• 제목/요약/키워드: Firefighting power

검색결과 15건 처리시간 0.018초

건축물의 비상전원 적용실태 및 자가발전설비의 안전 운전 모델에 관한 연구 (Analysis on Emergency Power Supplies in Buildings and a Model for Safe Operation of the Emergency Power System)

  • 이원강;최충석
    • 한국안전학회지
    • /
    • 제27권3호
    • /
    • pp.49-56
    • /
    • 2012
  • The purpose of this paper is to present a model for operating an emergency power system(EPS) that can secure a sufficient power supply used in case of a fire by analyzing the status of power supplies for emergency and firefighting operations. Investigations on the one of the causes of the operational failure of firefighting systems show evidence of EPS. Generally, when power to a building is interrupted, EPS supplies the emergency load(excepted firefighting load) first. When a power outage and a fire occur simultaneously, the EPS must be able to supply both the emergency load and the firefighting load, especially the firefighting load to the end. However, in order to save construction costs, emergency power generators in apartment, commercial, and business buildings can satisfy only one of the required loads. In cases like this, when a power outage and a fire occur simultaneously, there is a danger of firefighting equipment not operating due to insufficient power supply from the emergency generator. Therefore, an EPS must have a reserved firefighting power that can supply both the firefighting and the emergency load. Such EPS, when faced with a danger of an overload, will shut down the supply to all or part of the emergency load, thus securing a continuous power supply to the firefighting equipment. The generator power system with reserved firefighting power (RFP) will also have an indicator to show that the selective control is being used. General power generation systems for emergency load and firefighting load were found to have a demand factor of 50-60% with a lump. However, when installing an EPS, the builders must choose the higher demand factor suggested according to the official approval demand factor of the building.

소방전원보존형 발전기(RFP)의 작동 방법에 관한 연구 (A Study on the Operation Method of Emergency Power System with Reserved Firefighting Power (RFP))

  • 이원강;최충석
    • 한국화재소방학회논문지
    • /
    • 제26권3호
    • /
    • pp.29-34
    • /
    • 2012
  • 본 논문에서는 소방전원 및 소방전원 부족시 용량 보완을 위한 인터록 시스템의 한계점 등을 분석하고 소방전원 보존형 발전기(RFP)의 작동방법 등을 제시하여 화재와 같은 상황에 효율적으로 대응할 수 있는 방법을 제시하는데 있다. 소방전원보존형 발전기에서 일괄제어방식은 발전기에 과부하가 걸리면 소방전원보존용 제어기에서 신호를 발신하여 소방부하는 남겨두고 비상부하용 주차단기를 일괄 차단하고, 발전기가 마지막까지 소방부하에 전원이 공급되도록 한 시스템이다. 순차제어방식은 과부하가 걸리면 소방전원보존용 제어기에서 1차 신호를 발신하여 설정된 비상부하의 1단계 부하를 차단한다. 그리고 지속적인 감시 상태에서 소방부하가 증가하여 발전기가 다시 과부하가 걸리면 제어기에서 2차 신호가 발신하여 비상부하의 2단계 부하를 차단하는 시스템이며 각각의 작동 상태를 표시하는 표시장치를 가진다.

국내발전소 소방안전경영시스템구축을 위한 실태평가에 관한 연구 (Evaluation of the Actual Conditions for the Construction of a Firefighting Safety Management System in Domestic Power Plants)

  • 강길수;최재욱
    • 한국화재소방학회논문지
    • /
    • 제32권1호
    • /
    • pp.89-98
    • /
    • 2018
  • 2015년 베이징 화력발전소 화재사고나 2012년 보령화력과 2016년 태안화력 등 국내 발전소 화재사고, 2011년 후쿠시마 원전참사나 2001년 캘리포니아 대정전은 전력관련 소방안전사고로 국민의 안정적 생활과 국가적인 손실을 가져온 사례로 손꼽고 있다. 전기는 국민생활과 경제에 미치는 영향이 절대적이라 위험성이 높은 대용량의 석탄, 가스 및 원자력 등을 연료로 사용하여 전력을 생산하는 발전소가 안전관리의 소홀로 인한 화재폭발사고나 방사능누출, 지진 등 자연재해로 인한 문제가 생길 경우 국민의 생명보호와 재산손실에 직접적 피해뿐만 아니라 경제성장에 미치는 심각한 상황을 우리는 충분히 예상할 수 있다. 본 연구에서는 한국남부발전 등 5개 발전사 및 한수원 소방안전담당자를 대상으로 발전소 소방안전경영시스템 구축의 필요성에 대한 실태조사를 통해 소방전담조직 보강과 전문역량강화 프로그램 운영, 체계적인 소방안전관리를 위한 발전소 맞춤형 소방안전경영시스템의 개발, 최근 이슈가 된 지진에 대비한 내진 대응체계 강화를 개선방안으로 도출하였다.

국내발전소 소방안전관리 운영실태조사 및 개선방안에 관한 연구 (A Study of the Improvement Plan and Real Condition Estimation of Fire Protection Safety Management for Power Plants in Korea)

  • 강길수;최재욱
    • 한국화재소방학회논문지
    • /
    • 제31권2호
    • /
    • pp.61-73
    • /
    • 2017
  • 2011년 후쿠시마 원전참사나 2001년 캘리포니아 정전사태 등은 전력관련 대형재난사고로 국가적인 막대한 손실을 가져온 발전소 안전관리의 중요성을 재조명하는 사례로 손꼽고 있다. 인간이 지구상에 살고 있는 한 전기가 없이 살 수 없는 상황에서 원자력, 석탄 및 가스 등 대용량의 위험물질을 연료로 전기를 생산하는 발전소가 안전관리의 소홀로 인한 화재폭발사고나 방사능누출, 최근 이슈가 되고 있는 지진 등 자연재해로부터 국민의 생명과 재산손실예방 및 안정적 경제성장을 위해서도 체계적인 소방안전관리의 강화노력은 절대적으로 필요하다. 따라서 본 연구에서는 국내 전력공급을 책임지고 있는 한국남부발전 등 5개 발전사 및 한수원의 소방안전관계자를 대상으로 발전소 소방안전관리 운영실태를 조사하여 분석을 수행하였으며, 그 결과, 체계적인 발전소 소방안전관리를 위해서는 소방안전경영시스템의 구축을 바탕으로 소방담당자를 위한 실효적인 업무매뉴얼 및 관리시스템의 개발과 소방안전교육의 내실화 및 지진에 대비한 내진설계의 강화를 개선방안으로 도출하였다.

의용소방대 조직 활성화 방안에 관한 시론적 연구 (A Preliminary Study on Vitalization Measures for Volunteer Fire Department Organizations)

  • 우성천
    • 한국화재소방학회논문지
    • /
    • 제29권2호
    • /
    • pp.54-63
    • /
    • 2015
  • 의용소방대는 소방업무를 보조하기 위하여 특별시, 광역시, 특별자치시 도(이하 시 도) 시 읍 면에 설치된 민간 소방조직이다. 화재예방 진압은 물론 각종 재난의 방지와 그 수습에도 적극 참여하여 주민의 생명과 재산을 보호하고 지역 발전을 도모하기도 한다. 그러므로 그 지역에 거주하는 주민 중에서 봉사와 희생정신을 가지고 희망하는 자로 하여금 자신의 생업에 종사하면서 소방업무를 보조하고 있는 무보수의 자율적 민간봉사 조직이다. 이러한 숭고하고 참된 의용소방 조직이 활성화 되지 않아 이에 대한 연구가 소방조직 및 학계에서 조심스럽게 진행되어 왔다. 따라서 본 연구 역시 의용소방대 조직의 활성화 방안을 시론적으로 연구함에 있어 신임 의용소방대원 기본 소양교육실시, 의용소방대장 및 대원의 임면권 일원화, 의용소방대원의 정예화, 여성의용소방대원의 활성화 등을 통한 의용소방대의 현 실태의 문제점을 분석하고 이에 대한 활성화 방안을 제시하고자 한다.

A Study on the Analysis of the Power Distance Tendency of Firefighters

  • Hyeon-Gyeong Lee;Kyong-Jin Park
    • 한국산업융합학회 논문집
    • /
    • 제27권2_1호
    • /
    • pp.297-306
    • /
    • 2024
  • This study identified the power distance tendency of firefighters. Power distance propensity is one of the important organizational and cultural factors that influence the development of the organization. There is a big difference in the attitude of the members of the organization to perform their work according to the tendency of the distance of power. As a result of the main study, the overall level of power distance propensity of the subjects was 2.55 points on average. In particular, there was a significant difference in the propensity of power distance according to class (p<0.05). In the future, it is necessary to study the effect of job characteristics according to the rank of firefighters on the propensity to distance power. It is expected to form a positive organizational culture of the firefighting organization by utilizing the power distance tendency of the members of the organization.

원자력발전소 화재에 대한 관할 지역 소방관의 위험인식: 측정도구의 개발과 타당화 (Risk Perception of the Firefighters Responsible for Nuclear Power Plants: Construct Validity)

  • 최해연;이상규;최종안
    • 한국화재소방학회논문지
    • /
    • 제33권5호
    • /
    • pp.94-102
    • /
    • 2019
  • 원전의 안전관리에서 화재 대응의 중요성이 강조되는 시점에서, 화재 대응 인력의 심리적 상태와 역량을 체계적으로 접근할 필요가 있다. 본 연구는 원전 관할 지역 소방관들의 위험인식 구성개념을 규명하고, 이를 측정하는 측정도구를 개발 및 타당화 하였다. 원전 관할 소방관을 대상으로 실시된 인터뷰 분석과 문헌연구를 바탕으로 원전 화재에 대한 위험인식의 문항을 개발하였다. 개발된 문항들에 대한 타당화 연구에는 전라남도, 경상북도 및 부산 소재 원전 관할 소방서 및 119안전센터 5곳에서 참가자를 모집하여 총 180명의 소방관들이 참가하였다. 탐색적 요인분석 결과, 원전 화재의 재난적 결과 및 두려움을 반영하는 '두려움', 원전에서의 화재 및 방사능 누출에 대한 대응 절차와 지침의 부족을 반영하는 '매뉴얼', 원전 화재에 대응할 소방 인력 및 안전장치의 부족을 나타내는 '대응자원', 원전 소방활동을 위한 관계 기관과의 공조와 신뢰를 나타내는 '신뢰', 방사능 및 원전 소방 활동에 대한 지식을 의미하는 '지식'의 5개 요인 구조가 추출되었다. 최종 선별된 15개 문항으로 구성된 척도의 신뢰도와 타당도를 확인하였다. 본 연구 결과를 바탕으로 원전 관할 소방관들의 위험인식의 구성적 특성에 대해서 논의하였다.

소방기관의 행정직과 현장직의 권력거리 성향 비교연구 (Comparative Study of Power Distance Tendency Between Administrative and Field Firefighters in Fire Department)

  • 박경진;김봉길;김현미
    • 한국산업융합학회 논문집
    • /
    • 제27권3호
    • /
    • pp.645-653
    • /
    • 2024
  • This study is a comparative study on the tendency of power distance between administrative and field personnel in fire departments. For this study, 355 firefighters nationwide were surveyed from August 22 to December 31, 2023, and the collected data was analyzed using the SPSS 24.0 statistical program. As a result of the reliability analysis, Cronbach's =.803 was found to be higher than the standard value of 0.6. irefighting agencies are firefighting organizations that work to resolve incidents quickly and efficiently at disaster sites, and an appropriate level of power distance is essential. However, excessive power distance between superiors and subordinates leads to self-righteousness in administration and incompetence in field activities through one-sided instructions and compliance. As a result of analyzing the power distance tendencies of administrative and field workers in fire departments in this study, it was confirmed that there was no bias in either direction with an average score of 2.55. And the level of power distance tendency between administrative and field firefighters was 2.56 points, showing no significant difference.

산불진화헬기 조종사에게 유용한 지리정보의 식별 및 공공 자료로부터의 획득 방안 (Identification of Usable Geographic Information for Pilot of Forest Fire Suppression Helicopter and Its Acquisition from Public Data)

  • 류영기;김만규;박종철
    • 한국지리정보학회지
    • /
    • 제14권3호
    • /
    • pp.52-67
    • /
    • 2011
  • 본 연구는 산불진화헬기 조종사에게 필요한 지리정보를 식별하고, 식별된 지리정보를 공공기관의 자료로부터 획득하는 방안에 대하여 연구하였다. 산불진화헬기 조종사들은 7개의 자연지리 정보와 13개의 인문지리 정보를 필요로 한다. 이 중 국내 공공기관에서 제공하고 있는 지리정보들을 활용했을 때 다음의 15개 정보를 획득할 수 있다. 표고와 주요 고지군, 하천(이상 자연지리 정보), 인구밀집 및 도시지역, 도로, 국립공원경계, 행정경계, 연료 재보급시설, 담수지, 문화재, 가스충전소, 주유소, 탄약고, 지상 송전선, 철탑 정보(이상 인문지리 정보)이다. 자연지리정보 중 조류서식지 정보는 구축이 필요하고 시정, 풍향, 풍속 정보는 제한적으로 획득 가능하므로 보완책이 필요하다. 인문지리정보 중 연료 추진 재 보급지 정보는 공공기관에서 제공하고 있는 지리정보를 활용한 GIS 공간분석으로 획득할 수 있다.

화목 연료 난방설비의 화재 위험 감소 방안에 관한 이론적 연구 (Study on the effective response method to reduce fire risk of wood fuel heating system)

  • 박경진;이봉우;이근출;남기훈
    • 한국산업융합학회 논문집
    • /
    • 제22권2호
    • /
    • pp.163-171
    • /
    • 2019
  • Recently, rural housing in urban areas has been increasing due to the improvement of income level. With the increase of the construction of the power house, the installation of the heating system using the harmonious fuel for the purpose of heating and the beauty of the room is increasing rapidly. In addition to the increasing use of firewood heating equipment, the incidence of fire is also increasing. Analysis of the National Fire Data System of the Fire Department The result of the analysis of the National Fire Data System Many parts of the fire are incinerated by the accumulation of tar due to the incompleteness of periodic cleaning inside the cylinder. The distance between the fire extinguisher and the combustible materials such as ceiling, Resulting in fire. In addition, it was found that much of the fire of the firewood heating system in the time zone occurs during the sleeping and resting time and there is not enough time for the residents to cope. This, in turn, causes serious harm to the lives and property of the users of the pyrotechnic heating system. Therefore, in this study, domestic and foreign standards and laws related to fuel oil heating facilities were analyzed and 12 cases of fire accidents were analyzed. Through the revision of the fire prevention and firefighting facilities installation and maintenance law, the installation standards of the alarm and fire extinguishing facilities were presented.