• 제목/요약/키워드: Firing Position

검색결과 56건 처리시간 0.021초

파이어링 상태의 일정 축 각속도에서 엔진 베어링의 마모 해석 - Part I: 베어링 마모발생 부위 파악 (Wear Analysis of Engine Bearings at Constant Shaft Angular Speed on a Firing State - Part I: Understanding of Bearing Wear Region)

  • 전상명
    • Tribology and Lubricants
    • /
    • 제34권3호
    • /
    • pp.93-107
    • /
    • 2018
  • The purpose of Part I of this study is to find the potential region of wear scarring on engine journal bearings operating at a constant angular crank shaft velocity under firing conditions. To do this, we calculate the applied loads and eccentricities of a big-end journal bearing installed on a four-stroke and four-cylinder engine at every crank angle. Then, we find potential wear regions, such as a minimum oil film thickness, at every crank angle below most oil film thickness scarring wear (MOFTSW) obtained based on the concept of the centerline average surface roughness. Thus, the wear region is defined as a set of each film thickness below the MOFTSW at every crank angle. In this region, the wear volume changes according to the wear depth and wear angle, depending on the minimum oil film thickness at every crank angle. The total wear volume is the summation during one cycle. Graphical views of the region in the two-dimensional coordinates show the crank angle and bearing angle along the journal center path, indicating the position of the minimum oil film thickness. The results of wear analysis show that the possible wear region is located at a few tens of angles behind the upper center of a big-end bearing at maximum power rpm.

한국인의 인체 특성을 고려한 사격시 충격특성 해석 (A Study on Impact Analysis of the Korean Anthropometric Characteristic on Shooting)

  • 이장원;이영신;최영진;채제욱;최의중
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.150-153
    • /
    • 2005
  • The rifle impact of human body is affected by geometry of human for rifling. The interaction of human-rifle system influence a firing accuracy. In this paper, impact analysis of human model for standing postures with two B.C. carried out. ADAMS code and LifeMOD is used in impact analysis of human model and modeling of the human body, respectively. On the shooting, human model is affected by rifle impact during the 0.001 second. Also, Because Human Natural frequency is 5-200Hz, human impact is considered during 0.2-0.005 sec. Dut to the Firng test, Performed simulation time for shooting is 0.1 second. Applied constraint condition to human-rifle system is rotating and spherical condition. Also, The resulrt of changin the position of the grip is dfferent from the each other. As the results, The human model of firing was built successfully.

  • PDF

폐쇄공간 화재 발생시 온도 및 연소산화물의 분포에 관한 모델 해석 (A Numerical Analysis of the Distribution of Temperature and Combustio Products I case of Compartment Fire)

  • 차형석;이희근
    • 터널과지하공간
    • /
    • 제8권1호
    • /
    • pp.8-16
    • /
    • 1998
  • The first purpose of this study is to verify the application of computer modelling to a enclosed space fire. The second one is to determine temperature distribution for the three different ventilation types in case of a enclosed space fire. The third one is to find out the ventilation direction and ventilation quantity to remove effectively heat and combustion products generated by a fire in variable air volume(VAV) system. Firstly, compared with experimental results of Lawrence Livermore National Laboratory(LLNL), numerical results show good agreements. Secondly, among three different ventilation types, the numerical analyses show the highest temperature distribution in occupied zone(up to 1.8 m from bottom) from firing moment to 100 sec. when supply ducts are placed in ceiling and extract duct is placed close to the bottom on side walls. This is due to disadvantageous position of extract duct in ventilating high temperature air which rise because of buoyancy force. Thirdly, this study finds out effective ventilation direction and ventilation quantity to remove heat and combustion products generated by a fire by using VAV system. $CO_2$ concentration is used as a fire fume removal index. As soon as a fire happens, ventilation direction is changed in order to gather and drive out fire fumes. In case of three times ventilation quantity of ordinary one, $CO_2$ concentration and temperature have begun to decrease at 120 sec. after firing, i.e.fire fumes have begun to be removed.

  • PDF

120미리 박격포용 고체 로켓추진제 연구 (Study on Solid Rocket Propellants for 120mm Mortar)

  • 조준현;권태수;정덕진;임유진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.173-176
    • /
    • 2009
  • 박격포는 근거리 진지전이나 직사화기 곡사화기로는 사격할 수 없는 배사면의 적을 큰 낙각의 탄도를 그리는 포탄으로 공격할 수 있으므로 보병부대에서 효율적으로 운용되고 있다. 육군에서는 정확성, 기동성 및 사거리가 증대된 120미리 박격포의 도입 필요성을 제기하고 있으며, 관련 연구도 꾸준히 진행되고 있다. 본 연구에서는 120미리 박격포탄 중 사거리연장탄에 사용되는 로켓추진제의 조성을 설계하여 시제품을 제조한 후 지상연소시험과 발사시험을 통해 120미리 박격포용 사거리연장탄의 개발 가능성을 알아보았다.

  • PDF

액체로켓엔진 재생냉각 연소기의 점화 특성 연구 (A Study on the Ignition Characteristics of Liquid Rocket Engine Thrust Chamber with Regenerative Cooling)

  • 이광진;한영민;김종규;최환석
    • 한국추진공학회지
    • /
    • 제16권6호
    • /
    • pp.73-78
    • /
    • 2012
  • 국내 기술로 개발된 액체로켓엔진 연소기의 점화 특성을 연소시험을 통해 분석하였다. 연소시험에 사용된 연소기들은 점화제용 분사기, 막냉각 방식 그리고 산화제 입구 위치가 다른 특징을 지니며 각기 다른 시동 시퀀스를 적용하였다. 분석결과 산화제 매니폴드의 온도 프로파일에 따라 저주파 섭동이 점화구간 내에서 나타남을 보였다. 이 저주파 섭동은 연소기의 기능장애를 유발하지는 않았지만, 엔진 시스템 및 발사체와의 인터페이스측면에서 지속적인 관심 요소로서 관찰이 요구된다.

웨이브렛 필터를 이용한 복합 중첩 근신호의 최적화 분리 알고리즘 (An Algorithm for the Optimum Separation of Superimposed EMG Signal Using Wavelet Filter)

  • 이영석;김성환
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권3호
    • /
    • pp.319-326
    • /
    • 1996
  • Clinical myography(EMG) is a technique for diagnosing neuromuscular disorders by analyzing the electrical signal that can be records by needle electrode during a muscular contraction. The EMG signal arises from electrical discharges that accompany the generation of force by groups of muscular fiber, and the analysis of EMG signal provides symptoms that can distinguish disorder of mLecle from disor- ders of nerve. One of the methods for analysis of EMG signal is to separate the individual discharge-the motor unit action potentials(MVAPS) - from EMG signal. But we can only observe the EMG signal that is a superimposed version of time delayed MUAPS. To obtain the information about MUAP(, i.e., position, firing number, magnitude etc), first of all, a method that can separate each MUAP from the EMG signal must be developed Although the methods for MUAP separation have been proposed by many researcherl they have required heavy computational burden. In this paper, we proposed a new method that has less computational burden and performs more reliable separation of superimposed EMG signal using wavelet filter which has multiresolution analysis as major property. As a result, we develope the separation algorithm of superimposed EMG signal which has less computational burden than any other researchers and exacutes exact separation process. The performance of this method has been discussed in the automatic resolving procedure which is neccessary to identify every firing of every motor unit from the EMG pattern.

  • PDF

고관절 신전시 요통환자와 정상인의 슬괵극, 대둔근, 요추기립근의 근 수축 개시시간 비교 (The Comparison of the Onset Time of Hamstring, Gluteus Maximus, and Lumbar Erector Spinae Muscle Activity During Hip Extension Between Subjects With Low Back Pain and Healthy Subjects)

  • 권오윤;고은경
    • 한국전문물리치료학회지
    • /
    • 제9권2호
    • /
    • pp.33-42
    • /
    • 2002
  • The purpose of this study was to compare the onset times of muscle activities and the order of muscle firing in hamstring gluteus maximus, and lumbar erector spinae muscle during active hip extension between subjects with low back pain (LBP) and healthy subjects. Thirty subjects, 15 with LBP and 15 healthy subjects, participated in this study. Electromyographic activity was recorded during active hip extension in prone and standing position. Relative onset times of these muscle activities were determined. Similar muscle firing order in hamstring, gluteus maximus, and lumbar erector spinae muscle showed in both groups and positions. However, the onset time of gluteus maximus was significantly later in prone and standing active hip extension in subjects with LBP than in healthy subjects. The onset time of lumber erector spinae muscle activity was significantly delayed in subjects with LBP in standing active hip extension, The delayed onset times of gluteus maximus and lumbar erector spinae muscles' activities were probably related to LBP. Further studies are needed to identify whether the delayed onset times of gluteus maximus and lumbar erector spinae muscle activities are the contributing factors to LBP.

  • PDF

연식주퇴 시스템의 전방운동량에 관한 연구 (A Study on the Forward Momentum of a Soft Recoil System)

  • 박선영;배재성;황재혁;강국정;안상태
    • 한국군사과학기술학회지
    • /
    • 제13권6호
    • /
    • pp.976-981
    • /
    • 2010
  • A soft-recoil or FOOB (Fire-Out-Of-Battery) system can reduce the recoil force considerably. Its firing sequency is different from that of a conventional or FIB (Fire-In-Battery) system. In FOOB system, the gun is latched and preloaded in its battery position prior to firing. When unlatched, the gun is accelerated to the forward direction and then the forward momentum of the recoil part is generated. Since this momentum reduces the recoil impulse, the recoil force will decrease significantly. When designing the soft-recoil system it is important to design the forward momentum profile of a recoiling part. In the present study, the method to determine the forward momentum has been studied and its optimum value has been obtained theoretically. The numerical simulation of the soft-recoil system is performed to show that the present soft-recoil system works functionally well.

Safe Sedation and Hypnosis using Dexmedetomidine for Minimally Invasive Spine Surgery in a Prone Position

  • Kim, Kyung Hoon
    • The Korean Journal of Pain
    • /
    • 제27권4호
    • /
    • pp.313-320
    • /
    • 2014
  • Dexmedetomidine, an imidazoline compound, is a highly selective ${\alpha}_2$-adrenoceptor agonist with sympatholytic, sedative, amnestic, and analgesic properties. In order to minimize the patients' pain and anxiety during minimally invasive spine surgery (MISS) when compared to conventional surgery under general anesthesia, an adequate conscious sedation (CS) or monitored anesthetic care (MAC) should be provided. Commonly used intravenous sedatives and hypnotics, such as midazolam and propofol, are not suitable for operations in a prone position due to undesired respiratory depression. Dexmedetomidine converges on an endogenous non-rapid eye movement (NREM) sleep-promoting pathway to exert its sedative effects. The great merit of dexmedetomidine for CS or MAC is the ability of the operator to recognize nerve damage during percutaneous endoscopic lumbar discectomy, a representative MISS. However, there are 2 shortcomings for dexmedetomidine in MISS: hypotension/bradycardia and delayed emergence. Its hypotension/bradycardiac effects can be prevented by ketamine intraoperatively. Using atipamezole (an ${\alpha}_2$-adrenoceptor antagonist) might allow doctors to control the rate of recovery from procedural sedation in the future. MAC, with other analgesics such as ketorolac and opioids, creates ideal conditions for MISS. In conclusion, dexmedetomidine provides a favorable surgical condition in patients receiving MISS in a prone position due to its unique properties of conscious sedation followed by unconscious hypnosis with analgesia. However, no respiratory depression occurs based on the dexmedetomidine-related endogenous sleep pathways involves the inhibition of the locus coeruleus in the pons, which facilitates VLPO firing in the anterior hypothalamus.

고연색 백색 광원용 BaSi2O2N2:Eu 형광체의 광학·구조 특성 분석 (Optical and Structural Analysis of BaSi2O2N2:Eu Green Phosphor for High-Color-Rendering Lighting)

  • 이성훈;강태욱;강현우;정용석;김종수;허훈
    • 한국재료학회지
    • /
    • 제29권7호
    • /
    • pp.437-442
    • /
    • 2019
  • Green $BaSi_2O_2N_2:0.02Eu^{2+}$ phosphor is synthesized through a two-step solid state reaction method. The first firing is for crystallization, and the second firing is for reduction of $Eu^{3+}$ into $Eu^{2+}$ and growth of crystal grains. By thermal analysis, the three-time endothermic reaction is confirmed: pyrolysis reaction of $BaCO_3$ at $900^{\circ}C$ and phase transitions at $1,300^{\circ}C$ and $1,400^{\circ}C$. By structural analysis, it is confirmed that single phase [$BaSi_2O_2N_2$] is obtained with Cmcm space group of orthorhombic structure. After the first firing the morphology is rod-like type and, after the second firing, the morphology becomes round. Our phosphor shows a green emission with a peak position of 495 nm and a peak width of 32 nm due to the $4f^65d^1{\rightarrow}4f^7$ transition of $Eu^{2+}$ ion. An LED package (chip size $5.6{\times}3.0mm$) is fabricated with a mixture of our green $BaSi_2O_2N_2$, and yellow $Y_3Al_5O_{12}$ and red $Sr_2Si_5N_8$ phosphors. The color rendering index (90) is higher than that of the mixture without our green phosphor (82), which indicates that this is an excellent green candidate for white LEDs with a deluxe color rendering index.