• Title/Summary/Keyword: Fixation failure

Search Result 165, Processing Time 0.027 seconds

Screw Fixation Techniques for Talar Neck Fractures (Anterior versus Posterior insertion) (거골 경부 골절의 나사못 고정 방향에 따른 결과 비교)

  • Shin, Dong-Eun;Yoon, Hyung-Ku;Choi, Woo-Jin;Lee, Yoon-Seok;Han, Seung-Chul
    • Journal of Korean Foot and Ankle Society
    • /
    • v.14 no.1
    • /
    • pp.79-83
    • /
    • 2010
  • Purpose: To compare the clinical and radiological results between the anterior and posterior screw fixation for the treatment of talar neck fracture. Materials and Methods: Among 30 patients who received surgical treatment for talar neck fracture from 2001 to 2008. Twenty-seven patients with a follow-up period of more than 1 year were divided into two groups. Twelve patients were treated with anterior screw fixation and 15 patients with posterior approaches. We analyzed preoperative, postoperative and follow-up radiographs. Clinical results were evaluated by Hawkins criteria. Results: The posteriorly inserted screws were placed across the more central portion of the talar neck and perpendicular to the plane of fracture (p<0.05). There were no difference in clinical results, the duration of union, and complications including avascular necrosis between two groups. However, 2 patients complained of pain around the talonavicular joint in the anterior insertion group. Conclusion: Although the clinical results were good irrespective of insertion methods, the posterior approach of screw fixation for talar neck fractures allows for a better mechanical advantage than anterioly placed screws. This may allow early motion with a reduced risk of failure of fixation or of displacement of the fracture.

Combined Percutaneous and Minimal on Internal Fixation of Calcaneal Fractures Using Extensile Lateral Approach (광범위 외측 도달법을 이용한 종골 골절의 경피적 및 최소 내고정술)

  • Yu, Sun-O;Kim, Joo-Sung;Kim, Jong-Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.6 no.2
    • /
    • pp.201-207
    • /
    • 2002
  • Purpose: To present the clinical analysis of the results obtained in 38 cases of displaced intraarticular calcaneal fractures undergone combined percutaneous axial pin fixation of calcaneal body and minimal internal fixation using extensile lateral approach. Materials and Methods: From March 2000 to February 2002, thirty-eight displaced intraarticular fractures of the calcaneus in 35 patients were fixed with 3.5mm cannulated screws and percutaneous 2.5mm K-wires. The extensile lateral approach was used in all cases. The average follow-up period was 16 months. Clinical evaluation was assessed according to the Ankle-Hind Foot Scale of American Orthopedic Foot and Ankle Society. Results: The clinical results were graded as excellent in 8 cases(21%), good in 22 cases(58%), fair in 6 cases(16%), and poor in 2 cases(5%). Two cases of poor result were type IV of Sanders classification. The postoperative reduction status of the articular surface was analyzed by computed tomography in all cases and was found to be less 2mm of step off in 30 cases and between 2 and 4mm in 8 cases. Unsatisfactory results were correlated with severity of articular comminution and failure to obtain accurate reduction of the articular surface. Using early functional postoperative care, all fractures healed without secondary displacement except 1 case on an average of ten weeks. Two cases had superficial necrosis of the wound margins, however, secondary wound healing was uneventful and skin grafting was not needed. Conclusion: Combined minimal internal fixation and percutaneous pin fixation using extensile lateral approach is useful operative method of intraarticular calcaneal fractures because providing enough stability to permit functional aftercare and allowing excellent anatomical reduction. In addition, this method diminishes the risk of lateral soft tissue problems.

  • PDF

Biomechanical comparison of bone staple techniques for stabilizing tibial tuberosity fractures

  • Kyu-Tae Park;Min-Yeong Lee;Hwi-Yool Kim
    • Korean Journal of Veterinary Research
    • /
    • v.63 no.3
    • /
    • pp.24.1-24.6
    • /
    • 2023
  • This study compared the biomechanical properties of bone-stapling techniques with those of other fixation methods used for stabilizing tibial tuberosity fractures using 3-dimensionally (3D)-printed canine bone models. Twenty-eight 3D-printed bone models made from computed tomography scan files were used. Tibial tuberosity fractures were simulated using osteotomy. All samples were divided into 4 groups. Group 1 was stabilized with a pin and tension-band wire; group 2, with a pin and an 8 mm-wide bone staple; group 3, with 2 horizontally aligned pins and an 8 mm-wide bone staple; and group 4 with a 10 mm-wide bone staple. Tensile force was applied with vertical distraction until failure occurred. The load and displacement were recorded during the tests. The groups were compared based on the load required to cause displacements of 1, 2, and 3 mm. The maximum failure loads and modes were recorded. The loads at all displacements in group 4 were greater than those in groups 1, 2, and 3. The loads at 1, 2, and 3 mm displacements were similar in groups 1 and 3. There was no significant difference between groups 1 and 3. Groups 1 and 4 provided greater maximum failure loads than groups 2 and 3. Failure occurred because of tearing of the nylon rope, tibial fracture, wire breakage, pin bending, and fracture around the bone staple insertion. In conclusion, these results demonstrate that the bone-stapling technique is an acceptable alternative to tension-band wire fixation for the stabilization of tibial tuberosity fractures in canine bone models.

Scapular spine base fracture with long outside-in superior or posterior screws with reverse shoulder arthroplasty

  • Eroglu, Osman Nuri;Husemoglu, Bugra;Basci, Onur;Ozkan, Mustafa;Havitcioglu, Hasan;Hapa, Onur
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.3
    • /
    • pp.141-146
    • /
    • 2021
  • Background: The purpose of the present study was to determine how long superior screws alone or in combination with posterior placement of metaglene screws protruding and penetrating into the scapular spine in reverse total shoulder arthroplasty affect the strength of the scapular spine in a fresh cadaveric scapular model. Methods: Seven fresh cadaver scapulas were allocated to the control group (short posterior and superior screws) and seven scapulars to the study group (spine base fixation with a four long screws, three with both long superior and long posterior screws). Results: The failure load was lower in the spine fixation group (long screw, 869 N vs. short screw, 1,123 N); however, this difference did not reach statistical significance (p>0.05). All outside-in long superior or superior plus posterior screws failed due to scapular spine base fracture; failures in the short screw group were due to acromion fracture. An additional posterior outside-in screw failed to significantly decrease the failure load of the acromion spine. Conclusions: The present study highlights the significance of preventing a cortical breach or an outside-in configuration when a superior or posterior screw is inserted into the scapular spine base.

Comparative analysis of proximal humerus fracture management in elderly patients: complications of open reduction and internal fixation by shoulder surgeons and non-shoulder surgeons-a retrospective study

  • Rui Claro;Bianca Barros;Carlos Ferreira;Ana Ribau;Luis Henrique Barros
    • Clinics in Shoulder and Elbow
    • /
    • v.27 no.1
    • /
    • pp.32-38
    • /
    • 2024
  • Background: Open reduction and internal fixation (ORIF) with a locking plate is a popular surgical treatment for proximal humeral fractures (PHF). This study aimed to assess the occurrence of complications in elderly patients with PHF treated surgically using ORIF with a locking plate and to investigate the potential differences between patients treated by shoulder surgeons and non-shoulder surgeons. Methods: A retrospective study was conducted using a single-center database to identify patients aged ≥70 years who underwent ORIF for PHF between January 1, 2011, and December 31, 2021. Data on the Neer classification, follow-up, occurrence of avascular necrosis of the humeral head, implant failure, and revision surgery were also collected. Statistical analyses were performed to calculate the overall frequency of complications according to the Neer classification. Results: The rates of implant failure, avascular osteonecrosis, and revision surgery were 15.7%, 4.8%, and 15.7%, respectively. Complications were more common in patients with Neer three- and four-part fractures. Although the difference between surgeries performed by shoulder surgeons and non-shoulder surgeons did not reach statistical significance, the rate of complications and the need for revision surgery were nearly two-fold higher in the latter group. Conclusions: PHF are highly prevalent in the elderly population. However, the ORIF surgical approach, as demonstrated in this study, is associated with a considerable rate of complications. Surgeries performed by non-shoulder surgeons had a higher rate of complications and a more frequent need for revision surgery. Future studies comparing surgical treatments and their respective complication rates are crucial to determine the optimal therapeutic options. Level of evidence: III.

Unilateral Augmented Pedicle Screw Fixation for Foraminal Stenosis

  • Kim, Jeong-Gyun;Jin, Yong-Jun;Chung, Sang-Ki;Kim, Ki-Jeong;Kim, Hyun-Jib
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.1
    • /
    • pp.5-10
    • /
    • 2009
  • Objective: The purpose of this study is to evaluate the effectiveness of unilateral decompression and pedicle screw fixation for the unilateral symptomatic foraminal stenosis. Methods: The study group comprises consecutive 16 patients who underwent unilateral decompression and bone cement augmented pedicle screw fixation from May 2003 to January 2006. The patients were evaluated by visual analog scale (VAS) for pain and the scoring system of the Japanese Orthopedic Association (JOA) for low back pain. The result of surgery was also evaluated with McNab's classification. Excellent or good outcome was considered as successful. The patients were followed at postoperative 1 month, 3 month, 6 month, and 1 year with standing AP and lateral films. Results: The average VAS and JOA score of the 16 patients were 7.8(range, 6-9) and 5.8(range, 3 - 10) before surgery and 2.2(range, 0 - 5)and 12.3(range, 9 - 15) at the time of last follow up. Both VAS and JOA score improved significantly after the surgery (p<0.05, t-test). All patients improved after the operation and no revision surgery was required. No metal failure or pseudoarthrosis was observed during the follow-up. The success rate was 87.5%. Conclusion: Our data suggest that unilateral decompression and pedicle screw fixation for the unilateral symptomatic foraminal stenosis is an effect method for obtaining satisfactory clinical outcome. Its possible advantage is shorter operation time and reduced surgical extent. We believe that the reduced stiffness of unilateral fixation was compensated by pedicle screw augmentation and interbody fusion.

The Results and Complications of the C1-C2 Transarticular Screw Fixation Methods (축추-환추간 경관절 나사못 고정술 치료의 결과 및 합병증)

  • Choi, Jun-Woong;Yoon, Seung-Hwan;Park, Hyung-Chun;Park, Hyeon-Seon;Kim, Eun-Young;Ha, Yoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.3
    • /
    • pp.201-206
    • /
    • 2005
  • Objective: To evaluate the accuracy and safety of C1-C2 transarticular screw insertion, we retrospectively review surgical records and postoperative radiological findings. Methods: From January 2001 to October 2003, the C1-C2 transarticular screw fixation and posterior wiring with iliac bone grafts was performed in 16 patients. 6 patients had rheumatoid arthritis which caused cervical instability, 3 patients had os odontoideum, 3 patients had type 2 odontoid process fracture, 3 patients had traumatic transverse ligament injury and 1 patients who had been managed with C1-C2 wire fixation had psoriatic arthritis. Results: Osseous fusion was documented in 15 patients(93.8%). Only one patient was recorded screw loosening because of postoperative infection. One patient had only one screw placed because of abnormal anatomical structure, one patients was breakage of a Kirschner wire, and one screw was medial location to lateral mass of C1, but clinical results was excellent and radiological instability was not noted. Conclusion: The author's experience demonstrates that C1-C2 transarticular screw fixation with wired bone graft is a safe procedure with higher fusion rate but precaution is needed to avoid the neural damage, vertebral artery injury, and hardware failure.

Dorsal Short-Segment Fixation for Unstable Thoracolumbar Junction Fractures

  • Kim, Kwan-Sik;Oh, Sung-Han;Huh, Ji-Soon;Noh, Jae-Sub;Chung, Bong-Sub
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.4
    • /
    • pp.249-255
    • /
    • 2006
  • Objective : This study is to evaluate the efficacy of dorsal short-segment fixation in unstable thoracolumbar junction fractures. Methods : The cases of 20 patients who underwent dorsal short-segment fixation were reviewed retrospectively. Clinical outcomes were analysed using Sonntag's pain level, work status, and neurological scale according to the modified Frankel classification. Radiological outcomes were analysed using Mumford's anterior body compression[%], canal compromise ratio, and Cobb's kyphotic angle. Results : At the latest clinical follow-up [average=14.6 months]. there were 19 [95.0%] in group I and 1 patient [5.0%] in II in pain level. The postoperative work status were 17 [85.0%] in group I, 2 patients [10.0%] in II, and 1 patient [5.0%] in V. Surgery brought to improve the neurologic status. In success group [19 cases, 95%], the average canal compromise ratio was reduced from 0.57 [${\pm}0.07$] to 0.05 [${\pm}0.08$] [P<005], the average anterior body compression [%] was reduced from 41% [${\pm}17$] to 18% [${\pm}14$] [P<0.05], and the average preoperative kyphotic angle was $20.0^{\circ}$ [${\pm}9.0$], and corrected to $5.7^{\circ}$ [${\pm}7.1$] postoperatively, and progressed to $7.8^{\circ}$ [${\pm}6.2$] at the latest follow-up. There was a case of implantation failure in an elderly osteoporotic patient. Conclusion : Although there are limitations in the patient number and follow-up period, the present study favors dorsal short-segment fixation for selective cases in unstable thoracolumbar junction fractures.

Femoral Shaft Fracture in Klippel-Trenaunay-Weber Syndrome Patients - What to Do to Reduce Bleeding Risk: A Case Report

  • Byung-Chan Cho;Byung-Woo Min;Kyung-Jae Lee
    • Hip & pelvis
    • /
    • v.34 no.4
    • /
    • pp.262-268
    • /
    • 2022
  • A fracture of the affected extremity in patients with Klippel-Trenaunay-Weber syndrome can be fatal due to massive bleeding and show poor results. A 42-year-old male presented with an old fracture of the right femoral shaft with metal failure. We planned an operation to remove the previously fixed plate and to perform re-fixation using an intra-medullary nail. Preoperative angiography was performed and the arteriovenous malformations were embolized in order to reduce the risk of bleeding. After angiography, the previously fixed plate was removed. After the operation, a second angiography was performed immediately and the venous malformation was embolized. One week after the first operation, a second operation was performed in order to reduce the fracture and to perform re-fixation using an intramedullary nail. The patient is being followed without major complication over a period of seven years after surgery. We recommend careful planning of preoperative and postoperative angiography and embolization in order to reduce the risk of bleeding in patients with Klippel-Trenaunay-Weber syndrome.

Complications after Surgical Correction of Hallux Valgus (무지 외반증 교정 수술 후 합병증)

  • Bae, Su-Young;Lee, Oei-Jong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.21 no.2
    • /
    • pp.50-54
    • /
    • 2017
  • The goal of surgical correction for hallux valgus is to achieve a painless, shoe-wearable, and relatively straight toe with a balanced joint motion that results in aesthetically and functionally satisfactory toe. To date, there has not been a consensus on the ultimate surgical procedure for hallux valgus correction. Unfortunately, such a consensus may be difficult since it is not uncommon to encounter complications after hallux valgus correction. Postoperative soft tissue complications include difficult wound healing, infection, hypertrophy, or pain of the scar, joint stiffness, and tendon or sensory nerve damage. Postoperative bony complications include malunion, nonunion, failure of fixation, failure of angle correction, recurred deformity, osteomyelitis, and failure of balance between the metatarsal heads. Herein, we review common complications after surgical correction of hallux valgus, such as stiff joint, bony complications, recurrence of the deformity, and hallux varus.