A Study on the Scale and Dimensions of member of Sectional structure for Five-Purlin Houses from Joseon Era (조선시대 민가 오량가(五樑架) 종단구성의 규모와 부재치수에 관한 연구)

  • Kim, Jae-Ung
    • Journal of architectural history
    • /
    • v.28 no.1
    • /
    • pp.7-16
    • /
    • 2019
  • As a part of the research on existing structures of private homes from Joseon Era. Focusing on one hundred twenty five-purlin houses, the current study investigated the features and characteristics of the house structure from style, size, proportion and roof pitch, and measurements of key parts, and developed the following conclusions. Most are single-houses (89, 83%), and among them, there are 47 single front-terrace houses (39%), which is the highest number. The sizes of lower house structure do not differ greatly depending on the vertical structure, and single rear terrace house and double-house have relatively larger side sizes. The size of upper structure is larger in double-houses compared to other vertical structures, indicating a relatively higher roof. The cross-section measurement of major parts show that double-houses are larger than single-houses by 3cm in pillar, 3-4.5cm in crossbeam length, and 4.5cm in crossbeam width. However, Janghyeo width was consistent at 7.5 to 10.5cm, maintaining uniformity regardless of vertical structure of the houses. In addition, the cross-section measurements decreased from sixteenth to nineteenth century, with the size of pillar size decreasing the most. The result that the Janghyeo width is not related to the house structure house confirmed that the Janghyeo width was kept consistent regardless of the size of the house structure.

Effect of a Supplementary Pole on the Structural Stability in the Single-span Plastic Greenhouses (단동하우스에서의 보강지주 설치 효과)

  • Yum, Sung-Hyun;Kim, Seoung-Hee;Lee, Sang-Bong;Kim, Min-Young;Kim, Chul-Soo
    • Journal of Bio-Environment Control
    • /
    • v.19 no.2
    • /
    • pp.63-69
    • /
    • 2010
  • This study was implemented to clarify the effect of a supplementary pole on the increment of safety snow-depth for the single-span plastic greenhouses which had been run as standardized facilities for 10 to 15 years till April, 2007. In the previous work, some of the basic ideas of the use of a temporary pole were discussed, but application was restricted to both 2-D and the cases which took rafter's specifications into no consideration, and there was also much less experimental information available. So, by modeling the house as the 3-D frame structure, the present study attempted to provide a comprehensive review of the pole's effect through structural analyses as well as measurements. Structural analyses abnormally revealed that the pole regardless of its interval had a negative effect on the structural stability. The results was certainly inconsistent with practical experience and hence implied a necessity of reinforcing the roof purlin. Accordingly, with the purlin being sufficiently reinforced, the plastic greenhouse with the pole's interval of 3~4 m had two times safety snow-depth more than that of the plastic greenhouse without the pole. And the safety snow-depth of five types of the single-span plastic greenhouses according to the pole's intervals was presented.