• Title/Summary/Keyword: First flushing

Search Result 60, Processing Time 0.029 seconds

Characteristics of Stormwater Runoff from Urban areas with Industrial Complex (산업단지의 도시 강우유출수 배출 특성)

  • Jung, Yong-Jun;Kim, Si-Won
    • Journal of Wetlands Research
    • /
    • v.14 no.1
    • /
    • pp.131-137
    • /
    • 2012
  • This study was investigated to characterize the stormwater runoff pollutant materials from the urban area mixed with industrial area. Almost the similar rainfall pattern is shown during the 5 years, and the yearly precipitation was 5.2~6.6 mm. The first flushing effect during the early-stage rainfall-run off was observed in some events. EMC ranges are 19.3~39.9 mg/L for BOD, 45.2~190 mg/L for CODcr, 67.2~351 mg/L for TSS, 3.6~10.3 mg/L for TN, 1.2~2.5 mg/L for TP. Heavy metal are not detected except Zn which is observed at only one event. The particle size was distributed to 10 ${\mu}m$ at the 3% weight volume and the 50% cumulative weight percent was shown at 12 ${\mu}m$.

Water Quality Characteristics and Influencing Factors of Park Drinking Fountains (공원 음수대의 수질 특성 및 영향인자 연구)

  • Sang-jo Kwon;Eun-ah Kim;Duk-hee Joh;Hyo-Jin Lee;Seung-gyu Jung;Seung-yeon Cho
    • Journal of Korean Society on Water Environment
    • /
    • v.40 no.5
    • /
    • pp.229-242
    • /
    • 2024
  • This study investigated water quality characteristics and influencing factors of park drinking fountains having directly piped water systems by analyzing stagnation water (first draw) and water after a 10-minute flush (flushed water). First draws exhibited significant variations in residual chlorine, heavy metals, bacteria, and turbidity, which were largely influenced by usage frequency and external environmental contamination. However, water quality stabilized after flushing. A seasonal analysis indicated that the greatest difference in residual chlorine between first draws and flushed water occurred in spring, followed by that in winter when drinking fountains were discontinued, accompanied by increased zinc concentrations in stagnation water. A comparative analysis of water quality variability by faucet type revealed that push-button faucets exhibited greater variabilities in copper, zinc, and nickel levels than screw-down faucets, likely due to corrosive by-products generated from water hammer effects. Additionally, an analysis based on exterior material indicated that metal fountains experienced higher temperature increases and elevated zinc concentrations in first draws than stone fountains. Regarding installation environments, drinking fountains exposed to direct sunlight or partial shade had higher concentrations of copper, zinc, and nickel in first draws than those installed in constant shade. Overall, these findings suggest that frequent use or flushing can help maintain stable water quality with the exception of push-button faucets.

A pediatric case of idiopathic Harlequin syndrome

  • Kim, Ju Young;Lee, Moon Souk;Kim, Seung Yeon;Kim, Hyun Jung;Lee, Soo Jin;You, Chur Woo;Kim, Jon Soo;Kang, Ju Hyung
    • Clinical and Experimental Pediatrics
    • /
    • v.59 no.sup1
    • /
    • pp.125-128
    • /
    • 2016
  • Harlequin syndrome, which is a rare disorder caused by dysfunction of the autonomic system, manifests as asymmetric facial flushing and sweating in response to heat, exercise, or emotional factors. The syndrome may be primary (idiopathic) with a benign course, or can occur secondary to structural abnormalities or iatrogenic factors. The precise mechanism underlying idiopathic harlequin syndrome remains unclear. Here, we describe a case of a 6-year-old boy who reported left hemifacial flushing and sweating after exercise. He had an unremarkable birth history and no significant medical history. Complete ophthalmological and neurological examinations were performed, and no other abnormalities were identified. Magnetic resonance imaging was performed to exclude lesions of the cerebrum and cervicothoracic spinal cord, and no abnormalities were noted. His final diagnosis was classic idiopathic harlequin syndrome. Herein, we report the first pediatric case of idiopathic harlequin syndrome in Korea.

Enhanced Aqueous Stability of Hirsutenone with Antioxidant

  • Moon, Ki-Young;Ahn, Byeong-Kil;Lee, Sang-Gon;Lee, Seo-Hyun;Yeom, Dong-Woo;Choi, Young-Wook
    • Journal of Pharmaceutical Investigation
    • /
    • v.41 no.6
    • /
    • pp.331-336
    • /
    • 2011
  • The instability of hirsutenone (HST), a potential therapeutic candidate for the treatment of atopic dermatitis (AD) and ovarian carcinoma, is one of the main concerns for the development of drug product. In the present study, aqueous stability of HST was investigated by kinetic analysis, and the effect of several factors covering temperature, nitrogen gas ($N_2$) flushing, and selection of proper antioxidant was compared. Cosolvent system composed of distilled water and methanol (9:1 v/v) was used as a vehicle to dissolve HST at the concentration of $200{\mu}g/mL$. Samples of aqueous solution were prepared under the absence or presence of antioxidants, such as ascorbic acid (AA), sodium edetate (EDTA), and ascorbyl palmitate (AP), and subjected for stability test. The degradation of HST in aqueous solution was followed by the first order kinetics with an extremely short half life of less than a week at room temperature, and was accelerated as the temperature increased. $N_2$ flushing brought a little enhancement in stability compared to control solution, but the effect was insufficient. The addition of AA and EDTA (0.1%) significantly enhanced the stability of HST at $40^{\circ}C$, but the addition of AP (0.01%) was limited due to its water insolubility and revealed no promising result. The stability of HST was increased proportionally by the amount of AA added, showing the difference in degree of stabilization as an order of magnitude. Finally, we conclude that HST was stabilized by the addition of a suitable antioxidant, suggesting AA as the most effective stabilizer.

Programmed Conditions of Supplying Carbon Dioxide to Keep its Desired Concentration in Kimchi Container (김치용기에서의 이산화탄소 농도 제어를 위한 주입 프로그램 조건 설정)

  • An, Duck Soon;Jo, Min Gyeong;Park, Su Yeon;Lee, Dong Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.25 no.2
    • /
    • pp.31-35
    • /
    • 2019
  • Kimchi is a refreshing sour food which gives sour and carbonic acid taste of carbon dioxide produced during the fermentation process. So, carbon dioxide injection was tried to raise carbonic acid taste of kimchi stored in the airtight container. First, carbon dioxide injection times of a given gas supply system were determined experimentally to attain initial concentration of 80% for different solid/liquid ratios. Since carbon dioxide is dissolved in kimchi to decrease its concentration during storage, periodical carbon dioxide injection conditions were needed and determined to keep the $CO_2$ concentration above 70%. For the initial flushing to 80% $CO_2$ concentration in model system filled with water, the injection time ranged from 40 to 89 seconds for free volumes of 2-8 L. $CO_2$ injection conditions for the under-ripened storage at $10^{\circ}C$ consisted of longer time at more frequent cycles for watery kimchi than for Chinese cabbage kimchi. At $0^{\circ}C$ of subsequent ripened stage storage of watery kimchi, the periodical injection at 3 hour interval was required because of continuous dissolution of carbon dioxide. However, Chinese cabbage kimchi did not require subsequent $CO_2$ injection during the ripened state storage and needed only flushing to 80% $CO_2$ at time of the container opening and closing. These results can be used as basic information for the programmed control of $CO_2$ injection in the kimchi container system.

Runoff Characteristics of Nonpoint Pollutants Source in Urban Area (중소도시지역 비점오염물질의 유출 특성)

  • Lee, Geon-Jik;Seong, Jin-Uk;Park, Ju-Hyun;Joe, Gyu-Soo;Park, Je-Chul
    • Journal of Environmental Science International
    • /
    • v.19 no.7
    • /
    • pp.819-827
    • /
    • 2010
  • This study was conducted to investigate runoff characteristics of non-point pollutants source at the urban area in boeun area, Chungbuk Province. The monitoring site covering the watershed of $2.11\;km^2$ contains about 40.3 % of total watershed with the urban area. The monitoring was conducted with six events for five months and Event Mean Concentration(EMC) and Site Mean Concentration(SMC) of SS, BOD, CODMn, T-N, T-P were calculated on the result of the water quality parameters. As a result of the comparion between Arithmetic Mean Concentration and Event Mean Concentration, it showed that over all Event Mean Concentration was higher than Arithmetic Mean Concentration. And it showed that SS, BOD, T-P featured the first-flushing effect, showing relatively high concentration in early-stage storm event.

Optimal Sizing of Intercepting Flow for Reducing Pollution Loads Caused by CSOs (CSOs 저감을 위한 차집관거 최적화 시스템)

  • Kong, Min-Keun;Bae, Ki-Hyun;Kang, Woo-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.4
    • /
    • pp.418-424
    • /
    • 2004
  • An abrupt high pollution loads in combined sewer systems is believed to be caused by first flushing actions and the resuspension of sediments deposited in sewers. Therefore, pollution loads in each flow regulator have a different tendency. This systems control intercepting flow in each flow regulator using water quality and water level. A desired quantity of intercepting flow was adjusted and the necessary slide position for a constant intercepting is calculated by Optimization programming. This systems make it possible to reduce pollution loads caused by CSOs to water body, may be alternative for the stable operation of STP through improving water quality to STP.

Risk Assessment of Indoor Pollution by BTEX Released from Groundwater (지하수내 BTEX에 의한 실내오염시 위해도 평가)

  • 유동한;이한수;김상준;양지원
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.5
    • /
    • pp.373-381
    • /
    • 2002
  • Benzene, Ethyl-benzene, Toluene and Xylene (BTEX) can be released to a groundwater in case of the oil leakage from underground storage tank of a gas station. These chemicals are found to contribute to the total inhalation risk from contaminated indoor air. This study presents the assessment of a human exposure to such chemicals released from the groundwater into indoor air. At first, a 2-compartment model is developed to describe the transfer and distribution of the chemicals released from groundwater in a house through showering, washing clothes, and flushing toilets. The model is used to estimate a daily human exposure through inhalation of such BTEX for adults based on two sets of exposure scenarios. Finally, a sensitivity analysis is used to identify important parameters. The results obtained from the study would help to increase the understanding of risk assessment issues associated with the indoor pollution by BTEX released from contaminated groundwater.

Assessment of Human Exposures to Indoor Radon Released from Groundwater (지하수로부터의 실내 라돈오염시 인체노출평가)

  • 유동한;김상준;양지원
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.3
    • /
    • pp.241-249
    • /
    • 2001
  • A report by the National Research Council in the United States suggested that many lung cancer deaths each year are associated with breathing radon in indoor air. Most of the indoor radon comes directly from soil beneath the basement of foundation. Recently, radon released from groundwater is found to contribute to the total inhalation risk from indoor air. This study presents the assessment of a exposure to radon released from the groundwater into indoor air. At first, a 3-compartment model is describe the transfer and distribution if radon released from groundwater in a house through showering, washing clothes, and flushing toilets. The model is used to estimate a daily human exposure through inhalation of such radon for adults based on two sets of exposure scenarios, Finally, a sensitivity analysis is used to identify important parameters. The results obtained from the study would help to increase the understanding of risk assessment issues associated with the indoor radon released from groundwater.

  • PDF

Ovarian Follicular Populations Prior to and during Superovulation in Cattle: Relationship with Superovulatory Response

  • Manik, R.S.;Singla, S.K.;Palta, P.;Madan, M.L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.11 no.5
    • /
    • pp.486-490
    • /
    • 1998
  • The present study examined the follicular populations prior to and during superovulation and investigated their relationship with superovulatory response in crossbred cattle. Eleven animals were administered i.m. 8 doses of Folltropin of 2.5 ml each (1.75 mg/ml) spread over 4 days beginning on Day 10 of oestrous cycle, and 30 and 20 mg Lutalyse was given alongwith the 5th and 6th injections of Folltropin, respectively, to induce luteolysis. The animals were artificially inseminated 48, 60 and 72 h after the first Lutalyse injection. The number of corpora lutea (CL) was recorded by palpation per rectum and embryos were recovered non-surgically on Day 6 (Day 0 day of superoestrus). The ovarian follicular population was examined by transrectal Ultrasonography 15 h prior to and 52 h after the first FSH injection, and then on the day of superoestrus and the day of flushing. The follicles were classfied on the basis of diameter as small (3-5 mm), medium (6-9 mm) and large (${\geq}10mm$). The total number of follicles increased significantly (p < 0.01) from $2.45{\pm}0.35$, 15 h prior to the first FSH injection to $8.09{\pm}1.12$, 52 h after the first FSH injection and then further to $13.27{\pm}1.89 $ on the day of superoestrus. A positive correlation was observed between the number of small follicles 15 h prior to the first FSH injection (r = 0.60, p < 0.05), the number of large follicles 52 h after the first FSH injection (r=0.59, p < 0.05) and the number of CL. The follicular population prior to and during superovulation was, however, not significantly different between high (> 6 CL) and low responders (${\leq}6CL$). The present study suggests that the follicular populations undergo dynamic changes during superovulation and that follicular populations prior to superovulation have a limited application as an indicator of the superovulatory response.