• Title/Summary/Keyword: Fixed Grid System

Search Result 121, Processing Time 0.024 seconds

Study on the Radiation Forces on a Pontoon Type Floating Structure and Submerged Plate : Hydrodynamic Interaction Effect by Submerged Plate (폰툰형 부체구조물과 몰수평판에 작용하는 라디에이션 유체력에 관한 연구 : 몰수평판에 의한 유체력 간섭 영향)

  • Lee, Sang-Min
    • Journal of Navigation and Port Research
    • /
    • v.31 no.8
    • /
    • pp.683-687
    • /
    • 2007
  • Hydroelastic deformation of pontoon type floating structure in waves is critical in structural design. Therefore, it is necessary to develop additional technology that make to dissipate the wave energy as the submerged horizontal plate. In this study, we investigate the characteristics of hydrodynamic interaction effect by the submerged plate affecting to the radiation forces on a pontoon type floating structure using numerical analysis. We have developed the numerical method based on the composite grid system that consists of moving and fixed grid to compute the radiation forces due to the heaving motion of pontoon type floating structure and submerged plate. The numerical simulations based on the finite difference method are carried out to solve the fully nonlinear free surface involving the breaking waves and compared with the experimental data to confirm the reliability of the numerical method. Then, we discuss the interaction effects on the hydrodynamic forces that could influence on the hydroelastic response of floating structure.

Design of Robust Adaptive Fuzzy Controller for Uncertain Nonlinear System Using Estimation of Bounding Constans and Dynamic Fuzzy Rule Insertion (유계상수 추정과 동적인 퍼지 규칙 삽입을 이용한 비선형 계통에 대한 강인한 적응 퍼지 제어기 설계)

  • Park, Jang-Hyun;Park, Gwi-Tae
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.1
    • /
    • pp.14-21
    • /
    • 2001
  • This paper proposes an indirect adaptive fuzzy controller for general SISO nonlinear systems. In indirect adaptive fuzzy control, based on the proved approximation capability of fuzzy systems, they are used to capture the unknown nonlinearities of the plant. Until now, most of the papers in the field of controller design for nonlinear system considers the affine system using fuzzy systems which have fixed grid-rule structure. We proposes a dynamic fuzzy rule insertion scheme where fuzzy rule-base grows as time goes on. With this method, the dynamic order of the controller reduces dramatically and an appropriate number of fuzzy rules are found on-line. No a priori information on bounding constants of uncertainties including reconstruction errors and optimal fuzzy parameters is needed. The control law and the update laws for fuzzy rule structure and estimates of fuzzy parameters and bounding constants are determined so that the Lyapunov stability of the whole closed-loop system is guaranteed.

  • PDF

Data Transmission Rate Improvement Scheme in Power Line Communication System for Smart Grid (스마트 그리드를 위한 전력선 통신 시스템에서의 데이터 전송률 향상 기법)

  • Kim, Yo-Cheol;Bae, Jung-Nam;Kim, Yoon-Hyun;Kim, Jin-Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.12B
    • /
    • pp.1183-1191
    • /
    • 2010
  • In this paper, I propose an adaptive OFDM CP length algorithm for in PLC systems for smart grid. The proposed scheme calculates the channel delay information at the CP controller of the receiver by taking correlation between a received data frame and the following delayed one. The CP controller, immediately, feeds back the channel delay information to the transmitter. Then, the transmitter adapts CP length for next data frame. As an impulsive noise model, Middleton Class A interference model was employed. The performance is evaluated in terms of packet data rate, cumulative packet data rate, and bit error rate (BER). The simulation results showed data gain (which is the amount of the reduced bits) gets larger as the number of packets increase, but the amount of data gain reduced as the number of branches ($N_{br}$) increase. In respects of BER for the cases $N_{br}$ is 3, 4, and 5, performance of the adaptive CP length algorithm and the fixed CP scheme are similar. Therefore, it is confirmed the proposed scheme achieved data rate increment without BER performance reduction compared to the conventional fixed CP length scheme.

Single-Phase Utility-Interactive Inverter for Residential Fuel Cell Generation System (가정용 연료전지 발전 시스템을 위한 단상 계통연계형 인버터)

  • Jung, Sang-Min;Bae, Young-Sang;Yu, Tae-Sik;Kim, Hyo-Sung;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.81-88
    • /
    • 2007
  • In this paper, a new single-phase utility-interactive inverter system for residential power generation with fuel cell is proposed. The proposed inverter system is not only capable of working in both stand-alone and grid-connected mode, but also ensures smooth and automatic transfer between the two modes of operation. The proposed control method has little steady-state error and good transient response characteristic. Also, the control method can be implemented using low-cost, fixed point DSP since it has simpler structure, smaller amount of calculation, and smaller number of sensors. The controller for the proposed utility-interactive inverter system is described, and the validity is verified through simulation and experiment.

Study of geometric effects on vortex breakdown in a rotating axisymmetric circular cylinder (회전하는 축 대칭 원통형 용기에서의 기하학적 영향에 따른 와동붕괴에 관한 연구)

  • Kim Jae Won;Kim Nam Wook;Byun Sam Mon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.03a
    • /
    • pp.35-41
    • /
    • 2004
  • A numerical investigation has been made for flows in an axisymmetric circular cylinder with a rotating cone located at the bottom of the container. The axisymmetric container is completely filled with a viscous fluid. Major parameter for the present research is the vertex angle of the cone, otherwise Reynolds number of fluid and aspect ratio of the vessel is fixed. Main interest is in vortex breakdown of meridional circulation by rotation of the cone with respect to the longitudinal axis of the cylinder. The method to this problem is numerically to integrate momentum and continuity equations on a generalized body fitted grid system. The pattern of vortex breakdown is quite different from that in a right circular cylinder with flat end wall disks. Flow visualization photographs of a preceeding work are compared with the present numerical results.

  • PDF

A Study on the Variation of Power Factor by Connection of the Induction Generator to the Distribution Line (배전선로에 유도발전기 연결시 역률 변동에 관한 연구)

  • Kim, Jong-Gyeum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.3
    • /
    • pp.159-163
    • /
    • 2015
  • Recently squirrel cage induction generator has been steadily applied to many small hydro power plants. Induction generator needs a reactive power for magnetization. The reactive power of induction generator is being supplied from the supply side mostly. The use of induction generators in the power distribution grid can affect the power factor. The power factor of induction generator is fixed already during production. The power factor in the distribution system is due to the increase or decrease of the load rather than due to the induction generator. In this study, we analyzed that how the increase or decrease of D/L load impacts at the change of power factor and power flow.

A study on the variation of power factor by connection of the induction generator to the distribution line (배전선로에 유도발전기 연결시 역률 변동에 관한 연구)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Kyung-Bae;Kim, Young-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1469-1470
    • /
    • 2015
  • Recently induction generator has been applied to many small hydro power plants. Induction generator needs a reactive power for magnetization. The reactive power of induction generator is being supplied from the supply side mostly. The use of induction generators in the power distribution grid can affect the power factor. The power factor of induction generator is fixed already during production. The power factor in the distribution system is due to the increase or decrease of the load rather than due to the induction generator. In this study, we analyzed how the power factor is changed according to the load increase or decrease in the distribution lines.

  • PDF

Numerical Study on The Injection-Compression Molding Characteristic of High Viscosity Plastic Fluids (고점도 유동장이 사출-압축 성형에 미치는 영향)

  • Park, Gyun-Myoung;Kim, Chung-Kyun
    • Tribology and Lubricants
    • /
    • v.18 no.5
    • /
    • pp.345-350
    • /
    • 2002
  • Recently, as the development of manufacturing technique on SMC(sheet molding compound), various numerical and experimental approaches to injection and compression molding have been investigated. Injection and compression molding, however, has so various cases with complicated boundary condition that it is difficult to analyze mold characteristics precisely. In addition, since a slight change in process variables can significantly change the resulting mold thickness, a proper design is important to compression molding process. Therefore, in this study, the effects of various parameters on compression molding process have been investigated using FEM(finite element method) to formulate the melt front advancement during the mold filling process. To verify the results of present analysis, they are compared with those of reference. The results show a strong effect of initial charge volume, injection time and pressure as a result of variations in the rectangular charge shape.

Effect of domain size on flow characteristics in simulating periodic obstacle flow (주기적인 경계조건을 사용하는 수치모사에서 계산영역 크기의 영향)

  • Choi, Choon-Bum;Jang, Yong-Jun;Han, Seok Youn;Kim, Jin-Ho;Yang, Kyung-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2477-2482
    • /
    • 2008
  • Effect of computational domain size in simulating of periodic obstacle flow has been investigated for the flow past tube banks. Reynolds number, defined by freestream velocity (U) and cylinder diameter (d), was fixed as 200, and center-to-center distance (P) as 1.5d. In-line square array was considered. Drag coefficient, lift coefficient and Strouhal number were calculated depending on domain size. Circular cylinders were implemented on a Cartesian grid system by using an immersed boundary method. Boundary condition is periodic in both streamwise and lateral directions. Previous studies in literature often use a square domain with a side length of P, which contains only one cylinder. However, this study reveals that size is improper. Especially, RMS values of flow-induced forces are most sensitive to the domain size.

  • PDF

Design of a Microcontroller Based Electronic Load Controller for a Self Excited Induction Generator Supplying Single-Phase Loads

  • Gao, Sarsing;Murthy, S. S.;Bhuvaneswari, G.;Gayathri, M. Sree Lalitha
    • Journal of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.444-449
    • /
    • 2010
  • The generation of electric power using self excited induction generation (SEIG) is a viable option in remote and rural areas where grid electricity is not available. The generated voltage and frequency of these machines, however, varies with varying loads. This characteristic can be resolved either by adjusting the values of the excitation capacitance or by controlling the prime mover speed. Further, in a single-point constant power application, where the machines deliver a fixed amount of power, the electronic load controller (ELC) can be used to switch-in or switch-out a dump load whenever the consumer load decreases or increases respectively. This paper presents a detailed analysis and the design of a microcontroller based SEIG -ELC system intended for stand-alone pico hydro power generation. The simulated performance of the controller is supplemented by experimental results.