• Title/Summary/Keyword: First molar

Search Result 1,022, Processing Time 0.035 seconds

DELAYED ERUPTION OF MADIBULAR FIRST MOLAR BY ERUPTED COMPLEX ODONTOMA (Erupted complex odontoma에 의한 하악 제 1대구치 맹출지연)

  • Park, In-Ho;Oh, You-Hyang;Lee, Sang-Ho;Lee, Chang-Seop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.564-568
    • /
    • 2004
  • Odontoma, hamartomas of odontogenic orgin, are composed of all the structures that make up teeth, which may lead to interference with the eruption of its associated tooth. On the basis of gross, radiographic, and microscopic features, two types of odontoma are recognized: compound and complex. The etilogy of odontomas is unknown, although local trauma, infection, and gentic factors have been suggested. Odontomas occur central in bone between the roots of teeth and the mauority are asymptomatic. Although these tumors occur frequently and constitute 22% of all odontogenic tumors, are very rare. Erupted odontoma are defined as tumors that it occurs a calcifed mass may be defected on the ridge. The treatment of chico is the surgical removal of the lesion followed by a biopsy. This report presents a case of 8-year-old girl with the delayed eruption of the mandibular first molar by the calcified mass within the operculum covered the central fossa. And it was diagnosed as erupted complex odontoma by excisional biopsy.

  • PDF

3-DIMENSIONAL FINITE ELEMENT ANALYSIS ON THE INFRAOCCLUSION OF FIXED IMPLANT PROSTHESIS FOR PARTIAL EDENTULISM (부분 무치악의 고정성 임플랜트 보철의 저위교합에 관한 3차원 유한요소법적 연구)

  • Kim, In-Seob;Choi, Choong-Kug;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.3
    • /
    • pp.632-649
    • /
    • 1996
  • The purpose of this study was to examine, by the method of 3-dimentional finite element analysis. how infraocclusion affected the stress distribution in surrounding bone and osseointegrated prosthesis. The 3-dimentional finite element mandibular models were made, in which the first and second molars were removed and the two osseointegrated implants were placed in the first and second molar sites and implant supported fixed prostheses were constructed. Analysis of equivalent stress and displacement induced by strong occlusion or infraocclusion was performed under vertical or inclined distributed loads. The results were as follows; 1. Under vertical load of 50N or 500N, the model in which infraocclusion had not been allowed showed greater stress on implants and the supporting bone than on natural teeth. 2. In the model in which infraocclusion of $30{\mu}m$ had been allowed, implant-prosthesis on the molars had no contact with opposing teeth under vertical load of 50N, However with the same allowed infraocclusion and the model under vertical load of 500N, implant prosthesis on the second molar had contact with opposing teeth, and stress distribution occured properly on natural teeth and implants. 3. Under $45^{\circ}$ inclined load, the model in which infraocclusion had not been allowed showed greater stress on implants and the supporting bone than on natural teeth. There was greater stress in the case of $45^{\circ}$ inclined load than in the case of vertical load. 4. Under $45^{\circ}$ inclined load of 50N or 500N, the model in which infraocclusion of $30{\mu}m$, had been allowed showed no occlusal contact on the implants and occlusal contact on the natural teeth. 5. In partially edentulous cases with implant supported prosthesis, we can prevent excessive load on implants by allowing infraocclusion.

  • PDF

Advantages of anterior inferior alveolar nerve block with felypressin-propitocaine over conventional epinephrine-lidocaine: an efficacy and safety study

  • Shinzaki, Hazuki;Sunada, Katsuhisa
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.15 no.2
    • /
    • pp.63-68
    • /
    • 2015
  • Background: Conventional anesthetic nerve block injections into the mandibular foramen risk causing nerve damage. This study aimed to compare the efficacy and safety of the anterior technique (AT) of inferior alveolar nerve block using felypressin-propitocaine with a conventional nerve block technique (CT) using epinephrine and lidocaine for anesthesia via the mandibular foramen. Methods: Forty healthy university students with no recent dental work were recruited as subjects and assigned to two groups: right side CT or right side AT. Anesthesia was evaluated in terms of success rate, duration of action, and injection pain. These parameters were assessed at the first incisor, premolar, and molar, 60 min after injection. Chi-square and unpaired t-tests were used for statistical comparisons, with a P value of < 0.05 designating significance. Results: The two nerve block techniques generated comparable success rates for the right mandible, with rates of 65% (CT) and 60% (AT) at both the first molar and premolar, and rates of 60% (CT) and 50% (AT) at the lateral incisor. The duration of anesthesia using the CT was $233{\pm}37min$, which was approximately 40 min shorter than using the AT. This difference was statistically significant (P < 0.05). Injection pain using the AT was rated as milder compared with the CT. This difference was also statistically significant (P < 0.05). Conclusions: The AT is no less successful than the CT for inducing anesthesia, and has the added benefits of a significantly longer duration of action and significantly less pain.

Effects of the endodontic access cavity on apical debris extrusion during root canal preparation using different single-file systems

  • Tufenkci, Pelin;Yilmaz, Koray;Adiguzel, Mehmet
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.3
    • /
    • pp.33.1-33.10
    • /
    • 2020
  • Objectives: This study was conducted to evaluate the effects of traditional and contracted endodontic cavity (TEC and CEC) preparation with the use of Reciproc Blue (RPC B) and One Curve (OC) single-file systems on the amount of apical debris extrusion in mandibular first molar root canals. Materials and Methods: Eighty extracted mandibular first molar teeth were randomly assigned to 4 groups (n = 20) according to the endodontic access cavity shape and the single file system used for root canal preparation (reciprocating motion with the RCP B and rotary motion with the OC): TEC-RPC B, TEC-OC, CEC-RPC B, and CEC-OC. The apically extruded debris during preparation was collected in Eppendorf tubes. The amount of extruded debris was quantified by subtracting the weight of the empty tubes from the weight of the Eppendorf tubes containing the debris. Data were analyzed using 1-way analysis of variance with the Tukey post hoc test. The level of significance was set at p < 0.05. Results: The CEC-RPC B group showed more apical debris extrusion than the TEC-OC and CEC-OC groups (p < 0.05). There were no statistically significant differences in the amount of apical debris extrusion among the TEC-OC, CEC-OC, and TEC-RPC B groups. Conclusions: RPC B caused more apical debris extrusion in the CEC groups than did the OC single-file system. Therefore, it is suggested that the RPC B file should be used carefully in teeth with a CEC.

In-vitro assessment of the accuracy and reliability of mandibular dental model superimposition based on voxel-based cone-beam computed tomography registration

  • Han, Gaofeng;Li, Jing;Wang, Shuo;Liu, Yan;Wang, Xuedong;Zhou, Yanheng
    • The korean journal of orthodontics
    • /
    • v.49 no.2
    • /
    • pp.97-105
    • /
    • 2019
  • Objective: This study was performed to evaluate the accuracy and reliability of a newly designed method to achieve mandibular dental model superimposition, using voxel-based cone-beam computed tomography (CBCT) registration. Methods: Fourteen dry cadaveric mandibles and six teeth extracted from patients with severe periodontitis were used to establish 14 orthodontic tooth-movement models. The protocol consisted of two steps: in the first step, voxel-based CBCT mandible superimposition was performed; the reference comprised the external portion of the symphysis, extending to the first molar. The laser-scanned dental model image was then integrated with the CBCT image to achieve mandibular dental model superimposition. The entire process required approximately 10 minutes. Six landmarks were assigned to the teeth to measure tooth displacement, using tooth displacement on the superimposed laser-scanned mandibles as the reference standard. Accuracy was evaluated by comparing differences in tooth displacement based on the method and the reference standard. Two observers performed superimposition to evaluate reliability. Results: For three-dimensional tooth displacements, the differences between the method and the reference standard were not significant in the molar, premolar, or incisor groups (p > 0.05). The intraclass correlation coefficients for the inter- and intra-observer reliabilities of all measurements were > 0.92. Conclusions: Our method of mandibular dental model superimposition based on voxel registration is accurate, reliable, and can be performed within a reasonable period of time in vitro, demonstrating a potential for use in orthodontic patients.

Three-dimensional finite element analysis of buccally cantilevered implant-supported prostheses in a severely resorbed mandible

  • Alom, Ghaith;Kwon, Ho-Beom;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.12-23
    • /
    • 2021
  • Purpose. The aim of the study was to compare the lingualized implant placement creating a buccal cantilever with prosthetic-driven implant placement exhibiting excessive crown-to-implant ratio. Materials and Methods. Based on patient's CT scan data, two finite element models were created. Both models were composed of the severely resorbed posterior mandible with first premolar and second molar and missing second premolar and first molar, a two-unit prosthesis supported by two implants. The differences were in implants position and crown-to-implant ratio; lingualized implants creating lingually overcontoured prosthesis (Model CP2) and prosthetic-driven implants creating an excessive crown-to-implant ratio (Model PD2). A screw preload of 466.4 N and a buccal occlusal load of 262 N were applied. The contacts between the implant components were set to a frictional contact with a friction coefficient of 0.3. The maximum von Mises stress and strain and maximum equivalent plastic strain were analyzed and compared, as well as volumes of the materials under specified stress and strain ranges. Results. The results revealed that the highest maximum von Mises stress in each model was 1091 MPa for CP2 and 1085 MPa for PD2. In the cortical bone, CP2 showed a lower peak stress and a similar peak strain. Besides, volume calculation confirmed that CP2 presented lower volumes undergoing stress and strain. The stresses in implant components were slightly lower in value in PD2. However, CP2 exhibited a noticeably higher plastic strain. CONCLUSION. Prosthetic-driven implant placement might biomechanically be more advantageous than bone quantity-based implant placement that creates a buccal cantilever.

Effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing: An in vitro study

  • Lee, Beom-Il;You, Seung-Gyu;You, Seung-Min;Kang, Seen-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.24-35
    • /
    • 2021
  • PURPOSE. This study was to evaluate the effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing. MATERIALS AND METHODS. The maxillary right first molar master die was duplicated using a silicone material, while a study die was produced using epoxy resin. Scans of the epoxy resin die were used in combination with CAD software to design a maxillary right first molar interim crown. Based on this design, 24 interim crowns were fabricated with digital light processing. This study examined the trueness and precision of products that were processed with one of the three different postprocessing rinsing times (1 min, 5 min, and 10 min). Trueness was measured by superimposing reference data with scanned data from external, intaglio, and marginal surfaces. Precision was measured by superimposing the scan data within the group. The trueness and precision data were analyzed using Kruskal-Wallis, nonparametric, and post-hoc tests, and were compared using a Mann-Whitney U test with Bonferroni correction (α=.05). RESULTS. The trueness of the external and intaglio surfaces of crowns varied significantly among the different rinsing times (P=.004, P=.003), but there was no statistically significant difference in terms of trueness measurements of the marginal surfaces (P=.605). In terms of precision, statistically significant differences were found among the external, intaglio, and marginal surfaces (P=.001). CONCLUSION. Interim crowns rinsed for 10 minutes showed high accuracy.

Age Estimation with Panoramic Radiomorphometric Parameters Using Generalized Linear Models

  • Lee, Yeon-Hee;An, Jung-Sub
    • Journal of Oral Medicine and Pain
    • /
    • v.46 no.2
    • /
    • pp.21-32
    • /
    • 2021
  • Purpose: The purpose of the present study was to investigate the correlation between age and 34 radiomorphometric parameters on panoramic radiographs, and to provide generalized linear models (GLMs) as a non-invasive, inexpensive, and accurate method to the forensic judgement of living individual's age. Methods: The study included 417 digital panoramic radiographs of Korean individuals (178 males and 239 females, mean age: 32.57±17.81 years). Considering the skeletal differences between the sexes, GLMs were obtained separately according to sex, as well as across the total sample. For statistical analysis and to predict the accuracy of the new GLMs, root mean squared error (RMSE) and adjusted R-squared (R2) were calculated. Results: The adjusted R2-values of the developed GLMs in the total sample, and male and female groups were 0.623, 0.637, and 0.660, respectively (p<0.001), while the allowable RMSE values were 8.80, 8.42, and 8.53 years, respectively. In the GLM of the total sample, the most influential predictor of greater age was decreased pulp area in the #36 first molar (beta=-26.52; p<0.01), followed by the presence of periodontitis (beta=10.24; p<0.01). In males, the most influential factor was the presence of periodontitis (beta=9.20; p<0.05), followed by the number of full veneer crowns (beta=2.19; p<0.001). In females, the most influential predictor was the presence of periodontitis (beta=18.10; p<0.001), followed by the tooth area of the #16 first molar (beta=-11.57; p<0.001). Conclusions: We established acceptable GLM for each sex and found out the predictors necessary to age estimation which can be easily found in panoramic radiographs. Our study provides reference that parameters such as the area of tooth and pulp, the number of teeth treated, and the presence of periodontitis should be considered in estimating age.

3D quantitative analysis and SEM qualitative analysis of natural antagonist enamel opposing CAD-CAM monolithic zirconia or lithium disilicate tooth-supported crowns versus enamel opposing natural enamel

  • Piyarat Woraganjanaboon;Chuchai Anunmana
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.1
    • /
    • pp.12-24
    • /
    • 2024
  • PURPOSE. This study aimed to evaluate the maximum vertical wear, volume wear, and surface characteristic of antagonist enamel, opposing monolithic zirconia or lithium disilicate crowns. MATERIALS AND METHODS. The study comprised 24 participants (n = 12), who were randomly allocated to receive either a 5 mol% Y-TZP or a lithium disilicate crown in positions which would oppose the natural first molar tooth. The contralateral first molar along with its antagonist was considered as the enamel opposing natural enamel control. Data collection was performed using an intraoral scanner and polyvinylsiloxane impression. The means of the maximum vertical loss and the volume loss at the occlusal contact areas of the crowns and the various natural antagonists were measured by 3D comparison software. A scanning electron microscope was subsequently used to assess the wear characteristics. RESULTS. The one-year results from 22 participants (n = 11) indicated no significant differences when comparing the zirconia crown's antagonist enamel (40.28 ± 9.11 ㎛, 0.04 ± 0.02 mm3) and the natural enamel wear (38.91 ± 7.09 ㎛, 0.04 ± 0.02 mm3) (P > .05). Also, there is no significant differences between lithium disilicate crown's antagonist enamel (47.81 ± 9.41 ㎛, 0.04 ± 0.02 mm3) and the natural enamel wear (39.11 ± 7.90 ㎛, 0.04 ± 0.02 mm3) (P > .05). CONCLUSION. While some studies suggested that monolithic zirconia caused less wear on opposing enamel than lithium disilicate, this study found similar wear levels to enamel for both materials compared to natural teeth.

Distribution of the intraosseous branch of the posterior superior alveolar artery relative to the posterior maxillary teeth

  • Carsen R. McDaniel;Thomas M. Johnson;Brian W. Stancoven;Adam R. Lincicum
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.121-127
    • /
    • 2024
  • Purpose: Preoperative identification of the intraosseous posterior superior alveolar artery (PSAA) is critical when planning sinus surgery. This study was conducted to determine the distance between the cementoenamel junction and the PSAA, as well as to identify factors influencing the detection of the PSAA on cone-beam computed tomography (CBCT). Materials and Methods: In total, 254 CBCT scans of maxillary sinuses, acquired with 2 different scanners, were examined to identify the PSAA. The distance from the cementoenamel junction (CEJ) to the PSAA was recorded at each maxillary posterior tooth position. Binomial logistic regression and multiple linear regression were employed to evaluate the effects of scanner type, CBCT parameters, sex, and age on PSAA detection and CEJ-PSAA distance, respectively. P-values less than 0.05 were considered to indicate statistical significance. Results: The mean CEJ-PSAA distances at the second molar, first molar, second premolar, and first premolar positions were 17.0±4.0 mm, 21.8±4.1 mm, 19.5±4.7 mm, and 19.9±4.9 mm for scanner 1, respectively, and 17.3±3.5 mm, 16.9±4.3 mm, 18.5±4.1 mm, and 18.4±4.3 mm for scanner 2. No independent variable significantly influenced PSAA detection. However, tooth position (b=-0.67, P<0.05) and scanner type (b=-1.3, P<0.05) were significant predictors of CEJ-PSAA distance. Conclusion: CBCT-based estimates of CEJ-PSAA distance were comparable to those obtained in previous studies involving cadavers, CT, and CBCT. The type of CBCT scanner may slightly influence this measurement. No independent variable significantly impacted PSAA detection.