• 제목/요약/키워드: Firing angle

검색결과 112건 처리시간 0.028초

Initial Firing Angle Control of Parallel Multi-Pulse Thyristor Dual Converter for Urban Railway Power Substations

  • Kim, Sung-An;Han, Sung-Wo;Cho, Yun-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.674-682
    • /
    • 2017
  • This paper presents an optimal initial firing angle control based on the energy consumption and regenerative energy of a parallel multi-pulse thyristor dual converter for urban railway power substations. To prevent short circuiting the thyristor dual converter, a hysteresis band for maintaining a zero-current discontinuous section (ZCDS) is essential during mode changes. During conversion from the ZCDS to forward or reverse mode, the DC trolley voltage can be stabilized by selecting the optimal initial firing angle without an overshoot and slow response. However, the optimal initial firing angle is different depending on the line impedance of each converter. Therefore, the control algorithm for tracking the optimal initial firing angle is proposed to eliminate the overshoot and slow response of DC trolley voltage. Simulations and experiments show that the proposed algorithm yields the fastest DC voltage control performance in the transient state by tracking the optimal firing angle.

위상제어 정류기의 예측전류제어를 위한 새로운 고정밀 게이팅 알고리즘 (High precision Gating Algorithm for Predictive Current Control of Phase Controlled Rectifier)

  • 정세종;송승호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권3호
    • /
    • pp.206-211
    • /
    • 2004
  • In phase controlled rectifier, it's been known that a fast response is achieved by predictive current control without any overshoot. The frequent sampling period is essential to improve the firing accuracy in conventional predict current control. However, improving the firing accuracy if difficult to reduce the period of sampling efficiently because current sampling and predictive current control is carried out in every period and the ON-OFF current control is performed by comparing two different one. To improve the firing accuracy at the predictive current control, the calculated firing angle is loaded into the high-accuracy hardware timer. So the calculation of exact crossing point between the predictive and actual current is the most important. In this paper, the flow chart for proposed firing angle calculation algorithm is obtained for the fastest current control performance in transient state. The performance of proposed algorithm is verified through simulations and experiments.

유도발전기 계통 연계시 돌입전류 저감을 위한 소프트 스타터 점호각 제어 (Firing Angle Control of Soft Starter for Reduction of Inrush Current during Induction Generator to Gird)

  • 권태화;송승호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.230-233
    • /
    • 2003
  • Simulation model of induction type fixed speed wind power generator is developed. It is shown that the peak value of inrush current during start up changes according to the firing angle control strategy of soft starter. New proposed firing angle control scheme showed $25\%$ of reduction of peak current which results in smaller drop of gird voltage at the point of common coupling during start up.

  • PDF

데이터 병렬루프를 가지는 사이리스터 컨버터의 PID 점호각 제어 (Firing Angle Control of Thyristor Converter using PID Controller with Parallel Data Loop)

  • 이재성;장진석;추영배;이동희
    • 전력전자학회논문지
    • /
    • 제14권4호
    • /
    • pp.278-284
    • /
    • 2009
  • 본 논문에서는 직류 전력을 공급하기 위한 사이리스터 컨버터의 출력 응답특성을 개선하기 위해 데이터 병렬 루프를 가지는 PID 제어 방식을 제안한다. 제안된 방식에서 사이리스터 컨버터의 점호각은 부하전류와 지령전압에 따라 결정된 점호각을 제어기와 병렬로 연결된 데이터 루프에서 발생하고, 이 점호각에 의해 발생하는 출력전압의 오차를 PID 제어기에서 보상하여 제어하는 방식이다. 제안된 방식의 실제적인 적용에서, 부하전류에 의해 병렬 데이터 루프의 점호각이 급격하게 변동하는 것을 억제하기 위해 간단한 디지털 저역통과 필터를 통하여 부하전류와 지령전압의 크기에 따라 룩-업 테이블 방식의 점호각이 결정되도록 설계하였다. 제안된 방식은 50[A]급의 사이리스터컨버터 실험을 통하여 검증하였다.

점호각을 고려한 유도전동기의 소프트 기동 특성 해석 (Analysis of Soft Start-up Characteristics of the Induction Motor Considering the Firing Angle)

  • 김종겸;박영진
    • 전기학회논문지
    • /
    • 제65권6호
    • /
    • pp.1007-1012
    • /
    • 2016
  • Induction motors are used widely in driving load of a fluid, such as a pump or a fan in the industry. Induction motor has been generated the voltage drop by the occurrence of a high current during startup. In addition, high start-up current can act as a mechanical stress on the shaft of the motor. So there is need a way to reduce the starting current. Soft start method is one of the many ways to reduce the starting current. This method uses silicon-controlled rectifiers(SCRs) for varying value of the voltage applied to the motor. There is a case for fixing or changing the thyristor firing angle to adjust the magnitude of the voltage. Starting power factor of induction motor is very low compared to the normal operation. Soft starting with the firing angle fixed needs to be considered a low power factor at startup. In this study, we compared the direct start characteristics and soft start characteristics considering the low power factor at the time of start-up. It was possible to confirm that the starting current and the voltage drop is present differently according to the firing angle.

A Study on the Adjusting Output Energy of the $CO_2$ Laser Controlled Directly in AC Power Line

  • Noh, Ki-Kyong;Jeong, Jong-Jin;Chung, Hyun-Ju;Kim, Hee-Je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권4호
    • /
    • pp.152-154
    • /
    • 2005
  • We demonstrate a simple $CO_2$ laser by controlling firing angle of a TRIAC switch in ac power line. The power supply for our laser system switches the voltage of the AC power line (60Hz) directly. The power supply does not need elements such as a rectifier bridge, energy-storage capacitors, or a current-limiting resistor in the discharge circuit. In order to control the laser output power, the pulse repetition rate is adjusted up to 60Hz and the firing angle of TRIAC gate is varied from $45^{circ}$ to $135^{circ}$. A ZCS(Zero Crossing Switch) circuit and a PIC one-chip microprocessor are used to control the gate signal of the TRIAC precisely. The maximum laser output of 40W is obtained at a total pressure of 18 Torr, a pulse repetition rate of 60Hz, and a TRAIC gate firing angle of $90^{circ}$.

Mathematical Models for Hit Probabilities using Small-arms against Fast Low Flying Aircraft

  • Park, Chan-Tae
    • 한국국방경영분석학회지
    • /
    • 제7권1호
    • /
    • pp.81-117
    • /
    • 1981
  • Mathematical models for hit probabilities of small arms are developed in order to estimate the expected hits on an aircraft for certain altitudes and air speeds. A model for the firing lead angle is developed for cases when the distribution of hits is normal and the firing angle is from 20 degrees to 160 degrees. probabilities of hit for single and multiple shots at various altitudes are calculated. Tables are given showing the probability of hits and kill for targets flying at high speed above 500 feet from ground level.

  • PDF

파이어링 상태의 일정 축 각속도에서 엔진 베어링의 마모 해석 - Part I: 베어링 마모발생 부위 파악 (Wear Analysis of Engine Bearings at Constant Shaft Angular Speed on a Firing State - Part I: Understanding of Bearing Wear Region)

  • 전상명
    • Tribology and Lubricants
    • /
    • 제34권3호
    • /
    • pp.93-107
    • /
    • 2018
  • The purpose of Part I of this study is to find the potential region of wear scarring on engine journal bearings operating at a constant angular crank shaft velocity under firing conditions. To do this, we calculate the applied loads and eccentricities of a big-end journal bearing installed on a four-stroke and four-cylinder engine at every crank angle. Then, we find potential wear regions, such as a minimum oil film thickness, at every crank angle below most oil film thickness scarring wear (MOFTSW) obtained based on the concept of the centerline average surface roughness. Thus, the wear region is defined as a set of each film thickness below the MOFTSW at every crank angle. In this region, the wear volume changes according to the wear depth and wear angle, depending on the minimum oil film thickness at every crank angle. The total wear volume is the summation during one cycle. Graphical views of the region in the two-dimensional coordinates show the crank angle and bearing angle along the journal center path, indicating the position of the minimum oil film thickness. The results of wear analysis show that the possible wear region is located at a few tens of angles behind the upper center of a big-end bearing at maximum power rpm.

Novel Third Harmonic Current Injection Technique for Harmonic Reduction of Controlled Converters

  • Eltamaly, Ali M.
    • Journal of Power Electronics
    • /
    • 제12권6호
    • /
    • pp.925-934
    • /
    • 2012
  • Three-phase controlled converters have many applications in the utility interfacing of renewable energy sources and adjustable speed drives as a rectifier or inverter. The utility line currents of these converters have a high harmonic distortion, which is more than the harmonic standards. This paper introduces a new technique for circulating the third harmonic currents from the dc-link to the line currents to reduce their harmonic contents. The proposed system uses a single-phase PWM converter to control the angle and amplitude of the injection current for each of the firing angle of a three-phase converter. A detailed analysis is introduced to achieve a relationship between the firing angle of the three-phase controlled converter and the power angle of the PWM converter. In addition, a detailed design for the other injection path components is introduced. A simulation and experimental work is introduced to prove the mathematical derivations. Analysis, simulation and experimental results prove the superiority of the proposed technique.