• Title/Summary/Keyword: Fixed Sectional Method

Search Result 43, Processing Time 0.029 seconds

Circadian Rhythms Characteristics of Nurses Providing Direct Patient Care: An Observational Study

  • Ilknur Dolu;Serap Acikgoz;Ali Riza Demirbas;Erdem Karabulut
    • Safety and Health at Work
    • /
    • v.15 no.1
    • /
    • pp.102-109
    • /
    • 2024
  • Background: In today's modern world, longer working hours, shift work, and working at night have become major causes of the disruption of our natural circadian rhythms. This study aimed to investigate the effects of the type of shift work (rotating vs. fixed day), duty period (on-duty vs. off-duty), and working period within each shift (nighttime vs. daytime) on the circadian rhythm characteristics of nurses who provide direct patient care. Methods: This cross-sectional study used a purposive sampling method. Cosinor analysis was applied to analyze the actigraphy data of nurses providing direct patient care for seven consecutive days. The linear mixed effects model was then used to determine any variances between shift type, duty period, and working period within each shift for the nurses. Results: The mesor value did not differ according to nurses' shift type, duty period, and working period within each shift. The amplitude was statistically higher in on-duty nurses and in daytime working hours. The acrophase was significantly delayed in nighttime working hours. As well as nurses in rotating shift had experience. Conclusion: Our findings revealed that the peak activity of nurses occurs significantly later at night while working and nurses working during nighttime hours may have a weaker or less distinct circadian rhythm. Thus, this study suggests that limits be placed on the number of rotating nighttime shifts for nurses.

A Study on the Simple Design Method of Semi-Rigid Connection with Angle in Steel Structure (강구조에서 ㄱ형강을 이용한 반강접 접합의 간편 설계)

  • Heo, Myong-Jae;Kim, Hong-Geun;Choi, Won-Gu
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.3
    • /
    • pp.261-273
    • /
    • 2011
  • Recently, the demands for steel frame are increasing because of the trend and due to the demand for bigger and higher buildings. In the analysis of typical steel frame, connections are based on the idealized fixed or pinned connection. A fixed connection assumes that the relative angle of each member before deformation is the same after the transformation. Therefore, the stiffener reinforces the connection to sufficient rigidity and stability of the panel zone. In the economical aspect, however, the necessity of connection that the stiffener reinforcement has omitted is increasing due to the excessive production as well as labor costs of connection. In contrast, pinned connection is assumed that bending moments between the beams and columns do not transfer to each member. This is easy to make in the plant and the construction is simple. However, the structural efficiency is reduced in pinned connection because connection cannot transfer moments. The introduction of this semirigid process can decide efficient cross-sectional dimensions that promote ease in the course of structural erection, as performed by members in the field-a call for safety in the entire frame. Therefore, foreign countries exert efforts to study the practical behavior and the results are applied to criterion. This paper analyzes the semirigid connection of domestic steel by design specifications of AISC/LRFD and make data bank that pertain to each steel. After wards, the results are compared to those of idealized connection; at the same time, this paper presents a design method that matches economic efficiency, end-fixity, and rotational stiffness.

THREE DIMENTIONAL FORCE ANALYSIS OF FORCE SYSTEM IN CONTINUOUS ARCHWIRE BY FINITE ELEMENT METHOD (CONTINUOUS ARCHWIRE의 FORCE SYSTEM에 대한 3차원 유한 요소법적 연구)

  • Row, Joon;Ryu, Young-Kyu
    • The korean journal of orthodontics
    • /
    • v.26 no.1 s.54
    • /
    • pp.17-32
    • /
    • 1996
  • It is important to understand the operating mechanism and force system of fixed appliance that most effective for individual tooth movement in various orthodontic appliances. The archwire system of fixed appliance is devided into 3 types, which is continuous arch, segmented arch and sectional arch. The last two types have longer interbracket distance and simple force operating points, so it is easy to control force system by operator. But the continuous arch has shorter interbracket distance and various bracket geometry, so it is hard to control and anaylze the force system. The purpose of this study was three dimentional force and moment analysis of continuous arch system by finite element method, which is similar situation to three dimentional elastic beam in structural engineering. Several sample form of various bracket geometry and artificial lower crowding typodont made by author were constructed, analyzed and compared each other. The results were as follows : 1. The force magnitude is linear proportional to the degree of displacement or tilting of the bracket. 2. The force magnitude is inversely non-linear proportional to the interbracket distance. 3. In three dimensional typodont model, while the force can be compared with that of the sample form in the area where adjacent bracket geometry is simple, the force is much more than the expected value in the area where adjacent bracket geometry is complex.

  • PDF

The Determination of Critical Buckling Load Applied to Tapered Columns (일정변단면(一定變斷面) 장주(長柱)의 임계좌굴하중(臨界挫屈荷重)의 결정(決定))

  • Yu, Chul Soo;Sohn, Sung Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.1
    • /
    • pp.93-101
    • /
    • 1984
  • New formulas to determine the critical elastic buckling load of long tapered columns are given. This study is restricted to solid round or rectangular columns with fixed-free ends as often used in highway design. The exact solution of the differential equation of the deflection curve is expressed in terms of Bessel Function and the solution is numerically evaluated using Bisection method by computer. In the F.E.M analysis of columns under their own weight, the stability problem can be resulted in a eigen value problem of conservative system. Approximate solution by the F.E.M is evaluted numerically using Jacobi method and compared with exact solution of the prismatic column to increase the precision. In addition, critical buckling load of the tapered column for every shape factor and ratio of cross-sectional change (Diameter of bottom end/Diameter of upper end) was converted into a comparable expression to critical buckling load of the prismatic column.

  • PDF

Adaptive quantization for effective data-rate reduction in ultrafast ultrasound imaging (초고속 초음파 영상의 효과적인 데이터율 저감을 위한 적응 양자화)

  • Doyoung Jang;Heechul Yoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.422-428
    • /
    • 2023
  • Ultrafast ultrasound imaging has been applied to various imaging approaches, including shear wave elastography, ultrafast Doppler, and super-resolution imaging. However, these methods are still challenging in real-time implementation for three Dimension (3D) or portable applications because of their massive data rate required. In this paper, we proposed an adaptive quantization method that effectively reduces the data rate of large Radio Frequency (RF) data. In soft tissue, ultrasound backscatter signals require a high dynamic range, and thus typical quantization used in the current systems uses the quantization level of 10 bits to 14 bits. To alleviate the quantization level to expand the application of ultrafast ultrasound imaging, this study proposed a depth-sectional quantization approach that reduces the quantization errors. For quantitative evaluation, Field II simulations, phantom experiments, and in vivo imaging were conducted and CNR, spatial resolution, and SSIM values were compared with the proposed method and fixed quantization method. We demonstrated that our proposed method is capable of effectively reducing the quantization level down to 3-bit while minimizing the image quality degradation.

Studies on the Phrenic Nerve Fibers in the dog II. On the Myelinated Fibers of the Intradiaphragmatic Branches (개의 횡격막신경섬유(橫隔膜神經纖維)에 관(關)한 연구(硏究) 제(第)II보(報) 횡격막신경(橫隔膜神經)의 횡격막내분기(橫隔膜內分技)의 유수섬유(有髓纖維)에 관(關)하여)

  • Ko, Kwang Doo;Yoon, Suk Bong;Lee, Joon Sup
    • Korean Journal of Veterinary Research
    • /
    • v.9 no.1
    • /
    • pp.1-9
    • /
    • 1969
  • The experimental studies were performed to observe the characteristics of the myelinated nerve fibers of the tradiaphragmatic branches of phrenic nerves in dog In the work to be reported five mixed breed Korean dog were used, they were one year old and he body eights were about 12 Kgm. in average with healthy conditions. The specimens (nerve) were taken at the point of 1.5 cm posterior part from the left and right phrenic nerves entrance to the diaphragm, and the dorso-lateral and dorso-medial branches of phrenic nerves vere also, taken at the point of 0.5 cm distal part from their branching portion. The specimens were fixed for 24 hrs. in Flemming's solution, and embedded in paraffin. The paraffin section. were cut at 6 microns and stained with Walter's modification of Weigert-pal method for the myelinated fibers. Microphotographs were taken and enlarged into 750 times of the actual size, and the diameter of the photographic images of the myelinated fibers were measured by the scale on the transparent Percepex Plate. The following conclusions were made: 1. The percentage of distribution of the several intradiaphragmatic branches of phrenic nerves were as follows. Ventral branches were 34.97%, lateral branches were 37.90%, dorsal branches were 27.13%, and the dorsal branches were branched again into dorso-lateral branches(54.22%) and dorso-medial branches (45. 78%). 2. The mean value and S.D. of the total numbers of the myelinated nerve fibers at the left ventral branches were $490.80{\pm}12$, and at the right ventral branches were $486.6{\pm}13$. Total average cross sectional area on the left ventral branches were 38,000. $6{\pm}136{\mu}^2$, and the right ventral branches were $37,150.2{\pm}1.782{\mu}^2$. 3. The mean value and S.D. of the total numbers of the myelinated nerve fibers at the left lateral branches were $533.8{\pm}8$, and at the right lateral branches were $525.6{\pm}7$. Total average cross sectional area of the left lateral branches were $41,582{\pm}1,170{\mu}^2$, and the right lateral branches were $40,454.8{\pm}812{\mu}^2$. 4. The mean value and S.D. of the total numbers of the myelinated nerve fibers at the left dorsal branches were $378.2{\pm}14$, and at the right dorsal branches were $380.2{\pm}8$. Total average cross sectional area of the left dorsal branches were $27,771{\pm}1,256{\mu}^2$, and the right dorsal branches were $27,507.2{\pm}645{\mu}^2$. 5. The mean value and S.D. of the total numbers of the myelinated fibers at the left dorso-lateral branches were $205.4{\pm}15$, and at the right dorso-lateral branches were $210.6{\pm}17$. Total average cross sectional area of the left dorso lateral branches were $15,354. 8{\pm}1,519{\mu}^2$, and the right dorsal branches were $15,887{\pm}1,297{\mu}^2$. 6. The mean value and S.D. of the total numbers of the myelinated nerve fibers at the left dorso-medial branches were $175{\pm}14$, and at the right dorso-medial branches were $176.2{\pm}17$. Total average cross sectional area of the left dorso-medial branches were $13,037.4{\pm}944{\mu}^2$, and at the right dorso-medial branches were, $13,103{\pm}1,373{\mu}^2$. 7. The highest frequent distribution of the intradiaphragmatic branches of phrenic nerves were found in the $10-12{\mu}^2$ groups, and they were almost 30% of the total groups. 8. The largest fibers diameter were in the $14-16{\mu}^2$ groups, and these were shown the lowest frequent distribution. 9. The largest cross sectional area of the intradiaphragmatic branches of phrenic nerves were found in the $10-12{\mu}^2$ groups. 10. All of the intradiaphragmatic branches of phrenic nerves were unimodal which has a peak in the $10-12{\mu}^2$ groups.

  • PDF

Analysis for Characteristics Method on Wind Pressure of Trains Crossing in Tunnel (터널내 교행 열차의 풍압에 대한 특성법 해석)

  • Nam, Seong-Won
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.6
    • /
    • pp.454-459
    • /
    • 2013
  • Pressure waves are generated and propagate in a tunnel when train enters tunnel high speed. A compression wave due to the entry of train head propagates along the tunnel and is reflected at tunnel exit as an expansion wave. An expansion wave due to the entry of the train tail propagates along the tunnel and is reflected at tunnel exit as a compression wave. These pressure waves are repeatedly propagated and reflected at the tunnel entrance and exit. Severe pressure changes causes ear-discomfort for passengers in the cabin and micro pressure waves around the tunnel exit. It is necessary to analyze the transient pressure phenomena in tunnels qualitatively and quantitatively, because pressure change rate is considered as one of the major design parameters for optimal tunnel cross sectional area and repeated fatigue force on car body. In this study, we developed a characteristics method based on a fixed mesh system and boundary conditions for crossing trains and analyzed this system using an X-t diagram. The results of the simulation show that offsetting of pressure waves occurs for special entry conditions of a crossing train.

Characteristics Method Analysis of Wind Pressure of Train Running in Tunnel (터널을 주행하는 열차의 풍압에 대한 특성해법 해석)

  • Nam, Seong-Won;Kwon, Hyeok-Bin;Yun, Su-Hwan
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.5
    • /
    • pp.436-441
    • /
    • 2012
  • Pressure waves are generated and propagate in tunnel when train enters a tunnel with high speed. Compression wave due to the entry of train head propagates along the tunnel and is reflected at tunnel exit as expansion wave. While expansion wave due to the entry of train tail propagates along the tunnel and is reflected at tunnel exit as compression wave. These pressure waves are repeatedly propagated and reflected at tunnel entrance and exit. Severe pressure change per second causes ear-discomfort for passengers in cabin and micro pressure wave around tunnel exit. It is necessary to analyze the transient pressure phenomena in tunnel qualitatively and quantitatively, because pressure change rate is considered as one of major design parameters for an optimal tunnel cross sectional area and the repeated fatigue force on car body. In this study, we developed the characteristics method analysis based on fixed mesh system and compared with the results of real train test. The results of simulation agreed with that of experiment.

Characteristics of the Flow and Heat Transfer around a Wavy Cylinder (파형 실린더 주위의 유동 및 열 전달 특성)

  • Lee, Chang-Yeol;Seo, Jang-Hoon;Hung, Pham-Anh;Yoon, Hyun-Sik;Chun, Ho-Hwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.46 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • Three-dimensional characteristics of fluid flow and heat transfer around a wavy circular cylinder having sinusoidal variation in cross sectional area along the spanwise direction are numerically investigated using the immersed boundary method. The three different wavelengths of ${\pi}4$, ${\pi}3$ and ${\pi}2$ at the fixed wavy amplitude of 0.1 have been considered to investigate the effects of waviness especially on the forced convection heat transfer around a wavy cylinder when the Reynolds and Prandtl numbers are 300 and 0.71, respectively. The present computational results for a wavy cylinder are compared with those for a smooth cylinder. The time- and total surface-averaged Nusselt number for a wavy cylinder with ${\lambda}={\pi}/2$ is larger than that for a smooth cylinder, whereas that with ${\lambda}={\pi}/4$ and ${\pi}/3$ is smaller than that for a smooth cylinder. However, because the surface area exposed to heat transfer for a wavy cylinder is larger than that for a smooth cylinder, the total heat transfer rate for a wavy cylinder with different wavelengths of ${\lambda}={\pi}/4$, ${\pi}/3$ and ${\pi}/2$ is larger than that for a smooth cylinder.

Prevalence and risk indicators of peri-implantitis in Korean patients with a history of periodontal disease: a cross-sectional study

  • Goh, Mi-Seon;Hong, Eun-Jin;Chang, Moontaek
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.4
    • /
    • pp.240-250
    • /
    • 2017
  • Purpose: The aim of this study was to analyze the prevalence and risk indicators of peri-implantitis in Korean patients with history of periodontal disease. Methods: A total of 444 patients with 1,485 implants were selected from patients who had been treated at the Department of Periodontology, Chonbuk National University Dental Hospital between July 2014 and June 2015. A group with a history of peri-implantitis (HP) (370 patients with 1,189 implants) and a group with a current peri-implantitis (CP) (318 patients with 1,004 implants) were created based on the radiographic and clinical assessments of implants. The prevalence of peri-implantitis was calculated at both the patient and implant levels. The influence of risk variables on the occurrence of peri-implantitis was analyzed using generalized estimating equations analysis. Results: The prevalence of peri-implantitis in the HP and CP groups ranged from 6.7% to 19.7%. The cumulative peri-implantitis rate in the HP group estimated with the Kaplan-Meier method was higher than that in the CP group over the follow-up period. Among the patient-related risk variables, supportive periodontal therapy (SPT) was the only significant risk indicator for the occurrence of peri-implantitis in both groups. In the analysis of implant-related variables, implants supporting fixed dental prosthesis (FDP) and implants with subjective discomfort was associated with a higher prevalence of peri-implantitis than single implants and implants without subjective discomfort in the HP group. The presence of subjective discomfort was the only significant implant-related variable predictive of peri-implantitis in the CP group. Conclusions: Within the limitations of this study, the prevalence of peri-implantitis in Korean patients with a history of periodontal disease was similar to that reported in other population samples. Regular SPT was important for preventing peri-implantitis. Single implants were found to be less susceptible to peri-implantitis than those supporting FDP. Patients' subjective discomfort was found to be a strong risk indicator for peri-implantitis.