• 제목/요약/키워드: First-order optics

검색결과 72건 처리시간 0.027초

열상장비용 줌무초점망원경 설계 (Optical Design of Afocal Zoom Telescope System for Thermal Imagery)

  • 홍경희;김창우
    • 한국광학회지
    • /
    • 제6권1호
    • /
    • pp.1-7
    • /
    • 1995
  • 열상장비용 줌망원경계통을 설계하였다. 대물경계는 4배로부터 14배까지 배율이 변화할 수 있는 줌광학계통으로 설계하였고 접안경은 초점거리 25mm의 삼중렌즈계통으로 설계하였다. 처음에는 대물경계와 접안경을 구분하여 설계하고 후에 이를 통합하여 무초점계로 설계하였다. 1st order optics에 의해 계통을 확립하고 3rd order optics에 의해 초기설계를 얻었으며 후에 유한광선추적으로 모든 고차수차를 포함하는 ray aberration 또는 angular aberration이 최소가 되도록 최적화 하였다. 최종설계를 회절광학적 MTF를 계산하여 성능을 평가하였다.

  • PDF

Effect of Solvent on Some Excited States Processes of Mg- and Zn-Phthalocyanines$^\dag$

  • Kim, Dong-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제7권6호
    • /
    • pp.416-421
    • /
    • 1986
  • The solvent coordination effect on the excited state processes of Mg(II)- and Zn(II)-phthalocyanines has been described. The triplet state of these compounds decays with mixed first and second order kinetics or mainly second order kinetics depending on the solvents used. The first order component of the rate constants decrease along with the series, dimethylsulfoxide (5-coordinated), 1-chloronaphthalene (4-coordinated) and piperidine (6-coordinated), while the second order rate constant is dependent on the diffusion rate constant of the solvents. The excited state quenching by methylviologen or p-benzoquinone is discussed. And ion recombination rate constant is given.

Integrated Optimization Design of Carbon Fiber Composite Framework for Small Lightweight Space Camera

  • Yang, Shuai;Sha, Wei;Chen, Changzheng;Zhang, Xingxiang;Ren, Jianyue
    • Journal of the Optical Society of Korea
    • /
    • 제20권3호
    • /
    • pp.389-395
    • /
    • 2016
  • A Carbon Fiber Composite (CFC) framework was designed for a small lightweight space camera. According to the distribution characteristics of each optical element in the optical system, CFC (M40J) was chosen to accomplish the design of the framework. TC4 embedded parts were used to solve the low accuracy of the CFC framework interface problem. An integrated optimization method and the optimization strategy which combined a genetic global optimization algorithm with a downhill simplex local optimization algorithm were adopted to optimize the structure parameters of the framework. After optimization, the total weight of the CFC framework and the TC4 embedded parts is 15.6 kg, accounting for only 18.4% that of the camera. The first order frequency of the camera reaches 104.8 Hz. Finally, a mechanical environment test was performed, and the result demonstrates that the first order frequency of the camera is 102 Hz, which is consistent with the simulation result. It further verifies the rationality and correctness of the optimization result. The integrated optimization method mentioned in this paper can be applied to the structure design of other space cameras, which can greatly improve the structure design efficiency.

Dynamic Modulation Transfer Function Analysis of Images Blurred by Sinusoidal Vibration

  • Du, Yanlu;Ding, Yalin;Xu, Yongsen;Sun, Chongshang
    • Journal of the Optical Society of Korea
    • /
    • 제20권6호
    • /
    • pp.762-769
    • /
    • 2016
  • The dynamic modulation transfer function (MTF) for image degradation caused by sinusoidal vibration is formulated based on a Bessel function of the first kind. The presented method makes it possible to obtain an analytical MTF expression derived for arbitrary frequency sinusoidal vibration. The error obtained by the use of finite order sum approximations instead of infinite sums is investigated in detail. Dynamic MTF exhibits a stronger random behavior for low frequency vibration than high frequency vibration. The calculated MTFs agree well with the measured MTFs with the slant edge method in imaging experiments. With the proposed formula, allowable amplitudes of any frequency vibration are easily calculated. This is practical for the analysis and design of the line-of-sight stabilization system in the remote sensing camera.

Off-axis Two-mirror System with Wide Field of View Based on Diffractive Mirror

  • Meng, Qingyu;Dong, Jihong;Wang, Dong;Liang, Wenjing
    • Journal of the Optical Society of Korea
    • /
    • 제19권6호
    • /
    • pp.604-613
    • /
    • 2015
  • An unobstructed off-axis two-mirror system is presented in this paper. First a suitable initial configuration is established based on third-order aberration theory. In order to achieve a wide field of view (FOV) with high image quality , the diffractive mirror is adopted in the two-mirror system to increase the optimization freedom and the aberration relationship between diffractive phase coefficients and Zernike coefficients is derived. Furthermore, a complete comparison design example with a focal length of 1200 mm, F-number of 12, and FOV of 40° × 2° is given to verify the aberration correction ability of the diffractive mirror. The system average wavefront error is 0.007 λ (λ=0.6328 μm) developed from 0.061 λ when the system didn’t adopt the diffractive mirror. In this system the phase modulation function of the diffractive mirror is established as an even function of x, so we could obtain a symmetrical imaging quality about the tangential plane, and the symmetric aberration performance also brings considerable convenience to alignment and testing for the system.

대학생의 심폐소생술에 대한 교육경험에 따른 지식 - 일 광역시를 중심으로 - (Knowledge According to Learning Experiences of CPR for Health Occupation College Students)

  • 엄동춘;전명희;황지영;최지예
    • 한국간호교육학회지
    • /
    • 제14권1호
    • /
    • pp.138-146
    • /
    • 2008
  • Purpose: The first responder's role during a cardiac arrest scene is to initiate CPR. The AHA has recognized and included the first responder's role for improving the survival rate of cardiac arrest patients. Health personnel working in nursing, emergency care, dental hygiene, radiology, and ocular optics frequently confront sudden cardiac arrest while working. This study was to identify the relationship between the educational experience and recognition with the level of knowledge about CPR for college students. Method: Five hundred forty college students enrolled in the department of nursing science, radiological technology, ocular optics, emergency medical technician, or dental hygiene in Daejeon city were surveyed. The tool used was CPR knowledge developed by the authors based on a literature review including 2005 AHA's CPR guideline. Result: The higher educational experience of CPR was, the higher the level of knowledge. The knowledge of the students in nursing or emergency medical technician was higher than students in dental hygiene, radiology, and ocular optics. Conclusion: CPR class should be included in the curriculum for college students in order to improve their accuracy as a first responder to cardiac arresting patients.

거친 표면 레이다 산란 해석을 위한 개선된 Kirchhoff 근사 방법 (An improved kirchhoff approximation for radar scattering from rough surfaces)

  • Oh, Yisok
    • 전자공학회논문지A
    • /
    • 제32A권1호
    • /
    • pp.45-52
    • /
    • 1995
  • A new Kirchhoff approximation(KA) method was proposed for microwave scttering from randomly rough surfaces. Using the spectral representation of delta function and its sifting theorem, a new KA was formulated directly without any further approximation, and this formulated was used to compute exact backscttering coefficients. The validity of the KA was verified by a numerical method, and this new KA technique was used to evaluate the existing approximated KkA methods; i.t., the zeroth-order and the first-order approximated physical optics(PO) models. It was shown that the first-order approximated PO model has small error than the zeroth-order approximated PO model at low incidence angles and the opposite happens at higher incidence angles. This new KA model can be used to compute exact scattering coefficients in the validity regions of KA and to evaluate other theoretical and numerical models for scattering from randomly rough surfaces.

  • PDF

부분적인 feed forward 제어 알고리즘을 사용한 고차 PMD 보상에 대한 연구 (Higher-order PMD compensator using partially feed forward algorithm)

  • 김나영;박남규
    • 한국광학회지
    • /
    • 제14권1호
    • /
    • pp.72-79
    • /
    • 2003
  • 본 논문에서는 고차 편광모드분산(PMD: polarization-mode dispersion)을 효과적으로 보상하기 위한 방법으로, DOP (degree of polarization)를 1차 PMD 보상을 위한 피드백 신호와 고차 PMD 보상을 위한 feed forward 신호로 사용하는 알고리즘을 제안하였다. 1차 보상이 끝난 후의 DOP값이 남아있는 고차 PMD의 정도를 나타내는 척도로써 인식하여 고차 PMD를 보상하는 시스템이 되겠다. 이러한 시스템은 고차 보상기의 자유도를 1차 보상기의 자유도로 제한하기 때문에 안정적이고 비교적 간단하게 구성할 수 있다는 장점이 있다. 제안된 알고리즘의 성능을 분석하기 위하여 10Gbps NRZ시스템의 전송 모의 실험을 수행하였으며, 그 결과 시스템 다운 시간인 outage probability가 약 세 배 가량 감소되는 것을 확인하였다.

적응광학에서의 대기 외란 모사: 이론에서 실제 적용까지 (Atmospheric Disturbance Simulation in Adaptive Optics: from Theory to Practice)

  • 이준호;박지현;주지용;한석기;정용석;김영수
    • 한국광학회지
    • /
    • 제35권5호
    • /
    • pp.199-209
    • /
    • 2024
  • 적응광학(adaptive optics) 시스템의 성능 예측은 설계 및 분석에 매우 중요한 요소이다. 적응광학 성능 예측은 몇 가지 가정과 스케일링 법칙을 기반으로 한 초기 성능 예측 방안이 주로 사용되며, 대기 난류 강도와 프로파일, 파면 센서 및 변형 거울 해상도에 따른 피팅(fitting) 에러, 파면 재구성 알고리즘을 통해 전파되는 파면 센서 노이즈, 제어 루프의 유한 대역폭으로 인한 서보 지연, 그리고 자연 상태의 별 및 레이저 가이드 별의 배열에 따른 아나이소플라나티즘(anisoplanatism) 등 다양한 매개변수와 오류 원인을 고려해야 한다. 하지만 가정에 기반한 초기 성능 예측 방안은 때때로 실제 성능과 동떨어진 결과를 낳을 수 있으므로, 전산 시뮬레이션과 테스트 베드에서 폐쇄 루프 테스트를 통한 평가가 함께 진행되어야 한다. 또한 폐쇄 루프 테스트를 위해서는 대기 모사기가 필요하며, 이는 대기 외란의 공간 및 시간적 특성을 충분히 모사할 수 있어야 한다. 본 논문은 이러한 대기 외란 모사의 이론적 배경과 함께 컴퓨터 시뮬레이션 및 광학 실험실 내에서의 구현 과정을 전반적으로 제시한다.

Performance Prediction of a Laser-guide Star Adaptive Optics System for a 1.6 m Telescope

  • Lee, Jun Ho;Lee, Sang Eun;Kong, Young Jun
    • Current Optics and Photonics
    • /
    • 제2권3호
    • /
    • pp.269-279
    • /
    • 2018
  • We are currently investigating the feasibility of a 1.6 m telescope with a laser-guide star adaptive optics (AO) system. The telescope, if successfully commissioned, would be the first dedicated adaptive optics observatory in South Korea. The 1.6 m telescope is an f/13.6 Cassegrain telescope with a focal length of 21.7 m. This paper first reviews atmospheric seeing conditions measured over a year in 2014~2015 at the Bohyun Observatory, South Korea, which corresponds to an area from 11.6 to 21.6 cm within 95% probability with regard to the Fried parameter of 880 nm at a telescope pupil plane. We then derive principal seeing conditions such as the Fried parameter and Greenwood frequency for eight astronomical spectral bands (V/R/I/J/H/K/L/M centered at 0.55, 0.64, 0.79, 1.22, 1.65, 2.20, 3.55, and $4.77{\mu}m$). Then we propose an AO system with a laser guide star for the 1.6 m telescope based on the seeing conditions. The proposed AO system consists of a fast tip/tilt secondary mirror, a $17{\times}17$ deformable mirror, a $16{\times}16$ Shack-Hartmann sensor, and a sodium laser guide star (589.2 nm). The high order AO system is close-looped with 2 KHz sampling frequency while the tip/tilt mirror is independently close-looped with 63 Hz sampling frequency. The AO system has three operational concepts: 1) bright target observation with its own wavefront sensing, 2) less bright star observation with wavefront sensing from another bright natural guide star (NGS), and 3) faint target observation with tip/tilt sensing from a bright natural guide star and wavefront sensing from a laser guide star. We name these three concepts 'None', 'NGS only', and 'LGS + NGS', respectively. Following a thorough investigation into the error sources of the AO system, we predict the root mean square (RMS) wavefront error of the system and its corresponding Strehl ratio over nine analysis cases over the worst ($2{\sigma}$) seeing conditions. From the analysis, we expect Strehl ratio >0.3 in most seeing conditions with guide stars.