• Title/Summary/Keyword: First molar

Search Result 1,022, Processing Time 0.023 seconds

Comparison of apical extrusion of intracanal bacteria by various glide-path establishing systems: an in vitro study

  • Dagna, Alberto;El Abed, Rashid;Hussain, Sameeha;Abu-Tahun, Ibrahim H;Visai, Livia;Bertoglio, Federico;Bosco, Floriana;Beltrami, Riccardo;Poggio, Claudio;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.4
    • /
    • pp.316-323
    • /
    • 2017
  • Objectives: This study compared the amount of apically extruded bacteria during the glide-path preparation by using multi-file and single-file glide-path establishing nickel-titanium (NiTi) rotary systems. Materials and Methods: Sixty mandibular first molar teeth were used to prepare the test apparatus. They were decoronated, blocked into glass vials, sterilized in ethylene oxide gas, infected with a pure culture of Enterococcus faecalis, randomly assigned to 5 experimental groups, and then prepared using manual stainless-steel files (group KF) and glide-path establishing NiTi rotary files (group PF with PathFiles, group GF with G-Files, group PG with ProGlider, and group OG with One G). At the end of canal preparation, 0.01 mL NaCl solution was taken from the experimental vials. The suspension was plated on brain heart infusion agar and colonies of bacteria were counted, and the results were given as number of colony-forming units (CFU). Results: The manual instrumentation technique tested in group KF extruded the highest number of bacteria compared to the other 4 groups (p < 0.05). The 4 groups using rotary glide-path establishing instruments extruded similar amounts of bacteria. Conclusions: All glide-path establishment instrument systems tested caused a measurable apical extrusion of bacteria. The manual glide-path preparation showed the highest number of bacteria extruded compared to the other NiTi glide-path establishing instruments.

THE THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE PARTIALLY EDENTULOUS IMPLANT PROSTHESIS WITH VARYING TYPES OF NON-RIGID CONNECTION (부분 무치악 임플랜트 보철 수복시 자연치와의 비고정성 연결형태에 따른 3차원 유한요소법적 연구)

  • Lee, Seon-A;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.1
    • /
    • pp.101-124
    • /
    • 1996
  • In this study, we designed the finite element models of mandible with varying their connecting types between the prosthesis on implant fixture and 2nd premolar, which were free-standing case(Mf), precision attachment case(Mp), semiprecision attachment case(Ms) and telescopic case(Mt). The basic model of the designed finite element models, which contained a canine and the 1st & 2nd premolar, was implanted in the edentulous site of the 1st & 2nd molar by two implant fixtures. We applied the load in all models by two ways. A vertical load of 200N was applied at each central fossa of 2nd premolar and 1st implant. A tilting load of 20N with inclination of $45^{\circ}$ to lingual side was applied to buccal cusp tips of each 2nd premolar and 1st implant. And then we analyzed three-dimensional finite element models, making a comparative study of principal stress and displacement in four cases respectively. Three-dimensional finite element analysis was performed for the stress distribution and the displacement using commercial software(IDEAS program) for SUN-SPARC workstation. The results were as follows : 1 Under vertical load or tilting load, maximum displacement appeared at the 2nd premolar. Semiprecision case showed the largest maximum displacement, and maximum displacement reduced in the order of precision attachment, free-standing and telescopic case. 2. Under vertical load. the pattern of displacement of the 1st implant appeared mesio-inclined because of the 2nd implant splinted together. But displacement pattern of the 2nd premolar varied according to their connection type with prosthesis. The 2nd premolar showed a little mesio-inclined vertical displacement in case of free-standing and disto-inclined vertical displacement due to attachment in case of precision and semiprecision attachment. In telescopic case, the largest mesio-inclined vertical displacement has been shown, so, the 1st premolar leaned mesial side. 3. Under tilting load, The pattern of displacement was similar in all four cases which appeared displaced to lingual side. But, the maximum displacement of 2nd premolar appeared larger than that of the first implant. Therefore, there was large discrepancy in displacement between natural tooth and implant during tilting load. 4. Under vertical load, the maximum compressive stress appeared at the 1st implant's neck. Semiprecision attachment case showed the largest maximum compressive stress, and the maximum compressive stress reduced in the order of precision attachment, telescopic and free-standing case. 5 Under vertical load, the maximum tensile stress appeared at the 2nd implant's distal neck. Semiprecision attachment case showed the largest maximum tensile stress, and the maximum tensile stress reduced in the order of precision attachment, telescopic and free-standing case. 6. Under vertical load or tilting load, principal stress appeared little between natural tooth & implant in free-standing case, but large principal stress was distributed at upper crown and distal contact site of the 2nd premolar in telescopic case. Principal stress appeared large at keyway & around keyway of distal contact site of the 2nd premolar in precision and semiprecision attachment case, appearing more broad and homogeneous in precision attachment case than in semiprecision attachment case.

  • PDF

Study about the relationship between the amount of posterior impaction and the change of occlusal plane angle and incisor inclination in Le Fort I osteotomy (Le Fort I 골절단술에서 posterior impaction의 양과 occlusal plane angle, incisor inclination의 변화 관계에 관한 연구)

  • Kim, Bok-Joo;Kim, Min-Gu;Kim, Jung-Han;Kim, Chul-Hoon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.5
    • /
    • pp.375-379
    • /
    • 2010
  • Introduction: In the management of dentofacial deformities, variable movement of the maxilla can be made possible by a Le Fort I osteotomy. Posterior impaction of the maxilla necessary for rotation of the maxillomandibular complex enhances the functions and esthetic results. In cases of posterior impaction of the maxilla, an increase in the figure of the occlusal plane angle and incisor inclination can occur. This study reports the relationship between the amount of posterior impaction and the change in the occlusal plane angle and incisor inclination in a Le Fort I osteotomy by preoperative and postoperative lateral cephalograms. Materials and Methods: Twenty patients who had undergone orthognathic surgery in Dong-A University Medical Center participated in this study. Lateral cephalometrics, within 3 weeks prior to surgery and 3 days after surgery, were used for analysis. Pre and postoperative measurements of the occlusal plane angle and incisal inclination based on the Frankfort horizontal (FH) plane were performed. X and Y were defined as the amount of vertical change in the upper incisor tip and the amount of vertical change in the upper first molar mesial cup tip through the operation. The amount of final posterior maxillary impaction was determined by subtracting Y from X, which is the difference in vertical height. According to the amount of posterior maxillary impaction, the change in the occlusal plane angle and incisal inclination was measured. Results: The average posterior maxillary impaction was 2.91 mm and the average change in the occlusal plane angle and incisal inclination was $6.54^{\circ}$after surgery. As a result, each mm of posterior maxillary impaction changed the occlusal plane angle and incisal inclination by $2.25^{\circ}$. Statistically, there was high significance. Two cases were observed: one with the same amount of posterior maxillary impaction performed on both the right and left showing $2.20^{\circ}$, and the other with a different amount of posterior maxillary impaction performed showing $2.35^{\circ}$. In this case, there was no significance difference between the two cases. Conclusion: Each mm of posterior maxillary impaction changes the occlusal plane angle and incisal inclination by an average of $2.25^{\circ}$. In posterior maxillary impaction, there was no significant difference in the amount of change in the occlusal plane angle and incisal inclination regardless of whether there was an equal amount of posterior maxillary impaction on both sides. This study is expected to help in the presurgical orthodontic preparation and presurgical treatment planning.

THE EFFECT OF ABUTMENT MATERIALS AND SURFACE TREATMENT ON RUBBER BASE IMPRESSION (고무 인상채득시 지대치재료와 표면처리법의 영향)

  • Jeong Do-Jin;Yang Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.2
    • /
    • pp.146-156
    • /
    • 2001
  • The purpose of this study was twofold. One was to evaluate the wettability of 4 elastomeric impression materials on tooth and different kinds of filling materials. The other was to identify the effect of topical surfactants sprayed on the surface of each impression. The elastomeric impression mate rials used in this experimental study were one polyether(Impregum F) and three polyvinyl siloxanes(Provil novo, Zerosil, Imprint). The abutments were prepared for 3/4 crown or onlay on the extracted human first molar. The filling materials used in this study for the duplication of prepared abutment were composite resin, amalgam, and casting metal. Impression was taken by manufacturer's recommendations and the number of voids on the impression surface was counted. The topical surfactants were Spannex $II^{(R)}$ and $Cohere^{(R)}$. The wettability was evaluated by comparing the number of voids between non-treated group and treated groups. The results were as follows : 1. $Zerosil^{(R)}$ showed the least number of voids on the impression surface. The number of voids increased in order of Provil $novo^{(R)}$, Impregum $F^{(R)}$, and $Imprint^{(R)}$. 2. Impregum $F^{(R)}$ and $Zerosil^{(R)}$ showed the least number of voids on the surface of dental stone master cast. The number is inclosed in order of Provil $novo^{(R)}$ and Imprint 3. When abutment material is tooth, the number of voids on the surface of master cast was smallest compared with that of other abutment materials. The number of voids increased in order of casting metal, amalgam and composite resin 4. The number of voids on the surface of the dental stone master cast was smallest when Spannex $II^{(R)}$ was used, followed by $Cohere^{(R)}$ treated group and non-treated group. These results suggest that the difference in wettability caused by the types of rubber base impression materials as well as abutment materials can affect the number of voids. And the use of topical surfactant for rubber base impression materials can improve the wettability of the materials and enhance the accurate master cast which has fewer surface voids.

  • PDF

EFFECT OF ANCHORAGE SYSTEMS ON LOAD TRANSFER WITH MANDIBULAR IMPLANT OVERDENTURES : A THREE-DIMENSIONAL PHOTOELASTIC STRESS ANALYSIS (하악 임플란트 overdenture에서 anchorage system이 하중전달에 미치는 영향)

  • Kim Jin-Yeol;Jeon Young-Chan;Jeong Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.5
    • /
    • pp.507-524
    • /
    • 2002
  • Load transfer of implant overdenture varies depending on anchorage systems that are the design of the superstructure and substructure and the choice of attachment. Overload by using improper anchorage system not only will cause fracture of the framework or screw but also may cause failure of osseointegration. Choosing anchorage system in making prosthesis, therefore, can be considered to be one of the most important factors that affect long-term success of implant treatment. In this study, in order to determine the effect of anchorage systems on load transfer in mandibular implant overdenture in which 4 implants were placed in the interforaminal region, patterns of stress distribution in implant supporting bone in case of unilateral vertical loading on mandibular left first molar were compared each other according to various types of anchorage system using three-dimensional photoelastic stress analysis. The five photoelastic overdenture models utilizing Hader bar without cantilever using clips(type 1), cantilevered Hader bar using clips(type 2), cantilevered Hader bar with milled surface using clips(type 3), cantilevered milled-bar using swivel-latchs and frictional pins(type 4), and Hader bar using clip and ERA attachments(type 5), and one cantilevered fixed-detachable prosthesis(type 6) model as control were fabricated. The following conclusions were drawn within the limitations of this study, 1. In all experimental models. the highest stress was concentrated on the most distal implant supporting bone on loaded side. 2. Maximum fringe orders on ipsilateral distal implant supporting bone in a ascending order is as follows: type 5, type 1, type 4, type 2 and type 3, and type 6. 3. Regardless of anchorage systems. more or less stresses were generated on the residual ridge under distal extension base of all overdenture models. To summarize the above mentioned results, in case of the patients with unfavorable biomechanical conditions such as not sufficient number of supporting implants, short length of the implant and unfavorable antero-posterior spread. selecting resilient type attachment or minimizing distal cantilever bar is considered to be appropriate methods to prevent overloading on implants by reducing cantilever effect and gaining more support from the distal residual ridge.

A COMPARATIVE STUDY OF THE PROBING ATTACHMENT LEVEL, RADIOGRAPHIC AND SURGICAL MEASUREMENT ACCORDING TO GINGIVAL INFLAMMATORY CONDITION (치은 염증 상태에 따른 치주낭 측정 깊이와 방사선학적 측정 깊이, 외과적 측정 깊이의 비교 연구)

  • Baik, Dong-Hoon;Chai, Jung-Kiu;Cho, Kyoo-Sung;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.2
    • /
    • pp.261-270
    • /
    • 1994
  • The purpose of this study was to evaluate relationship of probing attachment levels, radiographic measurements and surgical measurements according to gingival inflammatory condition. Patients with incipient to moderate periodontitis were selected. Upper and lower premolar and molar teeth excluding third molars were measured. At first visit, gingival index and bleeding on probing were taken, and subjects were grouped into 4 categories as follows : Experimental group I : gingival index 1 and no bleeding on probing. Experimental group II : gingival index 2 and no bleeding on probing absent. Experimental group III : gingival index 1 and bleeding on probing present. Experimental group IV : gingival index 2 and bleeding on probing present. Probing attachment levels were measured with manual probe on mesial and distal surfaces from cementoenamel junctions to terminal ends of probe. Radiographic measurements were made to assess bone loss by measuring the distance from cementoenamel junction to the alveolar crest. After thorough scating, a flap was raised exposing the alveolar bone and surgical measurements were made from cementoenamel junction to alveolar bone. The results were as follows: 1. Differences between probing attachment level and radiographic measurements showed $1.01{\pm}0.73mm$ for experimental group I, $0.98{\pm}0.48mm$ for experimental group II, $0.59{\pm}0.66mm$ for experimental group III, $0.98{\pm}0.38mm$ for experimental group IV and with no significant difference between groups. 2. Differences between probing attachment level and surgical measurements showed $1.36{\pm}0.80mm$ for experimental group I, $1.47{\pm}0.54mm$ for experimental group II, $1.06{\pm}0.39mm$ for experimental group III, $1.41{\pm}0.40mm$ for experimental group IV and with no significant difference between groups. 3. Differences between surgical and radiographic measurements showed $0.36{\pm}0.48mm$ for experimental group I, $0.51{\pm}0.54mm$ for experimental group II, $0.57{\pm}0.72mm$ for experimental group III, $0.41{\pm}0.49mm$ for experimental group IV and with significant difference between experimental group I and experimental group II, III, IV(P<0.05).

  • PDF

FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO PLATFORM WIDTH OF FIXTURE (임플란트 고정체의 platform의 크기에 따른 유한요소법적 응력분석)

  • Chung Kyung-Min;Chung Chae-Heon;Jeong Seung-Mi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.5
    • /
    • pp.674-688
    • /
    • 2003
  • Statement of Problem : With increasing demand of the implant-supported prosthesis, it is advantageous to use the different platform width of the fixture according to bone quantity and quality of the patients. Purpose : The purpose of this study was to assess the loading distributing characteristics of two implant designs according to each platform width of fixture, under vertical and inclined loading using finite element analysis. Material and method : The two kinds of finite element models were designed according to each platform width of future (4.1mm restorative component x 11.5mm length, 5.0mm wide-diameter restorative component x 11.5mm length). The crown for mandibular first molar was made using UCLA abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction, 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction and 200N at the buccal cusp in a 300 transverse direction individually Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment screw. Results : The stresses were concentrated mainly at the cortex in both vertical and oblique load ing but the stresses in the cancellous bone were low in both vertical and oblique loading. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading. Increasing the platform width of the implant fixture decreased the stress in the supporting bone, future and abutment screw. Increased the platform width of fixture decreased the stress in the crown and platform. Conclusion : Conclusively, this investigation provides evidence that the platform width of the implant fixture directly affects periimplant stress. By increasing the platform width of the implant fixture, it showed tendency to decreased the supporting bone, future and screw. But, further clinical studies are necessary to determine the ideal protocol for the successful placement of wide platform implants.

A SURVEY ON DENTAL HEALTH OF CHILDREN OF MULTICULTURAL FAMILIES IN CHONBUK PROVINCE (전북지역 다문화가족 어린이의 구강건강 실태조사)

  • Seo, Yun-Jin;Lee, Kwang-Hee;La, Ji-Young;An, So-Youn;Kim, Yun-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.2
    • /
    • pp.137-145
    • /
    • 2011
  • The purpose of this study was to obtain the data for dental caries experience and occlusal pattern to utilize these data for motivating oral health promotion and activating oral health care programme in preschool children of multicultural family. Caries prevalence on primary teeth was surveyed for 3-5 years old 190 children of multicultural families in Chonbuk province. The results were as follows : 1. Dental caries prevalence rate of primary teeth (dmf rate) was 61.7% at 3 years of age, 88.7% at 4 years of age, and 92.6% at 5 years of age (p>0.05). 2. Average score of dmft index was 2.22 at 3 years of age, 4.97 at 4 years of age, and 6.62 at 5 years of age (p>0.05). 3. Most of the caries-prevailed tooth was maxillary primary central incisor and showed 28.8% at 3 years of age, 56.7% at 5 years of age. 4. dmft index and dmfs index of children of Vietnamese, Cambodian, and Filipinos women were higher than those of Chinese and Japanese. 5. In sagittal primary molar relationship, flush terminal plane type was 82.6%, distal step type was 5.2% and mesial step type was 8.4%. This study is the first report for children of multicultural families in Korea. More attention for children of multicultural families will be needed in aspect of oral disease prevention and treatment.

EFFECT OF PHOSPHORIC ACID CONCENTRATION ON THE DIFFUSION OF HEMA THROUGH DENTIN (상아질을 통한 HEMA의 확산에 인산농도가 미치는 영향)

  • Yoon, Mi-Ran;Lee, Kwang-Won;Park, Soo-Joung
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.147-155
    • /
    • 1999
  • The purpose of this study was to investigate the effect of phosphoric acid concentration on the movement of 2-hydroxyethylmethacrylate(HEMA) from bonding resin - resin composite combination through dentin in vitro. Freshly extracted human third molar teeth were divided into four groups each of 10 teeth. A closed chamber with 1 ml distilled water was attached to the CEJ of each tooth. An occlusal cavity of 4mm diameter & remaining dentin thickness of 1.0-1.5mm was prepared in each tooth. Dentin was treated with 10% phosphoric acid gel for 15 seconds. 32% phosphoric acid gel for 15 seconds, or with 35% phosphoric acid gel for 15 seconds. A control group not treated with acid gel was also prepared. The cavities were rinsed, dried and then treated with the HEMA-containing All-Bond 2 primer & bonding resin which was light-cured for 10 seconds. The cavities were then restored with Z100 composite resin(shade:A3.5:3M Dent. Prod. USA) & light cured for 30 seconds. Water samples were retrieved from the chambers over a time course (4.32, 14.4, 43.2, 144 & 432 minutes ; 1, 3 & 10 days) and analyzed by high performance liquid chromatography. The results were as follows. 1. HEMA was detected in the pulp chambers of all teeth from 4.32 minutes after resin placement The highest rate of release was in the first sample period (0-4.32 min) & rate of release declined exponentially thereafter. 2. No significant differences were found for mean release rate for HEMA over a time course among the four groups (p>0.05). 3. The diffusion rate was significantly (p<0.05) less for 10% phosphoric acid gel than 32% phosphoric acid gel at the second sample period(4.32-14.4 min). 4. No significant differences were found for cumulative HEMA diffusion among the four groups at 10 days(p>0.05) and mean total(cumulative) release at 10 days for all groups was in the 9 - 16 nmol range. 5. The cumulative release was significantly (p<0.05) less for 10% phosphoric acid gel than 32% phophoric acid gel at the third(14.4-43.2 min) & fourth(43.2-144 min) sample period.

  • PDF

A comparison of on masse retraction of six anterior teeth with separate canine retraction (6전치 일괄(on masse) 견인과 견치 견인 후 4전치 견인 시 공간폐쇄 양상에 관한 연구)

  • Heo, Wook;Nahm, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.32 no.3 s.92
    • /
    • pp.165-174
    • /
    • 2002
  • The purpose of this study was to compare on masse retraction of six anterior teeth with separate canine retraction in the amount of the anchorage loss and the retraction of the anterior teeth. The subjects consisted of 30 adult female patients with Angle Class 1 malocclusions who were treated by .022' straight wire appliance with 4 first permolar extraction. They were composed of two groups. Group 1 consisted of 15 subjects, whose six anterior teeth were retracted by on masse retraction. Group 2 consisted of 15 subjects, whose canines were retracted separately. Pre-treatment and post-treatment lateral cephalometric radiographs were analyzed. All data were processed statistically with independent samples t-test, and the conclusions were as follows. 1. There was no significant difference in the amount of the anchorage loss between two groups(p>0.05). 2. There was no significant difference in the amount of the retraction of the anterior teeth between two groups(p>0.05). 3. There was a significant difference in the amount of the inclinational change of the upper incisors between two groups. It was greater in Group 2. 4. There was a significant difference in the vertical positional change of the upper incisal edges between two groups. The upper incisal edges in Group 2 were more extruded than Group 1 by about 1mm. 5. There was no significant difference in the vertical positional change of the root apex of the upper incisors between two groups(p>0.05). And there was no significant difference in the vertical positional change of the upper molar(p>0.05).