• Title/Summary/Keyword: Fire-prevention

Search Result 1,580, Processing Time 0.026 seconds

Analysis of changes in air consumption according to water depth in underwater search (수중수색 시 수심에 따른 공기소모량의 변화 분석)

  • Jeon, Jai-In;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.1
    • /
    • pp.433-439
    • /
    • 2020
  • This study compared and analyzed the change of air consumption according to water depth with human characteristics and theoretical values. The experimental results are as follows. First, subjects A and B showed similar rise rates depending on the water depth. Second, subject C had a significantly higher rate of increase in air consumption at 25m underwater because the body responded sensitively to deep water pressure, which increased air consumption because breathing was faster than other participants. Third, the subjects D and E showed significantly lower overall air consumption. D and E were 37 and 35 years of age, respectively, the youngest, strongest and most experienced in deep sea diving at the time of military service. Fourth, the average air consumption per minute of the test subjects increased from 5m in water to 1.45 times, 10m in water to 1.85 times, and 20m in water to 2.8 times. This seems to be a result of different experiences, physical fitness, the degree of adaptation of the body to underwater, and different breathing techniques. Lastly, the difference between the experimental average value and the theoretical value appears to be the result of using more or less air than the theoretical value depending on the experiences and physical strength of each of the 5 rescuers, the degree of adaptation of the body underwater, and the method of underwater breathing.

Effects of the Safety and Health Management System on the Performance of the Enterprise: Focus on the Electric Power Corporation (안전보건경영시스템의 운영방침이 기업성과에 미치는 영향: 전기공사업을 중심으로)

  • Kim, Sang-Sig;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.1
    • /
    • pp.135-145
    • /
    • 2020
  • This research is mainly aimed at finding out about the effects of the safety and health management system on corporate performance through systematic operation by efficiently allocating material and human resources within the company by participating all employees and stakeholders in order to prevent and maintain industrial accidents and the optimal working environment, and how to maintain and activate the safety and health management system at the center of electric contractors.The analysis results are as follows. First, management, organizational management and resource preparation will have a positive impact on the management capability of the electric power corporation. It was assessed that the more well-transmitted and understood within the organization, the better the construction plan, the better the equipment management status, the more positively the management capability of electric works was to be achieved. Second, management, organizational management and resource preparation will have a positive impact on corporate management performance.This seems to have a positive effect on a company's business performance when the standards of OHSAS are met with construction plan and construction equipment management are high as related information such as industrial safety and health laws are strengthened and companies' safety and health activities, advanced safety and culture are released to facilitate organizational management.Third, the management ability of the electric power corporation will have a mediated effect on the effect of management, organization management and resource preparation on the performance of the enterprise. This means that the direct effect of the independent variable management organization on corporate management performance is .401 The indirect effect is .168.658 shows that the direct effect of resource preparation on corporate management performance is .423, the indirect effect is .178 and the total effect.It was analyzed at 643.

An Analysis of the Appropriate Number of People Per Apartment Household According to NFPA 101 (NFPA 101에 의한 아파트 한 세대당 적정 수용인원 분석)

  • Cho, Ji-Eun;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.331-337
    • /
    • 2020
  • The study analyzes the appropriate number of people per a household by applying an evacuation simulation to a 27-floor apartment in accordance with the NFPA 101 standard. The results of the analysis are as follows. First, if there are three people residing in each household, there would be 156 households in total, of which 85.25% were evacuated within 5 minutes. Second, 208 households with 4 residents were evacuated within 5 minutes. Third, if there are five people residing in each household, there would be a total of 260 households and 71.92% of residents were evacuated within 5 minutes. Lastly, 62.82% of the 312 households, each consisting of 6 people, were evacuated within 5 minutes. Measures to reduce evacuation time include determining the width of the stairs according to the number of people indoors, the number of floors in the building, the slope of stairs, and the users' characteristics, the design reflecting the ventilation conditions of the stairs, the installment of outdoor evacuation stairs, two-way stairs, evacuation lift, and the installation of an evacuation safety zone for people to evacuate outside of the building in the middle floors. In addition, measures, such as the mandatory installation of automatic emergency door open-close device to the rooftop, are required to facilitate rooftop evacuation.

Child-Care Facility and Kindergarten's Demands on Foodservice Support by Center for Child-Care Foodservice Management (CCFSM) in Seoul and Gyeonggi-do (서울.경기지역 보육시설 및 유치원 대상 어린이급식관리지원센터 지원 요구도 분석)

  • Kim, Soo-Youn;Yang, Il-Sun;Yi, Bo-Sook;Baek, Seung-Hee;Shin, Seo-Young;Lee, Hae-Young;Park, Moon-Kyung;Kim, Young-Shin
    • Korean Journal of Community Nutrition
    • /
    • v.16 no.6
    • /
    • pp.730-739
    • /
    • 2011
  • The purpose of this study was to analyze the differences between child-care facilities and kindergartens towards the need for foodservice support by Center for Child-Care Foodservice Management (CCFSM). For this study, questionnaires were sent out from August of 2008 to April of 2009 to directors of 1,478 child care facilities and 299 kindergartens in Seoul and Gyeonggi-do via postal service. A total of 267 questionnaires were usable with 203 (13.7%) of child-care facilities and 64 (21.4%) of kindergartens. Statistical data were analyzed by SPSS 15.0 for descriptive analysis and t-test. For political and administrative support, government funding for foodservice was the highest need and hiring nutritionists was significantly different by type of facility (p < 0.01). Both child-care facilities (4.29) and kindergartens (4.41) demanded the balanced menu from CCFSM. There were significant differences of "information about food material sanitation management" (p < 0.05), "hygiene safety management method according to working process" (p < 0.05), "hygiene safety management method of foodservice facilities and equipment" (p < 0.05). In education and training contents from center, "types and methods to manage foodservice facilities and equipment" for directors, "dietary education by age" for teachers, and "the rules of personal sanitation and working process" and "gas, electricity and fire prevention" for culinary workers had the highest mean score of requirements.

Step-down Piezoelectric Transformer Using PZT PMNS Ceramics

  • Lim Kee-Joe;Park Seong-Hee;Kwon Oh-Deok;Kang Seong-Hwa
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.3
    • /
    • pp.102-110
    • /
    • 2005
  • Piezoelectric transformers(PT) are expected to be small, thin and highly efficient, and which are attractive as a transformer with high power density for step down voltage. For these reasons, we have attempted to develop a step-down PT for the miniaturized adaptor. We propose a PT, operating in thickness extensional vibration mode for step-down voltage. This PT consists of a multi-layered construction in the thickness direction. In order to develop the step-down PT of 10 W class and turn ratio of 0.1 with high efficiency and miniaturization, the piezoelectric ceramics and PT designs are estimated with a variety of characteristics. The basic composition of piezoelectric ceramics consists of ternary yPb(Zr$_{x}$Ti$_{1-x}$)O$_{3}$-(1-y)Pb(Mn$_{1/3}$Nb1$_{1/3}$Sb$_{1/3}$)O$_{3}$. In the piezoelectric characteristics evaluations, at y=0.95 and x=0.505, the electromechanical coupling factor(K$_{p}$) is 58$\%$, piezoelectric strain constant(d$_{33}$) is 270 pC/N, mechanical quality factor(Qr$_{m}$) is 1520, permittivity($\varepsilon$/ 0) is 1500, and Curie temperature is 350 $^{\circ}C$. At y = 0.90 and x = 0.500, kp is 56$\%$, d33 is 250 pC/N, Q$_{m}$ is 1820, $\varepsilon$$_{33}$$^{T}$/$\varepsilon$$_{0}$ is 1120, and Curie temperature is 290 $^{\circ}C$. It shows the excellent properties at morphotropic phase boundary regions. PZT-PMNS ceramic may be available for high power piezoelectric devices such as PTs. The design of step-down PTs for adaptor proposes a multi-layer structure to overcome some structural defects of conventional PTs. In order to design PTs and analyze their performances, the finite element analysis and equivalent circuit analysis method are applied. The maximum peak of gain G as a first mode for thickness extensional vibration occurs near 0.85 MHz at load resistance of 10 .The peak of second mode at 1.7 MHz is 0.12 and the efficiency is 92$\%$.

Development of the Standard Model of a Stated Period Check and Precise Safety Diagnosis in the Research Lab for Prevention to Electrical Accidents (전기사고방지를 위한 연구실험실 정기점검/정밀안전진단 표준모델개발)

  • Lee, Dong-Yoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.858-864
    • /
    • 2011
  • There is no standard model for a Stated Period Check and a Precise Safety Diagnosis to remove electric fire and shock in the university Lab and institute. Especially, the research for the Stated Period Check and the Precise Safety Diagnosis of the Lab related to electrical field is very weak currently, and it is very necessary to build a detail safety plan. This paper informs the specific standard guideline of the safety check list, method and equipment and it shows the way to evaluate safety grade too. This paper also provides the information of R&D process through the analysis of electrical safety check list of ordinary R&D Lab. It shows a new detail guideline to R&D Lab, and the new guideline removes existing problem and deliver the effective standard model to each R&D Lab. The standard model developed in this research adopts the clear guideline of each check list for the electrical environment of current R&D Lab. This standard model can be applied for every R&D Lab to detect routine safety check and detail safety check immediately. This Research will generally improve not only the effective safety check, but also the safety level for R&D Lab to prevent the electrical accidents.

A Study on the Ecological Restoration Strategies for the Disturbed Landscapes (경관훼손지의 생태적 복구방안에 관한 연구)

  • Kim, Nam-Choon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.1 no.1
    • /
    • pp.28-44
    • /
    • 1998
  • This study was conducted to suggest the ecological restoration strategies for the disturbed landscapes by theoretical study. Especially, it is aimed to suggest three objectives for restoration by using native plants ; (1) prevention or reduction of wind and water erosion, (2) provision of food and cover for variety of animal species, (3) improvement of the visual or aesthetic quality of disturbed sites. The main results were summarized as follows. 1. Cooperation between restoration ecologists and restoration practitioners is needed to delineate a scientific approach to restoration ; (1) Being aware of published literature that describes similar work and/or establish general principles. (2) Preparedness to carry out proper experiments to test ideas. (3) Preparedness to monitor fundamental parameters in a restoration scheme. (4) Providing information about the behavior of species. (5) Publish results. 2. There are three models of succession in theories of plant succession. The tolerance and facilitation models were recommended to ecological restoration. The inhibition model applies in most secondary succession, but the actual species which are introduced first may inhibit the germination and growth of slower-growing species, or they may prevent the growth of other species whose propagules arrive later. 3. The objectives of erosion control, wildlife habitat provision, and visual quality improvement are not mutually exclusive. However, many revegetation practices in the past have emphasized one of these aspects at the expense of the others. 4. A native plant community can be the model of ecological restoration. By stylization/abstraction of native plant community, trying to learn the most essential characteristics of community types - environmental factors ; dominant, prevalent, and "visual essence" species composition - in order to use such information in restoration. 5. After developing mass/spaces plan, match plant communities to the mass/space plan. In utilizing community grouping, there needs aesthetic ability to understand design elements. 6. Several hydrophytes such as Pennisetum saccharifluous, Themeda triandra, Cirsium pendulum show relatively good germination rates. In case of mesophytes and xerophytes, Arundinella hina, Artemisia princeps, Oenothera odorata and legumes seem to have quick-germinating abilities at barren sites. Pinus thunbergii, Rhus chinensis, Evodia daniellii, Alnus firma and Albizzia julibrissin can be considered as "late succession" woody plants because they show low germinating rates and slow growing habitat. 7. The seeds used for restoration should be collected within a certain radius of where it will be planted. Consideration in genetic issues in the collection and use of germplasm can increase the odds for successful restoration efforts. 8. The useful model in the "drift" pattern occurs so abundantly in naturally evolving landscapes. As one species diminishes in density, a second or third species are increased. Thus, dynamic interactions between species are created. Careful using of "drift phenomenon" in planting was recommended. 9. Virtually no stand of vegetation today is immune from the introduction and/or spreading of exotic species. Therefore, the perpetuation of a restored sites requires conscious monitoring and management. Thus, management would be the most important process in ecological restoration. 10. In order to keep the sites "natural", alternative management strategies would be applied in management ; Atenative management strategies are decelerating successional process, accelerating successional processes or modifying species composition. As management tools, mechanical, chemical, biological or environmental factor manipulation, e.g., fire could be used.

  • PDF

A Study on the Durability Performance of a Receptacle for CNG Vehicles (천연가스 차량용 리셉터클의 내구성능에 관한 연구)

  • Choi, Young;Kim, Young-Min;Lee, Yong-Gyu;Lee, Jang-Hee
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.6
    • /
    • pp.15-20
    • /
    • 2010
  • Compressed Natural Gas (CNG) buses have been supplied since the year 2000 in order to resolve severe atmospheric pollution in metropolitan area and contributed on the improvement of urban atmospheric environment. However, it is indispensible to take an adequate measure to guarantee the safety of CNG vehicles because of the possibility of huge fire accident. A receptacle, connecting device between high pressure fuel supply tank and fuel line, plays an important role in CNG supply system. In recent, leakage of CNG from receptacles has been reported. So, the concern about the security and reliability of receptacles has been arisen. Therefore, a lot of efforts to prevent leakage are invested among researchers and the durability of this component should be guaranteed despite repeated operation. This research has performed durability tests of a CNG receptacle regarding the repeated usage, extreme chattering, and continuous full flow test. Although a receptacle used for CNG vehicle satisfies validation requirements in the test results, it has been found that failure in the function of leakage prevention in a receptacle could take place in the case of prolonged exposure to high supply pressure in common quick charging environment on site.

Effects of Metal Oxide Addition on Co-pyrolysis of PVC and ABS Mixtures (PVC와 ABS 혼합물의 공열분해에 대한 금속산화물의 첨가 효과)

  • Kim, Hee Taik;Choung, Youn Wook;Lee, Hae Pyeong
    • Applied Chemistry for Engineering
    • /
    • v.16 no.2
    • /
    • pp.296-303
    • /
    • 2005
  • The co-pyrolysis characteristics of polyvinylchloride (PVC) and acrylonitrile butadiene styrene (ABS) mixtures with various mixing ratios and effect of addition of CaO and $Cu_2O$ have been studied using thermogravimetry (TG) and gas chromatograph-mass spectrometry (GC-MS). In an isothermal decomposition conducted at $500^{\circ}C$, the yields of styrene monomers and aromatic compounds increased as the mixing ratio of ABS increased, and the yield of BTX compounds reached its maximum (16.14%) when the mixing ratios of PVC and ABS was 4:1. In an isothermal decomposition added with metal oxides, the maximum yield of liquid product was 73% when CaO [CaO/(PVC+ABS)=0.4] was added and it was 70% when $Cu_2O$ [$Cu_2O$/(PVC+ABS)=0.4] was added, respectively, where HCl contained in the gaseous product was completely removed when added with CaO [CaO/(PVC+ABS)=0.5] and $Cu_2O$ [$Cu_2O$/(PVC+ABS)=1.0]. Therefore, to obtain the highest yield of liquid product it appears to be the reaction condition: the reaction temperature of $500^{\circ}C$ and mixing ratios of CaO and $Cu_2O$ are 0.5 and 1.0, respectively.

Control of Suspended Dust in Various Ventilation Systems of Cement Packaging Process (시멘트 포장공정에서 환기시스템에 따른 발생분진의 제어)

  • Lee, Seung-Chul;Kim, Soo-Chang;Noh, Kwang-Chul;Park, Myoung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.3
    • /
    • pp.463-469
    • /
    • 2009
  • We performed the experimental study on the control of suspended dust in a cement packaging process for various ventilation systems. To effectively remove the dust generated in the cement packaging process, three different kinds of ventilation system, such as local exhaust ventilation, electrostatic scrubber, and local air supply system, were adopted. Dust concentrations in the packaging process were measured with the variation of the airflow rate of the ventilation systems and then their ventilation performance were evaluated. From the results, we knew that the ventilation performance was the best when the local exhaust ventilation and the electrostatic scrubber were simultaneously operated in the packaging process. In the electrostatic scrubber system, the effect of the airflow rate on the indoor dust removal efficiency was negligible so hat he system ust be operated at $2,700m^3/h$ for saving power consumption.