine the overall behavior of the RGB morphology as a function of cluster metallicity. The behavior of the RGB shape parameters was also compared with the previous observational calibration relation and theoretical predictions of the Yonsei-Yale isochrones. Our results of studies for stellar spatial distribution around globular clusters and the morphological properties of RGB stars in globular clusters could add further observational evidence of merging scenario of galaxy formation.

  • PDF

Standardization of the Important Test Parameters in the Solder Ball Shear Test for Evaluation of the Mechanical Joint Strength

  • Kim J. W.;Koo J. M.;Lee W. B.;Moon W. C.;Moon J. H.;Yeon Y. M.;Shur C. C.;Jung S. B.
    • International Journal of Korean Welding Society
    • /
    • 제5권1호
    • /
    • pp.15-28
    • /
    • 2005
  • The ball shear test was investigated in terms of the effects of test parameters, i.e., shear height and shear speed, with an experimental and non-linear finite element analysis for evaluating the solder joint integrity of area array packages. Two representative Pb-free solder compositions were examined in this work: Sn-3.5Ag-0.75Cu and In-48Sn. The substrate was a common SMD type with solder bond pad openings of 460 $\mu$m in diameter. The microstructural investigations were carried out using SEM, and the IMCs were identified with EDS. Shear tests were conducted with the two varying test parameters. It could be observed that increasing shear height, at fixed shear speed, has the effect of decreasing shear force for both Sn-3.5Ag-0.75Cu and In-48Sn solder joints, while the shear force increased with increasing shear speed at fixed shear height. Too high shear height could cause some undesirable effects on the test results such as unexpected high standard deviation values or shear tip sliding from the solder ball. The low shear height conditions were favorable for screening the type of brittle interfacial fractures or the degraded layers in the interfaces. The shear speed conditions were discussed with the stress analyses of the solder ball, and we cannot find any conspicuous finding which is related to optimum shear speed from the stress analyses.

  • PDF

A study on the fracture strength of collarless metal-ceramic fixed partial dentures

  • Yoon, Jong-Wook;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yang, Jae-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권4호
    • /
    • pp.134-141
    • /
    • 2010
  • PURPOSE. The objective of this study was to evaluate fracture strength of collarless metal-ceramic FPDs according to their metal coping designs. MATERIALS AND METHODS. Four different facial margin design groups were investigated. Group A was a coping with a thin facial metal collar, group B was a collarless coping with its facial metal to the shoulder, group C was a collarless coping with its facial metal 1 mm short of the shoulder, and group D was a collarless coping with its facial metal 2 mm short of the shoulder. Fifteen 3-unit collarless metal-ceramic FPDs were fabricated in each group. Finished FPDs were cemented to PBT (Polybutylene terephthalate) dies with resin cement. The fracture strength test was carried out using universal testing machine (Instron 4465, Instron Co., Norwood MA, USA) at a cross head speed of 0.5 mm/min. Aluminum foil folded to about 1 mm of thickness was inserted between the plunger tip and the incisal edge of the pontic. Vertical load was applied until catastrophic porcelain fracture occurred. RESULTS. The greater the bulk of unsupported facial shoulder porcelain was, the lower the fracture strength became. However, there were no significant differences between experimental groups (P > .05). CONCLUSION. All groups of collarless metal-ceramic FPDs had higher fracture strength than maximum incisive biting force. Modified collarless metal-ceramic FPD can be an alternative to all-ceramic FPDs in clinical situations.

치아 및 임플랜트 지지 고정성 국소의치의 비고정성 연결부의 위치에 따른 유한요소법적 응력분석 (A FINITE ELEMENT STRESS ANALYSIS OF TOOTH AND IMPLANT SUPPORTED FIXED PARTIAL DENTURE ACCORDING TO THE LOCATION OF NON-RIGID CONNECTOR)

  • 안병주;황영필;계기성;조규종
    • 대한치과보철학회지
    • /
    • 제33권4호
    • /
    • pp.807-823
    • /
    • 1995
  • The purpose of this study was to analyze the stress distribution and the displacement happened to the abutment, the prosthesis, and the surrounding structure according to the location of the nonrigid connector, that is, the keyway in the distal of canine and the mesial of the implant in the three unit fixed partial denture. Two-dimensional finite element model ws constructed and analyzed for the stress distribution and the displacement using software ABAQUS(Ver 5.2 Hibbitt, Karisson & Sorenson, Inc., 1992). After finishing the finite element model, the distribution load of 15kg was applied simultaneously to the all cusp tips of the prosthesis and the concentration load of 10㎏ was applied respectively at the each cusp tip of the prosthesis. The following results were obtained : 1. The amount of displacement of the implant was greater in case of the non-rigid connection than the rigid connection, and the more favorable displacement was shown in case of the IKb than the IKa. 2. Without regard to the connection method, the stress represented at the surrounding bone was similar, and the more favorabel stress distribution was shown in case of IKb. 3. The maximum stress was concentrated at the fastening screw and the neck of implant in all experimental groups, and their stress magnitudes were in the order of IKb, IR, and IKa.

  • PDF

Buckling resistance, bending stiffness, and torsional resistance of various instruments for canal exploration and glide path preparation

  • Kwak, Sang-Won;Ha, Jung-Hong;Lee, WooCheol;Kim, Sung-Kyo;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • 제39권4호
    • /
    • pp.270-275
    • /
    • 2014
  • Objectives: This study compared the mechanical properties of various instruments for canal exploration and glide-path preparations. Materials and Methods: The buckling resistance, bending stiffness, ultimate torsional strength, and fracture angle under torsional load were compared for C+ file (CP, Dentsply Maillefer), M access K-file (MA, Dentsply Maillefer), Mani K-file (MN, Mani), and NiTiFlex K-file (NT, Dentsply Maillefer). The files of ISO size #15 and a shaft length of 25 mm were selected. For measuring buckling resistance (n = 10), the files were loaded in the axial direction of the shaft, and the maximum load was measured during the files' deflection. The files (n = 10) were fixed at 3 mm from the tip and then bent $45^{\circ}$ with respect to their long axis, while the bending force was recorded by a load cell. For measuring the torsional properties, the files (n = 10) were also fixed at 3 mm, and clockwise rotations (2 rpm) were applied to the files in a straight state. The torsional load and the distortion angle were recorded until the files succumbed to the torque. Results: The CP was shown to require the highest load to buckle and bend the files, and the NT showed the least. While MA and MN showed similar buckling resistances, MN showed higher bending stiffness than MA. The NT had the lowest bending stiffness and ultimate torsional strength (p < 0.05). Conclusions: The tested instruments showed different mechanical properties depending on the evaluated parameters. CP and NT files were revealed to be the stiffest and the most flexible instruments, respectively.

The xps study of the Cu-Zn nanofiber

  • Jeong, Eunkang;Kang, Yujin;Park, Juyun;Kang, Yong-Cheol
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.236.2-236.2
    • /
    • 2015
  • The copper-zinc(Cu-Zn) nanofiber was prepared by electrospinning method. The Cu/PVP (polyvinylpyrrolidone) and Zn/PVP precursor solutions were prepared by dissolution of copper sulfate and zinc acetate in methanol, respectively. The PVP was used to control the viscosity of the precursor solutions. The optimized ratio for the Cu/PVP and Zn/PVP nanofibers was determined separately. Then the suitable ratio of the precursor solutions was applied for fabrication of Cu/Zn/PVP nanofiber. For the electrospinning method, the precursor solutions were filled in a syringe. The distance between metallic needle on the syringe and collector was fixed at 16 cm and the voltage was applied on the tip was 13.0 kV. And the as-spun nanofiber was heated at 353K for removal of residual solvent. Then the heated nanofibers were calcined at 973K to decompose PVP. The obtained Cu, Zn, and Cu-Zn nanofibers were investigated with X-ray photoelectron spectroscopy (XPS) for the chemical properties, scanning electron microscopy (SEM) for the morphologies, and X-ray diffraction (XRD) to characterize the crystallinity and phase of nanofibers.

  • PDF

날개형상이 프로펠러형 수중믹서의 성능에 미치는 영향에 관한 수치적 연구 (A Numerical Study on the Effect of Blade Shapes on the Performance of the Propeller-type Submersible Mixers)

  • 최영석;이재환;김상일
    • 한국유체기계학회 논문집
    • /
    • 제3권2호
    • /
    • pp.31-35
    • /
    • 2000
  • In this research, the performance predictions of the submersible mixer were investigated. The variation of the performance characteristics by changing the impeller design parameters were discussed through the flow calculation results by using a commercial program, FLUENT. The performance of the submersible mixers is related to the velocity diffusion profiles downstream of the impeller and also the required input motor power to mix the fluid. In this study, the various design parameters such as the number of blade, the hub and tip diameters, the impeller blade profiles and revolution speed of the blades were taken for the fixed values. The blade sweep direction, the chord length distribution along with the radius of the blade and the inlet blade angle were changed to make different testing models. The flow calculation results show the effect of the changed design parameters on the performance of the submersible mixers and also give some helpful information for designing more efficient submersible mixers.

  • PDF

증기터빈 운전중 축 거동을 고려한 내부단 패킹실의 틈새 관리 (Control of Internal Packing Seal Clearances Considering for Shaft Behavior During Steam Turbine Operation)

  • 백민식;이시연;양보석;최성철;이재근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1715-1720
    • /
    • 2004
  • This paper presents the characteristics of internal clearances for the interstage of blades and shaft gland seals on the steam turbine which are installed in tandem compound. Internal clearances was changed when the rotor turned in the cylindrical sleeve bearing due to the generation of oil film wedge. This presented concern is very useful to prevent the rubbing damage of seal edge between the fixed and moving parts in steam turbine due to the misalignment at the rotating and stationary parts. This method is applied for the unbalanced clearances distribution to the left and right sides in the turbine casing. A considerable amount of unbalanced clearances distribution trend is determined according to the rotating speed of rotor, size and type of proceeding bearing, oil viscosity, surface roughness of bearing and shaft, oil temperature, oil pressure and bearing load.

  • PDF

비부 파라핀종의 제거와 동시에 시행한 자가진피지방이식을 이용한 융비술 (Secondary Augmentation Rhinoplasty with Immediate Autogenous Dermofat Graft after Removal of Paraffinoma)

  • 최강영;곽인수;조병채
    • Archives of Plastic Surgery
    • /
    • 제34권6호
    • /
    • pp.785-791
    • /
    • 2007
  • Purpose: Paraffin has been used to augment depressed nasal contour for many years by illegally. Reported complications of nasal paraffinoma were skin thinning, displacement of nasal profile, redness, chronic inflammation and malignant change to skin cancer. The current authors report results of the secondary rhinoplasty after excision of nasal paraffinoma. Methods: Through the open rhinoplasty incision, paraffinoma was removed under direct vision. Saline irrigation and meticulous hemostasis were performed. Simultaneously, the secondary depressed nasal deformity was corrected with autogenous dermofat graft harvested from inferior gluteal fold. The dermofat was fixed to the nasofrontal area with bolster suture, and the interdormal area of the tip. Results: A total of 13 patients underwent secondary augmentation with autogenous dermofat graft after removal of paraffinoma from 2000 to 2004. The mean follow-up period was 15 months. There were no postoperative complications. All patients were satisfied with their surgical results. However, there were 10 to 20 percent resorption of the grafted dermofat. Conclusion: It is suggest that autogenous dermofat be one of good materials for the correction of the secondary deformity after removal of nasal paraffinoma. In addition, autogenous dermofat graft presented easy harvesting and manipulation for transfer, high survival rate by firm fixation to the recipient site and stable surgical results.