• Title/Summary/Keyword: First molar

Search Result 1,022, Processing Time 0.034 seconds

Synthesis, Characterization and DNA Interaction Studies of (N,N'-Bis(5-phenylazosalicylaldehyde)-ethylenediamine) Cobalt(II) Complex

  • Sohrabi, Nasrin;Rasouli, Nahid;Kamkar, Mehdi
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.8
    • /
    • pp.2523-2528
    • /
    • 2014
  • In the present study, at first, azo Schiff base ligand of (N,N'-bis(5-phenylazosalicylaldehyde)-ethylenediamine) ($H_2L$) has been synthesized by condensation reaction of 5-phenylazosalicylaldehyde and ethylenediamine in 2:1 molar ratio, respectively. Then, its cobalt complex (CoL) was synthesized by reaction of $Co(OAc)_2{\cdot}4H_2O$ with ligand ($H_2L$) in 1:1 molar ratio in ethanol solvent. This ligand and its cobalt complex containing azo functional groups were characterized using elemental analysis, $^1H$-NMR, UV-vis and IR spectroscopies. Subsequently, the interaction between native calf thymus deoxyribonucleic acid (ct-DNA) and CoL complex was investigated in 10 mM Tris/HCl buffer solution, pH = 7 using UV-vis absorption, thermal denaturation technique and viscosity measurements. From spectrophotometric titration experiments, the binding constant of CoL complex with ct-DNA was found to be $(2.4{\pm}0.2){\times}10^4M^{-1}$. The thermodynamic parameters were calculated by van't Hoff equation.The enthalpy and entropy changes were $5753.94{\pm}172.66kcal/mol$ and $43.93{\pm}1.18cal/mol{\cdot}K$ at $25^{\circ}C$, respectively. Thermal denaturation experiments represent the increasing of melting temperature of ct-DNA (about $0.93^{\circ}C$) due to binding of CoL complex. The results indicate that the process is entropy-driven and suggest that hydrophobic interactions are the main driving force for the complex formation.

Ceramic molar crown reproducibility by digital workflow manufacturing: An in vitro study

  • Jeong, II-Do;Kim, Woong-Chul;Park, Jinyoung;Kim, Chong-Myeong;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.252-256
    • /
    • 2017
  • PURPOSE. This in vitro study aimed to analyze and compare the reproducibility of zirconia and lithium disilicate crowns manufactured by digital workflow. MATERIALS AND METHODS. A typodont model with a prepped upper first molar was set in a phantom head, and a digital impression was obtained with a video intraoral scanner (CEREC Omnicam; Sirona GmbH), from which a single crown was designed and manufactured with CAD/CAM into a zirconia crown and lithium disilicate crown (n=12). Reproducibility of each crown was quantitatively retrieved by superimposing the digitized data of the crown in 3D inspection software, and differences were graphically mapped in color. Areas with large differences were analyzed with digital microscopy. Mean quadratic deviations (RMS) quantitatively obtained from each ceramic group were statistically analyzed with Student's t-test (${\alpha}=.05$). RESULTS. The RMS value of lithium disilicate crown was $29.2\;(4.1){\mu}m$ and $17.6\;(5.5){\mu}m$ on the outer and inner surfaces, respectively, whereas these values were $18.6\;(2.0){\mu}m$ and $20.6\;(5.1){\mu}m$ for the zirconia crown. Reproducibility of zirconia and lithium disilicate crowns had a statistically significant difference only on the outer surface (P<.001). The outer surface of lithium disilicate crown showed over-contouring on the buccal surface and under-contouring on the inner occlusal surface. The outer surface of zirconia crown showed both over- and under-contouring on the buccal surface, and the inner surface showed under-contouring in the marginal areas. CONCLUSION. Restoration manufacturing by digital workflow will enhance the reproducibility of zirconia single crowns more than that of lithium disilicate single crowns.

Changes in longitudinal craniofacial growth in subjects with normal occlusions using the Ricketts analysis

  • Bae, Eun-Ju;Kwon, Hye-Jin;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.44 no.2
    • /
    • pp.77-87
    • /
    • 2014
  • Objectives: This study was designed to define the Korean norm values for the Ricketts analysis. Methods: In this longitudinal study, lateral cephalograms of 31 subjects with normal occlusion were taken biennially from ages 9-19 years. Cephalometric measurements were performed. Parameters for which the 10-year change did not exceed one standard deviation were defined as unchanged. The means and standard deviations for the measured parameters were determined for each age group. Results: No significant changes in growth were observed in the molar relationship, incisor overjet, incisor overbite, mandibular incisor extrusion, interincisor angle, lower incisor tip (B1) to A point-Pogonion (A-PO) plane, upper incisor tip (A1) to A-PO plane, B1 inclination to A-PO, A1 inclination to A-PO, B1 inclination to Frankfurt plane (FH), convexity, lower facial height, facial axis, maxillary depth, maxillary height, palatal plane to FH, cranial deflection, ramus Xi position, or porion location. Continual changes over the 10 years of growth were observed in the maxillary first molar distal position to pterygoid true vertical plane, facial depth, mandibular plane to FH, anterior cranial length, mandibular arc, and corpus length. Conclusions: Clinicians can apply the Korean norms at age 9 as determined in this study when using the Ricketts analysis. The patient's age at the beginning of treatment and their sex should be taken into consideration when drawing visual treatment objectives.

Optimization and Elucidation of Esterification between Adipic Acid and 1,4-Butane Diol (Adipic acid와 1,4-butane diol의 에스테르화 반응 최적화 및 반응기작 규명)

  • Chung, Suk-Jin;Park, Soo-Nam
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.399-404
    • /
    • 2003
  • Aliphatic polyester, especially poly(butylene adipate)(PBA), is quite biodegradable and one of the most promising polymer materials to be commercialized. Bis(4-hydroxybutyl) adipate (BHBA) formation stage is the first principal process in the production of PBA from adipic acid (AA) and 1,4-butane diol (BD). In this study, we investigated for the effective production of Bis(4-hydroxybutyl) adipate (BHBA), effects of molar ratio of adipic acid (AA) to 1,4-butane diol (BD), catalyst (tetrabutyl titanate, TBT) concentration, and temperature on the reaction rate of esterification between AA and BD were investigated. Initial reaction rate of the esterification decreased with increasing molar ratio of AA to BD and reaction temperature, whereas reaction constant increased with increase in catalyst-concentration. Activation energy values for catalyzed and uncatalyzed esterifications were 198.5 and 94.8 kJ/mol, respectively.

A two-short-implant-supported molar restoration in atrophic posterior maxilla: A finite element analysis

  • Song, Ho-Yong;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.4
    • /
    • pp.304-312
    • /
    • 2016
  • PURPOSE. The aim of this study was to investigate the stress distribution of 2-short implants (2SIs) installed in a severely atrophic maxillary molar site. MATERIALS AND METHODS. Three different diameters of internal connection implants were modeled: narrow platform (NP), regular platform (RP), and wide platform (WP). The maxillary first molars were restored with one implant or two short implants. Three 2SI models (NP-oblique, NP-vertical, and NP-horizontal) and four single implant models (RP and WP in a centered or cantilevered position) were used. Axial and oblique loadings were applied on the occlusal surface of the crown. The von Mises stress values were measured at the bone-implant, peri-implant bone, and implant/abutment complex. RESULTS. The highest stress distribution at the bone-implant interface and the peri-implant bone was noticed in the RP group, and the lowest stress distribution was observed in the 2SI groups. Cantilevered position showed unfavorable stress distribution with axial loading. 2SI types did not affect the stress distribution in oblique loading. The number and installation positions of the implant, rather than the bone level, influenced the stress distribution of 2SIs. The implant/abutment complex of WP presented the highest stress concentration while that of 2SIs showed the lowest stress concentration. CONCLUSION. 2SIs may be useful for achieving stable stress distribution on the surrounding bone and implant-abutment complex in the atrophic posterior maxilla.

Three Dimensional Finite Element Analysis on ITI Implant Supported Fixed Partial Dentures with Various Fitting Accuracy (적합도에 따른 ITI 임플란트 지지 고정성 국소의치의 삼차원 유한요소 분석)

  • Choi, Min-Ho;Lee, Il-Kwon;Kim, Yu-Ree;Cho, Hye-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.1
    • /
    • pp.75-87
    • /
    • 2006
  • The purpose of this study was to investigate the effects of prostheses misfit, cantilever on the stress distribution in the implant components and surrounding bone using three dimensional finite element analysis. Two standard 3-dimensional finite element models were constructed: (1) 3 ITI implant supported, 3-unit fixed partial denture and (2) 3 ITI implant supported, 3-unit fixed partial denture with a distal cantilever. variations of the standard finite element models were made by placing a $100{\mu}m$ or $200{\mu}m$ gap between the fixture, the abutment and the crown on the second premolar and first molar. Total 14 models were constructed. In each model, 244 N of vertical load and 244 N of $30^{\circ}$ oblique load were placed on the distal marginal ridge of the distal molar. von Mises stresses were recorded and compared in the crowns, abutments, crestal compact bones, and trabecular bones. The results were obtained as follows: 1. In the ITI implant system, cement-retained prostheses showed comparatively low stress distributions on all the implant components and fixtures regardless of the misfit sizes under vertical loading. The stresses were increased twice under oblique loading especially in the prostheses with cantilever, but neither showed the effects of misfit size. 2. Under the oblique loading and posterior cantilever, the stresses were highly increased in the crestal bones around ITI implants, but effects of misfit were not shown. Although higher stresses were shown on the apical portion of trabecular bones, the effects by misfit were little and the stresses were increased by the posterior cantilever. 3. When the cement loss happened in the ITI implant supported FPD with misfit, the stresses were increased in the implant componets and supporting structures.

PERIAPICAL TISSUE REACTION AND ROOT RESORPTION FOLLOWING REPLANTATION WITH DIFFERENT CALCIUM HYDROXIDE PASTES IN RAT (치아재식술 시 근관충전재로 사용된 수산화칼슘 제재의 치근단 조직 반응 및 치근 흡수의 평가)

  • 송상채;이승종;정일영;이찬영;금기연
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.2
    • /
    • pp.111-120
    • /
    • 2001
  • Calcium hydroxide pastes is widely used in conventional endodontics. Along with the expanded clinical use of calcium hydroxide, literatures suggest mixing calcium hydroxide with other substance. Among added substances the vehicle plays the most importance role in the overall process because it is directly related with the velocity of ionic dissociation of $Ca^{2+}$ and OH ion. In this study, we evalutated and compared periapical tissue response and root resorption after canal was filled with mixture of saline and calcium hydroxide(Junsei Chemical Co.. Japan) as a aqueous vehicle, Metapaste(Meta Co., Korea) as a viscous vehicle paste, Vitapex(Neo Dental, Japan) as a oily vehicle paste and IRM(Caulk Dentsply, USA) in replantation of rat molar. A total of 31 maxillary first molars of Sprague-Dawley female rats, 30 days old were used. The upper 1st molar was extracted and the mesiobuccal canal was filled with mixture of saline and calcium hydroxide, Metapaste, Vitapex. IRM and then replanted. Rats were sacrificed 3 weeks after replantation. the maxillae were removed. section of 4 micron were cut and stained with hematoxylin-eosin, Apical tissue response were observed under light microscope. The results were as follows: 1. Saline mixing group and Metapaste group were significant different in fibrous capsule width compared to Vitapex group and IRM group(P<0.05). 2. Saline mixing group. Metapaste group. Vitapex group and IRM group did not prevent root resorption and there were no statistical difference. 3. In saline mixing group and Metapaste group. loss of pastes were observed in all samples. From the results of our study. we observed loss of pastes in saline mixing group and Metapaste group because of water soluble property and assumed it was related to inflammation in apical area and sealing ability of material. So, we should study and develop calcium hydroxide vehicle which is easily removed and more stable and because of only 3 weeks observation we need more evaluation in long period.

  • PDF

Comparative assessment of antibacterial activity of different glass ionomer cements on cariogenic bacteria

  • Naik, Rahul Gaybarao;Dodamani, Arun Suresh;Khairnar, Mahesh Ravindra;Jadhav, Harish Chaitram;Deshmukh, Manjiri Abhay
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.4
    • /
    • pp.278-282
    • /
    • 2016
  • Objectives: Glass ionomer cements (GICs), which are biocompatible and adhesive to the tooth surface, are widely used nowadays for tooth restoration. They inhibit the demineralization and promote the remineralization of the tooth structure adjacent to the restoration, as well as interfere with bacterial growth. Hence, the present study was conducted to assess and compare the antimicrobial activity of three commercially available GICs against two cariogenic bacteria. Materials and Methods: An agar plate diffusion test was used for evaluating the antimicrobial effect of three different GICs (Fuji IX, Ketac Molar, and d-tech) on Streptococcus mutans (S. mutans) and Lactobacillus acidophilus (L. acidophilus). Thirty plates were prepared and divided into two groups. The first group was inoculated with S. mutans, and the second group was inoculated with L. acidophilus. These plates were then incubated at $37^{\circ}C$ for 24 hours. Zones of bacterial growth inhibition that formed around each well were recorded in millimeters (mm). Results: The zones of inhibition for Fuji IX, Ketac Molar, and d-tech on S. mutans were found to be $10.84{\pm}0.22mm$, $10.23{\pm}0.15mm$, and $15.65{\pm}0.31mm$, respectively, whereas those for L. acidophilus were found to be $10.43{\pm}0.12mm$, $10.16{\pm}0.11mm$, and $15.57{\pm}0.13mm$, respectively. Conclusions: D-tech cement performed better in terms of the zone of bacterial inhibition against the two test bacteria, than the other two tested glass ionomers.

Effect of irradiation on the healing of extraction sockets in diabetic rats (방사선조사가 당뇨 백서의 발치와 치유에 미치는 영향)

  • Kim Il-Joong;Hwang Eui-Hwan;Lee Sang-Rae
    • Imaging Science in Dentistry
    • /
    • v.33 no.1
    • /
    • pp.5-14
    • /
    • 2003
  • Purpose: To observe the histologic pattern of healing in molar tooth extraction sockets of streptozotocin-induced diabetic rats following irradiation. Materials and Methods: Mature Sprague-Dawley rats were divided into three groups: control, diabetic, and diabetic-irradiated groups. Diabetes mellitus was induced by injecting streptozotocin. Control rats were injected with a citrate buffer only. After 5 days, the right maxillary first molar was extracted under general anesthesia from each of the rats. After the extraction, rats in the diabetic-irradiated group were irradiated with a single absorbed dose of 10 Gy to the head and neck region. The rats were killed at 1, 3, 7, 14, 21, and 28 days after treatment. Tissue sections were stained with hematoxylin-eosin and Masson's trichrome. Results: In the diabetic and diabetic-irradiated groups, the early healing process of the socket extraction was similar to the control group, but bone formation was delayed at 7 days after the treatment. In the diabetic-irradiated group, alveolar bone surrounding the extraction socket showed signs of necrosis at 3 days after treatment, and hemorrhage was observed in connective tissue within the extraction socket at 14 days after treatment. Conclusion: This experiment revealed that the healing process of the extraction socket was severely delayed and retarded by irradiation in the diabetic state.

  • PDF

THE BALANCE OF OCCLUSAL CONTATS IN NORMAL OCCLUSION DURING INTERCUSPAL POSITION ON T-SCAN SYSTEM (T-Scan System을 이용한 성인 정상교합자의 교두감합위에서 교합안정에 관한 연구)

  • Pahng, Won-Dong;Woo, Yi-Hyung;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.1
    • /
    • pp.23-37
    • /
    • 1991
  • The understanding the natureof occlusal tooth contacts of natural dentition is important for correct diagnosis and treatment of diseases developed in stomatognatic system. Several investigator have studied the distribution of tooth contacts in maximum intercuspation and have reported contact locations with respect to the tooth position. Many methods have been clinically applied for the occlusal analysis in the intercuspal position. However, there are few quantative methods. This study analyzed the new software version of the T-Scan system to record and analyze occlusal contact balance in the anterior-posterior and right-left directions. Six time moment statistics and five moment statistics were calculated in the midsagittal and the incisal axes of the occlusal plane. In the present study, informed consent was obtained from 100 subjects with natural dentitions. The results were as follows ; 1. The mean of the dental arch length & width were 48.78, 65.32mm in whole population, 49.09mm, 65.50mm in males, 48.78mm, 64.63mm in females, respectively. 2. The mean of TLR & PLR were 0.193mm(left), 0.311mm(left), respectively. Therefore, the distribution of tooth contacts was bilaterally symmetric. 3. The mean of TFB & PFB were 29.168mm, 29.055mm, and that of LFB & RFB were 29.627mm, 29.587mm, respectively, and the qualitative center of occlusal contacts was the firtst molar. 4. The mean of LL & RL were 31.666mm, 31.377mm, respectively, and the quantitative center of occlusal force was the first molar. 5. The mean of LF & RF were 60.237N, 59.276N, respectively and Left-right moment was 72.491Nmm. Therfore, the distribution of occlusal force was bilaterally balanced.

  • PDF