• Title/Summary/Keyword: Fitting parameters

Search Result 712, Processing Time 0.027 seconds

Experimental Study on the Hysteresis of Suction Stress in Unsaturated Sand (불포화 모래의 흡입응력 이력현상에 대한 실험적 연구)

  • Song, Young-Suk;Choi, Jin-Su;Kim, Gyo-Won
    • The Journal of Engineering Geology
    • /
    • v.22 no.2
    • /
    • pp.145-155
    • /
    • 2012
  • The matric suction and volumetric water content of Jumunin standard sand with a relative density of 60% were measured using an Automated Soil-Water Characteristic Curve (SWCC) apparatus during both drying and wetting processes. The test time for the drying process was longer than that for the wetting process, because the flow of water is likely to be protected by air trapped in voids within the soils during the drying process. Based on the matric suction and volumetric water content, the SWCC was estimated using the model proposed by van Genuchten (1980). For the drying process, the unsaturated fitting parameters ${\alpha}$, n, and m were 0.399, 8.586, and 0.884, respectively; for the wetting process, the values were 0.548, 5.625, and 8.220, respectively. The hysteresis phenomenon occurred in the SWCCs, which means the SWCC of the drying process is not matched with the SWCC of the wetting process. Using these unsaturated parameters, we estimated the Suction Stress Characteristic Curve (SSCC), based on the relationship between suction stress and the effective degree of saturation. The suction stress showed a rapid decrease when the matric suction exceeds the Air Entry Value (AEV). Therefore, the effective stress of unsaturated soils is different from that of saturated soils when the matric suction exceeds the AEV. The suction stress of the drying process exceeds that of the wetting process for a given effective degree of saturation. The hysteresis phenomenon was also recognized in SSCCs. The hysteresis phenomenon of SSCCs arises from that of SWCCs, which is induced by the ink bottle effect and the contact angle effect. In the case of a sandy slope, the suction stress is positive and acts to enhance the slope stability as the water infiltrates the ground, but is negative when the suction stress exceeds the AEV. The results obtained for the wetting process should be applied in analyses of slope stability, because the process of water infiltration into ground is similar to the wetting process.

NEAR-INFRARED VARIABILITY OF OPTICALLY BRIGHT TYPE 1 AGN (가시광에서 밝은 1형 활동은하핵의 근적외선 변광)

  • JEON, WOOYEOL;SHIM, HYUNJIN;KIM, MINJIN
    • Publications of The Korean Astronomical Society
    • /
    • v.36 no.3
    • /
    • pp.47-63
    • /
    • 2021
  • Variability is one of the major characteristics of Active Galactic Nuclei (AGN), and it is used for understanding the energy generation mechanism in the center of AGN and/or related physical phenomena. It it known that there exists a time lag between AGN light curves simultaneously observed at different wavelengths, which can be used as a tool to estimate the size of the area that produce the radiation. In this paper, We present long term near-infrared variability of optically bright type 1 AGN using the Wide-field Infrared Survey Explorer data. From the Milliquas catalogue v6.4, 73 type 1 QSOs/AGN and 140 quasar candidates are selected that are brighter than 18 mag in optical and located within 5 degree around the ecliptic poles. Light curves in the W1 band (3.4 ㎛) and W2 band (4.6 ㎛) during the period of 2010-2019 were constructed for these objects by extracting multi-epoch photometry data from WISE and NEOWISE all sky survey database. Variability was analyzed based on the excess variance and the probability Pvar. Applying both criteria, the numbers of variable objects are 19 (i.e., 26%) for confirmed AGN and 12 (i.e., 9%) for AGN candidates. The characteristic time scale of the variability (τ) and the variability amplitude (σ) were derived by fitting the DRW model to W1 and W2 light curves. No significant correlation is found between the W1/W2 magnitude and the derived variability parameters. Based on the subsample that are identified in the X-ray source catalog, there exists little correlation between the X-ray luminosity and the variability parameters. We also found four AGN with changing W1-W2 color.

Case Analysis of the Promotion Methodologies in the Smart Exhibition Environment (스마트 전시 환경에서 프로모션 적용 사례 및 분석)

  • Moon, Hyun Sil;Kim, Nam Hee;Kim, Jae Kyeong
    • Journal of Intelligence and Information Systems
    • /
    • v.18 no.3
    • /
    • pp.171-183
    • /
    • 2012
  • In the development of technologies, the exhibition industry has received much attention from governments and companies as an important way of marketing activities. Also, the exhibitors have considered the exhibition as new channels of marketing activities. However, the growing size of exhibitions for net square feet and the number of visitors naturally creates the competitive environment for them. Therefore, to make use of the effective marketing tools in these environments, they have planned and implemented many promotion technics. Especially, through smart environment which makes them provide real-time information for visitors, they can implement various kinds of promotion. However, promotions ignoring visitors' various needs and preferences can lose the original purposes and functions of them. That is, as indiscriminate promotions make visitors feel like spam, they can't achieve their purposes. Therefore, they need an approach using STP strategy which segments visitors through right evidences (Segmentation), selects the target visitors (Targeting), and give proper services to them (Positioning). For using STP Strategy in the smart exhibition environment, we consider these characteristics of it. First, an exhibition is defined as market events of a specific duration, which are held at intervals. According to this, exhibitors who plan some promotions should different events and promotions in each exhibition. Therefore, when they adopt traditional STP strategies, a system can provide services using insufficient information and of existing visitors, and should guarantee the performance of it. Second, to segment automatically, cluster analysis which is generally used as data mining technology can be adopted. In the smart exhibition environment, information of visitors can be acquired in real-time. At the same time, services using this information should be also provided in real-time. However, many clustering algorithms have scalability problem which they hardly work on a large database and require for domain knowledge to determine input parameters. Therefore, through selecting a suitable methodology and fitting, it should provide real-time services. Finally, it is needed to make use of data in the smart exhibition environment. As there are useful data such as booth visit records and participation records for events, the STP strategy for the smart exhibition is based on not only demographical segmentation but also behavioral segmentation. Therefore, in this study, we analyze a case of the promotion methodology which exhibitors can provide a differentiated service to segmented visitors in the smart exhibition environment. First, considering characteristics of the smart exhibition environment, we draw evidences of segmentation and fit the clustering methodology for providing real-time services. There are many studies for classify visitors, but we adopt a segmentation methodology based on visitors' behavioral traits. Through the direct observation, Veron and Levasseur classify visitors into four groups to liken visitors' traits to animals (Butterfly, fish, grasshopper, and ant). Especially, because variables of their classification like the number of visits and the average time of a visit can estimate in the smart exhibition environment, it can provide theoretical and practical background for our system. Next, we construct a pilot system which automatically selects suitable visitors along the objectives of promotions and instantly provide promotion messages to them. That is, based on the segmentation of our methodology, our system automatically selects suitable visitors along the characteristics of promotions. We adopt this system to real exhibition environment, and analyze data from results of adaptation. As a result, as we classify visitors into four types through their behavioral pattern in the exhibition, we provide some insights for researchers who build the smart exhibition environment and can gain promotion strategies fitting each cluster. First, visitors of ANT type show high response rate for promotion messages except experience promotion. So they are fascinated by actual profits in exhibition area, and dislike promotions requiring a long time. Contrastively, visitors of GRASSHOPPER type show high response rate only for experience promotion. Second, visitors of FISH type appear favors to coupon and contents promotions. That is, although they don't look in detail, they prefer to obtain further information such as brochure. Especially, exhibitors that want to give much information for limited time should give attention to visitors of this type. Consequently, these promotion strategies are expected to give exhibitors some insights when they plan and organize their activities, and grow the performance of them.

Performance Evaluation of Machine Learning and Deep Learning Algorithms in Crop Classification: Impact of Hyper-parameters and Training Sample Size (작물분류에서 기계학습 및 딥러닝 알고리즘의 분류 성능 평가: 하이퍼파라미터와 훈련자료 크기의 영향 분석)

  • Kim, Yeseul;Kwak, Geun-Ho;Lee, Kyung-Do;Na, Sang-Il;Park, Chan-Won;Park, No-Wook
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.5
    • /
    • pp.811-827
    • /
    • 2018
  • The purpose of this study is to compare machine learning algorithm and deep learning algorithm in crop classification using multi-temporal remote sensing data. For this, impacts of machine learning and deep learning algorithms on (a) hyper-parameter and (2) training sample size were compared and analyzed for Haenam-gun, Korea and Illinois State, USA. In the comparison experiment, support vector machine (SVM) was applied as machine learning algorithm and convolutional neural network (CNN) was applied as deep learning algorithm. In particular, 2D-CNN considering 2-dimensional spatial information and 3D-CNN with extended time dimension from 2D-CNN were applied as CNN. As a result of the experiment, it was found that the hyper-parameter values of CNN, considering various hyper-parameter, defined in the two study areas were similar compared with SVM. Based on this result, although it takes much time to optimize the model in CNN, it is considered that it is possible to apply transfer learning that can extend optimized CNN model to other regions. Then, in the experiment results with various training sample size, the impact of that on CNN was larger than SVM. In particular, this impact was exaggerated in Illinois State with heterogeneous spatial patterns. In addition, the lowest classification performance of 3D-CNN was presented in Illinois State, which is considered to be due to over-fitting as complexity of the model. That is, the classification performance was relatively degraded due to heterogeneous patterns and noise effect of input data, although the training accuracy of 3D-CNN model was high. This result simply that a proper classification algorithms should be selected considering spatial characteristics of study areas. Also, a large amount of training samples is necessary to guarantee higher classification performance in CNN, particularly in 3D-CNN.

Investigation of O4 Air Mass Factor Sensitivity to Aerosol Peak Height Using UV-VIS Hyperspectral Synthetic Radiance in Various Measurement Conditions (UV-VIS 초분광 위성센서 모의복사휘도를 활용한 다양한 관측환경에서의 에어로솔 유효고도에 대한 O4 대기질량인자 민감도 조사)

  • Choi, Wonei;Lee, Hanlim;Choi, Chuluong;Lee, Yangwon;Noh, Youngmin
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_1
    • /
    • pp.155-165
    • /
    • 2020
  • In this present study, the sensitivity of O4 Air Mass Factor (AMF) to Aerosol Peak Height (APH) has been investigated using radiative transfer model according to various parameters(wavelength (340 nm and 477 nm), aerosol type (smoke, dust, sulfate), aerosol optical depth (AOD), surface reflectance, solar zenith angle, and viewing zenith angle). In general, it was found that O4 AMF at 477 nm is more sensitive to APH than that at 340 nm and is stably retrieved with low spectral fitting error in Differential Optical Absorption Spectroscopy (DOAS) analysis. In high AOD condition, sensitivity of O4 AMF on APH tends to increase. O4 AMF at 340 nm decreased with increasing solar zenith angle. This dependency isthought to be induced by the decrease in length of the light path where O4 absorption occurs due to the shielding effect caused by Rayleigh and Mie scattering at high solar zenith angles above 40°. At 477 nm, as the solar zenith angle increased, multiple scattering caused by Rayleigh and Mie scattering partly leads to the increase of O4 AMF in nonlinear function. Based on synthetic radiance, APHs have been retrieved using O4 AMF. Additionally, the effect of AOD uncertainty on APH retrieval error has been investigated. Among three aerosol types, APH retrieval for sulfate type is found to have the largest APH retrieval error due to uncertainty of AOD. In the case of dust aerosol, it was found that the influence of AOD uncertainty is negligible. It indicates that aerosol types affect APH retrieval error since absorption scattering characteristics of each aerosol type are various.

Estimation of $T_2{^*}$ Relaxation Times for the Glandular Tissue and Fat of Breast at 3T MRI System (3테슬러 자기공명영상기기에서 유방의 유선조직과 지방조직의 $T_2{^*}$이완시간 측정)

  • Ryu, Jung Kyu;Oh, Jang-Hoon;Kim, Hyug-Gi;Rhee, Sun Jung;Seo, Mirinae;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Purpose : $T_2{^*}$ relaxation time which includes susceptibility information represents unique feature of tissue. The objective of this study was to investigate $T_2{^*}$ relaxation times of the normal glandular tissue and fat of breast using a 3T MRI system. Materials and Methods: Seven-echo MR Images were acquired from 52 female subjects (age $49{\pm}12 $years; range, 25 to 75) using a three-dimensional (3D) gradient-echo sequence. Echo times were between 2.28 ms to 25.72 ms in 3.91 ms steps. Voxel-based $T_2{^*}$ relaxation times and $R_2{^*}$ relaxation rate maps were calculated by using the linear curve fitting for each subject. The 3D regions-of-interest (ROI) of the normal glandular tissue and fat were drawn on the longest echo-time image to obtain $T_2{^*}$ and $R_2{^*}$ values. Mean values of those parameters were calculated over all subjects. Results: The 3D ROI sizes were $4818{\pm}4679$ voxels and $1455{\pm}785$ voxels for the normal glandular tissue and fat, respectively. The mean $T_2{^*}$ values were $22.40{\pm}5.61ms$ and $36.36{\pm}8.77ms$ for normal glandular tissue and fat, respectively. The mean $R_2{^*}$ values were $0.0524{\pm}0.0134/ms$ and $0.0297{\pm}0.0069/ms$ for the normal glandular tissue and fat, respectively. Conclusion: $T_2{^*}$ and $R_2{^*}$ values were measured from human breast tissues. $T_2{^*}$ of the normal glandular tissue was shorter than that of fat. Measurement of $T_2{^*}$ relaxation time could be important to understand susceptibility effects in the breast cancer and the normal tissue.

Least-Square Fitting of Intrinsic and Scattering Q Parameters (최소자승법(最小自乘法)에 의(衣)한 고유(固有) Q와 산란(散亂) Q의 측정(測定))

  • Kang, Ik Bum;McMechan, George A.;Min, Kyung Duck
    • Economic and Environmental Geology
    • /
    • v.27 no.6
    • /
    • pp.557-561
    • /
    • 1994
  • Q estimates are made by direct measurements of energy loss per cycle from primary P and S waves, as a function of frequency. Assuming that intrinsic Q is frequency independent and scattering Q is frequency dependent over the frequencies of interest, the relative contributions of each, to a total observed Q, may be estimated. Test examples are produced by computing viscoelastic synthetic seismograms using a pseudo spectral solution with inclusion of relaxation mechanisms (for intrinsic Q) and a fractal distribution of scatterers (for scattering Q). The composite theory implies that when the total Q for S-waves is smaller than that for P-waves (the usual situation), intrinsic Q is dominating; when it is larger, scattering Q is dominating. In the inverse problem, performed by a global least squares search, intrinsic $Q_p$ and $Q_s$ estimates are reliable and unique when their absolute values are sufficiently low that their effects are measurable in the data. Large $Q_p$ and $Q_s$ have no measurable effect and hence are not resolvable. Standard deviation of velocity $({\sigma})$ and scatterer size (A) are less unique as they exhibit a tradeoff as predicted by Blair's equation. For the P-waves, intrinsic and scattering contributions are of approximately the same importance, for S-waves, the intrinsic contributions dominate.

  • PDF

Pharmacokinetics of amoxicillin trihydrate in cultured eel Anguilla japonica by single oral and intravenous administrations (Amoxicillin trihydrate의 단독 경구투여 및 정맥투여에 따른 뱀장어, Anguilla japonica 체내 약물동태학적 특성)

  • Jeon, Eun-Ji;Seo, Jeong-Soo;Kim, Jin-Do;Jung, Sung-Hee;Kim, Myoung-Sug;Hwang, Jee-Youn;Park, Myoung-Ae;Jee, Bo-Young;Kim, Jin-Woo;Kim, Yi-Cheong
    • Journal of fish pathology
    • /
    • v.23 no.3
    • /
    • pp.357-367
    • /
    • 2010
  • The pharmacokinetic properties of amoxicillin trihydrate (Amox) were studied after single oral administration and single intravenous injection to cultured eel, Anguilla japonica, respectively (average $220{\pm}10\;g$, $28{\pm}1^{\circ}C$). Plasma samples were taken at 3, 5, 10, 15, 24, 30, 48, 96 and 144 h post-dose. The kinetic profile of absorption, distribution and elimination of Amox in plasma were analyzed fitting to a two-compartment model by WinNonlin program. In oral dosage of 40 and 80 mg/kg body weight, the peak plasma concentrations of Amox, which attained at 3~12 h post-dose, were 3.4 and $3.3\;{\mu}g/ml$, respectively. In intravenous injection with 1 mg/kg, the peak plasma concentrations of Amox, which attained at 9 h post-dose, was $7.2\;{\mu}g/ml$. The following parmeters were calculated for a single oral dosage of 40 and 80 mg/kg body weight, respectively: AUC (the area under the concentration-time curve)= 464 and $667\;{\mu}g{\cdot}h/ml$; $T_{max}$ (time for maximum concentration)= 2.1 and 3.6 h; $C_{max}$ (maximum concentration)= 3.04 and $3.4\;{\mu}g/ml$. Following intravenous injection at 1 mg/kg, this parameters were AUC= $748\;{\mu}g{\cdot}h/ml$; $C_{max}=4.2\;{\mu}g/ml$. The apparent oral bioavailability at 40 and 80 mg/kg were 1.6 and 1.1%, respectively. Despite using the trihydrate form of amoxicillin, the oral bioavailability was low in eel.

Pharmacokinetics of cefadroxil after oral administration in olive flounder, Paralichthys olivaceus (Cefadroxil의 경구투여에 따른 넙치(Paralichthys olivaceus)에서의 약물동태학 연구)

  • Lee, Ji-Hoon;Park, Kwan Ha
    • Journal of fish pathology
    • /
    • v.31 no.1
    • /
    • pp.23-34
    • /
    • 2018
  • The pharmacokinetic properties of cefadroxil (CDX) were studied after oral administration for 7 days to cultured olive flounders (average 660 g), Paralichthys olivaceus. For examination of pharmaco-kinetic profiles, CDX of 45 to 225 mg/kg body weight was administered at two different water temperatures, $13{\pm}3^{\circ}C$ or $22{\pm}3^{\circ}C$. CDX concentrations were determined in muscle, plasma, gastrointestinal tract, hematopoietic organs and liver by HPLC-MS/MS. Muscle samples were taken at 0.25, 0.5, 1, 3, 7, 14 and 28 days post dose, whereas plasma, gastrointestinal tract, hematopoietic organs and liver concentrations were measured at 1, 3, 7, 14 and 28 days post-dosing. The kinetic profiles of $C_{max}$, $T_{max}$, $T_{1/2}$ of CDX were analyzed by fitting to a non-compartmental model with PKSolver program. The following pharmacokinetic parameters were obtained with oral administration of 45 and 225 mg/kg at 13 and $22^{\circ}C$ in muscle, plasma, gastrointestinal tract, hematopoietic organs and liver, respectively: $C_{max}$ (maximum tissue concentration)=$985.98-5,032.86{\mu}g/kg$, $5,670.99-38,922.23{\mu}g/l$, $2,457.27-10,192.78{\mu}g/kg$, $886.04-3,070.87{\mu}g/kg$ and $1,188.15-3,814.33{\mu}g/kg$; $T_{max}$ (time for maximum concentration)= every 1 day; $MRT_{0-{\infty}}$ (mean residence time)= 1.51-4.74, 2.12-3.06, 4.25-13.18, 1.37-18.66 and 1.78-29.76 days; $T_{1/2}$ (half-life)= 1.08-3.47, 1.14-5.42, 3.56-10.99, 1.17-14.93 and 1.25-28.55 days.

Evaluation of Liver Function Using $^{99m}-Lactosylated$ Serum Albumin Liver Scintigraphy in Rat with Acute Hepatic Injury Induced by Dimethylnitrosamine (Dimethylnitrosamine 유발 급성 간 손상 흰쥐에서 $^{99m}-Lactosylated$ Serum Albumin을 이용한 간 기능의 평가)

  • Jeong, Shin-Young;Seo, Myung-Rang;Yoo, Jeong-Ah;Bae, Jin-Ho;Ahn, Byeong-Cheol;Hwang, Jae-Seok;Jeong, Jae-Min;Ha, Jeong-Hee;Lee, Kyu-Bo;Lee, Jae-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.6
    • /
    • pp.418-427
    • /
    • 2003
  • Objects: $^{99m}-lactosylated$ human serum albumin (LSA) is a newly synthesized radiopharmaceutical that binds to asialoglycoprotein receptors, which are specifically presented on the hepatocyte membrane. Hepatic uptake and blood clearance of LSA were evaluated in rat with acute hepatic injury induced by dimethylnitrosamine (DMN) and results were compared with corresponding findings of liver enzyme profile and these of histologic changes. Materials and Methods: DMN (27 mg/kg) was injected intraperitoneally in Sprague-Dawley rat to induce acute hepatic injury. At 3(DMN-3), 8(DMN-8), and 21 (DMN-21) days after injection of DMN, LSA injected intravenously, and dynamic images of the liver and heart were recorded for 30 minutes. Time-activity curves of the heart and liver were generated from regions of interest drawn over liver and heart area. Degree of hepatic uptake and blood clearance of LSA were evaluated with visual interpretation and semiquantitative analysis using parameters (receptor index : LHL3 and index of blood clearance : HH3), analysis of time-activity curve was also performed with curve fitting using Prism program. Results: Visual assessment of LSA images revealed decreased hepatic uptake in DMN treated rat, compared to control group. In semiquantitative analysis, LHL3 was significantly lower in DMN treated rat group than control rat group (DMN-3: 0.842, DMN-8: 0.898, DMN-21: 0.91, Control: 0.96, p<0.05), whereas HH3 was significantly higher than control rat group (DMN-3: 0.731,.DMN-8: 0.654, DMN-21: 0.604, Control: 0.473, p<0.05). AST and ALT were significantly higher in DMN-3 group than those of control group. Centrilobular necrosis and infiltration of inflammatory cells were most prominent in DMN-3 group, and were decreased over time. Conclusion: The degree of hepatic uptake of LSA was inversely correlated with liver transaminase and degree of histologic liver injury in rat with acute hepatic injury.