• Title/Summary/Keyword: Fixation of femoral fracture

Search Result 46, Processing Time 0.024 seconds

Modified External Skeletal Fixation for Craniodorsal Coxofemoral Luxation in 5 Dogs (개의 전배측 고관절 탈구에서 변형된 외골격 고정 적용 5례)

  • Jung, Chang-Su;Lim, Ji-Hey;Byeon, Ye-Eun;Kim, Wan-Hee;Yoon, Jung-Hee;Kweon, Oh-Kyeong
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.631-635
    • /
    • 2007
  • Luxation of the hip is the most common luxation seen in small animals. Luxations are classified by the direction in which the femoral head lies in relation to the acetabulum and craniodorsal luxations are the most common type. Recommendations for treatment are based on the presence of preexisting disease, the type and duration of luxation and severity of concurrent injuries. In this study modified external skeletal fixation was used for craniodorsal coxofemoral luxation in 5 dogs. Luxated head Joint was reduced and fixator pins were applied into the greater trochanter, the middle point of iliac body and the lateral surface of sacroiliac joint in a closed fashion. Reduction was successful in 4 of the 5 operated limbs. Complications noted in this study included pin tract drainage, pin loosening and secondary fracture at the pin insertion site.

A Clinical Study of Femur Neck Fractures (대퇴 경부 골절의 임상적 고찰)

  • Koo, Hwan-Mo;Ahn, Myun-Whan;Ihin, Joo-Choul
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.1
    • /
    • pp.69-80
    • /
    • 1990
  • A clinical analysis was done on 23 patients(24 hips) with fracture of the femoral neck, who had been admitted and treated at our Orthopedic department during the period of 4 years, from Jan, 1984 to May 1988. The results were as follows : 1. 23 patients were comprised of 4 males and 19 females, and 11 patients were over 65 years old. 2. 18 cases of 24 cases were due to minor traumas such as slipping down, and for over 65 years old, all cases were due to simple minor traumas, 8 cases were showed a severe osteoporosis, below grade 3 of the Singh's index. 3. 14 cases of 24 cases were displaced subcapital fractures, and 6 cases displaced transcervical fractures. Only 4 cases were the undisplaced transcervical fractures. 4. In treatment of fractures internal fixations after manipulation were performed in 14 cases and primary arthroplasties in 10 cases. Secondary arthroplasties were done in complicated 4 cases of 14 cases treated with internal fixations. 5. Complications after internal fixation were developed in 7 cases out of 14 cases, avascular necrosis in 6, nonunions in 2, pin migrations in 3, and metal failure in 1 case. 6. In 14 arthroplasty immediate surgical fitness of femoral stem were related to late loosening of femoral stem(correlation coefficient r=-0.68, p<0.01).

  • PDF

Adult Proximal Humeral Locking Plate Is a Good Alternative Option in the Treatment of Adolescent Subtrochanteric Femur Fractures: A Case Series and Literature Review

  • Ceyhun Caglar;Serhat Akcaalan;Merve Bozer;Mustafa Akkaya
    • Hip & pelvis
    • /
    • v.34 no.4
    • /
    • pp.245-254
    • /
    • 2022
  • Purpose: Management of pediatric subtrochanteric femur fractures (SFFs) is difficult. The aim of this study was to evaluate the outcomes of adolescent SFFs treated with adult proximal humeral locking plates (PHLPs). Materials and Methods: A retrospective analysis of 18 adolescents (11 male, 7 female) with a diagnosis of SFF who underwent internal fixation with a PHLP was conducted. Data regarding injury mechanism, fracture pattern, and time to union were recorded for all patients. In addition, a clinical and functional evaluation of patients was performed using the Harris hip score (HHS), Iowa hip score (IHS), modified Merle d'Aubigne-Postel score (MMAPS), Flynn criteria, and hip range of motion (ROM). Results: The mean age of the patients was 12.72±2.05 years (range, 10-16 years). Radiological observation was performed for evaluation of five different injury mechanisms and different fracture patterns in patients. The mean postoperative HHS was 92.27±5.61, the mean IHS was 90.88±6.46, and the mean MMAPS was 17.22±0.94. According to the Flynn criteria, excellent results were achieved in 14 cases and satisfactory results were obtained in four cases. Measurements of the patients' mean hip ROM values were as follows: 17.77±3.52° in extension, 115.27±6.74° in flexion, 43.05±3.48° in abduction, 27.50±4.28° in adduction, 42.22±4.60° in internal rotation, and 42.22±3.91° in external rotation. Conclusion: Surgery performed on adolescent patients using an adult PHLP showed good, safe results. Therefore, it should be considered as an alternative option.

Dual Plate Fixation for Periprosthetic Femur Fracture after Total Knee Arthroplasty (슬관절 전치환술 후 발생한 대퇴골 삽입물 주위 골절의 이중 금속판 고정술)

  • Kim, Dong Hwi;Cha, Dong Hyuk;Ko, Kang Yeol
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.26-33
    • /
    • 2021
  • Purpose: This study evaluated the results of dual plate fixation for periprosthetic femur fracture after total knee arthroplasty (TKA). Materials and Methods: From October 2007 to February 2013, 23 cases of periprosthetic femur fracture after TKA were treated at the author's hospital. There were 13 cases of fixation using a medial and lateral dual plate when the stability of the fracture site could not be achieved by one side fixation with a follow-up of more than one year. The cases included no loosening of the femoral component in fractures that were categorized as Lewis-Rorabeck classification II and supracondylar comminuted fractures and elongation of the fracture line to the lateral epicondyle of the femur or stem in the medullary canal. The mean age was 72 years (65-82 years), and 11 cases were female. Three cases had a stem due to revision. The mean bone marrow density was -3.2 (-1.7 to -4.4), and the mean period from primary TKA to periprosthetic fractures was 28 months (1-108 months). The mean follow-up period was 23 months (12-65 months). The medial fracture site was first exposed via the subvastus approach. Second, the supplementary plate was fixed on the lateral side of the fracture using a minimally invasive plate osteosynthesis technique. The average union time, complications, and Hospital for Special Surgery Knee Score (HSS) at the last follow-up were evaluated. Results: The mean union time was 17.4 weeks (7-40 weeks). Two cases showed delayed bone union and nonunion occurred in one case, in whom bone union was achieved three months later after re-fixation using a dual plate with an autogenous bone graft. The mean varusvalgus angulation was 1.67 degrees (-1.2-4.9 degrees), and the mean anterior-posterior angulation was 2.86 degrees (0-4.9 degrees) at the last follow-up. The mean knee range of motion was 90 degrees, and the HSS score was 85 points (70-95 points) at the last follow-up. Conclusion: Dual plate fixation for periprosthetic femur fractures that had not achieved stability by one side plate fixation after TKA showed a good clinical result that allowed early rehabilitation.

Effects of Screw Configuration on Biomechanical Stability during Extra-articular Complex Fracture Fixation of the Distal Femur Treated with Locking Compression Plate (잠김 금속판(LCP-DF)을 이용한 대퇴골 원위부의 관절외 복합골절 치료시 나사못 배열에 따른 생체역학적 안정성 분석)

  • Kwon, Gyeong-Je;Jo, Myoung-Lae;Oh, Jong-Keon;Lee, Sung-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.3
    • /
    • pp.199-209
    • /
    • 2010
  • The locking compression plates-distal femur(LCP-DF) are being widely used for surgical management of the extra-articular complex fractures of the distal femur. They feature locking mechanism between the screws and the screw holes of the plate to provide stronger fixation force with less number of screws than conventional compression bone plate. However, their biomechanical efficacies are not fully understood, especially regarding the number of the screws inserted and their optimal configurations. In this study, we investigated effects of various screw configurations in the shaft and the condylar regions of the femur in relation to structural stability of LCP-DF system. For this purpose, a baseline 3-D finite element (FE) model of the femur was constructed from CT-scan images of a normal healthy male and was validated. The extra-articular complex fracture of the distal femur was made with a 4-cm defect. Surgical reduction with LCP-DF and bone screws were added laterally. To simulate various cases of post-op screw configurations, screws were inserted in the shaft (3~5 screws) and the condylar (4~6 screws) regions. Particular attention was paid at the shaft region where screws were inserted either in clustered or evenly-spaced fashion. Tied-contact conditions were assigned at the bone screws-plate whereas general contact condition was assumed at the interfaces between LCP-DF and bone screws. Axial compressive load of 1,610N(2.3 BW) was applied on the femoral head to reflect joint reaction force. An average of 5% increase in stiffness was found with increase in screw numbers (from 4 to 6) in the condylar region, as compared to negligible increase (less than 1%) at the shaft regardless of the number of screws inserted or its distribution, whether clustered or evenly-spaced. At the condylar region, screw insertion at the holes near the fracture interface and posterior locations contributed greater increase in stiffness (9~13%) than any other locations. Our results suggested that the screw insertion at the condylar region can be more effective than at the shaft during surgical treatment of fracture of the distal femur with LCP-DF. In addition, screw insertion at the holes close to the fracture interface should be accompanied to ensure better fracture healing.

Fracture analysis of wild mammals in South Korea

  • Jang, Hyunkyu;Park, Jong-Moon;Ahmed, Sohail;Seok, Seong-Hoon;Kim, Ho-Su;Yeon, Seong-Chan
    • Korean Journal of Veterinary Research
    • /
    • v.59 no.4
    • /
    • pp.175-180
    • /
    • 2019
  • This study was conducted to evaluate and analyze fractures types in wild mammals in Korea. Wild mammals treated at 3 wildlife centers in Korea were included. Of the 63 cases included in this study, water deer was the most common species encountered with fractures. We determined 85 different fracture sites, with maximum lumber vertebral fractures followed by femoral, tibial and pelvic fractures. External skeletal fixator (ESF)-intramedullary (IM) pin (IM+ESF tie-in fixation) was the most common method applied for the surgical treatment of mammals. Lumbar vertebrae and femur were the most common bones involved. The findings of this study are expected to provide information for veterinarians regarding the frequency and characteristics of fractures in wild mammals and serve as a basic database for the types and outcomes of fractures in wild mammals.

Results of Hip Arthroplasty Using a COREN Stem at a Minimum of Ten Years

  • Joon Soon Kang;Yoon Cheol Nam;Dae Gyu Kwon;Dong Jin Ryu
    • Hip & pelvis
    • /
    • v.34 no.4
    • /
    • pp.211-218
    • /
    • 2022
  • Purpose: We report on the 10-year clinical hip function and radiologic outcomes of patients who underwent hip arthroplasty using a COREN stem. Materials and Methods: A consecutive series of 224 primary cementless hip arthroplasty implantations were performed using a COREN stem between 2009 and 2011; among these, evaluation of 128 hips was performed during a minimum follow-up period of 10 years. The mean age of patients was 65.4 years (range, 40-82 years) and the mean duration of follow-up was 10.8 years (range, 10-12 years). Evaluation of clinical hip function and radiologic implant outcomes was performed according to clinical score, thigh pain, and radiologic analysis. Results: Dramatic improvement of the mean Harris hip score (HHS) from 59.4 preoperatively to 93.5 was observed at the final follow-up (P≤0.01). Stable fixation was demonstrated for all implants with no change in position except for one case of Vancouver type B2 periprosthetic femur fracture. A radiolucent line (RLL) was observed in 16 hips (12.5%). Thigh pain was observed in only two hips (1.6%) at the final follow-up. There were no cases of osteolysis around the stem. The survival rate for the COREN stem was 97.7%. Conclusion: Good long-term survival with excellent clinical and radiological outcomes can be achieved using the COREN femoral stem regardless of Dorr type.

Retrospective Study on Surgical Repair of 31 Canine Pelvic Fracture Cases (골반 골절의 수술적 교정을 실시한 31두 개에서의 후향연구)

  • Lee, Seung-Hoon;Park, Sung-Su;Kang, Byung-Jae;Kim, Yong-Sun;Kim, Wan-Hee;Kweon, Oh-Kyeong
    • Journal of Veterinary Clinics
    • /
    • v.29 no.1
    • /
    • pp.8-11
    • /
    • 2012
  • The results of surgical repair for pelvic factures in 31 dogs were reviewed. Lameness and weight bearing scores were used to evaluate functional recovery of the hind limbs. Simple fracture occurred in sacroiliac joint (n = 5) and ilium (n = 3). Pelvic fractures had acetabular (n = 7) and non-acetabular fractures (n = 23). Acetabular fracture cases were composed of additional surgical treatments with femoral head and neck ostectomy (FHNO) (n = 4) and only acetabular rim fixation (n = 3). Simple fractures had more rapid initial and complete recovery times than multiple fractures. Non-acetabular fracture cases (initial recovery time: 2.7 weeks, complete recovery time: 9.1 weeks) had more rapid initial and complete recovery times than acetabular fracture cases (8.4, 12.5 weeks) (p < 0.05). In addition, the cases of additional surgical treatment with FHNO (5.3, 7 weeks) had more rapid mean recovery times than surgical treatment without FHNO (11.1, 16.3 weeks). Surgical approach with FHNO in acetabular fracture was an alternative method to treat pelvic fractures in small breed dogs.

New Approach in the Treatment of Intertrochanteric Fracture Using a Cephalomedullary Nail (골수정을 이용한 대퇴골 전자간 골절의 새로운 치료 경향)

  • Kim, Junyoung;Choi, Kihong;Yang, Kyu Hyun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.3
    • /
    • pp.193-199
    • /
    • 2020
  • A gamma nail has been used to treat intertrochanteric fractures since 1988. Although such cephalomedullary nails have mechanical advantages over extramedullary fixation devices, such as sliding hip screw, their beneficial effects on treating the Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) 31-A1 and 31-A2 fractures are still controversial. During their 30-year history, many problems have been overcome, and new types of cephalomedullary nails have been introduced in clinical practice. New cephalomedullary nail systems facilitate nailing procedures and enhance the purchase capability of the femoral head by a lag screw. On the other hand, the failure rate still depends on the hands of the orthopedic surgeons. This review article focused on the basic principle of medial support and restoration of a medial buttress during the treatment of trochanteric fractures using a cephalomedullary nail.

Potential Seizurogenic Effect of Tramadol in a Dog with Necrotizing Meningoencephalitis (괴사성 뇌척수막염을 가진 진돗개에서 Tramadol에 의한 잠재적 경련발생 증례)

  • Kim, Se-Hun;Heo, Su-Young;Lee, Ki-Chang;Lee, Hae-Beom;Kim, Nam-Soo;Kim, Min-Su
    • Journal of Veterinary Clinics
    • /
    • v.28 no.3
    • /
    • pp.323-327
    • /
    • 2011
  • A Jindo dog (8-month-old, intact male) was referred for hind limb lameness on the right side. The dog was diagnosed with a simple femoral fracture by radiological examination. After surgical fixation of the femoral fracture, tramadol: a narcotic-like synthetic analgesic was intravenously administrated for post-operative analgesia. After injection of the tramadol, generalized tonic clonic seizure was immediately occurred in the dog. Seventeen hours later, the dog died despite intensive care. We suspected that tramadol might induce the seizurogenic effect resulted in death. A necropsy was performed to examine the cause of the death. In consequence, the dog was diagnosed as necrotizing meningoencephalitis (NME) based on histopathological examination. We would be concerned that tramadol may be related to seizure activity in the NME patient. From this case, it is known that although tramadol has been proven to be a safe and effective agent for the control of pain in veterinary medicine, it would be carefully used to patient with history of neurological diseases including meningoencephalitis, hydrocephalus, and encephalopathy.