• Title/Summary/Keyword: Fixed Grid System

Search Result 121, Processing Time 0.033 seconds

KOMPSAT EOC Grid Reference System

  • Kim, Youn-Soo;Kim, Yong-Seung;Benton, William
    • Proceedings of the KSRS Conference
    • /
    • 1998.09a
    • /
    • pp.349-354
    • /
    • 1998
  • The grid reference system (GRS) has been useful for identifying the geographical location of satellite images. In this study we derive a GRS for the KOMPSAT Electro-Optical Camera (EOC) images. The derivation substantially follows the way that SPOT defines for its GRS, but incorporates the KOMPSAT orbital characteristics. The KOMPSAT EOC GRS (KEGRS) is designed to be a (K,J) coordinate system. The K coordinate parallel to the KOMPSAT ground track denotes the relative longitudinal position and the J coordinate represents the relative latitudinal position. The numbering of K begins with the prime meridian of K=1 with K increasing eastward, and the numbering of J uses a fixed value of J=500 at all center points on the equator with J increasing northward. The lateral and vertical intervals of grids are determined to be 12.5 km about at the 38$^{\circ}$ latitude to allow some margins for the value-added processing. The above design factors are being implemented in a satellite programming module of the KOMPSAT Receiving and Processing System (KRPS) to facilitate the EOC data collection planning over the Korean peninsula.

  • PDF

The Design of the Drawing Management on Smart Operating Environments (스마트 운영 환경에서의 도면 관리기의 설계)

  • Kim, Dong-Hyun;Park, Min-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.223-226
    • /
    • 2011
  • To design a drawing at construction sites or ship yards, generally, they exploit CAD program, such as AutoCAD. They also carry the printed drawings in the fields in order to refer the designs. However, the printed designs are easy to be damaged. In this paper, we propose the design of a management system for the CAD drawings on top of the smart operating systems of a smart device. The proposed system exploits the index file based on the Fixed GRID file in order to improve the display speed of the drawings.

  • PDF

Stabilization of Fixed Speed Wind Generator by using Variable Speed PM Wind Generator in Multi-Machine Power System

  • Rosyadi, Marwan;Takahashi, Rion;Muyeen, S.M.;Tamura, Junji
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.1
    • /
    • pp.111-119
    • /
    • 2013
  • This paper present stabilization control of fixed speed wind generator by using variable speed permanent magnet wind generator in a wind farm connected with multi-machine power system. A novel direct-current based d-q vector control technique of back to back converter integrated with Fuzzy Logic Controller for optimal control configuration is proposed, in which both active and reactive powers delivered to a power grid system are controlled effectively. Simulation analyses have been performed using PSCAD/EMTDC. Simulation results show that the proposed control scheme is very effective to enhance the voltage stability of the wind farm during fault condition.

PSCAD/EMTDC BASED MODELING AND ANALYSIS OF A GRID-CONNECTED VARIABLE SPEED WIND ENERGY CONVERSION SCHEME (계통연계형 가변속 풍력발전방식의 PSCAD/EMTDC 모의 및 해석)

  • 김슬기;김응상
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.8
    • /
    • pp.413-419
    • /
    • 2003
  • The paper presents a simulation model and analysis of a grid-connected variable speed wind energy conversion scheme (VSWECS) using the PSCAD/EMTDC software. The modeled system uses a variable speed drive, a fixed pitch angle, a synchronous generator as a wind generator and an AC-DC-AC conversion scheme, which facilitates the wind generation to efficiently operate under varying wind speed while connected to the distribution network. The power output of the WECS is controlled by the AC-DC-AC conversion scheme, the objective of which is to capture the maximum active power under varying wind conditions and to keep the voltage magnitude of the terminal bus at a specific level. Aerodynamic models are applied for a wind turbine model. An simulation analysis of the scheme in terms of its responding to wind variations is also presented.

Comparison of Characteristics for Variable Operation using Doubly-fed Induction Generator and Fixed Speed Operation in Wind Turbine System (이중여자 유도발전기를 이용한 가변속운전과 정속운전 풍력발전시스템의 운전특성 비교)

  • Ro, Kyoung-Soo;Kim, Tae-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1313-1320
    • /
    • 2009
  • This paper analyzes the steady-state operating characteristics of doubly-fed induction generator(DFIG) and fixed-speed induction generator(FSIG) in wind turbine system. It also presents a modeling and simulation of a grid-connected wind turbine generation system for dynamics analysis on MATLAB/Simulink, and compares the responses between DFIG and FSIG wind turbine systems with respect to wind speed variation, 3-phase fault and 1-phase ground fault of the network. Simulation results show the variations of generator's active/reactive output, rotor speed, terminal voltage, fault current, etc. Case studies demonstrate that DFIG illustrates better performance compared to FSIG.

Numerical Simulation on the Greenwater Impact Load of Offshore Structure in Regular Waves (규칙파 중 해양구조물의 갑판침입수 충격하중에 관한 수치시뮬레이션)

  • Kang, Ui-Ha;Lee, Young-Gill;Yang, In-Jun;Kim, Ki-Yong;Joo, Young-Seok;Park, Jeong-Ho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.6
    • /
    • pp.492-500
    • /
    • 2017
  • In the study, numerical simulation on the greenwater impact load of free surface offshore structure in the regular waves using fixed cartesian grid system and Modified Marker-Density (MMD) method were carried out and the results were reviewed. In order to compare numerical simulation and experimental results, the FPSO with the scale ratio of 1/100 model ship with fixed rectangular deck was selected and turbulence characteristic of the flow was considered by applying the Sub-Grid Scale (SGS) in laminar flow. As a result, it is reviewed how the greenwater impact load inflowed from bow in regular headsea wave influence the flow on the deck and the flow characteristic by numerical simulation and the experiment results were compared and reviewed. Based on this study, it would be useful to numerically study the effect of greenwater on offshore structure.

Coordinated Voltage Control of DFIG to Overcome Shortcomings of FSIG in Wind Turbine System (FSIG 풍력발전의 특성개선을 위한 DFIG의 협조 전압제어)

  • Minh Quan, Duong;Ro, Kyoung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.704-705
    • /
    • 2011
  • At present, the widely used wind power generators in the whole world are fixed speed induction generator (FSIG) and doubly fed induction generator (DFIG). The models of FSIG and DFIG wind power generation system connected with the grid are built, and their steady-state and transient characteristics are studied. A new coordinated control strategy using both the grid and rotor side converters of DFIG for voltage regultation and reactive power support is put forword to improve the steady-state and transient performance of the FSIG in the case of DFIG in parallel with FSIG.

  • PDF

Modeling of Grid-connected Wind Energy Conversion System Using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 계통연계형 풍력발전시스템 모델링)

  • Kim, Seul-Ki;Kim, Eung-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.320-322
    • /
    • 2002
  • The paper presents an electrical model of a grid-connected wind energy conversion system (WECS) with a variable speed drive, a fixed pitch angle, a synchronous generator as a wind generator and AC-DC-AC conversion scheme for simulating dynamic behaviors and performance responding to varying wind speed input. The electric output of the WECS is controlled by the AC-DC-AC conversion scheme, the objective of which is to capture the maximum active power under varying wind conditions and to keep the voltage of WECS terminal bus at a specific level. Aerodynamic models are used to incorporate the power characteristics to wind speed. The modeling and simulation of the WECS are realized on PSCAD/EMTDC environment.

  • PDF

Control of 30kW Grid-Connected PCS for Wave Power Generation (파력발전용 30kW 계통연계형 PCS 제어)

  • Kim, Wan-Seok;Kim, Jae-Hyuck
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.470-475
    • /
    • 2019
  • This paper deals with a 30kW grid-connected PCS (Power Conversion System) for an Oscillating Water Column (OWC) wave-power generation system. Wave power generation in marine energy is suitable for Korea with the characteristics of a peninsula with three sides facing the sea. In the case of coastal disasters, wave generators can act as a breakwater to reduce damage, and can be integrated with other marine power generation systems to increase efficiency. Wave power generation systems are classified into various types, such as oscillating bodies, OWC, and overtopping according to the operation principle, and they can also be classified into two types according to the installation method: a fixed structure and floating structure. This paper proposes a 30kW grid-connected PCS topology and model for OWC wave power generation that is structurally stable with a turbine and generator that are relatively easy to maintain, and then provide a control method required for grid connection, including DC link voltage control. Simulation verification was performed to verify the proposed PCS.

Comparison of Squirrel cage and Wound induction generator characteristics in Wind Power System (농형 유도발전기와 권선형 유도발전기의 특성비교)

  • Kim, Chan-Ki;Lee, Won-Kyo;Im, Cheol-Kyu
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.469-471
    • /
    • 2005
  • Wind farms employs induction generators which are two type, one is Squirrel cage for fixed speed wind turbines and the other is Wound induction generator (doubly fed induction generator DFIG) for variable speed wind turbines. this paper describes grid connection scheme of wind power system using two type induction generators and simulation results show the characteristics of two type induction generators.

  • PDF