• 제목/요약/키워드: Fire sprinkler head

검색결과 58건 처리시간 0.023초

An Analysis of Working Hours by Type of Sprinkler Head Used at Indoor Gymnasiums

  • Ahn, Jae-Cheon;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • 제10권4호
    • /
    • pp.117-123
    • /
    • 2021
  • This study aims to analyze working hours of sprinkler heads when a fire occurs at an indoor gymnasium while sprinkler heads are installed in division of standard response type, special response type, and earlier response type. The fire scenario was designed under the assumption that the fire started from overheating of a heater in the indoor gymnasium has transferred on to a couch to spread. The analysis on the operation time of the standard response type sprinkler head, the special response type sprinkler head and the early response sprinkler head was conducted. The result showed that, in case of fire in a gymnasium, the time for opening of the heat sensor due to the heat from the fire varies by the type of the sprinkler head. When a special response type sprinkler is installed, it worked below the assessment standards. When an early response sprinkler head is installed, it worked appropriately according to assessment standards. Based on the results, we found that sprinkler heads will work properly when installed according to design relevant to laws and regulations. This means that there is a limit in installation of sprinkler heads based on the existing law-based design as for indoor gymnasiums. Again, we conclude that if sprinkler heads are installed based on design made through laws and regulations, more time will be needed for operation, making it highly likely to fail to stop a fire at an earlier point of time.

소화용 스프링클러 헤드의 살수분포 및 수적 특성에 대한 연구 (The Study on Characteristics of Water Spray and Droplet from Fire Sprinkler Head)

  • 추병길;최종욱;차경세
    • 한국안전학회지
    • /
    • 제16권2호
    • /
    • pp.13-21
    • /
    • 2001
  • The effect of water spray for the fire sprinkler depends on droples distribution over maximum possible floor area. The present study are carried out for the characteristics of water spray and droplets experimentally and numerically km two fire sprinkler heads which are CHM head and CHl heal CHl head is self-production and CHl head is widely used up to date. As the result of using CHM head, water spray and droplets are distributed over large area because CHM head has smooth surface and non-flamed shape. When the pressure of fire sprinkler head is low, SMD(sauter mean diameter) is large and when the pressure of fire sprinkler head is high, SMD is small.

  • PDF

스프링클러 헤드의 방수상수에 따른 소화성능에 관한 실험적 연구 (An Experimental Study on the Extinguishing Performance of Sprinkler Heads according to Discharge Coefficient)

  • 허민녕;신창섭
    • 한국안전학회지
    • /
    • 제33권2호
    • /
    • pp.32-38
    • /
    • 2018
  • The sprinkler system is a basic fire extinguishing system widely used, but there is a lack of quantitative assessment of its performance. In this study, to evaluate the fire extinguishing performance of the sprinkler head according to the discharge coefficients, experiments were conducted. Experimental sprinkler heads were selected with heads having K50, K80 and K115 water discharge coefficients, and the fire source was assumed to be an indoor fire in Class A Model 1. As experimental results, the time required for the fire chamber to cool down to $200^{\circ}C$ was 26 seconds for the K115 head, 414 seconds for the K80 head, and 481 seconds for the K50 head, so the cooling time of the K115 head was decreased by 94.5% compared to K50 head. In the case of restoring the oxygen concentration to 15%, the K115 head did not decrease below the oxygen concentration of 15%, and the K80 head took 145 seconds and the K50 head took 484 seconds. The lowest oxygen concentration in the fire chamber was 16.1% for the K115 head, 14.33% for the K80 head, and 11.28% for the K50 head, indicating that the K115 head was superior to the K80 and K50 heads by 13.1% and 43.7%, respectively. As the experimental results show, there is big difference in the extinguishing performance depending on the discharge coefficients of the sprinkler head. Therefore, in designing the sprinkler system, the discharge coefficients of the sprinkler head should be selected considering the heat release rate at the installation site and the fire extinguishing characteristics of sprinkler head.

화재 진압용 스프링클러 헤드 유형에 따른 살수 균일도 분석 (Analysis of Water Flux Uniformity for Various Fire Sprinkler Head Type)

  • 방새미;안찬섭;김태훈
    • 한국분무공학회지
    • /
    • 제28권2호
    • /
    • pp.97-104
    • /
    • 2023
  • A sprinkler is a fire suppression system that extinguishes combustible materials in the early stages of a fire, creating a spray. However, spray formation method of the sprinkler can result in an uneven distribution of water spray on the surface of combustible materials. It is necessary to ensure a consistent water flux density regardless of the spray direction and angle. In this study, the water flux distribution was analyzed for the various types of sprinkler head: circular, flush, pendent, and upright types. All sprinkler heads have a K-factor of 80 LPM/(0.1MPa)0.5. In this study, water collection cubes were used to examine the water flux distribution. The upright type sprinkler head showed a low standard deviation in total sprayed area, indicating a high level of uniformity. The upright type head showed the lowest standard deviation in the radial direction, and also showed the lowest standard deviation in the azimuthal direction. Upright sprinkler head has no obstructing structure along the path of droplets after they are generated. For this reason, upright sprinkler head showed the most uniform water flux distribution on the floor.

Combustible Gas and Visible Distance by Sprinkler Head for Safety of Gymnasium Workers

  • Ahn, Jae-Cheon;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • 제10권3호
    • /
    • pp.232-244
    • /
    • 2021
  • This study analyzed the changes in carbon monoxide, carbon dioxide, oxygen and visual distance by presence of sprinkler heads and their types in the event of a fire in an indoor gymnasium. Based on carbon monoxide and visual distance that affects human bodies enormously, first, if there is no sprinkler head, carbon monoxide will reach 0.4% within five seconds and visual distance rapidly shrank within five seconds. Seconds, in the event of standard sprinkler heads, carbon monoxide gradually increased from 30 seconds onwards and visual distance rapidly shrank after five seconds. Second, Third, if there are special sprinkler heads, carbon monoxide fluctuated after opening the head and visual distance became 5m or below from 15 seconds. Finally, in the event of early response sprinkler heads, carbon monoxide fluctuated up and down at 3 seconds due to falling water drops. Visual distance shrank up to 5m or below at 6 seconds. In the future, time for operation of each sprinkler head shall be analyzed.

화재성장시나리오에 따른 스프링클러 헤드의 작동조건 (Activation Conditions of Sprinkler Head Considering Fire Growth Scenario)

  • 김성찬
    • 한국화재소방학회논문지
    • /
    • 제34권4호
    • /
    • pp.45-51
    • /
    • 2020
  • 본 연구에서는 스프링클러 헤드의 해석모델을 통해 화재성장모드별 스프링클러 작동시 연층기류의 열유동조건을 파악하고자 한다. 화원은 최대발열량 3 MW의 시간제곱의 화재성장을 가정하였다. 시험대상 스프링클러헤드는 작동온도 65~105 ℃, RTI 25~171 m1/2s1/2 범위의 표준형과 조기반응형 8종을 대상으로 한다. 연층기류의 온도와 감열부의 온도차는 화재성장이 느리고 스프링클러 헤드의 RTI값이 작을수록 감소하는 경향을 보였다. 스프링클러 헤드 작동 순간의 연층 기류 온도와 속도조건은 전체적으로 시험기준의 범위와 비교적 잘 일치하고 있으나 저성장 화재에서는 최저시험기준 이하의 온도와 속도조건에서 작동이 이루어질 수 있음을 파악하였다. 본 연구는 스프링클러 헤드의 작동에 대한 기초연구로서 시험기준의 신뢰성을 향상시키는데 기여할 수 있다.

가용합금형 스프링클러 헤드의 열감도 특성에 관한 실험적 연구 (Experimental Study on the Characteristics of Thermal Sensitivity for Fusible Alloy Type Sprinkler Head)

  • 권오승;이진호
    • 한국화재소방학회논문지
    • /
    • 제9권1호
    • /
    • pp.20-29
    • /
    • 1995
  • The sprinkler head is a component of the sprinkler system intended to discharge water for automatic detection and extinguishment of fires. On this study, thermal characteristic values affecting the sensitivity of the fusible alloy type sprinkler head were obtained and analyzed under heated air stream condition which had constant temperature and velocity. The experiment was carried out under the forced convection condition with both the conductive heat loss considered and neglected. The thermal characteristic values of the sprinkler head were obtained in accordance with the material and shape of the heat responsive element and the conditions of the main body.

  • PDF

스프링클러헤드 응답성에 관한 실험적 연구 (An Experimental Study on the Responsiveness of Sprinkler Heads)

  • 김동석;박용일;박희용
    • 한국화재소방학회논문지
    • /
    • 제7권2호
    • /
    • pp.3-12
    • /
    • 1993
  • The closed type sprinkler head is a component of sprinkler system for fire protection. The purpose of this study is to inverstigate the influence factors of the responsiveness of the head by heated wind tunnel experiment. As the result of this study, it was found that response time index and conduction parameter showed the same characteristic quantitative changes to head types and test methods.

  • PDF

랙크식 물류창고의 스프링클러설비 소화성능에 관한 실험연구 (Experimental Study on the Suppression Performance of Sprinkler Systems in Rack-type Warehouses)

  • 최기옥;최돈묵
    • 한국화재소방학회논문지
    • /
    • 제33권3호
    • /
    • pp.44-50
    • /
    • 2019
  • 랙크식 창고 내에는 화재하중이 높은 물품이 수직으로 조밀하게 적재되어 있어 창고의 내부에서 화재가 발생되는 경우 현재의 스프링클러설비에 의해 유효하게 소화되기 어렵다. 이에 본 연구에서는 실물 규모의 랙크 구조물을 구축하고, 구조물 내부의 스프링클러헤드 종류 및 배치에 따른 화재실험을 통해 스프링클러설비에 의한 소화유효성을 확인하였다. 본 연구를 통하여 랙크식 창고의 내부의 화재를 유효하게 진압하기 위해서는 방수량 115 LPM 이상의 스프링클러헤드를 사용해야 하며, 동 스프링클러헤드를 높이 기준이 아닌 랙크 각 단마다 설치해야하고, 각 단의 가연물더미의 대각선 모서리 위치에 설치될 필요가 있다는 것을 알 수 있었다.

방화구획 완화에 따른 PCB공장의 화재위험평가 및 스프링클러 요구살수유량 산정을 통한 기준개선안에 관한 연구 (A Study on a PCB Manufacturing Plant's Fire Risk Assessment due to the Mitigation of Fire Protection Zone and an Improvement Way through Estimation of Sprinkler Demand Water Flow Rate)

  • 오찬욱;오륜석;최준호
    • 한국화재소방학회논문지
    • /
    • 제33권2호
    • /
    • pp.56-62
    • /
    • 2019
  • 스프링클러는 방호구역에 설치된 감지기 또는 헤드가 화재를 감지하여 자동으로 화재를 진압하는 소화설비로 화재 초기에 뛰어난 소화효과가 있어 폭넓게 설치되고 있다. 하지만 국토교통부의 "건축물의 피난 방화구조 기준 등에 관한 규칙"에는 공장 또는 창고의 경우 스프링클러설비를 설치하면 방화구획을 3배까지 완화해 줄 수 있도록 그 근거를 제공하고 있다. 이에 본 연구에서는 스프링클러설비 설치로 방화구획을 완화한 실제 Printed Circuit Board (PCB) 공장 1개소를 대상으로 화재위험성을 분석하였고, 컴퓨터 시뮬레이션을 통한 스프링클러설비의 헤드 개방 특성 및 스프링클러 설비의 설치기준, 감열성능, 작동범위, 방수량 등을 분석하였다. 또한 이를 통해 화재 시 스프링클러 설비 작동의 문제점을 확인하고, 제도 개선을 위한 요구 살수유량 등 근거를 제시하고자 한다.