• Title/Summary/Keyword: First molar

Search Result 1,022, Processing Time 0.024 seconds

Comparison of marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures fabricated from solid working casts and working casts from a removable die system (가철성 다이 시스템으로 제작된 작업 모형과 솔리드 작업 모형 상에서 제작된 지르코니아 3본 고정성 치과 보철물의 변연 및 내면 적합도 비교)

  • Wan-Sun Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.72-81
    • /
    • 2024
  • Purpose: This study aimed to assess the marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures (FPDs) fabricated via computer-aided design and computer-aided manufacturing (CAD/CAM) from solid working casts and removable die system. Materials and Methods: The tooth preparation protocol for a zirconia crown was executed on the mandibular right first premolar and mandibular right first molar, with the creation of a reference cast featuring an absent mandibular right second premolar. The reference cast was duplicated using polyvinyl siloxane impression, from which 20 working casts were fabricated following typical dental laboratory procedures. For comparative analysis, 10 FPDs were produced from a removable die system (RD group) and the remaining 10 FPDs from the solid working casts (S group). The casts were digitized using a dental desktop scanner to establish virtual casts and design the FPDs using CAD. The definitive 3-unit monolithic zirconia FPDs were fabricated via a CAM milling process. The seated FPDs on the reference cast underwent digital evaluation for marginal and internal fit. The Mann-Whitney U test was applied for statistical comparison between the two groups (α = 0.05). Results: The RD group showed significantly higher discrepancies in fit for both premolars and molars compared to the S group (P < 0.05), particularly in terms of marginal and occlusal gaps. Color mapping also highlighted more significant deviations in the RD group, especially in the marginal and occlusal regions. Conclusion: The study found that the discrepancies in marginal and occlusal fits of 3-unit monolithic zirconia FPDs were primarily associated with those fabricated using the removable die system. This indicates the significant impact of the fabrication method on the accuracy of FPDs.

Effects of Horseshoe Expander (Horseshoe Expander의 확장 효과에 관한 연구)

  • Chung, Kyu-Rhim;Park, Young-Guk;Lee, Young-Jun;Kim, Hong-Suk
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.553-563
    • /
    • 2000
  • Horseshoe Expander is one of Slow Maxillary Expansion(SME) which aims to accommodate the contra- lateral expansion and midpalatal suture expansion or the palate. The appliance consists of skeleton type strew embedded in split Horseshoe appliance. It is the objectives of the presentation to manifest the changes in dental & craniofacial components subsequent to the application of Horseshoe Expander. The subjects for this study consisted of 32 patients (mean age : 12.7). frontal, lateral cephalometric headfilm were taken and study casts were fabricated before and after expansion. 24 items were measured, compared preexpansion with postexpansion. Especially, palatal volume was measured by means of 'Hydro-measurement method'. Tooth axis measurement on the dental casts were made with Universal bevel protractor, and Horseshoe Expander group were compared with RME group. This study of changes to maxillary expansion with Horseshoe Expander revealed the following significant results. 1. Triangular-shaped expansion pattern appeared in frontal cephalometric headfilm. 2. Palatal plane, occlusal plane, mandibular plane and upper incisor to FH increased in lateral cephalometrir headfilm. 3. Palatal volume increased significantly. A slight bite opening, reduction of occlusal contact points showed in dental casts. 4. A 2.2:1 ratio of the amount of intermolar width in maxilla(orthodontic movement) to maxillary width (orthopedic movement) was determined. 5. Horseshoe Expander group has less buccal tipping tendency than RME group, by taking high correlation coefficients in the upper second premolar and first molar. It was suggested that Horseshoe Expander showed less orthodontic changes, less buccal tipping tendency. In addition, it was effective in maxillary expansion.

  • PDF

A study on the preorthodontic prediction values versus the actual postorthodontic values in Class III surgery patients (골격성 III급 부정교합 환자에서 술전 교정전 예측치와 교정 후 실측치의 차이에 관한 연구)

  • Hwang, Chung-Ju;Kwon, Hee-Jeong
    • The korean journal of orthodontics
    • /
    • v.33 no.1 s.96
    • /
    • pp.1-9
    • /
    • 2003
  • The purpose of this study was to find out and evaluate discrepancies between preorthodontic prediction values and actual postorthodontic values and factors contributing to it in 45 patients(17 male, 28 female) who were diagnosed as skeletal Class III ma)occlusion and received presurgical orthodontic treatment and orthognathic surgery at Yonsei university dental hospital. Lateral cephalograms were analysed at pretreatment(T1), orthodontic Prediction(T2), immediately before surgery(T3) and designated the landmark as coordinates or X and Y axes. The samples were divided according to ALD, upper and lower incisor inclination(Ul to SN, IMPA), COS, extraction, the position of extracted teeth and the statistical significance was tested to find out the factors contributing to the prediction. The results were as follows: 1. Differences between preorthodontic prediction values and actual postorthodontic values(T2-T3) were statistically significant(p<0.05) in the x coordinates of U6mbc, L1x and in y coordinates of U1i, U1x, U6me, U6mbc, L6mbc 2. The accuracy of prediction is relatively higher in horizontal changes compared to vortical changes. 3. The statistical significance(p<0.05) between prediction and actual values is observed more in the landmarks of the maxilla than the mandible. 4. Differences between prediction and actual values of incisor and first molar were statistically significant(p<0.05) according to extraction vs non-extraction, extraction type, ALD in the maxilla and according to ALD, IMPA in the mandible. Discrepancies between preorthodontic prediction values and actual postorthodontic values and factors contributing to the prediction must be considered in treatment planning of Cl III surgical patients to increase the accuracy of prediction. Furthermore future investigations are needed on the prediction of vortical changes.

Effect of orthodontic force on the amount of tooth movement and root resolution in rat (교정력이 흰쥐의 치아이동량과 치근흡수에 미치는 영향)

  • Kim, Il-Gon;Kim, Kwang-Won;Yoon, Young-Jooh
    • The korean journal of orthodontics
    • /
    • v.29 no.5 s.76
    • /
    • pp.551-562
    • /
    • 1999
  • This study was undertaken to investigate the relation between orthodontic force magnitude and the amount of tooth movement. And more light force application for reducing root resorption Twenty-four rats were divided into three experimental groups(A, B, C) based on force magnitude and application method. Springs of 50g force were applied to A group, springs of 100g force were applied to B group and springs of 25g force were applied to C group initially, and after 4 days springs of C group were changed to springs of 50g force. Two kinds of $sentally^{(R)}$(GAC U.S.A.) closed coil spring, 50g and 100g, were used. And we made 25g springs by heat treatment process of 50g springs. Each spring was inserted between the maxillary central incisor and the maxillary left first molar. Amounts of tooth movement were measured everyday by digital caliper($Digimatic^{(R)}$, Mitutoyo, Japan) under inhalation anesthesia for 15 days. After 15 days, all rats were sacrificed and histological samples were obtained with Hematoxyline-Eosin stain and Masson's trichrome stain. Following conclusion were made; 1. Group B showed the mean cumulative tooth movement of $2.19{\pm}0.41mm$ at 15th day, which was greatest among three groups, followed by group C($2.06{\pm}0.10mm$), group A($1.90{\pm}0.49mm$) respectively. however, there was no statistically difference among three groups. 2. All groups showed general tooth movement pattern and A, B, C group finished lag phase at 9th, 8th, 7th day, but there was no statistical significance. 3. Group A,B,C showed root resorption and especially group B showed the most severe root resorption and group C showed milder root resorption than other groups. According to the above results, large initial force with the development of a flirty widespread hyalinized zone may cause severe root resorption, so initial force should be applied lightly to reduce hyalinized area and eventually root resorption and then increased force will induce efficient tooth movement.

  • PDF

Three-dimensional finite element analysis of initial tooth displacement according to force application point during maxillary six anterior teeth retraction using skeletal anchorage (골격성 고정원을 이용한 상악 6전치 후방 견인시 힘의 적용점 변화에 따른 치아 이동 양상에 관한 유한 요소법적 분석)

  • Kim, Chan-Nyeon;Sung, Jae-Hyun;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.33 no.5 s.100
    • /
    • pp.339-350
    • /
    • 2003
  • The purpose of this study was to investigate the micro-implant height and anterior hook height to prevent maxillary six anterior teeth from lingual tipping and extruding during space closure. We manufactured maxillary dental arch form, bracket and wire, using the computer aided three-dimensional finite element method. Bracket was $.022'{\times}.028'$ slot size and attached to tooth surface. Wire was $.019'{\times}.025'$ stainless steel and $.032'{\times}.032'$ stainless steel hook was attached to wire between lateral incisor and canine. Length of hook was 8mm and force application points were marked at intervals of In. Four micro-implants were implanted on alveolar bone between second premolar and first molar. The heights of them were 4, 6, 8, 10mm starting from wire. We analyzed initial displacement of teeth by various force application point applying force of 150gm to each micro-implant and anterior hook. The conclusions of 4his study are as the following : 1. When the micro-implant height was 4m and the anterior hook height was 5mm and below, anterior teeth were tipped lingually. When the anterior hook height was 6mm and above, anterior teeth were tipped labially. 2. When the micro-implant height was 6mm and the anterior hook height was 6mm and below, the anterior teeth were tipped lingually. When the anterior hook height was 6m and above, the anterior teeth were tipped labially. But lingual tipping of anterior teeth decreased and labial tipping Increased when the micro-implant height was 6mm, compared with 4mm micro-implant height. 3. When the micro-implant height was 8mm and the anterior hook height was 2mm, the anterior teeth were tipped lingually. When the anterior hook height was 3mm and above, labial tipping movement of the anterior teeth increased proportionally. 4. When the micro-implant height was 10mm and the anterior hook height was 2mm and above, labial tipping of the anterior teeth increased proportionally. 5. As the anterior hook height increased, aterior teeth were tipped more labially. But extrusion occurred on canine and premolar area because of the increase of wire distortion. 6. Movement of the posterior teeth was tipped distally during maxillary six anterior teeth retraction using micro-im plant because of the friction between bracket and were Based on the results of this study, we could predict the pattern of the tooth movement according to position of micro-implant and height of anterior hook. It seems that we can find the force application point for proper tooth movement in consideration of inclination of anterior anterior teeth, periodontal condition, overjet and overbite

PULPAL AND PERIAPICAL REACT10N TO FORMOCRESOL AND DEPULPIN® IN THE RAT TEETH (백서에서 Depulpin®과 Formocresol에 대한 치수와 치근단 조직의 반응)

  • Moon, Hyung-In;Kim, Sun-Ho;Hwang, Yun-Chan;Oh, Byung-Ju;Hwang, In-Nam;Kim, Sun-Hun;Jeong, Sun-Wa;Youn, Chang;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.355-362
    • /
    • 2002
  • One fifth dilution of formocresol is usually used for pulpotomy of the primary teeth and emergency pulpotomy of the permanent teeth. However the use of formaldehyde has been subjected to criticism because it may be absorbed into the blood stream and become distributed systemically, it nay also alter the pulp tissue rendering it immunologically active, and have carcinogenic potential. Recently Depulpin$^{\circledR}$(VoCo., Germany) gains popularity as a devitalizing agent during root canal therapy in spite of high concentration of 49 % paraformaldehyde because it facilitate devitalization of pulp and make root canal therapy easier But there have been not enough publications about the reaction of pulp and periapical tissue caused by Depulpin. This study was performed to evaluate the histological changes in pulp and periapical tissue of rats after pulpotomy using formocresol and Depulpin and to elucidate the toxic effects of these agents. Thirty six Sprague-Dawley rats were anesthetized by intraperitoneal injection of ketamine Maxillary first molar teeth were used for pulpotomy with formocresol and Depulpin. Rats were sacrificed after 2 days, 4 days, 1 week, 2 weeks, 3 weeks and 4 weeks respectively. Specimens were histologically observed by light microscope changes in pulp and periapical tissue. The obtained results were as follows. 1. Formocresol group A zone of fixed tissue. in which odontoblasts could clearly be defined, was present directly underneath the pulpotomy dressing in almost all teeth of this group. This was followed by an area of necrotic tissue which resembled dried out fibrous tissue with no cellular detail except some pyknotic nuclei. In the specimens of after 2 days, 4 days, 1 week, 2 weeks in which vital tissue was present, it was separated from the fibrous area by a zone of inflammation. In the specimens of after 3 weeks and after 4 weeks, inflammatory infiltrate was in the periodontal ligament adjacent to the apical foramina of the teeth. 2. Depulpin$^{\circledR}$ group The area of necrotic tissue which had no cells and fibers, was present adjacent to the dressing. This was followed by dried out fibrous tissue with no cellular details except some pyknotic nuclei, A short stump of vital pulp with odontoblasts was present at the end of the canal after 2 days. Inflammatory infiltrate was in the periodontal ligament after 4 days and after 1week. Severe root resolution and necrosis of periapical tissue opposite the root resorption site were defined after 2 weeks and after 3 weeks. Periapical lesion which consist of necrotic tissue surrounded by a fibrous connective wall, was found after 4 weeks. The results indicated that Depulpin can cause more adverse reaction to the dental pulp and periapical tissue than formocresol, and further studies are needed for its clinical use with safety.

Evaluation of the stress distribution in the external hexagon implant system with different hexagon height by FEM-3D (임플란트 hexagon 높이에 따른 임플란트와 주위 조직의 응력분포 평가)

  • Park, Seong-Jae;Kim, Joo-Hyeun;Kim, So-Yeun;Yun, Mi-Jung;Ko, Sok-Min;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.36-43
    • /
    • 2012
  • Purpose: To analyze the stress distribution of the implant and its supporting structures through 3D finite elements analysis for implants with different hexagon heights and to make the assessment of the mechanical stability and the effect of the elements. Materials and methods: Infinite elements modeling with CAD data was designed. The modeling was done as follows; an external connection type ${\phi}4.0mm{\times}11.5mm$ Osstem$^{(R)}$ USII (Osstem Co., Pusan, Korea) implant system was used, the implant was planted in the mandibular first molar region with appropriate prosthetic restoration, the hexagon (implant fixture's external connection) height of 0.0, 0.7, 1.2, and 1.5 mm were applied. ABAQUS 6.4 (ABAQUS, Inc., Providence, USA) was used to calculate the stress value. The force distribution via color distribution on each experimental group's implant fixture and titanium screw was studied based on the equivalent stress (von Mises stress). The maximum stress level of each element (crown, implant screw, implant fixture, cortical bone and cancellous bone) was compared. Results: The hexagonal height of the implant with external connection had an influence on the stress distribution of the fixture, screw and upper prosthesis and the surrounding supporting bone. As the hexagon height increased, the stress was well distributed and there was a decrease in the maximum stress value. If the height of the hexagon reached over 1.2mm, there was no significant influence on the stress distribution. Conclusion: For implants with external connections, a hexagon is vital for stress distribution. As the height of the hexagon increased, the more effective stress distribution was observed.

THE PREVALENCE OF WHITE SPOT LESIONS ON THE MESIAL SURFACES OF THE 1ST MOLARS IN CHILDREN AND MINIMAL INVASIVE APPROACH - A PILOT STUDY (어린이 제1대구치 근심면 초기 우식의 유병률과 최소 침습적 접근)

  • Ahn, Myung-Ki;Lee, Geum-Lang;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.1
    • /
    • pp.102-107
    • /
    • 2009
  • In clinical pediatric dentistry, we have many chances to encounter the white spot like incipient enamel lesions on the mesial surfaces of the 1st molars with direct vision, especially just after the 2nd primary molars were exfoliated. But it was thought highly desirable to assess if these lesions are properly and effectively managed yet. This study aims at surveying the prevalence of incipient lesions on the mesial surfaces of the 1st molars in children through direct observation and examining the suitability of adhesive sealing on them as a pilot trial in searching for their proper management. 1. Among the 124 mesial surfaces of the 1st molars examined, 34% were sound, 53% had incipient carious lesions and 13% had cavitated lesions. 2. In the sectional views of the specimens, 20% showed microleakage after thermo-cycling and it was thought not recommendable as a permanent method. Therefore in order to effectively fight against the incipient caries lesions in children‘s permanent teeth, it was thought proper not to rely on any one method, but to perform reinforcing oral hygiene and promotion of remineralization in combination with therapeutic sealing which is stronger in short-term sealing effect. Although therapeutic sealing has been considered as the core in minimally invasive concept to treat the white spot lesions, its long-term clinical trials have not been suggested. Continuous research is strongly required for making this approach to acquire permanent nature, especially in regards of proper pretreatment and high molecular materials deeply penetrable into enamel.

  • PDF

Effect of attachments and palatal coverage of maxillary implant overdenture on stress distribution: a finite element analysis (상악 임플란트 피개의치에서 유지장치 종류와 구개 피개 유무에 따른 응력분포에 대한 유한요소분석)

  • Park, Jong-Hee;Wang, Yuan-Kun;Lee, Jeong-Jin;Park, Yeon-Hee;Seo, Jae-Min;Kim, Kyoung-A
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.70-79
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the effect of attachments and palatal coverage on stress distribution in maxillary implant overdenture using finite element analysis. Materials and Methods: Four maxillary overdenture 3-D models with four implants placed in the anterior region were fabricated with computer-aided design. 1) Ball-F: Non-splinted ball attachment and full palatal coverage, 2) Ball-P: Non-splinted ball attachment and U-shaped partial palatal coverage, 3) Bar-F: Splinted milled bar attachment and full palatal coverage, 4) Bar-P: Splinted milled bar attachment and U-shaped partial palatal coverage. Stress distribution analysis was performed with ANSYS workbench 14. 100 N vertical load was applied at the right first molar unilaterally and maximum stress was calculated at the implant, peri-implant bone and mucosa. Results: The use of the ball attachment showed lower maximum stress on implant and peri-implant bone than the use of the milled bar attachment. But it showed contrary tendency in the mucosa. Regardless of attachment, full palatal coverage showed lower maximum stress on implant, peri-implant bone and mucosa. Conclusion: Within the limitation of this study, ball attachment improved stress distribution on implant and peri-implant bone rather than milled bar attachment in maxillary implant overdenture. Also, full palatal coverage is more favorable in stress distribution.

Effects of Added Vegetable Oils on In vitro Formation of Fatty Acid Soaps and Fermentation Characteristics and NDF Disappearance Rate (식물성유 첨가가 In vitro 발효성상, NDF 소실율 및 지방산염 형성에 미치는 영향)

  • Kim, D.I.;Choi, J.R.;Lee, Y.H.;Lee, J.K.;Chung, T.Y.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.3
    • /
    • pp.355-372
    • /
    • 2004
  • In vitro experiments were conducted to determine the formation of fatty acid soaps (FAS) and neutral detergent fiber (NDF) disappearance rate. The substrates were a basal alfalfa hay containing 1) no oil, 2) 10% soybean oil, 3) 10% com oil, on a weight basis. All the substrates were incubated in triplicate for 0, 3, 6, 12, 24 and 48h in each experiment. After the incubation in the first experiment serum bottles (6oml) were analyzed for nonesterified, esterifed and fatty acid soaps contents. The serum bottles (120mI) from the second experiment were analyzed for pH, $NH_3-N$ and VFA concentration, and dry matter and NDF disappearance rate. pH decreased and the concentration of NH3-N increased significantly with longer incubation time (P<0.0001). The disappearance rates of dry matter and NDF significantly varied with feed, incubation time and oils (P<0.05). The molar concentration of total VFA increased and proportion of acetate significantly decreased with incubation time (P<0.0001), but the proportion of propionate significantly increased with longer incubation time (P<0.0001). Addition of oils to diet lowered the ratio of acetate:propionate (P<0.05). The esterified fatty acids (EFA) decreased with increasing incubation time (P<0.0001), and nonesterified fatty acids (NEFA) increased due to lipolysis of EFA, NEFA then reacted with cations to increase formation of FAS. The formation of FAS increased significantly at 48h of incubation time (P<0.0001). Especially, formation of stearic acid soaps was 27.5 and 32.5 folds with soybean oil and com oil supplements, respectively, by 48h of incubation time (P<0.0001). Alfalfa hay had higher cation contents, particularly Ca, which react with NEFA and FAS can be formed with longer incubation time. Saturated fatty acids had a higher proportion of FAS than did unsaturated fatty acids, suggesting that the former may react more extensively with cations. FAS contents increased with increasing chain length of the fatty acids. Since added vegetable oils fonned FAS, it might decrease negative effects on in vitro fermentation characteristics and NDF disappearance rate.