• 제목/요약/키워드: Fire-Extinguishing System

검색결과 233건 처리시간 0.023초

불활성계와 할로카본계 복합 소화약제 및 소화시스템 개발 (Inert and Halogenated compounds Fire Fighting Agent And Fire Fighting System Research)

  • 최근주;안상수;김종원;정종진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2009년도 춘계학술논문발표회 논문집
    • /
    • pp.165-171
    • /
    • 2009
  • A compound agent that mixes inert gas agents and halocarbon agents and a complex fire suppression system using the compound agent have been developed. The ultimate goal of this study is to develop the extinguishing agent which doesn't destroy the ozone layer and has low GWP and to develop the fire suppression system. As a result of the test and research for inert gas agents and halocarbon agents, nitrogen and FK-5-1-12 were selected finally and have been tested and studies for three years. Thus, the optimal extinguishing agent and fire suppression system have been accomplished. The performance of the agent and system was tested according to KFI performance test technical standards for gas fire extinguishing system and the fitness of the agent and system for a fire was certified by Korea Fire Industry Technology Institute (KFI).

  • PDF

가스계 소화설비의 개구부 보충량 추정에 대한 연구 (A Study on Estimating of Additional Gas for the Unencloseable Openings of The Gaseous Extinguishing Systems)

  • 정기신
    • 한국화재소방학회논문지
    • /
    • 제26권6호
    • /
    • pp.1-6
    • /
    • 2012
  • 이산화탄소의 소화설비에는 개구부에 대한 소화약제 보충에 대해 구체적인 지침이 있다. 하지만 다른 가스설비, 청정소화약제 설비에는 필요한 경우 적용하라는 원칙 외에 구체적인 조항이 없다. 따라서 이 연구는 이산화탄소의 개구부 약제 추가 공식을 우리가 현제 사용하고 있는 다른 가스계 소화약제에 적용하는 것을 제시하였다.

고체에어로졸 자동소화장치 특성 (Characteristics of Fixed Aerosol Auto Fire-Extinguishing Systems)

  • 최병오;홍창수;권성원;박선규
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.277-282
    • /
    • 2008
  • 기존의 범용적인 분말 소화기 또는 가스계 소화장치와는 달리, 특정 성분의 고체 물질이 연소할 때 발생하는 알칼리 금속염이 함유된 에어로졸 형태의 고농도 소화성분으로 화재를 진압하는 자동소화 장치를 개발하였다. 이 장치는 화재발생 시 자동으로 작동되며, 이때 방출되는 에어로졸은 입자 크기가 $1.0{\mu}g$ 이하로 매우 작아 우수한 소화성능을 나타내며, 또한 지구 환경에 영향을 미치는 유해성분을 포함하지 않는 환경 친화적인 차세대 자동소화장치이다.

  • PDF

선박화재 적용 단백포 소화약제의 안정제에 따른 소화특성 (Characteristics of Protein Foam Agent by Stabilizer on the Ship Fire Extinguishment)

  • 이응우;신창섭
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.79-85
    • /
    • 2015
  • Onboard fire extinguishing system is important to protect cargo and human lives and every oil tanker has foam type fire extinguishing system. Because of environmental problem, agent which contains materials such as Perfluorinated compounds are regulated and the development of the environmental friendly agent is required. The protein foam has less environmental pollution problem and has an excellent fire extinguish performance to oil fire. In the research, bivalency metal salts were added as stabilizer to increase fire resistance and stability of the foam. Ferrous sulfate, Iron chloride and Nickel chloride were used and to adjust to vessel, sea water was applied. As a stabilizer increased, the expansion ratio was raised. However 25% drainage time was decreased over 2.0 wt.% which is knowable that the foam brokes easily. The amount of generated foam was measured to check fluidity of foam and it appeared that when $FeSO_4$ 1.2 wt.% was added, the amount of generated foam reached large and also the 25% drainage time was high. To evaluate the fire extinguishing performance for oil fire, the small scale oil fire test was executed. When $FeSO_4$ 1.2 wt.% was added, fire extinguishing time was in its shortest which informs fluidity of foam and stability are important factors on fire extinguishing efficiency.

이동식 미분무수 소화장비의 소화능력 향상에 관한 연구 (A Study on Improving Extinguishing Capacity of Mobile Water Mist Equipment)

  • 공하성;김종진
    • 대한안전경영과학회지
    • /
    • 제11권1호
    • /
    • pp.15-26
    • /
    • 2009
  • This research has so far found out problems including the second damage of extinguishant and the short time of emission when using the existing dry chemical extinguisher and gas type extinguisher, and impossibility of constant extinguishing due to the inability of recharge at the field. To solve such problems, a mobile water mist system was developed and used. However, it is judged that more improved mobile water mist system is necessary because the force of the fire changed diversely and remote villages in mountains or islands where the force of fire extinguishing is short or delayed, require high capacity of fire extinguishing. Therefore a new equipment was developed and tested focusing on the improvement of extinguishing capacity and the performance of extinguishing was found out to be improved, compared to the existing mobile water mist system. It also showed a superior extinguishing capacity to dry chemical extinguisher or gas type extinguisher. Afterward an additional research is required of simplification of equipment, price cutting and the development of additive to enable high performance even with just small extinguishant.

소화약제를 이용한 자동차 엔진룸 화재 실험에 관한 연구 (An Experimental Study on the Automobile Engine Room Fire Using the Extinguishing Agents)

  • 한용택;김동호;권성필
    • 한국화재소방학회논문지
    • /
    • 제28권4호
    • /
    • pp.1-7
    • /
    • 2014
  • 자동차의 엔진룸의 내부를 살펴보면 여러 가지의 장치 및 장비가 복잡하게 설치되어 있고 각종 오일 등의 인화물질을 포함하고 있어 재발화 가능성이 매우 높다. 또한, 폭발가능성도 높기 때문에 운전자나 탑승자가 보닛을 열고 엔진룸에 직접 분말 소화기를 분사하는 방식으로는 한계가 있다. 따라서 엔진룸 내부에서 화재를 감지하여 소화약제를 분사한 뒤, 화재를 진화하는 소화시스템과 엔진룸 내부의 고열에 견딜 수 있고, HFC-227ea를 포함하는 충분한 점성을 가진 폼 형태의 소화약제를 개발 및 시험하였다. 그리고 포소화약제가 가지고 있는 소화원리인 질식 및 냉각효과와 HFC-227ea가 가진 부촉매효과를 동시에 이끌어 내고, 소화 후에도 분말 소화기처럼 잔존물에 의한 2차 피해가 없는 맞춤형 소화약제를 개발하였으며, 차량을 이용한 충돌실험을 통하여 방출이 완료된 후에도 이물질 없이 소화약제를 제거할 수 있는 장점이 존재하는 실험결과를 획득하였다.

소형선박 무인기관실에 적합한 소화장치 개발연구 (A Study on the Development of Fire Extinguishing System for Machinery Spaces of a Small Ship)

  • 김동석;강대선
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.130-131
    • /
    • 2005
  • A study developing the dry powder fire extinguishing system inside the simulated machinery spaces of small ship was performed. Fire tests were conducted inside the compartments having volums 8$m^3$, 2.9$m^3$ and 4.5$m^3$ respectively. The openings and fans were established on the walls of the compartments. Diesel oil was used for the test fuel. In addition fire extinguishing nozzles using dry powder were installed downward at ceiling and horizontally at the wall or conner. All fires in the test were extinguished under system activation and there was no reignition.

  • PDF

전역방출방식 CO2 소화설비의 설계농도 및 유지시간 검증을 위한 직접방사실험에 관한 연구 (A Study on the Direct Discharge Test for Verifying Design Concentration and Soaking Time for CO2 Fire Extinguishing System of Total Flooding)

  • 이세명;문성웅;유상훈
    • 한국화재소방학회논문지
    • /
    • 제26권6호
    • /
    • pp.15-23
    • /
    • 2012
  • $CO_2$ 소화설비의 소화성능 시험방법에는 직접시험방법이 가장 좋지만, 고비용과 환경문제 그리고 시험절차의 어려움으로 간접시험방법을 사용하는 경우가 많다. 그러나 석유화학플랜트나 원자력발전소와 같은 국가 중요위험시설은 화재가 발생하면 대형피해가 발생할 수 있으므로 직접방사시험을 통해 소화성능을 검증할 필요가 있다. 본 연구는 국가 중요위험시설에 설치된 전역방출방식의 $CO_2$ 소화설비 중에서 표면화재 방호구역과 심부화재 방호구역을 각각 선정하여 $CO_2$ 소화설비의 소화성능을 검증해 보았다. 소화성능은 방호구역 내에 방사된 $CO_2$의 농도가 설계농도기준(NFSC 및 NFPA)에 만족해야 그 성능을 인정받을 수 있다. 여기서, 설계농도는 $CO_2$ 소화약제가 화염을 제어할 수 있는 소화농도에 여유율 20 %를 감안한 농도를 의미한다. 시험결과 표면화재와 심부화재 방호구역 모두 $CO_2$ 설계농도를 확보하고 있음을 확인하였고 심부화재의 경우에는 20분 이상 설계농도가 유지되었다. 본 연구를 통해 국가 중요위험시설에 대한 직접방사시험 방법 및 판정방법을 소개하였고 향후 이와 같은 국가 중요위험시설에는 직접방사시험을 통해 소화설비의 신뢰성을 검증해야 할 필요성을 제기하였다.

산업용 질소발생기에 대한 청정소화설비로의 적용가능성에 관한 연구 (A Study on the Possibility of Application as a Natural Extinguishing System for $N_2$ Generator)

  • 서병택;장영근
    • 한국화재소방학회논문지
    • /
    • 제24권2호
    • /
    • pp.139-144
    • /
    • 2010
  • 본 연구에서는 산업용으로 일반적으로 사용하고 있는 질소발생기를 사용하여 할론 계열의 소화약제를 대체할 청정소화설비로 적용할 수 있는지에 대한 소화성능 실험을 간단히 수행하였다. 산업용 질소발생기의 소화성능을 분석하기 위하여 간단한 방호구역을 제작하여 실제 질소발생기에서 발생하는 질소가스를방사하면서 방호구역 내의 산소농도 변화를 실험적으로 파악하였다. 실험결과, 현재 많이 사용하고 있는 질소발생기로 방호구역 $100m^3$에 대하여 질소가스를 $5m^3$/min로 방사하면 3분 이내에 방호구역 내의 산소 농도를 15% 이내로 낮추어 질식소화가 충분히 가능하다.

주 변압기실 화재시나리오에 적용한 미세물분무 노즐의 소화성능 (Performance of Fire Extinguishing of Water Mist Nozzle for Power Transformer Fire Scenario)

  • 이경덕
    • 한국안전학회지
    • /
    • 제21권6호
    • /
    • pp.46-54
    • /
    • 2006
  • Fire extinguishing experiment was conducted with water mist nozzle in case of the pool fire, cascade fire and spray fire on flammable liquid of class B whether water mist system can be effective system for power transformer fire scenario. In the event of a pool fire, flow rate and time to extinguish was inclined to be increased according to the obstruction rate of ignition space. Furthermore, the performance of fire extinguishing depended upon the spraying angle of the nozzles. In case of cascade fire, the effect of extinguishment was began to show from a combustion pan filled with fuel and fuel flowing plate later on.