• Title/Summary/Keyword: Fire trucks

Search Result 14, Processing Time 0.028 seconds

Follow-Up Survey Fire Truck Deterioration (소방자동차 노후화에 따른 고장 발생원인 추적조사 연구)

  • Lee, Jang-Won;Kim, Eui-Tae;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.3
    • /
    • pp.59-64
    • /
    • 2015
  • This study analyzed results of the causes of failure in 1,022 fire trucks currently being used in South Korea (aerial ladder, aerial platform, pumper, and chemical fire trucks). The results show that 46% of aerial ladder trucks have defective in the elevator brake systems, 29% of aerial platform trucks have contamination in the hydraulic oil, 37% of pumpers have defective in the pneumatic cylinders of the air supply system, and 39% of chemical fire trucks have defective in the powder fire extinguishing systems. The principal reasons for malfunctions are deterioration of the apparatuses, and accumulated fatigue from repetitive use of certain components, such as pneumatic cylinders in the air supply system and wire rope jamming in rollers in the ladder apparatus. These manufacturing defects should be improved upon in the manufacturing process. As a result, the fire trucks, which are used for 5 years or more, need precise inspections in accordance with the Regulation on Fire Apparatus Maintenance. Fire apparatuses have a service life of 10 to 12 years or more. They need to be replaced or require life extension, and they should be kept in top shape with the best maintenance for public safety.

Real-time traffic situation analysis and fire type artificial intelligence application study when 119 fire trucks are dispatched Intelligence research (119 소방차 출동 시 실시간 교통상황 분석 및 화재유형 인공지능 적용 연구)

  • Lee, Han-young;Park, Dea-woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.222-224
    • /
    • 2022
  • Korea has more than 2,000 fires and more than 2,000 casualties every year. This study takes measures to facilitate the incorporation of 119 fire trucks by judging vehicles or standing signs using real-time image reading YOLO5 before the fire trucks arrive at the fire site. It is possible to shorten the time to extinguish a fire by photographing a fire site, transmitting the situation of the site, and analyzing the components of smoke to determine the type of fire. As a result, it is expected that it will be able to minimize casualties by keeping the golden time.

  • PDF

A Study on Fire Suppression Measures Used in Wooden Temples (목조 사찰화재의 유형별 진압대책에 관한 연구)

  • Ko, Gi-Bong;Lee, Si-Young;Chae, Jin
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.10-17
    • /
    • 2012
  • This study classifies the fire suppression measures implemented by wooden temples into four types according to availability of the pump trucks (water tanks) at the fire sites. And this study outlines the strategies and methods based on each type of fire suppression measure. The results show that the fire suppression strategy applied in general buildings is also employed in temples where pump trucks (water tanks) and fire-fighting water are available. For temples where trucks and water are not available, the helicopter, water bag, fire suppression strategy focused on water supply link, automatic transmission system of a fire engine's level by using radio communication network, and water bladder are used. In addition, general four-wheel-drive vehicles equipped with fire fighting tools such as motor pump, hose, nozzle, and water bladder should be deployed in fire stations around the temples. A fire suppression strategy using A-type ladders is also required.

Evaluation of Fire Safety for Road Tunnels in Port Area based on Fire Safety Guidelines (도로터널 화재안전기준 기반 항만 지역 도로터널 화재 안전성 분석)

  • Ha, Yejin;Jeon, Joonho
    • Journal of Institute of Convergence Technology
    • /
    • v.11 no.1
    • /
    • pp.25-28
    • /
    • 2021
  • Recently, the fire safety of road tunnels has been important issues in South Korea. However, proper fire safety regulations has not made for road tunnels. Due to geographical challenges in South Korea, road tunnels should be constructed to secure stable traffic flows. In the Guidelines for Installing and Managing Disaster Prevention Facilities of Road Tunnels (NFSC 603), main target vehicles are passenger cars. This guidelines cannot support big fires from larger vehicles such as cargo, oil trucks. In this study, fire safety for a road tunnel in port area was analyzed with fire dynamics theory under cargo truck fire scenario. Sujunsan road tunnel in Busan city was chosen as a target tunnel, which links between Busan port and highways to increase cargo shipping. The results show the limitations of present guidelines (NFSC 603) for road tunnel from large fire situations.

Predefined Access Routes for Quick Response to Disaster Areas (방재경로 구축방안에 관한 연구 (지구단위 방재경로를 중심으로))

  • Jo, Yong-Chan;Lee, Chang-Ju;Sin, Seong-Il
    • Journal of Korean Society of Transportation
    • /
    • v.25 no.6
    • /
    • pp.43-53
    • /
    • 2007
  • In this research, in order to more concretely define the concept of the previously vaguely defined fire road, the authors propose new terminology called disaster prevention routes. These are defined as predefined access routes for the quick response to disaster areas. For this, the authors suggest selection techniques for disaster prevention routes considering characteristics of fire trucks and selected areas. The paper also includes legally-based ideas for the executive departments with exclusive responsibility for continuous management and supervision of disaster response. In addition, a case study is performed with a virtual scenario including the outbreak of fire in one borough of Seoul. This case study shows that the damage can be decreased by prompt access of fire trucks. The establishment of predefined access routes to disaster areas can help to protect citizens with more rapid response by emergency crews. Indirect benefits also include reduced congestion of roads through the prohibition of parking and stopping on the chosen roads.

A Study on the Improvement Method of the Fire Department Connection for Fire Fighting at the Shopping Center Building (상가건물 소방용 연결송수관설비 송수구의 개선방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.4
    • /
    • pp.11-17
    • /
    • 2016
  • Currently, the number of a shopping center building is increasing because most people want to go a shopping center building easily for buying many things and eating some foods. That are a normal trend these days. However, the increasing number of shopping center buildings has been increasing the number of shopping center building fires which also have been making social problems. Therefore, this study was conducted for the fire department connection among other fire facilities because it is important for fire suppression. The research subject is on the fire department connections that are on 70 shopping center buildings of more than 5 years old constructed. Survey and analysis were conducted for 70 fire department connections. The result of this study is that all installed fire department connections have a type that includes one or two holes each at 65mm wide, and the average distance between fire department connections and access roads is 4.85m. The total average percentage of insufficiency conditions such as drive ways for fire trucks, visibility, accessibility, pressure range sign, installed height, cover of the hole, etc. is 45.3%. So improvement of law and systems, that are fire facility construction and maintenance implementations, will be needed in my opinion.

EVALUATION OF AN ACCIDENT MANAGEMENT STRATEGY OF EMERGENCY WATER INJECTION USING FIRE ENGINES IN A TYPICAL PRESSURIZED WATER REACTOR

  • PARK, SOO-YONG;AHN, KWANG-IL
    • Nuclear Engineering and Technology
    • /
    • v.47 no.6
    • /
    • pp.719-728
    • /
    • 2015
  • Following the Fukushima accident, a special safety inspection was conducted in Korea. The inspection results show that Korean nuclear power plants have no imminent risk for expected maximum potential earthquake or coastal flooding. However long- and short-term safety improvements do need to be implemented. One of the measures to increase the mitigation capability during a prolonged station blackout (SBO) accident is installing injection flow paths to provide emergency cooling water of external sources using fire engines to the steam generators or reactor cooling systems. This paper illustrates an evaluation of the effectiveness of external cooling water injection strategies using fire trucks during a potential extended SBO accident in a 1,000 MWe pressurized water reactor. With regard to the effectiveness of external cooling water injection strategies using fire engines, the strategies are judged to be very feasible for a long-term SBO, but are not likely to be effective for a short-term SBO.

Fire-fighting Pump Approval Standard for Fire-fighting Trucks with an Additional Positive Displacement Pump (용적형 펌프를 추가한 소방자동차용 소방펌프의 성능 인정기준에 관한 연구)

  • Han, Yong-Taek;Sung, Ki-Chan;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.104-110
    • /
    • 2016
  • Positive displacement pumps with high pressure and water capacity are used large fires in various high-rise buildings. This study provides information for a performance approval standard of fire pumps for fire trucks based on centrifugal pump standards enacted in 2012. An experiment was conducted with a positive displacement pump for three levels of performance from the approval standard (V-1, 2, and 3). The efficiency of the pump was included in the reference, which requires the approval of 65% performance, the same as a centrifugal pump. The water pressure is between 1.5 and 2.5 MPa, and the required flow rate was established as at least $0.31m^3/min$ and up to $3.0m^3/min$. A relief valve was added to adjust the shut-off pressure due to the structural characteristics of the positive displacement pump. A strainer was also installed to prevent damage to the inside of the pump due to foreign matter. However, the strainer includes a difference from the positive displacement pump to operate without a vacuum pump and the centrifugal pump. This is due to the additional approval standard portion of the positive displacement pump, which is expected to be selected for more variety of fire-fighting equipment and proactive responses to fire suppression in a high-rise buildings and large fires. In conclusion, this approval standard was enacted in January 2016.

Resin Optimization for Manufacturing CFRP Hydrant Tanks for Fire Trucks (소방차용 CFRP 소화전 탱크제조를 위한 수지 최적화 연구)

  • Huh, Mong Young;Choi, Moon Woo;Yun, Seok Il
    • Composites Research
    • /
    • v.35 no.4
    • /
    • pp.255-260
    • /
    • 2022
  • Lightweight hydrant tanks increase the amount of water that can be carried by fire trucks, resulting in longer water spray times during the initial firefighting process, which can minimize human and property damages. In this study, the applicability of carbon-fiber-reinforced polymer (CFRP) composites as a material for lightweight hydrant tanks was investigated. In particular, the resin for manufacturing CFRP hydrant tanks must meet various requirements, such as excellent mechanical properties, formability, and dimensional stability. In order to identify a resin that satisfies these conditions, five commercially available resins, including epoxy(KFR-120V), unsaturated polyesters(G-650, HG-3689BT, LSP8020), vinyl ester(KRF-1031) were selected as candidates, and their characteristics were analyzed to investigate the suitability for manufacturing a CFRP hydrant tank. Based on the analyses, KRF-1031 exhibited the most suitable properties for hydrant tanks. Particularly, CFRP with KRF-1031 exhibited successful results for thermal stability and elution tests.

A Study on the Reduction of Psychological Unrest Factors through the Improvement of Fire Service System (소방업무 제도개선을 통한 심리적 불안 요인 감소 방안)

  • Young-Jin, Reem;Ha-Sung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.4
    • /
    • pp.105-115
    • /
    • 2023
  • The purpose of this study is to identify psychological anxiety factors related to firefighters' field activities and suggest improvement measures. To investigate the actual status of psychological anxiety factors, a survey was conducted on approximately 3,500 current firefighters, and the responses of 505 people who participated in the survey were analyzed. As a research method, frequency analysis and cross-analysis were conducted according to the general characteristics of the participants to determine the actual level of psychological anxiety in each work field and the results were analyzed. As a result of the analysis, it was statistically confirmed that firefighters feel a lot of psychological burden due to legal and institutional inadequacies during dispatch, return, or field activities, and frequent friction with civil servants is also a major cause of psychological anxiety. Therefore, based on the results of this study, it is proposed to establish a permanent legal support team in each city and province, designate and operate a hospital dedicated to psychological treatment, and establish a special provision for traffic accidents during the return of fire trucks so that firefighters can concentrate on their duties without psychological anxiety. do.