• Title/Summary/Keyword: Fire-Performance

Search Result 2,063, Processing Time 0.027 seconds

An Analysis on the Prehospital Care of 119 Emergency Medical Service squads in Gyeonggi Area and Improvement Methods - Focusing on Prehospital Care - (경기도지역 119안전센터의 구급활동 현황과 개선방안 - 현장 응급처치 내역을 중심으로 -)

  • Choi, Keun-Myung
    • The Korean Journal of Emergency Medical Services
    • /
    • v.12 no.3
    • /
    • pp.55-69
    • /
    • 2008
  • Purpose : The purpose of this study was to analyze the prehospital care report prepared by EMS squads of 119 center in Gyeonggi area and to identify the status of prehospital care activities, problems and improvement possibilities of the emergency care. Method : Five hundred copies of prehospital care report prepared by EMS squads in thirty-eight 119 centers under 18 fire stations in Gyeonggi area from March to April in 2008 were randomly chosen for the analysis. Data abstracted according to the purpose of the study were input and the analysis of prehospital care activities were performed using SPSS-WIN(ver. 16) statistics package. Results : 1. Total 500 cases of prehospital emergency care activities were reviewed. By sex, females were 219 (43.8%) and males were 281 (56.2%). The places of reporting were home (57.8%). According to the type of emergency, 281 cases (56.2%) were caused by disease and 291 (43.8%) were from other causes such as traffic accidents or incidental injuries. 2 The average time needed for the 119 EMS squad to arrive at the scene after being reported was 7.29 minutes. The time used at the scene for the emergency care was 7.3 minutes in average and the time to arrive at the hospital was 25.4 minutes in average. 3. In patient evaluation, in 68% of the cases more than two vital signs were measured at one time and emergency patients were 31%, and non-emergency patients were 69%. 4. In one EMS activity, average 2.15 cases of emergency care were provided to a patient. The cases where two kinds of emergency care were given were 14.4%, which is the most frequent cases. When reviewing the details of the emergency cares given to the patient including multiple cares, trivial cards (taking it easy and giving comfort) were the most frequent one as 40.6% and the medical direction of the doctor was given in only one case out of 500 cases. 5. In patient evaluation and emergency care, vital signs were provided to emergency patients at significantly higher rate comparing to the non-emergency patients. The number of emergency care performance was significantly higher in emergency cases. In emergency dispatch, the cases that EMT (1st class) was on board was 86.2%. When comparing the cases when the 1st class EMT was on board and otherwise, the cases with the presence of 1st class EMT showed more vital signs were detected but there was no significant difference in the number of emergency cares provided. Conclusion : It seemed that the on-scene emergency care did not satisfy the expectations. So it is necessary to enforce the cooperation between the elements, the qualifications of the 119 EMS squads and to improve the prehospital working environment in order to provide the better medical service at any time.

  • PDF

Electrical Properties of BaTiO3-based 0603/0.1µF/0.3mm Ceramics Decoupling Capacitor for Embedding in the PCB of 10G RF Transceiver Module

  • Park, Hwa-sun;Na, Youngil;Choi, Ho Joon;Suh, Su-jeong;Baek, Dong-Hyun;Yoon, Jung-Rag
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1638-1643
    • /
    • 2018
  • Multi-layer ceramic capacitors as decoupling capacitor were fabricated by dielectric composition with a high dielectric constant. The fabricated decoupling capacitors were embedded in the PCB of the 10G RF transceiver module and evaluated for the characteristics of electrical noise by the level of AC input voltage. In order to further improve the electrical properties of the $BaTiO_3$ based composite, glass frit, MgO, $Y_2O_3$, $Mn_3O$, $V_2O_5$, $BaCO_3$, $SiO_2$, and $Al_2O_3$ were used as additives. The electrical properties of the composites were determined by various amounts of additives and optimum sintering temperature. As a result of the optimized composite, it was possible to obtain a density of $5.77g/cm^3$, a dielectric constant of 1994, and an insulation resistance of $2.91{\times}10^{12}{\Omega}$ at an additive content of 5wt% and a sintering temperature of $1250^{\circ}C$. After forming a $2.5{\mu}m$ green sheet using the doctor blade method, a total of 77 layers were laminated and sintered at $1180^{\circ}C$. A decoupling capacitor with a size of $0.6mm(W){\times}0.3mm(L){\times}0.3mm(T)$ (width, length and thickness, respectively) and a capacitance of 100 nF was embedded using a PCB process for the 10G RF Transceiver modules. In the range of AC input voltage 400mmV @ 500kHz to 2200mV @ 900kHz, the embedded 10G RF Transceiver modules evaluated that it has better electrical performance than the non-embedded modules.

Design and Verification of Housing and Memory Board for Downsizing for Crash Protected Memory Module (충돌보호메모리모듈의 소형화를 위한 하우징 및 메모리 보드 설계와 검증)

  • Kim, Jun-Hyoung;Kim, Jung-Pil;Kim, Jeong-Yeol;Kim, Tae-Won
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.1
    • /
    • pp.81-88
    • /
    • 2020
  • Flight data recorder is a equipment that records data required for investigation of aircraft accidents and should be developed in compliance with the ED-112A standard. Unlike general data storage device, flight data recorder must be able to recover data after an aircraft accident, requiring a housing and a memory board to protect data in extreme environments. To attain this performance, we designed a housing that can withstand the test by analyzing the physical environment of the impact, shear/tensile, penetration resistance and static crush test of the crash survival test and minimized the size and weight compared to the existing one in consideration of the installation of the aircraft in this paper. Insulation material and thermal block material were applied to endure high and low temperature fire so that the internal temperature does not rise above 150℃ even in 260℃, 10 hour environment. In addition, the memory board is designed to minimize the size and we devise a hoping programming method to prevent continuous data loss of more than 16 seconds. Through this, Crash protected memory module that satisfies ED-112A was completed.

A Study on the Durability Performance of a Receptacle for CNG Vehicles (천연가스 차량용 리셉터클의 내구성능에 관한 연구)

  • Choi, Young;Kim, Young-Min;Lee, Yong-Gyu;Lee, Jang-Hee
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.6
    • /
    • pp.15-20
    • /
    • 2010
  • Compressed Natural Gas (CNG) buses have been supplied since the year 2000 in order to resolve severe atmospheric pollution in metropolitan area and contributed on the improvement of urban atmospheric environment. However, it is indispensible to take an adequate measure to guarantee the safety of CNG vehicles because of the possibility of huge fire accident. A receptacle, connecting device between high pressure fuel supply tank and fuel line, plays an important role in CNG supply system. In recent, leakage of CNG from receptacles has been reported. So, the concern about the security and reliability of receptacles has been arisen. Therefore, a lot of efforts to prevent leakage are invested among researchers and the durability of this component should be guaranteed despite repeated operation. This research has performed durability tests of a CNG receptacle regarding the repeated usage, extreme chattering, and continuous full flow test. Although a receptacle used for CNG vehicle satisfies validation requirements in the test results, it has been found that failure in the function of leakage prevention in a receptacle could take place in the case of prolonged exposure to high supply pressure in common quick charging environment on site.

Design of detection method for smoking based on Deep Neural Network (딥뉴럴네트워크 기반의 흡연 탐지기법 설계)

  • Lee, Sanghyun;Yoon, Hyunsoo;Kwon, Hyun
    • Convergence Security Journal
    • /
    • v.21 no.1
    • /
    • pp.191-200
    • /
    • 2021
  • Artificial intelligence technology is developing in an environment where a lot of data is produced due to the development of computing technology, a cloud environment that can store data, and the spread of personal mobile phones. Among these artificial intelligence technologies, the deep neural network provides excellent performance in image recognition and image classification. There have been many studies on image detection for forest fires and fire prevention using such a deep neural network, but studies on detection of cigarette smoking were insufficient. Meanwhile, military units are establishing surveillance systems for various facilities through CCTV, and it is necessary to detect smoking near ammunition stores or non-smoking areas to prevent fires and explosions. In this paper, by reflecting experimentally optimized numerical values such as activation function and learning rate, we did the detection of smoking pictures and non-smoking pictures in two cases. As experimental data, data was constructed by crawling using pictures of smoking and non-smoking published on the Internet, and a machine learning library was used. As a result of the experiment, when the learning rate is 0.004 and the optimization algorithm Adam is used, it can be seen that the accuracy of 93% and F1-score of 94% are obtained.

An Experimental Study on the Flexural Strength of Lap Spliced Ultra High Strength Fiber Reinforced Concrete Beams (이음된 초고강도 강섬유보강콘크리트 보의 휨강도에 관한 실험적 연구)

  • Bae, Baek-Il;Son, Dong-Hee;Choi, Hyun-Ki;Jung, Hyung-Suk;Choi, Chang-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.76-83
    • /
    • 2021
  • This study examines the bending behavior of lap-spliced ultra-high-strength fiber-reinforced concrete members and evaluates the safety of the design codes for ultra-high-strength fiber-reinforced concrete structures. An experiment on a total of six beams was performed. The main variables were the fiber-inclusion and the lap-spliced length at the center of the beams. The steel fibers in a volume fraction of 2% were used, and the lap-splice lengths were determined to be 8db and 16db. As a result of the test, the specimens not reinforced with fiber lost abrupt load-bearing capacity at the lap region and did not experience yielding of the reinforcing bar. In the case of fiber-reinforced concrete, if a lap-splice length of 16db is secured, the yielding of the main reinforcing bar can be experienced, and appropriate flexural strength can be expressed. Based on the experimental results of this study, as a result of reviewing the lap-splice length calculation formulas of the current design standards and the ultra-high-strength concrete structural design recommendations, it was found that all of them were evaluated conservatively.

Comparison of the Perception of Each Participant on Quality Control Factor of Form Work (거푸집 공사 품질관리 요인에 대한 공사 참여 주체별 인식 비교)

  • Kim, Ju-Yong;Choi, Gyu-Jung;Park, Soon-Kyu;Shin, Yoon-Seok;Kim, Beak-Joong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.520-528
    • /
    • 2021
  • In this study, we attempted to derive major management factors related to the quality control of formwork and identified differences in the perceptions of construction engineers, construction managers, and field workers about the importance and performance of the derived factors. As a result of the study, 18 management factors related to the formwork were derived. Among the derived factors, the field workers placed importance on the factors that influence the detailed process of the formwork, while construction engineers placed importance on the factors related to the judgment of the progress and completion of the construction. The construction managers placed importance on the factors that affect the quality of the building frame. Based on the results of this study, it is expected that a plan to improve the quality of formwork that accepts the various opinions of each participant will be established.

Development of a deep-learning based automatic tracking of moving vehicles and incident detection processes on tunnels (딥러닝 기반 터널 내 이동체 자동 추적 및 유고상황 자동 감지 프로세스 개발)

  • Lee, Kyu Beom;Shin, Hyu Soung;Kim, Dong Gyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.1161-1175
    • /
    • 2018
  • An unexpected event could be easily followed by a large secondary accident due to the limitation in sight of drivers in road tunnels. Therefore, a series of automated incident detection systems have been under operation, which, however, appear in very low detection rates due to very low image qualities on CCTVs in tunnels. In order to overcome that limit, deep learning based tunnel incident detection system was developed, which already showed high detection rates in November of 2017. However, since the object detection process could deal with only still images, moving direction and speed of moving vehicles could not be identified. Furthermore it was hard to detect stopping and reverse the status of moving vehicles. Therefore, apart from the object detection, an object tracking method has been introduced and combined with the detection algorithm to track the moving vehicles. Also, stopping-reverse discrimination algorithm was proposed, thereby implementing into the combined incident detection processes. Each performance on detection of stopping, reverse driving and fire incident state were evaluated with showing 100% detection rate. But the detection for 'person' object appears relatively low success rate to 78.5%. Nevertheless, it is believed that the enlarged richness of image big-data could dramatically enhance the detection capacity of the automatic incident detection system.

Analysis of Electrical Characteristics of CCFL Exit Light (CCFL유도등의 전기적 특성 분석)

  • Jung, Jong-Jin
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.184-193
    • /
    • 2021
  • Purpose: In this study, since the operation principle of the CCFL Exit light is the same as that of general lighting equipment, the characteristics of the CCFL Exit light were analyzed by deriving test items that can affect the characteristics of the light source from the KS standard, which is the standard for lamp ballast performance certification of general lighting equipment. Method: The samples used in the experiment were performed on products of two manufacturers for each size, such as large, medium, and small, and the test items were power factor, crest factor, and current harmonic distortion. Result: As a result of the experiment, the power factor showed a value between 0.4 and 0.6 in all samples, which was smaller than the 0.9 value set by KS. The crest factor ranged from 3.6 to 3.7 for large, 4.4 to 4.7 for medium, and 3.5 to 3.7 for small. It showed a value more than two times higher than the KS standard of 1.7. Current total harmonic distortion ranged from 81% to 110%, and considering that the KS standard was less than 20%, it could be confirmed that all samples had a value significantly exceeding the KS standard. Conclusion: The crest factor and current total harmonic distortion may affect the temperature rise of the light source and the burnout of the device. When developing an exit light, if this item is developed within the scope of the KS standard, the quality improvement and maintenance of the exit light will be greatly improved.

Development of Adsorbent for Vapor Phase Elemental Mercury and Study of Adsorption Characteristics (증기상 원소수은의 흡착제 개발 및 흡착특성 연구)

  • Cho, Namjun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.1-6
    • /
    • 2021
  • Mercury, once released, is not destroyed but accumulates and circulates in the natural environment, causing serious harm to ecosystems and human health. In the United States, sulfur-impregnated activated carbon is being considered for the removal of vapor mercury from the flue gas of coal-fired power plants, which accounts for about 32 % of the anthropogenic emissions of mercury. In this study, a high-efficiency porous mercury adsorption material was developed to reduce the mercury vapor in the exhaust gas of coal combustion facilities, and the mercury adsorption characteristics of the material were investigated. As a result of the investigation of the vapor mercury adsorption capacity at 30℃, the silica nanotube MCM-41 was only about 35 % compared to the activated carbon Darco FGD commercially used for mercury adsorption, but it increased to 133 % when impregnated with 1.5 % sulfur. In addition, the furnace fly ash recovered from the waste copper regeneration process showed an efficiency of 523 %. Furthermore, the adsorption capacity was investigated at temperatures of 30 ℃, 80 ℃, and 120 ℃, and the best adsorption performance was found to be 80 ℃. MCM-41 is a silica nanotube that can be reused many times due to its rigid structure and has additional advantages, including no possibility of fire due to the formation of hot spots, which is a concern when using activated carbon.