• Title/Summary/Keyword: First flush criteria

Search Result 17, Processing Time 0.021 seconds

Characteristics of First Flush in Highway Storm Runoff (강우시 발생하는 고속도로 유출수의 초기우수 특성 및 기준)

  • Kim, Lee-Hyung;Kang, Joohyon
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.641-646
    • /
    • 2004
  • Vehicle emissions from highway landuse include different pollutants such as heavy metals, oil and grease and particulates from fuels, brake pad wear and tire wear. Since highways are impervious and have high pollutant mass emissions from vehicular activity, it is considered as stormwater intensive landuses. Therefore this research was performed to understand the magnitude of first flush and to suggest the criteria of first flush for storm runoff management in highways. The fractions of washed-off mass are very high in first 30% of runoff volume, which suggests a definition of first flush. The washed-off mass stabilizes after 30% of the runoff volume and it is apparent that treatment capacity in the early part of a storm is more valuable than treatment capacity in the later part of the storm. Using the criteria of "high" first flush and "medium" first flush, as 50% of the mass in the first 30% of the volume, and 30 to 50% in the first 30% volume, respectively, more than 30% of the storms showed high first flush. A "first flush friendly" best management practice(BMP), meaning a BMP that can treat a high percentage or all of the initial flow, would be advantageous up to 80% of the events.

Runoff Characteristics of NPS in Agricultural Area (포도재배지의 비점오염물질 유출특성)

  • Yi, Youn-Jeong;Lee, Jae-Woon;Kwon, Hun-Gak;Yoon, Young-Sam;Lee, Jae-Kwan
    • Journal of Environmental Science International
    • /
    • v.20 no.10
    • /
    • pp.1285-1295
    • /
    • 2011
  • In this study, occurrence status of nonpoint pollutants and characteristics of discharge by each nonpoint pollutants were examined through monitoring on nonpoint pollutants caused when raining in vineyard belonging to the agricultural area of various land use patterns. Also, the first flush analysis limited to studies on the existing non-percolation area was applied to percolation area to ascertain availability and criteria of study. Various water quality and sluice of nonpoint pollutants were analyzed, based on which discharge of nonpoint pollutants in agricultural area was ascertained to be influenced greatly by artificial factors such as period, cultivation, management, etc. Meanwhile, the first flush phenomenon at agricultural area was ascertained to occur, and the first flush was quantified through calculation of the first flush ratio. If MFF30 is based, discharge load by each nonpoint pollutants caused when raining was investigated to include 40.8% on the basis of total discharge. In case of SS in pollutants showed the highest first flush phenomenon of 64.8%. Through such a result, calculation possibility of the initial rain criteria was ascertained, and it was determined that reliability-assured criteria were calculated through further monitoring.

Determination of First Flush Criteria in Highway Stormwater Runoff using Dynamic EMCs (동적 EMC를 이용한 고속도로 초기우수 처리 기준 산정)

  • Kim, Lee-Hyung;Lee, Eun-Ju;Ko, Seok-Oh;Kim, Sung-Gil;Lee, Byung-Sik;Lee, Joo-Kwang;Kang, Hee-Man
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.294-299
    • /
    • 2006
  • The Ministry of Environment in Korea has introduced Total Pollution Load Management System (TPLMS) in major 4 large rivers to protect the water quality from possible pollutants. In order to successfully achieve the TPLMS, the nonpoint source should be controled by applying the best management practices in highly polluted areas. Of the various nonpoint sources, the highways are stormwater intensive landuses because of its high imperviousness and high pollutant mass emissions. The EMC (Event Mean Concentration) is an important parameter to correctly determine the pollutant mass loadings from nonpoint sources. However, it has wide ranges because of various reasons such as first flush phenomenon, rainfall and watershed characteristics. Even though the EMC is closely related to the first flush phenomenon, the relationship have not proven until present. Therefore, in this paper, the dynamic EMC method will be introduced to clearly make the relationship between EMC and first flush phenomenon. Also by applying the dynamic EMC method to monitored data, we found that the highly concentrated stormwater runoff was washed off within 20~50 minutes storm duration. The first flush criteria for economical treatment was also determined to 5~10 mm (mean=7.4 mm) as a cumulative rainfall.

The Estimation of Pollution Loads in First-flush Overflows with Various Rainfall and Regional Characteristics (강우 및 지역특성별 초기우수월류에 의한 오염부하 기여도 평가)

  • Kim, Hongtae;Shin, Dongseok;Kim, Yongseok
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.6
    • /
    • pp.622-631
    • /
    • 2014
  • The purpose of this research was to find a proper disposal rainfall extent to improve water quality. SWMM was applied to select catchment area and tested first flush load and rainfall extent. BOD 40mg/L was selected to dispose the first flush and sewer overflow with the same as the criteria of Sewerage Act. Design rainfall, BOD load ratio of first flush sewer overflow, and the ratio of disposal flow were analyzed under various rainfall distribution. BOD load and design rainfall to treat overflow in situation of first flush extent with 4.3~17.4% were 56~87% and 3.8~6.8 mm/day, respectively. In urban area, first flush loads were not correspond to land activities, but tend to increase with increasing rainfall amount and drainage area. The more the distribution of rainfall is similar to Huff-frontal or central distribution of rainfall, the more increase the first flush loads.

Runoff Characteristics of Stormwater in Small City Urban Area (국내 중소 도시지역 강우유출수의 유출특성)

  • Lee, Hong-Shin;Lee, Seung-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.3
    • /
    • pp.193-202
    • /
    • 2009
  • This study was conducted to identify the magnitude of first flush in small city urban area and to provide the basic information on the criteria of stormwater runoff management. Monitoring site was surrounded by residential area in Gumi city near to national industrial complex and the monitoring period was three months. Total watershed area was 24.9 ha, where 80% of the area is impervious (asphalt of pavement type). Periodic monitoring of conventional water quality parameters were conducted with six times of rainfall period. Event mean and site mean concentrations for all the parameters were calculated based on the analytical results. Particle size distribution was 9.82 ${\mu}m$ for $D_{0.1}$, 38.99 ${\mu}m$ for $D_{0.5}$ and 159.61 ${\mu}m$ for $D_{0.9}$ respectively. First flush phenomenon was detected highly in particulate solids than dissolved ones. The first flush criteria results by mass first flush contained between 44.4% to 58.5% pollutant mass during the first 30% of runoff volume. Mass first flush ratio and particle size distribution obtained in this study are expected to provide the basic information for the design and operation of non-point source treatment facility.

Characteristics of stormwater runoff from urbanized areas (도시화된 토지이용에서 유출되는 강우유출수의 유출특성분석)

  • Mercado, Jean Margaret R.;Geronimo, Franz Kevin F.;Choi, Jiyeon;Song, Young-Sun;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.14 no.2
    • /
    • pp.159-168
    • /
    • 2012
  • Stormwater runoff affects the quality of surface water and groundwater due to the nonpoint sources (NPSs) of pollutants that it carries during storm events. Typically, urbanized areas experience high pollutant mass emission because of paved roads and other areas which are all highly impervious. For this reason, proper identification of the levels of pollutants from the watershed area is important to pass the Ministry of Environment of the Republic of Korea's water quality standards in rivers and streams. This research was conducted in order to determine and quantify the different constituents present in stormwater runoff generated from highly impervious areas in Cheonan City, Korea. Also, the average event mean concentration (EMC) of stormwater runoff from paved areas was compared with EMCs of other countries to determine the possible causes of its occurrence. In addition, the occurrence of first flush phenomenon was studied in order to find the first flush criteria to be used on the design of best management practices. The results show the pollutant concentration of stormwater runoff was higher than other countries due its landuse and relatively small size of catchment area. During the first 30 minutes of the rainfall events, occurrence of first flush phenomenon was highly evident. Several factors affected the pollutant concentrations in the stormwater such as landuse type, geographic and topographic characteristics,catchment area and amount of rainfall. This research can provide guidance in achieving an effective NPS pollution management applicable to highly urbanized areas in the future.

Dynamic EMCs and Optimum Treatment Criteria for Stormwater Runoff of a Railway Station (철로 역사 건설에 따른 강우 유출수내 비점오염물질의 동적 EMCs 및 처리방안 연구)

  • Lim Kyeong-Ho;Kim Kee-Dong;Lee Byung-Sik;Kim Lee-Hyung
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.4
    • /
    • pp.308-313
    • /
    • 2005
  • In order to successfully propel the stormwater management program, administration plan of stormwater management is enacted in Spring, 2005. Hereafter, in a newly developing area such as a railway station, the best management practices should be established to control the nonpoint pollutant. Construction of a railway station means the increasing of imperviousness rate and lots of nonpoint pollutant emissions during rainfall. Therefore this research was performed to determine the pollutant EMC and to suggest the possible best management practice for treating nonpoint pollutants from a railway station. The $95\%$ confidence intervals of pollutant EMC were ranged to 69.4-115.2mg/L for TSS, 132.7-190.4mg/L for COD, 5.4-15.1ug/L for Oil & Grease, 4.9-12.4mg/L for TKN and 568.4-620.1ug/L for TP. The first flush criteria was ranged to 5-10mm accumulated rainfall using dynamic EMCs, Also laboratory reactor testing was performed. It shows that Zeolite media is useful for removing the washed-off pollutants from a railway station, especially for metal ions.

Characteristics of Washed-off Pollutants and Dynamic EMCs in a Parking Lot and a Bridge during Storms (주차장 및 교량지역의 강우유출수내 비점오염물질의 특성 비교 및 동적 EMCs)

  • Kim, Lee-Hyung;Lee, Seonha
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.3
    • /
    • pp.248-255
    • /
    • 2005
  • Since the water quality of drinking water sources has been recognized as a big issue, the ministry of Environment in Korea is designing the total maximum daily load (TMDL) program for 4 major large rivers. The TMDL program can be successfully performed as controling the nonpoint pollutants from watershed area near the river. Of the various landuses in nonpoint pollution, parking lots and bridges are stormwater intensive landuses because of high imperviousness and high pollutant mass emissions from vehicular activities. Vehicle emissions from those areas include different pollutants such as heavy metals, oil and grease and particulates from sources such as fuels, brake pad and tire wear, etc. Especially the pollutant washed-off from the landuses are directly affecting to the river water quality. Therefore this research was conducted to understand the magnitude and nature of the stormwater emissions with the goal of quantifying stormwater pollutant concentrations and mass emission rates of pollutants from parking lot and bridges in Korea. In Kongju city areas, two monitoring sites were equipped with an automatic rainfall gages and an automatic flow meter for accumulating the useful data such as rainfall, water quality and runoff flow. This manuscripts will show the concentration changes during storm duration and EMCs to characterize the concentration profiles in different land uses. Also the first flush criteria will be suggested using dynamic EMCs. The definition of dynamic EMC is a new approach explaining the relationship of EMC and first flush effect.

Characteristics and Control of Nonpoint Pollutants in Railway Station (철로 역사에서 발생 가능한 비점오염물질의 특성 및 관리방안)

  • Oa Seong Wook;Kim Lee-Hyung
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1695-1700
    • /
    • 2004
  • Nonpoint pollutants were monitored on railway station land use. Lots of pollutant mass were washed-off in a first hour. The 95$\%$ confidence interval of pollutant concentrations ranges from 61.6 to 115.4 mg/L for TSS(mean= 88.50 mg/L). 103.8$\∼$244.1 mg/L for COD(mean= 174 mg/L) and 7.68$\∼$17.32 mg/L for Oil & Grease(mean= 12.5 mg/L). The various metals were also washed-off during storm runoff from railway station. The ranges of 95$\%$ confidence intervals were 39.2$\∼$84.0 ug/L for total Cu(mean= 61.6 ug/L), 14.0 $\∼$ 25.8 ug/L for total Pb(mean= 19.9 ug/L) and 182.2 $\∼$ 376.1 ug/L for total Zn(mean= 279.2 ug/L). As a result of this research, we concluded that up to 50$\%$ of the total pollutant mass can be removed when first 30$\%$ of the total flow are treating, and it can be a first flush criteria for best management practices.

  • PDF