• Title/Summary/Keyword: Fire-through

Search Result 2,282, Processing Time 0.029 seconds

Problem and Improvement Plan of Existing Fire Examination and Investigation System (현행 화재조사 및 수사체계의 문제점과 개선방안)

  • Kim, Hyung-Doo
    • Fire Science and Engineering
    • /
    • v.21 no.1 s.65
    • /
    • pp.37-50
    • /
    • 2007
  • A primary task of fire department is maintaining public safety, system maintenance and welfare improvement by protecting life, body and property of a people through prevent and extinguish of the fire in emergency. Rescue part of those affairs has supported by the people but affairs related to the fire examination and investigation could not get it. Although fire examination is a very important part of fire department administration, it has been understood indifferently due to lack of awareness and concern. There are no scientific fire examination because of lacking education study and the whole responsibility capacity about it. There are many things have to be improved at fire examination and investigation system in Korea. Especially, establishment of the whole responsibility post is urgent through assuring professionals to improve accuracy of fire examination and investigation. Equipment which can do scientific fire examination and investigation have to be fully furnished. Efficiency of fire examination and investigation has to be increased through improving law related to fire examination and investigation, giving rescuers investigation right. Through this, it systematically have to be good for fire prevent.

A study on the assessment of wildland fire hazard through statistic examination and calorie analysis according to the geographical distribution of vegetation (통계적 고찰과 수목분포에 따른 열량분석을 통한 산림화재 위험성 평가에 관한 연구)

  • 김광일;김동현
    • Fire Science and Engineering
    • /
    • v.14 no.3
    • /
    • pp.27-32
    • /
    • 2000
  • The assessment of wildland fire hazard is the first priority to be considered in the prevention, extinction and control of wildland fire. For the standard to measure wildland fire hazard, the wildland fire Warning System is currently being used in Korea which computes the wildland fire occurrence hazard index through a stick weight to moisture conversion formula. It shows the risk of fuel substance being exposed to fire by meteorological factors. For a comprehensive assessment of wildland fire hazards by area, the major factors'hazards need to be measured and the assessment of wildland fire needs to be conducted through historical statistic examination. Therefore, the wildland (ire outbreak frequency and its seriousness of damage are analyzed through historical statistic examination to conduct the assessment of a wildland fire hazard, and then the calorific value of a forest is analyzed through differential scanning calorimeter measurement which assesses the comparative calorific hazard according to the geographical distribution of vegetation.

  • PDF

Evaluation of the Fire Resistance Performance of Interior Anchor Type CFT Columns through Loaded Heating Test

  • Kim, Sunhee;Yom, Kyongsoo;Choi, Sungmo
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.1
    • /
    • pp.39-48
    • /
    • 2013
  • The fire resistance performance of generic CFT columns has been verified through various tests and analyses and the columns are widely used for fire resistance designs abroad. In this study, 3 groups of specimens (Non-fire protection, reinforcement with steel fiber and fire resistance paint) are suggested in order to evaluate the fire resistance performance of interior anchor type concrete-filled steel tubular columns having efficient cross-sections through loaded heating tests. Axial deformation-time relationship and in-plane temperatures are compared to evaluate the fire resistance performance of the specimens associated with variables. Suggested from the fact that the interior anchors exposed to fire exert influence on fire resistance performance due to thermal expansion, the reinforcements using steel fiber and fire resistance paint are verified to mitigate contraction and improve fire resistance performance. The result obtained from the tests of interior anchor type concrete-filled tubular columns is expected to be used for effective fire resistance design in association with previously conducted studies.

A Study on Fire Safety Management of Social Welfare Facilities (사회복지시설의 화재안전관리에 관한 연구)

  • Choi, Kyu-Chool
    • Fire Science and Engineering
    • /
    • v.27 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • The fire safety of social welfare facilities increasing at high speed with coming-up of an aging society have been on the rise as a very important social problems. This research paper has analyzed the fire safety laws and standards about the social welfare facilities as a lesson elderly nursing home's fire that occurred in recent years. This research worker have conducted the questionnaire survey including research of the true actual through the fire protection engineers, the professors, the fire facilities managers and the users. This study has proposed the installing of suitable fire protection systems through the law revision, normal maintenance of the facilities, the safety management plan through evaluation about fire protective management and related facilities by the methods of the fire safety management.

Synthetic Circumstantial Judgement System Applied Recognition of Fire Levels Model (화재 상황 인식 모델을 적용한 종합 상황 판단 시스템)

  • Song, Jae-Won;Lee, Se-Hee;An, Tae-Ki;Shin, Jeong-Ryol
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1275-1281
    • /
    • 2011
  • This paper presents synthetic circumstantial judgement system that detects and predicts a fire in subway station. Unlike conventional fire surveillance systems that judge the fire or not through smoke, CO, temperature or variation of temperature, a proposed system discovers a fire more easily or gives the alarm high possibility of fire to operator through recognition of fire levels based on Fuzzy Inference System using by FCM and information of objects from video data.

  • PDF

A Study on the Fire Safety of High-rise Apartments Based on Fire Door Switch and Automatic Fire Extinguishing System

  • Zhang, ZeChen;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.424-430
    • /
    • 2021
  • The purpose of this study is to analyse the characteristics and spreading laws of parameters such as fire smoke, concentration of CO, visibility, and temperature at fire scene in high-rise residential buildings under the different conditions of fire doors and automatic fire extinguishing systems. Using Pyrosim to simulate diverse fire scenes in a high-rise apartment with corridors, to analyze the changes in those parameters. The results show that when a fire occurs, closing the fire-fighting corridor will increase the smoke temperature and concentration of CO in the stairwell, and reduce the height and visibility of the smoke layer; the automatic fire extinguishing system effectively suppresses the increase in the temperature of the fire smoke and the sedimentation of the smoke layer. Reasonable setting and operation of the automatic fire extinguishing system could effectively inhibit the spread of fire. Although closing fire corridor can slow down the direct upward spread of smoke through the corridor, it will force the fire smoke into the stairwell, which will seriously affect evacuation through the stairs. Therefore, in order to reduce risks, it is forbidden to close the fire doors of the firefighting corridor and stacking combustible materials in the corridor, Also, intensifying inspections and ensuring the normal operation of the automatic fire extinguishing system are indispensable. Based on the research results, the significance of installing fire-fighting facilities in the construction of high-rise apartments was discussed and proved.

A Study on the Analysis of Cause Investigation of Fire and Safety Countermeasures of Elderly Facilities (고령자시설 화재안전을 위한 화재원인조사 및 안전대책 방안에 관한 연구)

  • Jin, Seung-Hyeon;Lee, Byeong-Heun;Koo, Tae-Yoon;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.148-149
    • /
    • 2017
  • Recently, South Korea is reaching aged society through ageing society. Accordingly, facility related to aged is increased consistently because of effort to improve the welfare of the elderly through elderly long term care insurance in 2008. however, the number of fires in the elderly facilities is increasing rapidly too. It is becoming bigger and higher and the characteristics of person who is unable to afford are mostly having difficult evacuation. so fire safety guildelines are urgently needed but korea research is insufficient. In this study, we propose a fire scenario through investigation of fire causes for fire safety guideline development of elderly facility, and describe to the fire safety countermeasure.

  • PDF

Development of User-centered Fire Safety Evaluation Model for School Buildings (교육시설의 사용자 중심 화재안전수준 평가모형 개발)

  • Park, Sung-Chul;Kim, Jin-Wook
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.238-239
    • /
    • 2021
  • This study presented the development of a user centered school facility fire safety evaluation model that would support fire safety evaluation, which is globally recognized as being important in terms of school safety, to be more efficiently implemented in the school field mainly by students. The study consisted of five steps. First, actual condition survey tools were developed based on the major fire safety evaluation items derived through literature review. Second, the characteristics of domestic school facilities in terms of fire safety were developed using the survey tools. Third, an evaluation model at a level utilizable by students was developed based on the foregoing characteristics. Fourth, the applicability of the model was verified through a trial application of the model to elementary school students. Finally, legal and institutional improvement plans and fire safety education materials were presented through a policy proposal.

  • PDF

A Study on the fire-resistance of concrete-filled steel square tube columns without fire protection under constant central axial loads

  • Park, Su-Hee;Choi, Sung-Mo;Chung, Kyung-Soo
    • Steel and Composite Structures
    • /
    • v.8 no.6
    • /
    • pp.491-510
    • /
    • 2008
  • This paper presents a plan and guidelines that were drawn for Korean based research carried out on the fire-resistance of CFT columns. This research was carried out by reviewing the Korean regulations related to the fire-resistance of CFT columns and examining studies which had been made in Korea as well as overseas. The first phase of the study plan was to compare the fire-resistance of square CFT columns without fire protection (obtained through fire-resistance tests and numerical analyses) with estimated values (obtained through fire-resistance design formulas proposed in Korea and overseas). This comparison provided conclusions as outlined below. Fire-resistance tests conducted in this study proved that, when the actual design load is taken into consideration, square CFT columns without fire protection are able to resist a fire for more than one hour. A comparison was made of test and analysis results with the fire-resistance time based on the AIJ code, the AISC design formula and the estimation formula suggested for Korea. The results of this comparison showed that the test and analysis results for specimens SAH1, SAH2-1, SAH2-2 and SAH3 were almost identical with the AIJ code, the AISC design formula and estimation formula. For specimens SAH4 and SAH5, the estimation formula was more conservative than the AIJ code and the AISC design formula. It was necessary to identify the factors that have an influence on the fire-resistance of CFT columns without fire protection and to draw fire-resistance design formulas for these columns. To achieve this, it is proposed that numerical analyses and tests be conducted in order to evaluate the fire-resistance of circular CFT columns, the influence of eccentricity existing as an additional factor and the influence of the slenderness ratio of the columns. It is also suggested that the overall behavior of CFT structures without fire protection within a fire be evaluated through analysis simulation.